| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | Material and labour for cement concrete 1:4:8 (type D2) using 40 mm graded stone aggregate in foundations, filling and mass-concrete complete all as specified and directed. |
| 3 | Demolition of brick work or laterite stone masonry built in cement mortar including precast concrete articles complete all as specified and directed. |
| 4 | Material and labour for laterite stone walling of squared rubble, regular coursed well bounded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed |
| 5 | Material and labour for laterite stone walling of squared rubble, regular coursed well bounded, bedded and solidly hearted built in CM 1:6 by using serviceable stone obtained from serial item No 4 here- in- before ie except stone complete all as specified and directed |
| 6 | Material and labour for extra over stone walling for hammer dressing to face stone and dressing of face beds and joints, as specified, ofsquared rubble masonry regular coursed, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 20mm complete all as specified and directed |
| 7 | Material and labour for rendering 15mm thick cement plaster in cement mortar 1:6on stone masonry surfaces other than fair face, finished even and fair without using extra cement complete all as specified and as directed |
| 8 | Material and Labour for preparation of newly plastered or concrete wall surface and applying two coats of colour wash complete all as specified and directed |
| 9 | Material and Labour for cement concrete 1:2:4 (type B1) using 20mm graded stone aggregate in copings, bed plates and kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed |
| 10 | Dismantling fencing wire mesh complete all as specified and as directed |
| 11 | Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete, including takingout embedded portion and making good disturbed ground complete all as specified and as directed |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 13 | Supply and Fix MS work as in fencing posts angle iron/Tee section, drilled and countersunk for balusters running bars, including embedingin concrete and scuring etc, post and struts in fencing including cutting tops to shape as directed, drilled holes, notchingfor wire, etc, flatironfillets, (for securing wire mesh etc,) holding pr riveting etc, and similar work confirming to Fe-290 Gde E-165 complete all as specified and as directed |
| 14 | Supply only Chain MS Galvanisedfencing of 10 gauge wire with 1mm PVC Coating of 80x 80mm mesh size complete all as specified and as directed |
| 15 | Fixing only chain link fencing including line wire, any mesh size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and as directed |
| 16 | Supply and Fix MS 10mm dia screwed bolt (machine made) hexagonal/square headsat one end and sed the others, for screwed or both ends, each screwed and ends to be fitted with washers and one hexagonal/square nut, not exceeding 10 cm long complete all as specified and as directed |
| 17 | Material and labour for applying two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10cm width or girth complete all as specified and as directed. |
| 18 | Supply and Fix galvanised stand steel barbed wire 2.24 mm dia barbed with 2mm dia barbes at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire stapples or steel pins etc complete all as specified and as directedNote: Each line of wire to be measured separately |
| 19 | Material and Labour for chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement of pigment, set, jointed and pointed in neat cement slurry in floors complete all as specified and as directed |
| 20 | Material and Labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and as directed |
| 21 | Material and Labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed |
| 22 | Material and Labour for screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor tiles complete all as specified and as directed |
| 23 | Material and Labour for cement concrete 1:3:6 (type C2) using 40 mm graded stone aggregate as in walls, pillars and posts, etcincluding caps and bases complete all as specified and directed |