}

Tender For Electrification Work In Shc At Lambata, Dist. Dungarpur., dungarpur-Rajasthan

Government Departments has published Tender For Electrification Work In Shc At Lambata, Dist. Dungarpur.. Submission Date for this Tender is 25-07-2024. Electrification Work Tenders in dungarpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

44250422
Tender For Electrification Work In Shc At Lambata, Dist. Dungarpur.
Open Tender
Indian
Rajasthan
Dungarpur
25-07-2024

Tender Details

Tender For Electrification Work In Shc At Lambata, Dist. Dungarpur.; 1 Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr..) 5 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modularswitch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge,making connections, testing etc. complete as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 On board 7 Long point(up to 10 mtr..) 8 S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 9 MMS ( IS:9537 P - III ) PVC conduit 10 20 mm 11 25 mm 12 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 13 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4,, in existingsurface or recessed PVC/ MS conduit/casing capping includingall as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 14 2 x 2.5 sq. mm. + 1x1.5sqmm 15 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 16 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 17 Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 18 25mm x 25mm x 3mm 19 Providing & Fixing of phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 20 100 mm dia. 21 P & F 18 swgM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 22 Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load andsite requirement) 4KV impulse withstand voltage,as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted withexisting distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A ratingincluding making connections, testing etc. as required.. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 23 Single pole MCB 24 6 A to 32 A rating 25 Double pole MCB 26 6 A to 32 A rating 27 Four pole MCB 28 50-63 A rating 29 Providing & Fixing of metal clad industrial plug top & socket unit with pin and sleeve type copper contact on porcelain/ bakelite base insheet steel( CRCA )powed coated enclosure as per PWD specificationfor electrical Worksconforming to Is 8623 & IEC 61439-3 (without MCB) including , all as per pre approved by Engineer in charge,making connections,, testing etc.as required .OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 30 20 A Double Pole(single phase Three pin ) 31 Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thickDistribution board as per PWD specificationfor electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DBterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 32 IP-43 Double door (Single phase) 33 6 Way (6 O/G +2 I/C ) 34 12 Way (12 O/G +2 I/C) 35 IP-43 Double door (Three phase) 36 4 Way ( 12 O/G + 8 I/C ) 37 Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 38 5 step fan regulator 100 watt 2 Module 39 Providing & Fixing ofISI marked(IS:2268-1994) ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- 41 (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I 42 (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . 43 (c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 44 10.00 Sq. mm Armoured cable 45 4 core 46 SITC ofchemical Gel earthing system ofDual Pipe Technology made of with B ClassG I Pipeas per IS 1239 ( part-1):2004of Medium duty of following sizesas per points mentioned (a), (b), [c), (d), (e) below :- 47 (a) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . 48 (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 49 ©Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 50 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 51 (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell 53 GI pipe 2000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip 54 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cuthimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 8 SWG G.I. ( Hot Dipped) Wire 56 Making of hole in wall (brick/stone) of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: 57 Up to 457 mm size 58 Providing & Fixing of ISO Certified company made BEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanas per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V- 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 60 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 225 mm sweep 62 300 mm sweep 63 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 64 Up to 380 mm size 65 Providing & Fixing ofISO Certified company made ISI marked (IS:2082) of 5 star ratedvertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloyconnection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 66 15 Ltr. 67 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coatedhousing with in built driver, Power Consumption of18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. 68 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 69 4 LED Tube shape fixture 18/20 W (Extruded AlBase) 70 Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 71 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 72 Surface Mounting 73 LED Downlight 18/20W 74 Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedand potted driver must be potted & has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certified and T.C. certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. 75 OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture 60 Watt 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply & Fixing of ABC Type (MAP 50)type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, withDry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket includinginitial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printedon the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 4 kg 81 Supplying and Laying ISI marked P.V.C. insulated submersible cable as per PWD specification for electrical Worksconfirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required.OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections.For additional technical parameters of products/ work, referAnnexure A attached with this BSR . 82 4.0 Sq.mm 3 core flat / Round 83 Providing & Laying of synthetic rope for submersible pump ISI marked (IS:5175) of following sizes. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 12mm (suitable up to 50 mm OD pipe) 85 Providing & Fixing of HDPE pipe ISI mark (IS:4984/2016 ) for water supply (suitable for submersible & jet pump) with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 for vertical installation 87 40 mm OD6 kg / cm2 88 Supply Installation testing & Commissioning of Radial / mixed flow ISI marked water filled submersible motor pump setssuitable for 100/150mm dia borewell.The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034:2018 and IS 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011with required accessories including making connection suitable for Bore well. The job includes labour part of lowering ofriser pipe G.I./H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. 90 2.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM 91 Supply Installation testing & Commissioning ofISO certified company made DOL/Star-Delta Starter panel made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 For single phase Submersible / Monoblockpump 93 0.5 HP to 3.0 HP (DOL starter)

Key Value

Document Fees
INR 500 /-
EMD
INR 6440.0 /-
Tender Value
INR 3.22 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail