Tender For Supply, Installation And Commissioning For Cctv Project At Sess Palayam Kottai Tender For Supply, Installation And Commissioning For Cctv Project At Sess Palayam Kottai , Supply, Installation & Commissioningfor Cctv Project At Sess Palayam Kottai , Supply Of 2Mp Fixed Dome Camera. Indoor Fixed Dome Camera ( Ip Based Hdtv ) With Built-In Ir-Leds Source For Day / Night Surveillance With Poe And Necessary Accessories Like Ceiling / Wall Mount And Power Supply Adapter As Per The Detailed Technical Specification. , Supply Of 2Mp Vf Bullet Camera .Outdoor Bulletcamera (Ip Based Hdtv) With Built-In Ir-Leds Source For Day / Night Surveillancewith Poe And Necessary Accessories Like Pole Mount And Power Supply Adapter As Per The Detailed Technical Specification. , Ptz Dome Camera.Outdoor Speed Dome Ptz Camera With Day/Night Vision And Built In Ir Illuminators With Necessary Accessories Like Wall / Pole Mount And Power Supply Adapters As Per The Detailed Technical Specification. , Ptz Dome Camera.. Outdoor Heavy Duty Pan & Tilt (Pt) Head Unit With Zoom Camera With Builtin Ir Illuminators With All Necessary Accessories Like Midspan, Wall / Pole Mount And Power Supply Adapters As Per The Detailed Technical Specification. , Pa System Outdoor Network Horn Speaker Along Wih Accessories Like Pole Mount As Per The Detailed Technical Specification. , Ip Programming Mic As Per The Detailed Technical Specification. , Rack Mount Network Server, 2 X Xeon Silver 4310 Along With Keyboard, Mouse, Storage Os , Anti- Virus (For 8 Years) As Per The Detailed Technical Specification. Note: 1. One Server Shall Be Configured As Recording Server And Other Shall Be Configured As Management / Failover Recording Server. Redundancy Considered Only For Recording Server. 2. Retention Period For Failover Recording Server Should Be 7 Days. , Primary Storage Box For 30 Days Recording With 50 Tb Usable Capacity And As Per The Detailed Technical Specification. , Video Management Software (Vms) With 100 Cameras License (Minimum 8 Yrs. Maintenance) And Scalable Up To Unlimited Cameras License To Install In Two Servers. Onvif Compliant. High End / Corporate Version For Centralized Management For Managing The Multi-Sites Of Different Networks And Different Oem Cameras And As Per The Detailed Technical Specification. Note: 1. One Server Shall Be Configured As Recording Server And Other Shall Be Configured As Management / Failover Recording Server. Redundancy Considered Only For Recording Server. 2. Retention Period For Failover Recording Server Should Be 7 Days. , Desktop Workstations For Client Monitoring Along With I7 Series Latest Processor Or Better, Keyboard, Mouse, Active Speakers, Dvd-Rw Combo, Os Windows 11, Antivirus (For 8 Years) As Per The Detailed Technical Specification. , Monitors 27 Inch Size For Client Workstations As Per The Detailed Technical Specification. , Rack Mount Monitor (Rkm) 17 Inch Size For Servers As Per The Detailed Technical Specification. , 8- Port Rack Mount Keyboard (Kvm) Switch As Per The Detailed Technical Specification. , Network Switch 24/28-Port L3 Manageable & Stackable Combo Switch As Per The Detailed Technical Specification. , Network Switch 24-Port L2 Poe Enabled Manageablewith Minimum 4 Sfp Portas Per The Detailed Technical Specification. , Network Switch 28-Port Sfp Switch For Distribution With Minimum 4 Nos Fiber Uplink As Per The Detailed Technical Specification. , Single Mode Dual Fibre 1G Sfp Module As Per The Detailed Technical Specification. , 1G Copper Module As Per The Detailed Technical Specification. , Midspan For Indoor Cameras & Sip Mic As Per The Detailed Technical Specification. Poe + Injector , Midspan For Outdoor Fixed Cameras And Ptzs, Speakers As Per The Detailed Technical Specification. Poe + + Injector , Sfp Modules For Outdoor Cameras Midspans As Per The Detailed Technical Specification. , Ethernet (Lan) Surge Protectors As Per The Detailed Technical Specification. , Single Pole Surge Protectors For Power Line As Per The Detailed Technical Specification. , Indoor Power Distribution Box With 4 Mcbs As Per The Detailed Technical Specification. , Indoor Wall Mount 12U Height Equipment Rack, 550Mm Width X 600Mm Depth And As Per The Detailed Technical Specification. , Server Rack 42U Height With Wheels, 800Mm (Width) X 1000Mm (Depth), Two Powerstrips, 10 Pair L-Angles, Equipment Tray 4 Nos, Front Glass Door And Other Accessories As Per The Detailed Technical Specification. , Weather Proof Outdoor Pole Mount Junction Box With Ip 66 Rated And All Ss Screws & Nuts As Per The Detailed Technical Specification. , 6A Mcb 2 Pole Miniature Circuit Breakers 9 Ka / 10 Ka Breaking Capacity With Universal Screw Conforming To Is 8828 With Latest Amendments As Per The Detailed Technical Specification. , Rccb 1 No 2 Pole 25 A 240Vip 20 Protected Terminals With 35 Sq Mm Terminals Confirming To Is Standards Part No 4118 51 As Per The Detailed Technical Specification. , Hotdip Galvanized Outdoor Pole (6M Height) And All Ss Screws & Nuts As Per The Detailed Technical Specification. , Pole Earth Kit As Per Is- 3043 Standard And All Ss Screws & Nuts As Per The Detailed Technical Specification. , Pole Earth Kit As Per Is- 3043 Standard And All Ss Screws & Nuts For Terrace Camera As Per The Detailed Technical Specification. , Cat 6 Utp Cable (Unarmored) As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , 6 Core Ofc Single Mode (Armored)As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Power Cable 3 Core 6.0 Sqmm (Armored), Isi/Iso Mark As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Power Cable 3 Core 1.5 Sqmm (Unarmored), Isi/Iso Mark As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Power Cable 3 Core 2.5 Sqmm (Unarmored), Isi/Iso Mark As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Power Cable 2 Core 4 Sqmm (Armored), Isi/Iso Mark As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Prefabricated Polyethylene (Plb Hdpe) Pipe, Isi/Iso Markas Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Cat-6 Lan Stp Patch Cords 5M Length As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Cat-6 Lan Stp Patch Cords 2M Lengthas Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Cat-6 Lan Patch Cords 5M Lengthas Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Cat-6 Lan Patch Cords 2M Lengthas Per The Detailed Technical Specification. (Actuals / Variable Quantity) , 2 Core Single Mode Ofc Patch Cords, 2M Length, Lc-Lc Duplex Connectors (As Per Site Condition) As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , 2 Core Single Mode Ofc Patch Cords, 3M Length, Lc-Lc Duplex Connectors (As Per Site Conditionas Per Site Condition) As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Fully Loaded 6 Port Liu (Including Splicing Tray, Lc-Duplex Adapter, Pig Tails Etc.) To Mount Inside Outdoor Junction Box As Per The Detailed Technical Specification. , Fully Loaded 24 Port Liu (Including Splicing Tray, Lc- Duplex Adapter, Pig Tails Etc.)Rack Mount As Per The Detailed Technical Specification. , 12 Port Liu As Per The Detailed Technical Specification. , Cat 6 24 Port Utp Patch Panel Rack Mount As Per The Detailed Technical Specification. , Pvc Channel (18Mm Size) As Per The Detailed Technical Specification For Routing The Indoor Cat-6 Lan Cables And Power Cables.(Actuals / Variable Quantity) , Pvc Pipes 25Mm Diameter As Per The Detailed Technical Specification For Routing The Indoor Cat-6 Lan Cables And Power Cables, (Actuals / Variable Quantity) , Standard Cable Route Markers As Per The Detailed Technical Specification. (Actuals / Variable Quantity) , Labour Works/Charges For Splicing Of Ofc Cable Cores (Actuals / Variable Quantity) , Labour Charges For Laying The Hdpe Pipe (Actuals / Variable Quantity) , Labour Charges For Laying The Ofc Cable In The Hdpe Pipe (Actuals / Variable Quantity) , Labour Charges For Laying The Armored Power Cable In The Hdpe Pipe (Actuals / Variable Quantity) , Laying Of 3 Core 1.5 Sq.Mm Unarmoured Power Cable , Laying Of 2 Core4 Sq.Mm Armoured Power Cable , Labour Charges For Laying Cables In The Existing Cable Trench At Indoor And Outdoor Areas (Actuals / Variable Quantity)Cat 6 , Labour Charges For Fixing The Pvc Channels And Routing The Lan Cables (Actuals / Variable Quantity) , Labour Charges For Fixing The Pvc Pipes And Routing The Power Cables (Actuals / Variable Quantity).Pulling 25 Mm Pvc Pipe. , Labour Charges Fixing Of Cable Route Markers (Actuals / Variable Quantity) , Labour Charges For Pit Digging In Hard Soil (Earth Work) Of Size 400Mm (Width) By 750Mm (Depth) For Routing The Hdpe Pipe And Re- Filling Mud After Laying The Pipe (Actuals / Variable Quantity) , Labour Charges For Pit Digging In Hard Soil (Earth Work) Of Size 600Mm (Width) By 600Mm (Length) By 1000Mm (Depth) For Erection Of The Outdoor Poles And Filling With Cement Concrete And Properlybed Finish Above Ground Level. And Also Cable Ducts (Pipes) Should Be Done In The Concrete Bed For Routing The Cables (Actuals / Variable Quantity) , Labour Charges For Earth Pit Digging In Rocky Soil To Carryout Earthing For Outdoor Poles (1M Away From Poles), Wiring And Finishing With Confirming To Is- 3043 Standard (Actuals / Variable Quantity) , Labour Charges For Plate Earthing For Heavy Duty Ptz Located In Terrace, Wiring And Finishing With Confirming To Is- 3043 Standard (Actuals / Variable Quantity) , Installation, Testing, Commissioning, Integration And Configuration Of Cctv Surveillance System. Installation Charges Which Includes Termination Of Cables, Fixing Of Cameras, Installation, Erection Of Poles, Testing, Configuration, Documentation And Commissioning. , Training Of Dept Personnel At Site (3 Years) 1St Year , 2Nd Year , 3Rd Year , Warranty For The System (3 Years) After Installation & Commissioning1st Year , 2Nd Year , 3Rd Year , Training Of Dept Personnel At Site (4-8 Years) 4Th Year , 5Th Year , 6Th Year , 7Th Year , 8Th Year , Camc For 5 Years (After 3 Years Of Standard Warranty)1St Year , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year