Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-09-2024 |
| 2 | 30-08-2024 | Due Date Extended for tenders closing on 06-08-2024 | Admin Corrigendum Date Extend | 05-09-2024 |
| Sl. No. | Item Description |
| 1 | Labour only for repair / maintenance of internal light fitting of any type and attendingcomplaints of No light/ceiling fan/ exhaust fan/ geysers/ security light/ ceiling and wall light /Cable fault of any size & type / earth leakage/ short circuit / neutral break mains / substations / internal circuits of existing system of main building / block, making continious electric supply including carrying out minor repairs etc as required to make the system functional including replacingfuse wire, copper thimbles, glands,etc complete all as specified and all as directed by Engr-in-charge. Note:(i)Attending of 01 No. complaints / defects and make it functional shall be measured as one job. (ii) Cost of spares like Driver, lamp holder, connection wire, capacitor etc. replaced against above mentioned item will be measured & paid for separately under respective items of BOQ. (iii)The contractor\"s representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects / complaints and will be submited the completion report on following day before 0900hrs to the JE E/M.(iv) The contractor has to rectify the defects / complaints and make the light fittings functional within 24 hours from the time the list of defectivelights is handed over to him / his rep by the concerned JE E/M.In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill. (v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M. |
| 2 | S & FSwitch piano flushtype, single pole, one way, and 6 Amp, complete all as specified and directed. |
| 3 | S & FSwitch piano flushtype, single pole, one way, and 16 Amp, complete all as specified and directed. |
| 4 | S & F Switch piano flushtype, single pole, 16 Amps two way,complete all as specified and directed. |
| 5 | S & F socket outlet 5 pin, 6 Amp flush type multipurpose complete all as specified and as directed. |
| 6 | S & F socket outlet 2 in 1, 3/6 pin, 6 Amp and 16 Amps multipurpose flush type complete all as specified and as directed. |
| 7 | Supply and fix in replacement of anchor bolt & nut 8 mm dia, suitablr for fixing of geyser on walls in a suitable way and making good the disturbed area complete all as specified and directed |
| 8 | S&F ceiling rose surface bakelite, two to three terminals complete all as specified and asdirected. |
| 9 | S&F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 10 | Taking down carefully exising unserviceable point wiring of any type (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc)for taking credit and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed. |
| 11 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, surface mounted as per site requirement with GI box /PVC surface mounted modular boxwith earth dolly , covered with modular white cover plate with frame suitable for modular switches including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :(a). One light / fan / exhaust fan point controlled byone way switch 5 Amps |
| 12 | (b) One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 13 | (c) One bell point controlled by one switch. |
| 14 | (d) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board. |
| 15 | All as per item No. 11 above but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 ampspoint including necessary running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed |
| 16 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc,heavy duty ISI marked, surface mounted as per site requirement with mild steel sunken boxes / PVC surface mountedbox with earth dolly duly, covered with laminated hylem sheet/ PVC cover , ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-(a). One light / fan / exhaust fan point controlled byone way switch 5 Amps |
| 17 | (b) One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 18 | (c) One bell point controlled by one switch. |
| 19 | (d) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board. |
| 20 | (e) One light point controlled by two way switch |
| 21 | All as per item No.13 above butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 ampspoint including necessary running of2.5 sq mm copper conductorFRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed. |
| 22 | S & F for Modular Switch one way, 6 Amp, 240 volts 1 module, complete all as specified and directed. |
| 23 | S & F for Modular Switch one way, 16 Amp, 240 volts 1 module, complete all as specified and directed. |
| 24 | S & F modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type, complete all as specified and directed. |
| 25 | S & F modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 3 pin, 16 Amp, 2 module piano flush type, complete all as specified and directed. |
| 26 | S & F modular step type fan regulator 120 watt 2 module complete all as specified and as directed. |
| 27 | S & F modular bell push 6 Amps, 1 module, complete all as specified and directed. |
| 28 | S & F bell push 6 Amps, flush type, complete all as specified and directed. |
| 29 | S&F in repairsceiling fan regulator, electronic, flush type, rotary steps, hum free, AC, 230 volts, 100 watts, complete all as specified & directed |
| 30 | S&F in replacement of sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of sizewith 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirmingto IS: 694-1990 with and including continuous earth wire of size 1x10 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessariesISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of wall , making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.Note:-One meter of conduit along with 4x10 sq mm wire and 1x10 sq mm earth shall be measured as one unit length. |
| 31 | S&F in replacement of Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of sizewith 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirmingto IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessariesISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of wall , making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.Note:-One meter of conduit along with 4x6 sq mm wire and 1x6 sq mm earth shall be measured as one unit length. |
| 32 | S&F in replacement of Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of sizewith 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirmingto IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessariesISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of wall , making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.Note:-One meter of conduit along with 2x6 sq mm wire and 1x6 sq mm earth shall be measured as one unit length. |
| 33 | S&F in replacement of Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of sizewith 4 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirmingto IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing caping including fitting in walletcand connected to common earth dollymaking good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.(Note :- One meter of PVC casing caping along with 2x4 sq mm wire and one 4 sq mm earth shall be measured as one unit length) |
| 34 | S&F in replacement of Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.Note :- One meter of PVC casing caping along with two runs of 4 Sqmm wire and one run of 4 Sqmm earth wire shall be measured as one unit length |
| 35 | S&Fin replacement LED building security light fiitting 30 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 36 | M&L for LED panel recess mounted 2\"x2\", 36 watts light fitting with heat exchanger unitcomplete including cutting hole of required size in POP/false ceiling making good the disturbed surfaces including taking down of old unserviceable any type ceiling fitting complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 37 | S&F in repairsLED batten,Neptune silver tube light fitting complete with all fitting and fixing accessories, 4 Feet, 1X20Watt pre-wired with high efficiency electronic driver, glare free, smooth light distribution conforming to complete including taking down any type old unserviceable fitting complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 38 | S&F in repairsLED PL Lamp, 18 watt, 4 pin, indoor decorative LED extruded aluminium (powder coated) anodized with opal diffuser, 2G11 pin, IP20 suitable for existing fitting including taking down of old unserviceable fitting of any type complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 39 | S&F in repairsLED PL Lamp, 10 watt, 4 pin, indoor decorative LED extruded aluminium (powder coated) anodized with opal diffuser, 2G11 pin, IP20 suitable for existing fitting including taking down of old unserviceable fitting of any type complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 40 | S&F in repairsLED recess mounting downlighter 12 watt with LED backlit round downlighter made of PDC AL with high efficient LEDs & glare free opal diffuser, IP20,including taking down of old unserviceable fitting of any type complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 41 | S&F in repairsLED recess mounting downlighter 18 watt with LED backlit round downlighter made of PDC AL with high efficient LEDs & glare free opal diffuser, IP20,including taking down of old unserviceable fitting of any type complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 42 | S&F in replacement LED tube light with diffused optics ultra bright LED tube light 18/20watt with high efficiency suited for installation in existing T8 tube light with G13 lamp holders complete all as specified and directed Make - LUKER / WIPRO / Bajaj / Havells / Philips |
| 43 | S & F in replacement of LED indoor driver suitable forLEDfitting 10 to 35 Watts of the existing make including connection complete all as specified and directed. |
| 44 | S & F replacement ofLED indoor driver suitablr for LED pannel Recess mounted 2\"x2\" - 36 watts of the existing make including making connection etc. complete all as specified and directed |
| 45 | S & F replacement ofLED indoor driver suitablr for LED pannel Recess mounted 2\"x2\" - 50 watts of the existing make including making connection etc. complete all as specified and directed |
| 46 | S&F in repairsIP-43, protection metal double door Vertical TPN -DB rated bus bar, 415 volts, 50 HZ completewith interconnection links, blanking plates, cable ties, identification labelsTPN4 way,12 modules suitable for accommodating 100 AmpsMCCB 4 pole as incomer and SP/TP MCB as outgoing and concealed /surface on wall as per site requirement including all cutting holes in or throughwalls and making good the disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering etc as applicable to the disturbed surfaces to match the existing complete all as specified and directed. Note- MCCB as incomer will be measured and paid separately under respective items of BOQ |
| 47 | S&F in repairsIP-43, protection metal double door Vertical TPN -DB rated bus bar, 415 volts, 50 HZ completewith interconnection links, blanking plates, cable ties, identification labelsTPN8 way,24 modules suitable for accommodating 100 AmpsMCCB 4 pole as incomer and SP/TP MCB as outgoing and concealed /surface on wall as per site requirement including all cutting holes in or throughwalls and making good the disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering etc as applicable to the disturbed surfaces to match the existing complete all as specified and directed.Note- MCCB as incomer will be measured and paid separately under respective items of BOQ |
| 48 | S&F inrepairs, IP-43, MCB DB 4 way, double door, with 100 amp rated bus bar 240 Volts, SPN concealed / surface on wall including cutting holes in or throughwalls, making good the disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering (As applicable) etc to match the existing surfaces, complete all as specified and directed by Engr-in-Charge |
| 49 | S&F inrepairs, IP-43, MCB DB 8 way, double door, with 100 amp rated bus bar 240 Volts, SPN concealed / surface on wall including cutting holes in or throughwalls, making good the disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering (As applicable) etc to match the existing surfaces, complete all as specified and directed by Engr-in-Charge |
| 50 | S&F inrepairs, IP-43, MCB DB 12 way, double door, with 100 amp rated bus bar 240 Volts, SPN concealed / surface on wall including cutting holes in or throughwalls, making good the disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering (As applicable) etc to match the existing surfaces, complete all as specified and directed by Engr-in-Charge |
| 51 | S&F in repair MCCB with rating of 63-100 Amps, 415 Volts 4 pole with 16 KA breaking capacity, thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu) MCCBshould be with suitable spreaders and phase barriers for each terminals, complete all as specified and directed by Engr-in-charge. |
| 52 | Ditto all as per item no 44 above but MCCB 125 Amps, 16 KA, 4 Pole, 415V, complete all as specified and directed. |
| 53 | Ditto all as per item no 44 above but MCCB 160 Amps, 25 KA, 4 Pole, 415V, complete all as specified and directed. |
| 54 | Ditto all as per item no 44 above but MCCB 200 Amps, 36 KA, 4 Pole, 415V, complete all as specified and directed. |
| 55 | Ditto all as per item no 44 above but MCCB 250 Amps, 36 KA, 4 Pole, 415V, complete all as specified and directed. |
| 56 | Ditto all as per item no 44 above but MCCB 400 Amps, 36 KA, 4 Pole, 415V, complete all as specified and directed. |
| 57 | S&F in repairs, Metal plug and socket, 2 pin and earth plug and socket including with 20 Amps, MCB, SPconcealed/ surface on wall as per site requirement including all cutting holes in or throughwalls, making good to disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering etcas applicable to the disturbed surfaces to match the existing complete all as specified and directed.Make - L&T / Legrand / ABB /Schenider |
| 58 | S&F in repairs, Metal plug and socket, 3 pin and earth plug and socket including with 32 Amps, MCB, TPconcealed/ surface on wall as per site requirement including all cutting holes in or throughwalls, making good to disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering etcas applicable to the disturbed surfaces to match the existing complete all as specified and directed.Make - L&T / Legrand / ABB /Schenider |
| 59 | S&F in replacement MCB SP 6-40 Amps, 10KA, \"C\" series complete all as specified and as directed. |
| 60 | S&F in replacement MCB SPN 20-40 Amps,10KA, 240V, \"C\" series complete all as specified and as directed. |
| 61 | S&F in replacementMCB TP 40-63 Amps, 10KA, 415 V, \"C\" series complete all as specified and as directed. |
| 62 | S&F in replacementMCB TPN 40-63 Amps, 10 KA, 415V, \"C\" series complete all as specified and as directed. |
| 63 | S&F in replacement of burnt out / old unserviceable fan motor assembly complete including with double bearing, copper winding with metal plate top & bottom side suitable for 1200mm sweep of any existing make and at any location of ceiling fans complete all as specified and as directed by Engr-in-Charge.(Make :-Havells / Usha or equivalent in existing make |
| 64 | S&F in repairs of fan Condenser of 2.5 mfd capacity, 230 Volts complete all as specified and as directed.Make :-Havells / Epcos/Tibcon /Siemens |
| 65 | Supply and fixing in replacement PVC fresh air exhaust fan 250mm sweep with lovers Make: Bajaj /Cromptan /Havells, complete all as directed. |
| 66 | Supply only Self adhesive PVC electrical Insulation tape 7 mtr long, ISI mark with superior quality complete all as specified and as directed. |
| 67 | Supply only bearing No.6200 to 6203 or any other No. matching to the existing size and suitable for ceiling fan / exhaust fan / wall mounted fan, etc complete all as directed by Engr-in-charge.Make:- SKF or equivalent make. |
| 68 | Supply only Conductor Terminal3 way Bakelite of existing size complete all as directed by Engr-in-charge. |
| 69 | Supply only brass gun metal bushing suitable of size 1200/1400mm sweep ceiling fan etc complete all as directed by Engr-in-charge. |
| 70 | Supply andFix in replacement of canopy suitable for ceiling fans (Set of two) complete all as specified and as directed Engr-in-charge. |
| 71 | S&F in replacement fan blade (set of 3) suitable for 1200 mm of existing Make, complete all as specified and as directed. |
| 72 | Supply andFix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc. suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed. |
| 73 | M&L for testing detecting the location of fault in LT / HT underground cable with the help of by providing cable fault locating machine at site complete all as directed by Engr-incharge.(Note:- (a). The fault locating machine will be arranged by the contractor at his own cost i.e the cost of bringing of fault locating machine at site shall be deemed to be included in unit quoted rates. (b). Necessary excavation and earthwork etc. shall be measured and paid separately under respective items of BOQ |
| 74 | S&F in replacementof heat shrinkable Straight through jointing kit, suitable for LT 1.1 KV XLPE cables 150 to 240 Sqmm, 3.5 core with and including all accessories required complete all as specified and as directed by Engr-In-Charge |
| 75 | S&F in replacementof heat shrinkable Straight through jointing kit, suitable for LT 1.1 KV XLPE cables 95 to 120 Sqmm, 3.5 core with and including all accessories required complete all as specified and as directed by Engr-In-Charge |
| 76 | S&F in replacementof heat shrinkable Straight through jointing kit, suitable for LT 1.1 KV XLPE cables 25 to 70 Sqmm, 3.5 core with and including all accessories required complete all as specified and as directed by Engr-In-Charge |
| 77 | S&F in replacementof heat shrinkable Straight through jointing kit, suitable for LT 1.1 KV XLPE cables 6 to 16 Sqmm, 3.5 core with and including all accessories required complete all as specified and as directed by Engr-In-Charge |
| 78 | M&L in replacement of outdoor end termination joint cable jointing kit outdoor heat shrink type suitable for 11 KV HT cable 95 sqmm 3 core including with jointing material including all accessories required etc complete all as specified and as directed |
| 79 | Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depthfor laying cables, foundation for pole etcand getting out in soft/loose soil complete all as specified and directed. |
| 80 | Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depthfor laying cables, foundation for pole etcand getting out in hard / dense soil complete all as specified and directed. |
| 81 | Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depthfor laying cables, foundation for pole etcand getting out in soft / dis-integrated rocks complete all as specified and directed. |
| 82 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 83 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. |
| 84 | Material and labour for Reinforced concrete pipes, class NP2 with one collar per length of pipe of dia 100mm, half round (02 Nos. i.e for one for top & one for bottom) complete all as specified and as directed. |
| 85 | M&L for Servicing / overhauling of split AC with chemical washing process of outdoor unit, cleaning the filter, indoor unit grill, oiling of motor includingreplacing of defective parts like, blower motor, condenser fan, condenser motor, relay, selector switch, thermostat, compressor, cooling coil, PCB, capacitor and making the appliances functional, complete all as directed by Engr-in-charge. Note:- (i). Every AC shall be serviced once in contract period. (ii). All spares parts required shall be measured and paid separately as “Supply only”. (iii). On call services shall includes attending to any complaint any time of the contract period on receipt of verbal / written complaint from user / JE E/M / Engr-in-Charge. (iv). In case of any complaint is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100.00 per such complaint per day will be recovered from the amount due to the contractor through RAR / Final Bill.(v). Servicing/overhauling of 01 No AC complete in all respect and make it functional shall be measured as one job. |
| 86 | Supply only starting capacitor of 40 to 60 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge |
| 87 | Supply only starting capacitor of 60 to 80 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge |
| 88 | Supply only starting capacitor of 80 to 100 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-chargecomplete all as specified and as directed. |
| 89 | Supply only starting capacitor of 100 to 120 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge |
| 90 | Supply only running capacitor of 10/15/25 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge |
| 91 | Supply only running capacitor of 36 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge |
| 92 | Supply only running capacitor of 45 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge |
| 93 | Supply only running capacitor of 55-60 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge |
| 94 | Supply only fan blade (As per sample) in replacement suitable for split type AC of any capacity, complete all as directed. |
| 95 | Supply only thermostat complete suitable for split AC, as per smple including taking down old unserviceable thermostate, complete all as directed. |
| 96 | Supply only air filter made out of nylon wire mesh moulded in plastic, same as per old existing filter\"s size and shape suitable for 1.5/2 TR capacity of split type AC, complete all as directed. |
| 97 | Supply only cooling coil assembly suitable for any Make & any model of split AC complete including taking down of old unserviceable cooling coil, complete all as directed. |
| 98 | Supply only condenser coil assembly suitable for any Make & any model of split AC complete including taking down of old unserviceable condenser coil assembly, complete all as directed. |
| 99 | Supply only wiring kit suitable for split AC including taking down of old unserviceable wiring kit, complete all as directed |
| 100 | Supply only single shaft blower motor of 1/6, 1/8, 1/5 HP capacity suitable for split type AC of capacity 1.5/2 TR of any size complete as directed by Engineer-in-Charge |
| 101 | Supply only swing motor suitable for split AC (as per sample) including taking down of old unserviceable swing motor, complete all as directed. |
| 102 | Supply only electronic circuit plate (PCB) including necessary repairs to electronic circuit of remote operation suitable for 1.5 / 2.0 ton split type AC for any type complete all as directed. |
| 103 | S&F in replacement of remote with stand suitable for 1.5 / 2 ton split type AC operation for any make complete all as directed. |
| 104 | S&F in replacement Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC, complete all as directed |
| 105 | S&F in repairs single pole contactor of existing model and size suitable for 1.5 TR split type AC as per sample, complete all as directed. |
| 106 | S&F in repairs 3 pole power contactor 25 Amp, 220V AC suitable for 2 TR split type AC, as per sample, complete all as directed. |
| 107 | Taking down unserviceable / damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 1.5 ton capacity of existing dismantled model or equivalent as approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line etc as directed and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed. |
| 108 | Taking down unserviceable / damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 2 ton capacity of existing dismantled model or equivalent as approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line etc as directed and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed. |
| 109 | Taking down unserviceable / damaged / rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 1.5 ton existing dismantled model or equivalent as approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after re-fixing compressor of existing unit and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed. |
| 110 | Taking down unserviceable / damaged / rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 2 ton existing dismantled model or equivalent as approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after re-fixing compressor of existing unit and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed. |
| 111 | S&F in replacement of copper tubing, confirming to relevant IS, 5/8\" and 3/8\" flare size, or nearest size, including 3 core 2.5sqmm copper cable including PVC drain pipe and insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed by Engineer in charge. |
| 112 | S&F in replacement of service valve of size 5/8\", 1/2\" or nearest size suitable for split type AC of any capacity complete all as directed. |
| 113 | S&F in replacement brass flare nut of size 5/8\", 1/2\" or nearest size suitable for split type AC of any capacity, complete all as directed. |
| 114 | M&L for taking out of old broken drain outlet pipe of any type attached to indoor unit of split type AC & S & F new drain outlet PVC pipe of 20mm dia from indoor unit to nearest suitable drain outlet suitable for split type AC of any capacity complete all as directed by Engineer-in-charge |
| 115 | S & F in replacement factory made angle iron stand suitable for outdoor unit of split type ACs of any capacity complete all as directed. |
| 116 | Labour for shifting of split AC 1.5/ 2 ton capacity one place to another places as required at site and disconnecting of copper tubing, PVC pipe connection and installation of the same on new location indoor / outdoor unit complete with and incluidng gas charging with suitable type of gas, tested on full load on summer season complete all as specified and as directed. Note :- Copper tubing, PVC pipe etc shall be measured and paid saparately under respective items of BOQ. |
| 117 | S&F starting relay with OLP kit suitable for any Make any model refrigerator including with testing and commissioning complete all as specified and as directed. |
| 118 | S&F in replacement of thermostat switch suitable for any model of refrigerator complete all as specified and as directed |
| 119 | S&F electric Lamp 15 watt, 230 volt AC, thread / pin type suitable for any Make & capacity of refrigerator complete all as specified and as directed |
| 120 | S&F in replacement of lamp holder suitable for any Make& capacity / model of refrigerator complete all as specified and as directed |
| 121 | S&F in replacement of door switch push type suitable for any Make & capacity or model of refrigerator complete all as specified and as directed |
| 122 | S&F in replacement of broken / damaged freezer door complete with casing and lock nut as per sample suitable for existing refrigerators of any capacity, complete all as directed. |
| 123 | S&F in replacement of vegetable tray complete suitable for existing model of refrigrators of any capacity, complete all as directed. |
| 124 | S&F door handle suitable for Refrigerators of any Make & model / any capacity, complete all as directed. |
| 125 | S&F PVC bottle guard suitable for 185 to 340 Ltr Refrigerators suitable for any Make & model / any capacity, complete all as directed. |
| 126 | S&F in replacement of chiller tray suitable for existing model of refrigerators of any make & capacity, complete all as directed. |
| 127 | S&F in replacement of metal shelf powder coated suitable for existing model of refrigerator of any make & capacity, complete all as directed. |
| 128 | S&F in replacement of cooling coil suitable for 185/198 Ltrs capacity refrigerator of existing model, complete all as directed by Engr-in-charge. |
| 129 | S&F in replacement of cooling coil suitable for 340 Ltrs capacity refrigerator of existing make / model, complete all as directed by Engr-in-charge. |
| 130 | S&F in replacement of condensor suitable for 185/198 Ltrs capacity refrigerator of existing model, complete all as directed by Engr-in-charge. |
| 131 | S&F in replacement of condensor suitable for 340 Ltrs capacity refrigerator of existing make / model, complete all as directed by Engr-in-charge. |
| 132 | S&F in replacement of PVC gasket magnetic type suitable for any Make & any model / any capacity of refrigerators complete, complete all as directed. |
| 133 | S&F plastic ice cube tray, complete all as directed. |
| 134 | S&F in replacement toughened glass partition / shelves suitable for any capacity or any Make & any model of refrigerator, complete all as directed. |
| 135 | S&F in replacement of timer switch suitable for any Make & any model /any capacity of refrigerator, complete all as directed |
| 136 | M&L for cleaning of water cooler’s tank by from inner side and washed with soda / Acid and de-scaling by brushing and stop leakage (if any) from water tank by soldering / welding and make water tank leak proof and complete all as specified and as directed |
| 137 | M&L for disconnecting the water cooler of any capacity from electric and water connections and cleaning the condenser unit & fins by using carbon tetra chloride cleaning agent, oiling / greasing of fan motor, checking of alignment of motor, cleaning of water storage tank and re-fixing back the same and testing for its smooth functioning complete all as directed by Eng-in-charge. |
| 138 | S&F in replacement 15 mm bore PVC connection 600 mm long with PTMT nut and PVC washer, complete all as specified and directed. |
| 139 | S&F in replacement 15 mm bore PVC connection 900 mm long with PTMT nut and PVC washer, complete all as specified and directed. |
| 140 | S&F in replacement 15 mm bore PVC connection 1200 mm long with PTMT nut and PVC washer, complete all as specified and directed. |
| 141 | S&F in replacement 15mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 142 gms), complete all as specified and directed. |
| 142 | S&F PVC pipe flexible type 32 mm dia suitable for waste water draining complete all as specified and as directed |
| 143 | S&F in replacement over load protector relay (OLP) suitable for water cooler of any capacity complete all as specified and as directed |
| 144 | S&F in replacement self closing push tap, 15mm bore, brass chromium plated, long body, inner threaded complete all as specified and as directed. |
| 145 | S&F in replacement of condenser fan motor, as per existing for water cooler 120/180 Ltrs capacity, single phase, 230 VAC complete all as directed. |
| 146 | S&F in replacement aluminium blade suitable for blower motor of water cooler of 120/180 Ltrs capacity, complete all as specified and as directed |
| 147 | S&F in replacement relay suitable for water cooler of any capacity and make complete all as specified and as directed |
| 148 | S&F in replacement thermostate suitable for water cooler of any type & capacity complete all as specified and as directed |
| 149 | S&F in replacement of blower motor 1/32 HP, 230 volt suitable for 120/180 ltrs capacity water cooler complete with base frame and rubber bush complete all as specified and as directed |
| 150 | S&F in replacement drip tray made of stainless steel suitable for 120/180 ltr capacity water cooler any Make complete all as specified and as directed |
| 151 | Supply & fix in replacement 15 Amps plug top and connection complete all as specified and as directed |
| 152 | S&F water tank gasket suitable for water cooler of 120/180Ltr capacity complete all as specified and as directed |
| 153 | S&F in replacement wiring kit complete suitable for water cooler complete all as specified and as directed |
| 154 | S&F in replacement cooling coil assembly suitable for any Make & model of water cooler including taking down old unserviceable, complete all as directed. |
| 155 | S&F in replacement condenser coil assembly suitable for any Make & any model of water cooler complete including taking down old unserviceable, complete all as directed. |
| 156 | S&F in replacement of corroded bottom portion suitable for water cooler of any make & capacity with MS angle iron of suitable size as per existing, including necessary welding / brazing with mild steel sheet of 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as directed by Engr-in-charge |
| 157 | M&L for servicing of deep freezer unit completely and ensure its smooth functioning and satisfactory performance by means of cleaning each part of the machine carefully, greasing / oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and air pressure through blower, complete all as directed by Engr-in-charge |
| 158 | S & F in replacement of condenser coil suitable for deep freezer of any make and capacity including taking down old unserviceable, complete all as directed. |
| 159 | S & F in replacement of evaporator of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed. |
| 160 | S & F in replacement of de-frost heater of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed. |
| 161 | S & F in replacement of de-frost timer of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed. |
| 162 | S & F in replacement of top spring loaded hinge of deep freezer of any make and capacity including taking down old unserviceable, complete all as directed. |
| 163 | M&L for servicing / repairing of desert cooler\"s fan by disconnecting from desert cooler with and including cleaning of water water tank by using wire brush and sand papering the surfaces, greasing & oiling of all moveable parts, stop water leakages (If any) from water tank by welding or by using M\"seal and make it leak proof and finally applying two coats of synthetic enameled paint on hole body (inner & outer side) of desert cooler, re-assembled the same & fixed it\"s in original position including replacement of unserviceable spares, complete all as specified and directed by Engr-in-charge.Note:- Spare parts will be measured and paid separately under respective item of BOQ as \"Supply only\". |
| 164 | Supply only desert cooler fan motor of copper binding of existing capacities & make complete all as specified and as directed |
| 165 | Supply only fan blade suitable for desert cooler\"s as per existing size complete all as directed |
| 166 | Supply only capacitor 4 mfd suitable for desert cooler complete all as specified and as directed |
| 167 | S&F in replacement of PVC water distributer junction 3 way / 4 way suitable for desert cooler of any size / capacity complete all as specified and as directed |
| 168 | S&F in replacement of PVC elbow suitable for desert cooler of any size / capacity complete all as specified and as directed |
| 169 | S&F in replacement of PVC flexible pipe, 15 mm dia, suitable for water distribution system to desert cooler of any size / capacity complete all as specified and as directed |
| 170 | S&F in replacement of front grill plastic type suitable for desert cooler with necessary nut, bolts, and washers etc, complete all as specified and as directed. |
| 171 | M&L for replacement of caster wheels (set of four) complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge. |
| 172 | M&L for removing pump motor set of desert cooler of any size and capacity. S&F new pump motor submersible type single phase AC , 230 Volts , 50 Hz of suitable capacity and size all as directed by Eng-in-charge. |
| 173 | M&L for replacement of switch assembly complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge. |
| 174 | S&F in replacement of wood wool padding of desert cooler of suitable size including with wire net, weight not less than 450 gms in each panel complete all as specified and as directed |
| 175 | S&F in replacement PVC body of desert cooler including with shutter, top & base tank up to 50 litres capacity including complete wiring with 2.50 Sqmm copper wire, Selector switch, capacitor, provision of clamps for exhaust fan motor, water lifting pump, PVC pipes & water distributor connectors etc complete all as directed by Engr-in-Charge |
| 176 | S&F in replacement of sealed compressor unit suitable for refrigerator of capacity 185/198 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge. |
| 177 | S&F in replacement of sealed compressor unit suitable for refrigerator of capacity 340 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge. |
| 178 | S&F in replacement of sealed compressor unit suitable for water cooler of capacity 120/180 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge. |
| 179 | S&F in replacement of sealed compressor unit suitable for deep freezer of capacity 320 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge. |
| 180 | S&F in replacement of sealed compressor unit suitable for split AC of capacity 1.5 TR of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge. |
| 181 | S&F in replacement of sealed compressor unit suitable for split AC of capacity 2 TR of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge. |
| 182 | M&L for gas charging in refrigerator of any capacity & make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge. |
| 183 | M&L for gas charging in water cooler of any capacity & make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge. |
| 184 | M&L for gas charging in deep freezer of any capacity & make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge. |
| 185 | M&L for gas charging in split AC of 1.5 2 TR capacity of any make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge. |
| 186 | M&L for gas charging in mortuary cabinet for 04 body of any make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge. |
| 187 | S&F in replacement of indoor discharge fan suitable for walk-in cooler of 5 TR capacity complete all as directed by Engr-in-charge. |
| 188 | S&F in replacement of indoor discharge fan suitable for walk-in cooler of 1 TR capacity complete all as directed by Engr-in-charge. |
| 189 | S&F in replacement of HP/LP cut off, KP-15 Make - Danfoss/Indfoss suitable for Walk-in-Cooler of any type complete all as directed by Engr-in-charge. |
| 190 | S&F in replacement drier filter of 5/8\", 3/8\", 1/2\" flare size or other nearest flare size, complete all as directed by Engr-in-charge.Make - Sporlon / Catchall or equivalent |
| 191 | S & F in replacement of Digital sub-zero thermostat suitable for the cold storage & programe the thermostat for auto cut-off including all wiring complete all as directed by Engr-in-charge. |
| 192 | Taking out of old unserviceable sealed compressor unit from the Walk in cooler of any make & capacity by means of cutting to suction & discharge pipe line, disconnecting from electric supply, foundation nut bolts, etc and keeping aside as directed and supply and fixing new sealed compressor unit of existing make and capacity, complete all as directed by Engr-in-charge. |
| 193 | M & L for vacuumising the complete system of walk-in cooler with double stage vacuum pump of 2kg/cm2 with and including charging with nitrogen gas up to 250-300 PSI the complete system and check for leak testing and maintaining the pressure for 24 hrs and rectifying the leakage if any in system and after that with and including charging the system with F-22 gas with required quantity, complete all as directed by Engr-in-charge. |
| 194 | S&F in replacement voltage stabilizer 5 KVA, copper winded, complete all as specified and as directed.Make:- APLAB / V Guard / Vintek Electronics (Volina) |
| 195 | S&F in replacement voltage stabilizer 2 KVA, copper winded, complete all as specified and as directed.Make:- APLAB / V Guard / Vintek Electronics (Volina) |
| 196 | S&F in replacement of burnt winding of padestal fans 400 mm sweep, working on 230 volts AC supply, and M&L for re-winding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete all as specified and directed by Engr-in-charge |
| 197 | Supply only bearing suitable for Padestal fan 400mm sweep complete all as specified and directed by Engr-in-charge |
| 198 | Supply only brass gun metal bushing suitable for Padestal fan 400mm sweep complete all as specified and directed by Engr-in-charge. |
| 199 | M&L for servicing and cleaning of mortuary Cabinet for capacity of 4 body with suitable chemical detergent and acid using pump, washing the same with water by using pump set and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable complete all as specified and directed. |
| 200 | Taking out of old unserviceable sealed compressor unit from the motuary Cabinet of any make & capacity by means of cutting to suction & discharge pipe line, disconnecting from electric supply, foundation nut bolts, etc and keeping aside as directed and S&F new sealed compressor unit of existing make and capacity, complete all as directed by Engr-in-Charge. |
| 201 | S & F in replacement of new 5 Amp pin top (ISI marked) of approved make complete all as specified and as directed. |
| 202 | S & F in replacement of new 15 Amp pin top (ISI marked) of approved make complete all as specified and as directed. |
| 203 | S&F lamp holder insulated body with back plate for batten fittings with and incluidng 9 watts LED bulb 5 star rated, complete all as specified and directed. |
| 204 | Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes of size 150 Sqmm 3.5 core complete all as specified and as directed. |
| 205 | Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes of size 50 Sqmm 3.5 core complete all as specified and as directed. |
| 206 | Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes of size 35 Sqmm 3.5 core complete all as specified and as directed. |
| 207 | Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes of size 25 Sqmm 3.5 core complete all as specified and as directed. |
| 208 | Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes of size 16 Sqmm 4 core complete all as specified and as directed. |
| 209 | Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes of size 10 Sqmm 2 core complete all as specified and as directed. |
| 210 | Supply, laying, testing and commissioning of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes of size 6 Sqmm 2 core complete all as specified and as directed. |
| 211 | S&F in replacement of 3 core, 4 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge |
| 212 | S&F in replacement of 3 core, 2.5 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge |
| 213 | S&F in replacement of 3 core, 1.5 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge |
| 214 | S&F in replacement of 3 core, 6 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge |
| 215 | M & L For fixing of earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe with 6 sqmm GI Wire complete all as specified and directed |
| 216 | S&F in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed. |
| 217 | M&L for earthing complete with galvanised steel earth plate electrode including necessaryexcavation and earth work in any type of soil with galvanized steelearth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly inground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground levelconnected to with and including earth lead of 6 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concretepit shall be PCC 1:3:6 type C-1,40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI \"light grade\" tubing with all fittings from earth plate up to panel shall beprovided & charcoal / saltfunnel & other fittings etc. complete all as specified and as directed.Note :- (i) Unit rates includes the cost of 7.50 m GI pipe for protection of 6mm dia GI earth wire for each earthing. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail