| 1 | Erection of 11/.04 KV ,100 KVA Distribution S/Stn :- |
| 2 | Prov. Distribution Transformer 11/.4KV, 100KVA |
| 3 | Prov. S/T Pole 9 Mtr W/L >200 kgf/m2 |
| 4 | Prov. RCC Muff with concrete filling |
| 5 | Prov. X-arm: C.I (100x50X6 mm ),Length: 2800 mm x 2 Nosfor incommer line |
| 6 | Prov.MS A.I X-arm (50x50x6 mm), Length: 2800 mm x 1 No for LA\"s |
| 7 | Prov. X-arm: C.I (75x40X6 mm ),Length: 2800 mm x 4 Nosfor supporting DO Fuse unit & GO switch |
| 8 | Prov. Transformer Bed ,Belting and Knee Bracing |
| 9 | Prov. X-arm: C.I (100x50X6 mm ),Length: 2800 mm x 2 Nosfor T/F Bed |
| 10 | Prov. X-arm: C.I (100x50X6 mm ),Length: 460 mm x 2 Nosfor supporting main channel of T/F |
| 11 | Prov.MS A.I X-arm (50x50x6 mm), Length: 2800 mm x 2 Nos |
| 12 | Prov.MS A.I X-arm (35x35x5 mm), Length: 460 mm x 2 Nos |
| 13 | Prov.MS A.I X-arm (50x50x6 mm), Length: 950 mm x 2 Nos for Bed Knee Bracing |
| 14 | Prov. Transformer LT Distrubution Box and GO switch fixing Assembly |
| 15 | Prov.MS A.I X-arm (50x50x6 mm), Length: 2800 mm x 2 Nos |
| 16 | Prov.MS A.I X-arm (50x50x6 mm), Length: 450 mm x 1 Nos |
| 17 | Prov. G.OSwitch handle supporting C.I (75x40x5 mm), Length: 460 mm x 1 No |
| 18 | Prov. G.OAB Switch unit Triple pole o/d type |
| 19 | Prov. D.O Fuse unit |
| 20 | Prov. Lightning Arrestor/Surge Arrester, 9 Kv station class ( porcelain type) |
| 21 | Prov. Disc Insulator Sets (comprissing 1 no. disc(porcelain,BS,12kV, 90 Kn) i/c dead end clamps etc. ) |
| 22 | Prov. Stay set complete |
| 23 | Prov Stay wire 7/3.15mm (6.0 kg/stay set) |
| 24 | Prov. Pipe Earthing Set |
| 25 | Prov. LT Distn Panel Box with MCCB(160 A,10 kA,4P,1 no.)& SFU(32 A,5nos. rewirable) |
| 26 | Prov. Half Clamp |
| 27 | Prov. Full Clamp |
| 28 | Prov. M.S Nuts & BoltOff size (Galvanised/coated) |
| 29 | Prov. Aluminium Thimble |
| 30 | Prov. Aluminium Thimble |
| 31 | Prov. Danger Plate |
| 32 | Prov. Barbed Wire |
| 33 | Prov. LT Cable 3.5 core 120 mm sq |
| 34 | Prov. Energy Meter 3 Ph 4 wire ( CT Operated static trivecter meter with Box(CT-100-200/5A) |
| 35 | Prov. Aluminium Paint |
| 36 | Plinth with CC of 1:2:4around the str with Boulder filling at the base & other civil works required at the site |
| 37 | Transformer Bed ( Civil work) |
| 38 | Chain Link Fencing , Angle iron, gate etc. for T/F fencing |
| 39 | Add Transportation Charges Complete in all respect |
| 40 | Add Erection Charges Complete in all respect |
| 41 | 11KV Metering Equipment ( Outdoor Type) |
| 42 | Prov. CT/PT Combined Unit (PT:11KV/110V)(CT:10-400/5Amp) |
| 43 | Prov. 3-Ph, 3/4-wire CT-PT operated statictrivector meter DLMS Compliant |
| 44 | PVC Multistrand copper wire with 1inch dia G.I Pipe for concealing |
| 45 | Prov. M.S A.I X-arm( 2800x50x50x6mm)x4 |
| 46 | Prov. M.S A.I X-arm( 460x35x35x5mm)x2 |
| 47 | Prov. Nuts & Bolt Off size |
| 48 | Prov.Aluminium Paint |
| 49 | Prov.Red Oxide |
| 50 | Add Transportation Charges Complete in all respect |
| 51 | Add Erection Charges Complete in all respect |
| 52 | 11 KV H.T Line |
| 53 | Prov. AAAC 7/3.15 mm |
| 54 | Prov. Single continous Earth wire (G.I,8 SWG) |
| 55 | Add Transportation Charges Complete in all respect |
| 56 | Add Erection Charges Complete in all respect |
| 57 | LT Line |
| 58 | prov. LT AB acble (3x95+50)mmsq |
| 59 | Prov. ST Pole 8 Mtr.W/L 180 Kgf/m2 |
| 60 | Prov. RCC Muff with concerete filling |
| 61 | Prov. X-arm M.S C.I 100x50x6 length 600mm |
| 62 | Prov. Faced Hook |
| 63 | Prov. LT Stay set Complete |
| 64 | Prov. LT Stay wire7/3.15mm |
| 65 | Prov. Full Clamps (2 No for A.I + 1 No for Stay Set) |
| 66 | Prov. Earthing Set complete |
| 67 | Prov. M.S Nuts & Bolt off size |
| 68 | Prov. Aluminium Paint |
| 69 | Prov. Red Oxide |
| 70 | Add Transportation Charges Complete in all respect |
| 71 | Add Erection Charges Complete in all respect |