| 1 | PART-I:- M & L for flushing the complete condensing unit of AC, refrigerator, water coolers and deep freezer, and search out leakage and rectifying by means of brazing and replacing the charging lines, Strainers, capillary tube etc rectification of the leakage from the system including testing and commissioning of system, complete all as specified and directed. |
| 2 | S&F in repairof condensing unit and housing the unit of the split type AC, complete all as specified and directed. |
| 3 | Supply & charging refrigerant gas R-22 suitable for environment friendly charging line on sealed unit of compressor of AC 1.5/2.0 ton including crimping and resoldering to charging line, complete all as specified and directed. |
| 4 | Supply & charging refrigerant gas R-32 suitable for environment friendly charging line on sealed unit of compressor of AC 1.5/2.0 ton including crimping and resoldering to charging line, complete all as specified and directed. |
| 5 | Removing the unserviceable compressor unit from the window/splittype room AC 1.5 ton and supply and fix new hermetically sealed compressor unit, suitable to operate in AC single phase 50 Hz, 230 Volts suitable for window/split type AC 1.5 ton, complete all as specified and directed by Engineer-in-Charge. |
| 6 | All as per item no 5 but for AC of capacity 2.0 Ton, complete all as specified and directed. |
| 7 | Removing the unserviceable compressor unit from the water cooler of any capacity and supply and fix new compressor unit, suitable to operate in AC single phase 50 Hz, 230 Volts all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fix repair PCB for 1.5to 2.0 ton capacity AC, complete all as specified and directed. |
| 9 | Supply and fix repair Evaporator coil for 1.5to 2.0 ton capacity AC, complete all as specified and directed. |
| 10 | Supply and fix repair Front grill for 1.5to 2.0 ton capacity AC, complete all as specified and directed. |
| 11 | Supply and fix repair Starting relay for 1.5to 2.0 ton capacity AC, complete all as specified and directed. |
| 12 | Supply and fixrepair Starting capacitor 80-100 mfd for 1.5to 2.0 ton capacity AC, complete all as specified and directed. |
| 13 | Supply and fix Running capacitor 36 mfd for 1.5to 2.0 ton capacity AC, complete all as specified and directed. |
| 14 | Supply only Compressor mounting rubber bush(set of 3 Nos counted as one unit), complete all as specified and directed. |
| 15 | S&F repair blower fan motor for split unit AC 1.5 ton to 2.0 ton (As per sample), complete all as specified and directed. |
| 16 | S&F repair condenser Fan blade rings 1.5 to 2.0 ton (As per sample), complete all as specified and directed. |
| 17 | S&F repair thermostat unit including electronic relay eqpt and electronic plate for air conditioner, complete all as specified and directed. |
| 18 | S&F Solenoid Valve for 1.5/2.0 Ton window/split AC, incl taking down old valve, complete all as specified and directed. |
| 19 | S&F auto swing motor 12 Volts for 1.5/2.0 Ton window/split AC, incl taking down old motor, complete all as specified and directed. |
| 20 | Disconnecting unserviceable three core flexible cord from window type AC/ Refrigerator/ voltage stabilizers of any capacity and S & F three core flexible cord of size 2.5 sqmm, complete all as specified and directed. |
| 21 | Cutting suction and discharge gas pipe line and taking out unsv compressor unit from refrigerator of165/180 ltrs capacity and S&F new sealed compressor unit of same model or approved model of same capacity, complete all as specified and directed. |
| 22 | All as Item No. 21 above but for refrigerator of capacity 210/310/320 ltrs, complete all as specified and directed. |
| 23 | Cutting suction and discharge gas pipe line and taking out unsv compressor unit from deep freezer of 300/400 ltrs capacity and S&F new sealed compressor unit of same model or approved model of same capacity, complete all as specified and directed. |
| 24 | S&F in repair of cooling coil and housing of the refrigirater unit of any make (280 ltr to 310 ltr), complete all as specified and directed. |
| 25 | S&F relay for refrigerator, including taking down old relay, complete all as specified and directed. |
| 26 | S&F thermostat unit for refrigerator, including taking down old thermostat, complete all as specified and directed. |
| 27 | S&F pigmy lamp pin/thread type 15 watts, 230 volts suitable for refrigerator, incl removing old bulb/lamp, complete all as specified and directed. |
| 28 | S&Fdoor gasket for refrigerator (as per sample) incl taking down old door gasket & aligning door after opening from body incl inserting packing, welding, threading etc which so ever required to leave no air gap between door & body and top edge of refrigerator flushing with top surface of refrigerator of capacity 180/190 ltrs, complete all as specified and directed. |
| 29 | All as Item No. 28 above but for refrigerator of capacity 280/310/320 ltrs capacity. |
| 30 | Taking out unserviceable lock from the refrigerator and S&F new lock with keys, complete all as specified and directed. |
| 31 | Dismantling unserviceble freezer defrosting fan from double door refrigerator and replaced with new freezer defrosting fan of same model/capacity 200 to 300ltr, complete all as specified and directed |
| 32 | M & L for replacement ofunserviceble/damagefreezer cooling coil assembly complete of existing model for refrigerator 180/190 ltrs capacity, complete all as specified and directed. |
| 33 | All as item No 32 above but refrigerator of 280/310/320 ltrs, complete all as specified and directed. |
| 34 | Supply & charging refrigerant gas R-134A charging line on sealed unit of compressor of refrigerator including crimping and resoldring to charging line, complete all as specified and directed. |
| 35 | Taking down unserviceable capillary from any capacity ofRefrigerator, supply & joint new capillary for charging refrigerant gas in machine, complete all as specified and directed. |
| 36 | Taking down old unserviceable liquid filter/drier from Refrigerator, Supply & joint new liquid filter/drier for charging refrigerant gas in machine, complete all as specified and directed. |
| 37 | Taking down old unserviceable OLP+Relay Kit PTC from anycapacity ofRefrigerator, supply & joint new OLP, complete all as specified and directed. |
| 38 | Taking down old unserviceable Timer from any capacity ofRefrigerator, supply & joint new timer, complete all as specified and directed. |
| 39 | Supply only Butane Gas for brazing purpose in can of 225 gram, complete all as specified and directed. |
| 40 | M & L for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt conforming to C curve, complete all as specified and directed. |
| 41 | S&F Pluring nut & Copper tubing 1/4\" |
| 42 | S&F Pluring nut & Copper tubing 1/2\" |
| 43 | S&F Pluring nut & Copper tubing 5/8\" |
| 44 | S&F Indoor unit complete for Split AC 2.0 TR (hot & cold mode) as per existing make, complete all as specified and directed. |
| 45 | S&F outdoor unit complete for Split AC 2.0 TR (hot & cold mode) as per existing make, complete all as specified and directed. |
| 46 | S&F voltage stabilizer of capacity 5 KVA with digital display & working range 130-280 Volts AC complete all as specified. |
| 47 | M&L for painting of indoor & outdoor unit of split AC of capacity 1.5/2.0 Ton with spray painting as per existing colour, after taking down unit from wall and refixing the same after painting, complete all as specified and directed. |
| 48 | M&L for painting of outer body of Refrigerator of any capacity with spray painting as per existing colour, complete all as specified and directed. |
| 49 | M&L for iron stand for outdoor unit of split AC, incl taking down old unsv one, complete all as specified and directed. |
| 50 | Supply only brazing blow torch for operating Butane gas cylinder, complete all as specified and directed. |
| 51 | Supplying Nitrogen gas alongwith cylinder capable of handling high pressure for removing all the moisture from the pipes of AC & Refrigerators, complete all as specified and directed. |