| 1 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\"PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythenpipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish.(Average run 12 mtr) |
| 2 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 3 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 4 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required |
| 5 | Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tacklesfor25 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 6 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. As required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 7 | Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 10 | Supplying and fixing following modular switch 5/6 A switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | Supplying and fixing following modular switch 15/16 A switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | Supplying and fixing following modular 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | Supplying and fixing following modular 6 pin 15/16 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of 3x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required |
| 16 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required with 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC. |
| 17 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for 30 cm Exhaust fan (12\") |
| 18 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of 30 cm (12\") |
| 19 | Supply onlyheavy duty 1400 rpm 300 mm sweepExhaust Fan.(Orient Make). |
| 20 | Supply and fixing of slim design recessed squar polycarbonated housing down light with superior lightand integral driver, effiency 100 lm/w Crompton Cat No-LSDEP-12-CDL or equivalent. |
| 21 | Supply and fixing of LED spot light Crompton Cat No-CDR-210-03-30/40-SL-NWH or equivalent. |
| 22 | Supply and fixing of LED compact tube lighteffiency 100lm/wCrompton Cat No-CCS-102-20-65-SL-DP-NWH or equivalent. |