Tender For Work Related To Supply Operation And Installation Of Necessary Equipments For The Functioning Of Pre Built 15 Mld I.P.S In Highway City Vistar(Sajari), kanpur-Uttar Pradesh

Local Bodies has published Tender For Work Related To Supply Operation And Installation Of Necessary Equipments For The Functioning Of Pre Built 15 Mld I.P.S In Highway City Vistar(Sajari). Submission Date for this Tender is 17-08-2024. Sewerage Construction Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44362021
Tender For Work Related To Supply Operation And Installation Of Necessary Equipments For The Functioning Of Pre Built 15 Mld I.P.S In Highway City Vistar(Sajari)
Open Tender
Indian
Uttar Pradesh
Kanpur
17-08-2024

Tender Details

Tender For Work Related To Supply Operation And Installation Of Necessary Equipments For The Functioning Of Pre Built 15 Mld I.P.S In Highway City Vistar(Sajari), 1 A-LAYING OF SEWER LINE FROM EXSTING MANHOLE TO IPS 2 Supply of the following pipe suitable for R/R joints as per relevant IS Specification FOR destination including all taxes, insurance and transportation charges up to UP Jal Nigam Divisional Stone in Ghazipur city 500 mm dia DI K – 718.72.9 DSR 2021 3 Supply of the specials for above pipes 4 Supply of following D.I.D/F fittings as per relevant IS Specification or other equivalent make FOR destination including all taxes, insurance and transportation charges 5 500 mm dia double orifice kinetic type air valve 6 NRV 500 mm dia 7 Sluice valve 500 mm dia 8 Excavation for following depth below G.L. for laying of Rising mains in ordinary soil earth, sand, loam, and clay including cutting of jointing pits trimming dressing leveling refilling of trenches in 20cm layers watering and ramming the same including removal of surplus earth or other dismantled materials up to a distance 50m from the center of trenches. 9 0.0 - 1.5 10 Extra on above for excavation in soil mixed with moorum shingle kankar etc. where special T & P is to be used. 11 0.0 - 1.5 12 Carting of following sizes of DI-K-9 Pipes & rubber rings from store to site of work, lowering the same into trenches and laying true to the alignment and gradient including excavation of earth below invert of pipes cost of all jointing materials testing etc. complete. 13 500 mm DI K - 7 14 Carting & re-carting of excavated earth where sufficient width of road is not available for stacking of surplus earth during excavation & laying of Riming mains (Average lead 250m) 15 Carting of following sizes of CI fittings from store to site of work lowering the same into the already prepared, tranches also including fixing in position including supply of all materials such as bolts, nuts rubber packing, white lead etc. labour & T&P complete 16 500 mm dia double orifice kinetic type air valve 17 NRV 500 mm dia 18 Sluice valve 500 mm dia 19 Supply of all materials labour T&P for construction of Brick masonry chamber to place sluice valve, Air valves etc. complete as per UP Jal Nigam type Design 20 Supply of all materials labour T & P etc. complete for construction of cement concrete Thrust Blocks (2.5*1.25*1.25m size) in 1:2:4 cement, coarse sand and 20mm gauge stone ballast also including excavation, refilling properly fixing pipe/ bends etc. all complete at suitable locations i.e. bends etc. as directed by Engineer in charge 21 B- CONSTRUCTION OF BYE PASS SEWER FROM IPS TO EXSTING SEWER LINE FOR STP 22 Excavation in foundation in ordinary soil (loam, clay and sand) for lead upto 50 M and lift up to 1.50 M filling, watering and ramming of excavated earth into the space of foundation trench and disposal of surplus earth up to a distance of 50 M from the foundation trenches. 23 Depth Below G.L. 24 0.00 - 1.50 M 25 1.50 - 3.00 M 26 3.00 - 4.50 M 27 Supply of 700mm dia DI K-7 Pipe 28 Laying and Joining of Sewer 700mm dia DI K-7 Pipe 29 Bedding 30 Lean Concrete in foundation in 1:4:8 proportion with cement, coarse sand and 40 mm gauge stone ballast including supply of all materials, labour T&P etc. for proper completion of work. 31 Plain cement concrete in proportion 1:2:4 cement, coarse sand and 20 mm gauge stone ballast including centering and shuttering all labour, material T&P etc. complete 32 RCC 1:1½:3 block at the end of Bye Pass Sewer to keep it in position preventing from flood damage or otherwise in cement coarse sand 20mm gauge grit including supply of all other materials labour T&P etc. complete 33 Launching Apron 34 MS Works 35 Steel work welded in builtup section 36 Site Clearance & unforeseen works 37 Miscellaneous Works 38 C-INSTALLATION OF PUMPING PLANT & ACCESSORIES AT INTERMEDIATEPUMPING STATION (I.P.S.) 39 PUMPING PLANT 40 Non-clog, single stage, Bottom suction submersible sewage pump suitable for handling raw sewage of a specific gravity of 1.03 driven by submersible electric motor suitable for operation on 380 + 10% volts, 3 phase, 50 Hz, AC supply system along with 35 mtrsubmersible cable and having following specification & M.O.C.Capacity - 90 LPSTotal Head - 20 mtrH.P. of Motor - 45 RPM (Synch) - 1500 M.O.C.Pum cacing - As per IS 210 Mechanical - Eagle Burgmann Impeller- CF8MSS-316Shaft - As per AISI-410 41 Accessories of each submersible pumping plant 42 (a) Pedestal with autocouping - 1 No. (b) S.S. guide pipe approx - 10 M(c S.S. chain with shackles approx - 12 M(d) C.I.D.F. bend 200 mm dia x 900 - 1 No. (e) Submersible cable - 30 M 43 0.415 KV L.T. outgoing panel for pumping plantL.T. control panel having 2 Nos. Bus coupler and 8 Nos. outgoing panels or incoming/ outgoing will be considered as per requirement of work suitable to operated on 415 ± 6% Volt, 3 phase, 50 Hz, AC supply as per details given below-A- 2 Nos. Bus coupler (1 No. for D.G. set and 1 No. for power supply from LT end) each consisting of following items -1600 amp ACB - 1 No.C. Ts of suitable ratio - 1 No. Ammeter with selector swich - 1 No. Voltmeter with selector switch - 1 No.Power factor meter (0.5 Lag & 0.5 Lead)-1 No Frequency meter - 1 No.KWH meter - 1 No.2 Pole over current relay & one plore earth fault relay 1 No.B- Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size - 1 No. C- 6 Nos. composite panels for pumping plants (06 Nos for P.P. & 02 No. spare) each consisting of following items-160 amp MCCB - 8 Nos.A.Ts of suitable ratio - 1 No. Ammeter with selector swich - 1 No.Power capacitor controlled by main switch of suitable rating - 1 No. Thermal over load protection - 1 No.Reverse rotation trip device - 1 No.Automatic start/stop device according to level in the sump - 1 No. Indicating lamps (Auto/manual/low level/reverse rotation) - 1 set3 Nos. panels for miscellaneous works, each consisting of following items-MCCB of 100 amp capacity - 2 No. C. Ts of suitable ratio - 1 No.Ammeter with selector swich - 1 No.Indicating lamps - 1 set1 Nos. outgoing panels for miscellaneous works, each consisting of following items- MCCB of 63 amp capacity - 1 No. C. Ts of suitable ratio - 1 No.Ammeter with selector swich - 1 No. Indicating lamps - 1 set 44 Starter 45 SOFT starter suitable for operation on 380 ± 10% volts, 3 phase, 50 Hz,AC supply suitable for starting and running of 45 HP electric motor and 8 to 12 starts and stops Hr. 46 running of 45 HP electric motor and 8 to 12 starts and stops Hr. 47 Main Pipe, Valves and special 48 MotoroperatedC.I.D.F.risingspindletype,sluicevalvewith actuators conforming to IS: 14846 suitable for sewage application of following size. 49 200 mm dia size 50 450 mm dia size 51 C.I.D.F. Reflex valve conforming to IS : 5312 suitable for sweage applicable of folllowing size. 52 200 mm dia size 53 450 mm dia size 54 C.I.D.F. dismantling joint of following size 55 200 mm dia size 56 450 mm dia size 57 C.I. Pipes and specials - 58 150 mm x 200 mm dia C.I.D.F. Enlarge - Nos. 59 200 mm dia C.I.D.F. pipe 60 450 mm dia C.I.D.F. pipe 61 200 mm dia 900 C.I.D.F. bend 62 450 mm x 300 mm x 200 mm dia C.I.A.F. Tee 63 450 mm dia C.I. blind flange 64 Necessary MS, Nut-Bolt and washer 65 Necessary SS, Nut-Bolt and washer 66 Necessary rubber packing of suitable size 200 mm and 300 mm 67 H.O.T. Crane 68 Provision of H.O.T. crane of 5 ton capacity along with gantry girder and chainpully block and geared trolly suitable for 4.5 meter span and 10 meter clear lift complete in all respect for circular pump house suitable for 7 meter travelling lenlgth for installation of pumping plant. 69 Sewage level regulator/controller 70 Provision for ultrasonic level regulator/controller for measuring sewage level in the sump suitable for indication of low and high level in mtrs. 71 Electromagnetic flow meter 72 Provision for 450 mm dia electromagnetic flow meter complete with display unit including power cable installlation teting & commissioning. 73 Pressure Transmitter 74 Pressure gauge complete with necessary Cu. Tubing, stop cock and necessary fittings suitable for sewage applicable. 75 Power and control cable 76 Supply & laying of 1100 volt grade, 2x625 sqmm 3.5 core, Armored, Al conductor size of XLPE cables required for power wiring form L.T. Panel of sub station to L.T. panel of Pump 77 Supply & laying the 2 x 625 sqmm 3.5 core Armored, Al Conductior size ofXLPE cables required for power wiring form L.T. Panel of pump house sto starters. 78 Earthing 79 Double earthing of all electrical equipments as per latest IER specification complete with slat, charcoal, G.I. earth electrodes, watering pipe, C.I. earth boxes and G.I. earth strips of suitable of size. 80 Construction fo foundation for pumping plants, starters and panels 81 Installation of Pumping plants and all related equipments at site. 82 Commissioning of all pumping plants and related equipments at site. 83 Testing of Pumping Plants 84 At Works 85 At Site 86 Painting of all equipments 87 Internal and external electrification of pump house, substation room and campus. 88 Spares pump set/starter and spare parts 89 Spare pump of 90 LPS/20 m head/45 H.P. - 1set 90 Starter for above pump - 1 set 91 Impelle set - 1 No. 92 Shaft - 1 No. 93 Mechanical Seal - 2 Nos. 94 Upper and lower ball/thrush bearing - 2 Nos. 95 Auto Coupling - 1 No. 96 Spare part for L.T. panel and starter 1 set 97 Tools & spanners 98 Heavy duty pipe wrench 450 mm size - 2 Nos. 99 Screq wrench 350 mm size - 2 Nos. 100 Ring Spanners - 1set 101 DE spanners - 1 set 102 Socket wrench with tommy bar and sockets of diff. size - 1 set 103 insulated piler -2 Nos. 104 Scrow driver - 2 Nos. 105 Hammer with handle - 2 Nos. 106 hexaframe - 2 Nos. 107 Sprit level - 1 No. 108 Miscellaneous items required 109 L.T. magger with testing lead - 1No. 110 Tong tester for measuring of electrical quantity - 1No. Fire Extinguisher - 4 Nos 111 12 mm thick electric resstant rubber matting for LT equipments - 8Nos. 112 20 mm thick electric resistance rubber matting for HT equipments - 2 Nos. 113 Portable electric drill machine with complete range fo drill bits. - 1 No. 114 Manually operated crimping tool with complete range of dies upto 100 sqmm size cable - 1 No. 115 Portable deqatering submersible pump set complete wth starter, delivery pipes and other accessories - 1 No. 116 Steel almirah for keeping records and spares - 2Nos. Steel table with sunmica top - 1 1 No. 117 Steel chair - 4 Nos. 118 Chequered plate of required size to cover all cable trenches in pump house and substation - 1 Lot. 119 Provision of C. I. sluice Gate Conferming to IS 13349 or AWWac- 501 having F shapped wall thimble of C.I. spindle 120 Provision for Mini Tubewell with 100 mm PVC pipe including Cora 100 Submersible pump for campus water requirement complete in all respect. 121 Pole mounted Solar LED 1*18 W Street lighting Fixture installation 122 Mechancial coarse screen with conveyour belt taking as one stand by 20 mm opening. 123 (Belt Conveyor -600 mm width) 124 Miscellaneous Works 125 Installation of DG sets at intermediate pumping station (I.P.S.) [SCHEDULEOFWORKFORINSTALLATIONOFDGSETSATMAINSEWAGEPUMPINGSTATION(M.P.S.) 126 Supply of silent type DG set, engine, alternatorcapable of developing 180 KVA at 415 + 6%volts,50 Hz AC at 0.80 P.F. logging and self exciting coupled with suitable BHP diesel engine connected with flexible coupling and mounted on common base plate complete withfuel tank inside the acoustion system and in built control panel 12 voltleadacide battery with leadsilencer manual control panel & AVM pads D.G.Set shall be mounted in open sky resting on thefoundationasperthedesign. 127 SuitableAMFpanelfloormountingtypecomprising of Ammeter/ Voltmeter with slector switch,power factor meter,shortcircuit protection, mainsupply voltage monitor shortcircuit protection relay, selector switch auto/manual/off, indicating lamps, push buttonstart/stop/re-setetc. 128 Anti-Vibrationmountings 129 Exhaustpipe,fuellineandfueltank 130 SparepartsforD.G.set 131 CompletepowerwiringandearthingofD.G.setand AMF panel as per IER specification withnecessary power and control cable, salt,charcoal,G.I.earthelectrodes,wateringpipe, C.I.earthboxesandG.I.earchstripofadequate size. 132 ConstructionoffoundationofD.G.setandAMF panel. 133 InstallationofD.G.setandotheraccessories includingcommissioningandtesting. 134 MiscellaneousWorks 135 E-INSTALLATION OFSCADA/ AUTOMATION AT INTERMEDIATEPUMPING STATION (I.P.S.) 136 GSM/GPRS Based Remote Terminal Units With analog and Digital parameter and features as specified to store and transmit data on GSM backbone to MCS (1 no. IRTU for 2 Pumps) and should able to send & recived SMS from registered mobile parallel mode. 137 GSM/GPRS based wireless communication hardware for RTUs capable to transfer data from remote site to MCS with all accessories and should able to send & recived SMS from registered mobile parallel mode. 138 Intelligent energy meters 139 Auto Phase reversal unit with inbuilt time delay & enclosure (Confirms to IEC: 60947- 1 & IEC : 60947-6-1) of rating 400 Amp. 140 Complete cabling for 6 pumps 141 Security Survelliance IP Camera 142 After completion of the work, one year maintenance and operation of I.P.S 143 Chaukidari(365x3) 144 Pump Operator (365x3) 145 Electrition(365x2)

Key Value

Document Fees
INR 8260 /-
EMD
INR 843000.0 /-
Tender Value
INR 4.21 Crore /-