Modular Operation Theatres Type B , Sitc Of Wall Construction - Ppgi - 100 Mm As Per Technical Specifications , Sitc Of Ceiling Construction - Ppgi- 50 Mm As Per Technical Specifications , Sitc Of Wall Construction - Ppgi - 50 Mm As Per Technical Specifications , Sitc Of Wall Construction - Ss 304 - 100 Mm As Per Technical Specifications , Sitc Of Ceiling Construction - Ss 304 - 50 Mm As Per Technical Specifications , Sitc Of Wall Construction - Ss 304 - 50 Mm As Per Technical Specifications , Sitc Of Wall Construction - Hpl - 100 Mm As Per Technical Specifications , Sitc Of Ceiling Construction - Hpl - 50 Mm As Per Technical Specifications , Sitc Of Pvc Flooring - Operation Theatre - Antistatic As Per Technical Specifications , Sitc Of Pvc Flooring - Connecting Corridors As Per Technical Specifications , Sitc Of Viewing Window - Hermetically Sealed As Per Technical Specifications , Sitc Of Control Panels For Operation Theatreas Per Technical Specifications , Sitc Of Operating List Board - Ceramic As Per Technical Specifications , Sitc Of X-Ray Viewing Screen - Led As Per Technical Specifications , Sitc Of Scrub Station - Ss - 3 Baywith Automatic Sensor As Per Technical Specifications , Sitc Of Scrub Station - Ss - 2 Bay With Automatic Sensor As Per Technical Specifications , Sitc Of Storage - Ppgi As Per Technical Specifications , Sitc Of Storage - Ss 304 As Per Technical Specifications , Sitc Of Storage - Hpl As Per Technical Specifications , Sitc Of Door And Frames (Hermetically Sealed Type) – Automatic As Per Technical Specifications 2.1 (H) X 1.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Automatic As Per Technical Specifications 2.4 (H) X 1.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Automatic As Per Technical Specifications 2.1 (H) X 1.5 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Automatic As Per Technical Specifications 2.4 (H) X 1.5 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Automatic – Lead Lined As Per Technical Specifications 2.1 (H) X 1.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Automatic – Lead Lined As Per Technical Specifications 2.4 (H) X 1.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing As Per Technical Specifications 2.1 (H) X 1 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing As Per Technical Specifications 2.1 (H) X 0.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing - Lead Lined As Per Technical Specifications 2.1 (H) X 1 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing - Lead Lined As Per Technical Specifications 2.1 (H) X 0.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing As Per Technical Specifications - 2.1 (H) X 1.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing As Per Technical Specifications - 2.4 (H) X 1.8 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing As Per Technical Specifications - 2.1 (H) X 1.5 (W) , Sitc Of Door And Frames (Hermetically Sealed Type) – Swing As Per Technical Specifications - 2.4 (H) X 1.5 (W) , Sitc Of Ot Pendant – Surgeons As Per Technical Specifications , Sitc Of Ot Pendant – Anesthesia As Per Technical Specifications , Sitc Of Peripheral Lights & Clean Room Luminaries As Per Technical Specifications , Sitc Of Distribution Box & Electrical Cabling Works From Panel As Per Technical Specifications , Sitc Of Isolation Panel System As Per Technical Specifications , Sitc Of Internal Wiring Works Including Switch, Sockets, Information Outlets Including Cabling Works Inside Individual Operation Theatre Etc.As Required , Supply And Laying Of Required Power & Elv Cables From Distribution Board To Individual Operation Theatre , Sitc Of Pressure Relief Dampers , Sitc Oflaminar Air Flow System With Hepa Filter , Sitc Ofinternal Hvac Ducting & Exhaust System , Hv Air Conditioning System - Ahu, 11 Tr (5.5Trx2)Outdoor Unit, Humidity Control, Complete Ducting, Power Cabling, Mcb, Etc As Per Specifications For One Theater , Sitc Of Hatch Pass Box Active, Ss 304, 600 X 600 Mm , Laying And Connectingrequired Power Cable From The Sub-Power Panel To The Hvac Unit , Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , Sitc Of Ot Light Led - Double Dome With Camera Provision (Not Taken For Evaluation) , Sitc Of Ot Light Led - Triple Dome With Camera Provision (Not Taken For Evaluation) , Sitc Of Wireless Hd Camera For Ot Light Dome (Not Taken For Evaluation) , Additional Third Arm For Two Dome Ot Light Without Camera Or Tv (Not Taken For Evaluation) , 32 Hdtv With Attachmentfor Connecting With Third Arm (Not Taken For Evaluation) , Sandalone Hd Camera With Attachment For Connecting With Thrird Arm, Cost Shall Include Hd Camera, Attachment With Thrid Arm And Other Standard Accessories (Not Taken For Evaluation) , Sitc Ofair Handling Unit – Ahu For Chilled Water Plant (Not Taken For Evaluation) , Sitc Ofheater Coils In The Already Available Air Conditioning System , Hv Air Conditioning System - Ahu, 8.5 Tr (4.5Tr+ 4Tr) Outdoor Unit, Humidity Control, Complete Ducting, Power Cabling, Mcb, Etc As Per Specifications For One Theater , Hatch Pass Box Passive, Ss 304, 600 X 600 Mm (Not Taken For Evaluation)