}

Tender For Drinking Water Facility At Bhatiapara Near Punb Bank Part No 49, Drinking Water Facility At Bhatiapara Near Punb Bank Part No 49 Under Salbari - Ii Gp (Activity Code : 90537439) Sl. No. Item Description 1 Labour For Boring Tube Well Of Re, Jalpaiguri-West Bengal

Local Bodies has published Tender For Drinking Water Facility At Bhatiapara Near Punb Bank Part No 49, Drinking Water Facility At Bhatiapara Near Punb Bank Part No 49 Under Salbari - Ii Gp (Activity Code : 90537439) Sl. No. Item Description 1 Labour For Boring Tube Well Of Re. Submission Date for this Tender is 30-07-2024. Tanks and Cylinders Tenders in Jalpaiguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

44310994
Tender For Drinking Water Facility At Bhatiapara Near Punb Bank Part No 49, Drinking Water Facility At Bhatiapara Near Punb Bank Part No 49 Under Salbari - Ii Gp (Activity Code : 90537439) Sl. No. Item Description 1 Labour For Boring Tube Well Of Re
Open Tender
Indian
West Bengal
Jalpaiguri
30-07-2024

Tender Details

Tender For Drinking Water Facility At Bhatiapara Near Punb Bank Part No 49, DRINKING WATER FACILITY AT BHATIAPARA NEAR PUNB BANK PART NO 49 UNDER SALBARI - II GP (ACTIVITY CODE : 90537439) Sl. No. Item Description 1 Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.(i)50 mm dia. boring etc. 2 (ii) 100 mm dia. boring etc. top enlargement 3 Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications.(ii)50 mm dia. 4 Supplying, fitting and fixing plug of approved make conforming to I.S. specifications.(ii)50 mm 5 Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.(vi)50 mm 6 Supplying, fitting and fixing heavy type bell mouth reducing socket.(i) 50 mm X 100 mm 7 Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. 8 Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.)(d) 32 mm dia.(ii) Medium quality 9 (f) 50 mm dia. (ii) Medium quality 10 (i) 100 mm dia. (i) Medium quality 11 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than 22.5 Kg./m 12 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1.500 mm.4x1.05x1.05x1.5=6.62cum 13 (II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. VarietyIn ground floor(a) 1:3:6 proportion 14 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(ii ) River Bazree 15 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. 16 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel II. Other than SAIL/TATA/RINL 17 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(a) For Exposed Work(ii) CPVC Pipes Class-2,SDR-13.5From Storage Tank to Stand Post25 mm 18 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 1500 litre capacity 19 (g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm.(i) 15 mm 20 ((b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) 21 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) 22 Supply , transport , installation and commissioning of Solar PV installation for water pumping system with fixed structure consisting of solar panels framed in anodized aluminium frame mounted on stable hot dipped galvanized (with80 micron thickness) mild steel structure of sufficient strength which can withstand load of modules and high wind velocities upto 150 Km/hr, having RCC foundation designed against all possible loads (Dead, Live and imposed load). Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent National or International standards and must be interconnected with 4/6 sq.mm cables routed in PVC conduits properly fitted along the G.I structure to provide a good aesthetic view. Modules must qualify to IEC 61730 part I and part II for safety qualification testing. The power output of individual PV modules used in the PV array, under STC, should be a minimum of 250 Watts peak, with adequate provision for measurement tolerances. Solar cells should be crystalline silicon cell with min. efficiency of 14% and fill factor more than 70%, should be laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass including appropriate DC to AC inverter and power controlling unit (protected with IP65 class enclosure) with MPPT technology to run at low sunshine and minimum 5 hours a day run with all necessary accessories suitable for solar + grid operation and including all protections of AC induction motor pump. There should be a display of all measurable parameters including storing of data at a set interval and transfer it in a pendive thru USB port . There should also be provision of interfacing GPRS based data transmission. (The rate is inclusive of manufacturers warranty and comprehensive maintenance for 1st year and comprehensive maintenace for 4 years beyond Ist year) 23 Supplying , fitting and fixing of Sand Filter - Manual as per IS:14606Sand Filter10m³/hr-M Single 24 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe 25 Connecting the equipment to the earth busbar incl. S&F GI wire of size bellow on wall /floor as required and making connection to the equipment with bolts, washers, cable lugs etc. as required and mending good damages.No 4 SWG GI wire 26 Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.)(b) 30 cubic metre per hour capacity electro motor pumping set.(i) Length of pump assembly not exceeding 18 metre length 27 Supplying 1 m × 0.6 m × 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house. 28 Supply of 1 HP oil fill AC solar submersible pump motor set complete having suitable dischage as per yeld test of well. Submerisble cable of 30mtr 3 core 2.5 sqmm that cable (Finolex) with MOC bar chart (Kriloskar make Pump)(Rate As per Quotation) 29 Add GST 18%% 30 Add 1% Cess

Key Value

Document Fees
INR 2000 /-
EMD
INR 7000.0 /-
Tender Value
INR 3.49 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail