}

Tender For Electrical Safety Related External Electrification Work At Lala Lajpat Rai And Affiliated Govt. Medical College, Kanpur, 1 11 Kv Double Pole Structure 2 Supply, Erection, Testing And Commissioning Of 2 Pole Structure For Providing 1 No. 11, Kanpur Nagar-Uttar Pradesh

Boards / Undertakings / PSU has published Tender For Electrical Safety Related External Electrification Work At Lala Lajpat Rai And Affiliated Govt. Medical College, Kanpur, 1 11 Kv Double Pole Structure 2 Supply, Erection, Testing And Commissioning Of 2 Pole Structure For Providing 1 No. 11. Submission Date for this Tender is 07-08-2024. Electrification Work Tenders in Kanpur Nagar Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44224601
Corrigendum : Tender For Electrical Safety Related External Electrification Work At Lala Lajpat Rai And Affiliated Govt. Medical College, Kanpur, 1 11 Kv Double Pole Structure 2 Supply, Erection, Testing And Commissioning Of 2 Pole Structure For Providing 1 No. 11
Open Tender
Indian
Uttar Pradesh
Kanpur Nagar
07-08-2024

Tender Details

Tender For Electrical Safety Related External Electrification Work At Lala Lajpat Rai And Affiliated Govt. Medical College, Kanpur, 1 11 KV DOUBLE POLE STRUCTURE 2 Supply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,200A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following. 3 a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc. 4 b. 1 Set of cross arms, branching, clamps and painting complete with GI nut, bolts & washers as required (for GO & DO), LA connection. 5 c .1 set 11KV Insulator complete with spindles & hardware complete as required. 6 d .1 No. 11KV 400A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement. 7 e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses, and mounting arrangement. 8 f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases. 9 g. 1 No. 150 mm dia GI pipe class B (for XLPE cable protection) as required. 10 h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA) 11 i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices. 12 11 KV DOUBLE POLE STRUCTURE 13 a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc. 14 b. 1 Set of cross arms, branching, clamps and painting complete with GI nut, bolts & washers as required (for GO & DO), LA connection. 15 c .3 set 11KV Insulator complete with spindles & hardware complete as required. 16 e. 1 No. 150 mm dia GI pipe class B (for XLPE cable protection) as required. 17 f. 2 Set 50mm dia 3m long GI pipe earting with 25 x 3 mm GI earth strip complete as required 18 g. 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices. 19 Supply, installing, testing and commissioning of INDOOR TYPE 11KV, HT VCB Panel Board having Vacuum Circuit Breakers with Motorized cum manual spring charging mechanism rated for 11KV, 800Amp, 18.4kA/3 Sec, Floor rolling type, Horizontal Isolation & Horizontal Draw-out type design confirming to IS 13118, IEC 62271-100, Internal Arc tested as per IEC 62271 - 200, Mechanical Endurance of M2 class ensuring 10000 operating sequences and E2 class Electrical Endurance. The VCB Panel Board comprising Aluminum Bus-Bar of 8OOAmp, Earthing Truck of suitable making capacity along with safety interlocking for complete board and control voltage of 24V DCwith SCADA compatibility .The VCB Panel board supplied with mandatory spares such as 4 Nos. Trip Coil, 4 Nos. Closing Coil, 3 Nos. Spring Charging Motors, 2 Nos. Space Heaters, 2 Nos. Rack-in & Rack-out handle. The Board shall consist following panels : 20 11 KV INCOMER VCB PANEL : 21 11 KV, 800Amp, 18.4KA/3 Se, Floor rolling type, Horizontal Isolation & Horizontal Draw-out type as per IS 13118, IEC 62271-100. Vacuum Circuit breaker should have 3 Nos. encapsulated Vacuum Bottels of same manufacturer as of Circuit Breaker. Motorized spring charging mechanism (230V AC) with integral spring charging handle for manual spring charging associated shunt type trip & close coils (24 V DC) 22 Current Transformer 23 1 set of 3 Nos. Single Phase, 11 KV, 800/400/1+1+PS Class, core 1 : Class 5P10, 15VA, Core 2 :Class 0.5, 15VA and Core 3: PS Class for Transformer Differential Protection (PS Class: VK > 200V, Imag < 30mA @ Vk/2) 24 Potential Transformer 25 1 set .of ,3 Nos. Draw-out Type Feeder Connected PTs having ratio 11KV/rt3/110V/rt3, Class 0.5/3P, 100VA along with associated HRC Fuses for Primary side protection. 26 Accessories : TNC Switeh, Panel Space Heater, Push Button Trip Circuit Healthy- Check, Panel illumination lamp with switch, 3 Pin Plug with Socket of 15Amp., Local &. Remote Switch, Emergency Trip Button, AC &. DC control illumination lamp with switch 3 Pin plug with socket of 15 Amp., Local & remote Switch, Emergency Trip Button, AC & DC Control circuit through MCB, Auxiliary Contacts (6 NO + 6 NC), Anti Pumping Device. 27 Indications: LED Type Indications for R - Y - B Phase, Breaker On/OFF, Spring Charged, Trip Circuit Healthy, Breaker Trip, Breaker Test / Service position, AC & DC Healthy. 28 Metering Instruments : 1 No. Tri-vector Meter (Ace. CI. 0.5) of L&T/Secure make, 1 No. Digital Voltmeter (Acc. CI. 0.5) of Rishabh, AE &. Elmeasure make, 1 No. Digital Ammeter (Acc. CI. 0.5) of Rishabh, AE & Elmeasure make. 29 Protection & Auxiliary Relay : 30 1 No. Numerical 3 Over Current + 1 Earth Fault (50/51/50N/51N) Relay providing over Current (Low Set: 5% - 200% / High Set: 50% - 1600% in step of 1%), Earth Fault (Low Set: 5% - 200% / High Set: 50% - 1600% in steps of 1%). Relay wil/be communicable on IEC 603 Protocol. 31 1 No. Numerical Under Voltage + Over Voltage (27/59) Relay providing Over Voltage Protection (105% - 170% in steps of 1%), Under Voltage Protection (15% :. 90% in steps of 1 %), No Voltage Protection (3% ~ 20% in steps of 1V). Relay will be communicable on IEC 603 Protocol. 32 1 No. Trip Circuit Supervision Relay 33 1 No. High Speed Master Trip Relay 34 Additional Accessories and Features : 35 Electrical Interlocking between Incomers & Bus-Coupler to prevent mixing of suppliers. 36 Standard features should include provision for connecting atleast one run of outgoing cables, Test Terminal Block for protection circuit. Panel fabrication shall preferably be made from sheet steel, safety shutters, continuous rated close & Trip coils. Type tested for Internal Arc for 18.4KA Vacuum Bottels, VCB &. Panel should be of same make. Control Circuit shall operate on 24V,DC except Spring Charging Motor &. Space eater which. shall operate on 24V DC except Spring Charging Motor & Space Heater which shall operate on 230V AC. 37 11 KV OUT GOING VCB PANEL : 38 Same description as INCOMER PANEL above except following changes 39 Potential Transformer, Voltmeter, R - Y - B Phase Indication, Under Voltage +relay are not required in Outgoing Panels 40 Current Transformer : 41 1 Set 3 Nos. Single Phase, 11 KV, 200/100/1+1, Core 1 : Class 5P1015 VA, Core-2 : Class 0.5., 15VA 42 11 KV BUS-COUPLER VCB PANEL : 43 Same description as INCOMER PANEL above except following changes: 44 Current Transformer, Potential Transformer, Tri-vector Meter, Ammeter, Voltmeter, R - Y - B Phase Indication, Protection & Auxiliary Relays 11KV 630 VCB Panel. 45 Supply of 11KV grade 3core Brand Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments. 46 240sq.mm 3 core 47 300sq.mm 3 core 48 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 49 Above 120 sq. mm and upto 400 sq. mm 50 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. 51 Above 120 sq. mm and upto 400 sq. mm 52 Laying of one number XLPE power cable of 11/33 kV grade of following size direct in ground by mechanical mean alongwith laying of pipe as required. 53 Above 120 sq. mm and upto 400 sq. mm 54 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required . 55 240sq.mm 3 core 56 300sq.mm 3 core 57 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 58 240sq.mm 3 core/300sq.mm 3 core 59 300sq.mm 3 core 60 Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 61 240sq.mm 3 core/300sq.mm 3 core 62 300sq.mm 3 core 63 Supply of Heavy density poly ethylene pipes ISI marked anti radiant grade OD-160mm dia PN-6 grade having minimum wall thickness 9.5mm as per IS Code 4984 with socket coupler with trenchless excavation system. Complete in all respects. 64 Unitised Sub Station (11KV / 415 V) 800 KVA With 1 I/C & 2 O/G (With Natural cooling) 65 Supply & InstallationOutdoor type package substation with facility for internal lighting, earthing, padlocks etc. Connection between RMU & transformer will be by 1 no. 3Cx95 sq.mm. XLPE cable/Cu. Busbarand connections from transformer to LT ACB will be by busbar connections. 66 Unitised Sub Station will have the following equipment 67 H.T SWITCHGEAR 68 Three way, 11KV 630Amp. 25KA for 1 sec. SF6 insulated Non-Extensible compact switchgear consisting of two nos. of fixed load break switch and one no. fixed vacuum circuit breaker in SF6 insulated stainless steel enclosure with self powered series trip microprocessor base numerical over current & earth fault relay (IDMTL+inst.) for protection. 69 RMU NON Extensible (2 isolators, 1 VCB with CU Busbar 70 Function type- 3 position disconnector and earthing switch equipped with separate drive unit. 71 1. Operation of LBS manual 72 2. Cable switch rating 11KV,630A, 25KA for 1 sec 73 3. Cable bushing rating 630A. 74 4. Cable cover- As per our standard. 75 5. Fixed type capacitive voltage indication provided. 76 6. ON/OFF/Earth indication on the front mimic of the panel. 77 7. Bottom cable termination-suitable upto 1 No. 3C X 300sq.mm 78 8. Cable entry bottom, front. 79 9. Fault passage indicator (FPI)-E/F 80 FUNCTION Type- 3 position disconnector and earth switch equipped with seperate drive unit. Breaker equipped with over current time release for transformer protection. 81 1. VCB 11KV, 630A, 25kA/1sec. 82 2. Operation of breaker-Manual 83 3. Self powered electronic numerical protection relay providing over current and earth fault protection. 84 4. Tape wound protection current transformer 85 5. Capacitive voltage indication fixed type. 86 6. ON, OFF, EARTH indication on the frount mimic of the panel 87 7. Cable box for termination of cable. 88 8. Cable cover stand. 89 9. Emergency trip push button. 90 10. Shunt trip coil. 91 11. Operation counter. 92 12. Ammeter. 93 RMU accessories- 94 Manual Operating handle-1nos. 95 Standard manometer for SF6 GAS pressure indication. 96 Right angled cable boots suitable for 1 RMU X 3C X 300sq.mm 97 Transformer (Manufactured as per IS 1180 Level-II) 98 Type- ONAN, Hermatically sealed corrugated tack. 99 1. Ratio- 11KV/433V 100 2. Capacity 800KVA 101 3. Vector group DYn11 102 4. Off load tappings +5% to -10% in steps of 2.5% 103 5. Winding- Double wound copper 104 6. Class of insulation-A 105 7. Ambient temp. 40 degree C 106 8. Temp. rise in oil over ambient- 40 deg. C 107 9. Temp. rise in winding over ambient- 45 deg. C 108 Transformer Accessories 109 Oil Temperature indicator 110 LT Busbar- Main bus bar are aluminium however copper flexible arer provided between Transformer and LT incommer connection alongwith main busbar 111 1. Voltage rating 433V 112 2. Current rating- 1500 Amp. 113 L.T Panel 114 Incoming # 1 115 1600Amp. 50KA, 4P EDO ACB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexture 116 ON, OFF TRIP lamp. 117 R/Y/B indicating lamp. 118 Multifunction meter 119 CT-1600/5A, CL1.0, 10VA 120 Incoming # 2 For Inbuilt 380KVAR APFC Panel 121 800Amp. 50KA, TP ACB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexture for inbuilt 380KVAR APFC Panel 122 ON, OFF TRIP lamp. 123 R/Y/B indicating lamp. 124 Multifunction meter 125 CT-800/5A, CL1.0, 10VA 126 ENCLOSURE for PSS 127 Rated temperature enclosure class should be K10 128 Outdoor type 2mm thick galvenised enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for transformer compartment. The enclosure exterior shall be powder coated with PP based paint. HT & LT compartment will be provided with the door and pad locking arrengement. Transformer compartment will be provided with cover. The compartment illumination lamp with door operated switch shall be provided for lifting arrengement shall be provided with PSS. Base frame of PSS shall be 4mm thick 129 Earthing- Internal earthing connection by using 50X6 Aluminium strips. 130 Unitised Sub Station (11KV / 415 V) 800 KVA With 1 I/C & 3 O/G (With Natural cooling) 131 Outdoor type package substation with facility for internal lighting, earthing, padlocks etc. Connection between RMU & transformer will be by 1 no. 3Cx95 sq.mm. XLPE cable/Busbarand connections from transformer to LT ACB will be by busbar connections. 132 Unitised Sub Station will have the following equipment 133 H.T SWITCHGEAR 134 Three way, 11KV 630Amp. 25KA for 1 sec. SF6 insulated Non-Extensible compact switchgear consisting of 3 nos. of fixed load break switch and one no. fixed vacuum circuit breaker in SF6 insulated stainless steel enclosure with self powered series trip microprocessor base numerical over current & earth fault relay (IDMTL+inst.) for protection. 135 RMU NON Extensible (3 isolators, 1 VCB with CU Busbar 136 Function type- 3 position disconnector and earthing switch equipped with separate drive unit. 137 1. Operation of LBS manual 138 2. Cable switch rating 11KV,630A, 25KA for 1 sec 139 3. Cable bushing rating 630A. 140 4. Cable cover- As per our standard. 141 5. Fixed type capacitive voltage indication provided. 142 6. ON/OFF/Earth indication on the front mimic of the panel. 143 7. Bottom cable termination-suitable upto 1 No. 3C X 300sq.mm 144 8. Cable entry bottom, front. 145 9. Fault passage indicator (FPI)-E/F 146 FUNCTION Type- 3 position disconnector and earth switch equipped with seperate drive unit. Breaker equipped with over current time release for transformer protection. 147 1. VCB 11KV, 630A, 25kA/1sec. 148 2. Operation of breaker-Manual 149 3. Self powered electronic numerical protection relay providing over current and earth fault protection. 150 4. Tape wound protection current transformer 151 5. Capacitive voltage indication fixed type. 152 6. ON, OFF, EARTH indication on the frount mimic of the panel 153 7. Cable box for termination of cable. 154 8. Cable cover stand. 155 9. Emergency trip push button. 156 10. Shunt trip coil. 157 11. Operation counter. 158 12. Ammeter. 159 RMU accessories- 160 Manual Operating handle-1nos. 161 Standard manometer for SF6 GAS pressure indication. 162 Right angled cable boots suitable for 1 RMU X 3C X 300sq.mm 163 Transformer (Manufactured as per IS 1180 Level-II) 164 Type- ONAN, Hermatically sealed corrugated tack. 165 1. Ratio- 11KV/433V 166 2. Capacity 800KVA 167 3. Vector group DYn11 168 4. Off load tappings +5% to -10% in steps of 2.5% 169 5. Winding- Double wound copper 170 6. Class of insulation-A 171 7. Ambient temp. 40 degree C 172 8. Temp. rise in oil over ambient- 40 deg. C 173 9. Temp. rise in winding over ambient- 45 deg. C 174 Transformer Accessories 175 Oil Temperature indicator 176 LT Busbar- Main bus bar are aluminium however copper flexible arer provided between Transformer and LT incommer connection alongwith main busbar 177 1. Voltage rating 433V 178 2. Current rating- 1500 Amp. 179 L.T Panel 180 Incoming # 1 181 1600Amp. 50KA, 4P EDO ACB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexure 182 ON, OFF TRIP lamp. 183 R/Y/B indicating lamp. 184 Multifunction meter 185 CT-1600/5A, CL1.0, 10VA 186 Incoming # 2 For Inbuilt 380KVAR APFC Panel 187 800Amp. 50KA, TP ACB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexture for inbuilt 380KVAR APFC Panel 188 ON, OFF TRIP lamp. 189 R/Y/B indicating lamp. 190 Multifunction meter 191 CT-800/5A, CL1.0, 10VA 192 ENCLOSURE for PSS 193 Rated temperature enclosure class should be K10 194 Outdoor type 2mm thick galvenised enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for transformer compartment. The enclosure exterior shall be powder coated with PP based paint. HT & LT compartment will be provided with the door and pad locking arrengement. Transformer compartment will be provided with cover. The compartment illumination lamp with door operated switch shall be provided for lifting arrengement shall be provided with PSS. Base frame of PSS shall be 4mm thick 195 Earthing- Internal earthing connection by using 50X6 Aluminium strips. 196 Unitised Sub Station (11KV / 415 V) 400 KVA With 1 I/C & 2 O/G (With Natural cooling) 197 Outdoor type package substation with facility for internal lighting, earthing, padlocks etc. Connection between RMU & transformer will be by 1 no. 3Cx95 sq.mm. XLPE cable/Busbarand connections from transformer to LT ACB will be by busbar connections. 198 Unitised Sub Station will have the following equipment 199 H.T SWITCHGEAR 200 Three way, 11KV 630Amp. 25KA for 1 sec. SF6 insulated Non-Extensible compact switchgear consisting of two nos. of fixed load break switch and one no. fixed vacuum circuit breaker in SF6 insulated stainless steel enclosure with self powered series trip microprocessor base numerical over current & earth fault relay (IDMTL+inst.) for protection. 201 RMU NON Extensible (2 isolators, 1 VCB with Cu. Busbar 202 Function type- 3 position disconnector and earthing switch equipped with separate drive unit. 203 1. Operation of LBS manual 204 2. Cable switch rating 11KV,630A, 25kA/1sec. 205 3. Cable bushing rating 630A. 206 4. Cable cover- As per our standard. 207 5. Fixed type capacitive voltage indication provided. 208 6. ON/OFF/Earth indication on the front mimic of the panel. 209 7. Bottom cable termination-suitable upto 1 no. 3C X 300sq.mm 210 8. Cable entry bottom, front. 211 9. Fault passage indicator (FPI)-E/F 212 FUNCTION Type- 3 position disconnector and earth switch equipped with seperate drive unit. T2 equipped with over current time release for transformer protection. 213 1. VCB 11KV, 630A, 25kA/1sec. 214 2. Operation of breaker-Manual 215 3. Self powered electronic numerical protection relay providing over current and earth fault protection. 216 4. Tape wound protection current transformer 217 5. Capacitive voltage indication fixed type. 218 6. ON, OFF, EARTH indication on the frount mimic of the panel 219 7. Cable box for termination of cable. 220 8. Cable cover stand. 221 9. Emergency trip push button. 222 10. Shunt trip coil. 223 11. Operation counter. 224 12. Ammeter. 225 RMU accessories- 226 Manual Operating handle-1nos. 227 Standard manometer for SF6 GAS pressure indication. 228 Right angled cable boots suitable for 1 RMU X 3C X 300sq.mm 229 Transformer (Manufactured as per IS 1180 Level-II) 230 Type- ONAN, Hermatically sealed corrugated tack. 231 1. Ratio- 11KV/433V 232 2. Capacity 400KVA 233 3. Vector group DYn11 234 4. off load tappings +5% to -10% in steps of 2.5% 235 5. Winding- Double wound copper 236 6. Class of insulation-A 237 7. Ambient temp. 40 degree C 238 8. Temp. rise in oil over ambient- 40 deg. C 239 9. Temp. rise in winding over ambient- 45 deg. C 240 Transformer Accessories 241 Oil Temperature indicator 242 LT Busbar- Main bus bar are aluminium however copper flexible arer provided between Transformer and LT incommer connection alongwith main busbar 243 1. Voltage rating 433V 244 2. Current rating- 1000 Amp. 245 L.T Panel 246 Incoming 247 800Amp. 50KA, 4P EDO ACB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexture 248 ON, OFF TRIP lamp. 249 R/Y/B indicating lamp. 250 Multifunction meter 251 CT-1000/5A, CL1.0, 10VA 252 Incoming # 2 For Inbuilt 200KVAR APFC Panel 253 400Amp. 50KA, TP MCCB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexture for inbuilt 380KVAR APFC Panel 254 ON, OFF TRIP lamp. 255 R/Y/B indicating lamp. 256 Multifunction meter 257 CT-400/5A, CL1.0, 10VA 258 Earthing- Internal earthing connection by using 50X6 Aluminium strips. 259 Unitised Sub Station (11KV / 415 V) 250 KVA With 1 I/C & 3 O/G (With Natural cooling) 260 Outdoor type package substation with facility for internal lighting, earthing, padlocks etc. Connection between RMU & transformer will be by 1 no. 3Cx95 sq.mm. XLPE cable/Busbarand connections from transformer to LT ACB will be by busbar connections. 261 Unitised Sub Station will have the following equipment 262 H.T SWITCHGEAR 263 Three way, 11KV 630Amp. 25KA for 1sec. SF6 insulated Non-Extensible compact switchgear consisting of two nos. of fixed load break switch and one no. fixed vacuum circuit breaker in SF6 insulated stainless steel enclosure with self powered series trip microprocessor base numerical over current & earth fault relay (IDMTL+inst.) for protection. 264 RMU NON Extensible (3 isolators, 1 VCB with AL Busbar 265 Function type- 3 position disconnector and earthing switch equipped with separate drive unit. 266 1. Operation of LBS manual 267 2. Cable switch rating 11KV,630A, 25kA/1sec. 268 3. Cable bushing rating 630A. 269 4. Cable cover- As per our standard. 270 5. Fixed type capacitive voltage indication provided. 271 6. ON/OFF/Earth indication on the front mimic of the panel. 272 7. Bottom cable termination-suitable upto 1 no. 3C X 300sq.mm 273 8. Cable entry bottom, front. 274 9. Fault passage indicator (FPI)-E/F 275 FUNCTION Type- 3 position disconnector and earth switch equipped with seperate drive unit. T2 equipped with over current time release for transformer protection. 276 1. VCB 11KV, 630A, 25kA/1sec. 277 2. Operation of breaker-Manual 278 3. Self powered electronic numerical protection relay providing over current and earth fault protection. 279 4. Tape wound protection current transformer 280 5. Capacitive voltage indication fixed type. 281 6. ON, OFF, EARTH indication on the frount mimic of the panel 282 7. Cable box for termination of cable. 283 8. Cable cover stand. 284 9. Emergency trip push button. 285 10. Shunt trip coil. 286 11. Operation counter. 287 12. Ammeter. 288 RMU accessories- 289 Manual Operating handle-1nos. 290 Standard manometer for SF6 GAS pressure indication. 291 Right angled cable boots suitable for 1 RMU X 3C X 300sq.mm 292 Transformer (Manufactured as per IS 1180 Level-II) 293 Type- ONAN, Hermatically sealed corrugated tack. 294 1. Ratio- 11KV/433V 295 2. Capacity 250KVA 296 3. Vector group DYn11 297 4. off load tappings +5% to -10% in steps of 2.5% 298 5. Winding- Double wound copper 299 6. Class of insulation-A 300 7. Ambient temp. 40 degree C 301 8. Temp. rise in oil over ambient- 40 deg. C 302 9. Temp. rise in winding over ambient- 45 deg. C 303 Transformer Accessories 304 Oil Temperature indicator 305 LT Busbar- Main bus bar are aluminium however copper flexible arer provided between Transformer and LT incommer connection alongwith main busbar 306 1. Voltage rating 433V 307 2. Current rating- 500 Amp. 308 L.T Panel 309 Incoming 310 500Amp. 50KA, 4P MCCB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexture 311 ON, OFF TRIP lamp. 312 R/Y/B indicating lamp. 313 Multifunction meter 314 CT-630/5A, CL1.0, 10VA 315 Incoming # 2 For Inbuilt 125KVAR APFC Panel 316 250Amp. 50KA, TP MCCB O/L, S/C, E/F protection LSIG, LCD Display having specs as per attached annexture for inbuilt 380KVAR APFC Panel 317 ON, OFF TRIP lamp. 318 R/Y/B indicating lamp. 319 Multifunction meter 320 CT-250/5A, CL1.0, 10VA 321 ENCLOSURE for PSS 322 Rated temperature enclosure class should be K10 323 Outdoor type 2mm thick galvenised enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for transformer compartment. The enclosure exterior shall be powder coated with PP based paint. HT & LT compartment will be provided with the door and pad locking arrengement. Transformer compartment will be provided with cover. The compartment illumination lamp with door operated switch shall be provided for lifting arrengement shall be provided with PSS. Base frame of PSS shall be 4mm thick. 324 Earthing- Internal earthing connection by using 50X6 Aluminium strips. 325 Construction of fencing & shed work 326 Supply & Construction of fencing & shed work arround the CSS & Panel including excavation refilling, painting etc. as required as per details given below:- 327 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 328 Ordinary rock 329 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 330 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 331 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 332 Cement mortar 1:6 (1 cement : 6 coarse sand) 333 Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 334 CEMENT PLASTER (IN FINE SAND) 335 12 mm cement plaster of mix : 336 1:6 (1 cement: 6 fine sand) 337 R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-incharge (cost of earth works in excavation, concrete works in foundation to be paid separately). 338 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 339 Made of G.I. wire of dia 4 mm 340 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 341 1.00 mm thick with zinc coating not less than 275 gm/m² 342 SUB STATION SAFETY EQUIPMENT : 343 Supplying and fixing 1800 mm x 900 mm wide checkered rubber matting conforming to IS5424-1969 complete as required. 344 Suitable for 11KV 345 Supplying & fixing standard shock treatment charts in English & Hindi duly framed and covered with glass. 346 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 347 Supplyand erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets complete in all respects, including fixing on walls as per the direction of engineer-in-charge. (CO2 gastype 6.5 kg. Capacity) 348 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 349 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 350 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 351 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 352 HOSPITAL BUILDING MAIN L.T PANEL 353 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 354 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall haveAMF facilityto achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display & should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec) 355 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec).MCCB, with microprocessor release with protection functionLCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (50 kA Ics) 356 INCOMING 357 4 Nos. 800 Amp FP EDO ACB 50KA , 358 BUSCOUPLER 359 1 Nos. 800Amp ACB 50KA , 360 AUTO OPERATION OF INCOMER / BUSCOUPLERACBs. 361 Load Management through PLC 362 Contactor for Load Management System 363 Auto changeover. 364 Buscoupler switching. 365 Electrial & Mechnical Interlocking. 366 BUSBARS 367 2 Nos. 1000 Amp TPN busbars of aluminium alloy . 368 OUTGOING 369 6Nos. 200 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 370 3Nos. 500 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 371 1Nos. 400 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 372 2Nos. 315 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 373 2 Nos. 250 Amp FP MCCB50 kA, with On, Off Indication lamp and A/V/KW meter 374 2 Nos. 160 Amp FP MCCB50 kA, with On, Off Indication lamp and A/V/KW meter 375 1 Nos. 125 Amp FP MCCB50 kA, with On, Off Indication lamp and A/V/KW meter 376 4 Nos. 100 Amp FP MCCB50 kA, with On, Off Indication lamp and A/V/KW meter 377 INSTRUMENTS 378 4 sets of multifunction meter with parameter current, voltage, KWH, KVAH, Power factor on incoming from transformers. Class Accuracy 0.5 with RS485 Port. 379 4 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 380 4 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 381 4 Sets auto trip indicating lamp . 382 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 383 Short Circuit Breaking capacity should not less than 50KA. 384 RELAYS 385 MEDICINE WARD & BURN WARD SIDE L.T PANEL 386 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 387 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall haveAMF facilityto achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display & should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec) 388 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec). MCCB, with microprocessor release with protection functionLCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (50 kA Ics) 389 INCOMING 390 1 Nos. 315 Amp FP MCCB 25 kA, 391 BUSBARS 392 1 Nos. 400 Amp TPN busbars of aluminium alloy . 393 OUTGOING 394 1 Nos. 160 Amp FP MCCB 25 kA, with On, Off Indication lamp and A/V/KW meter 395 5 Nos. 125 Amp FP MCCB 25 kA, with On, Off Indication lamp and A/V/KW meter 396 INSTRUMENTS 397 1 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers. With RS 485 398 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 399 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 400 1 Sets auto trip indicating lamp . 401 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 402 Short Circuit Breaking capacity should not less than 25KA. 403 RELAYS 404 ICU & EMERGENCY BLOCK MAIN L.T PANEL 405 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 406 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall haveAMF facilityto achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display & should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec) 407 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec).MCCB, with microprocessor release with protection functionLCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (50 kA Ics) 408 INCOMING 409 4 Nos. 800 Amp FP EDO ACB 50KA , 410 BUSCOUPLER 411 1 Nos. 800Amp ACB 50KA , 412 AUTO OPERATION OF INCOMER / BUSCOUPLERACBs. 413 Load Management through PLC 414 Contactor for Load Management System 415 Auto changeover. 416 Buscoupler switching. 417 Electrial & Mechnical Interlocking. 418 BUSBARS 419 2 Nos. 1000 Amp TPN busbars of aluminium alloy . 420 OUTGOING 421 2Nos. 800 Amp FP EDO ACB 50 kA,, with On, Off Indication lamp and A/V/KW meter 422 2Nos. 500 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 423 2Nos. 400 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 424 2Nos. 250 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 425 2Nos. 200 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 426 2Nos. 63 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 427 INSTRUMENTS 428 4 sets of multifunction meter with parameter current, voltage, KWH, KVAH, Power factor on incoming from transformers. Class Accuracy 0.5 with RS485 Port. 429 4 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 430 4 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 431 4 Sets auto trip indicating lamp . 432 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 433 Short Circuit Breaking capacity should not less than 50KA. 434 RELAYS 435 OPD BLOCK MAIN L.T PANEL 436 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be OUTDOOR, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 437 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall haveAMF facilityto achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display & should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec) 438 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=50 kA (1 sec).MCCB, with microprocessor release with protection functionLCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (50 kA Ics) 439 INCOMING 440 1 Nos. 1600 Amp FP EDO ACB 50KA , 441 2 Nos. 800 Amp FP EDO ACB 50KA , 442 AUTO OPERATION OF INCOMER / BUSCOUPLERACBs. 443 Load Management through PLC 444 Contactor for Load Management System 445 Auto changeover. 446 Buscoupler switching. 447 Electrial & Mechnical Interlocking. 448 BUSBARS 449 1 Nos. 2000 Amp TPN busbars of aluminium alloy . 450 OUTGOING 451 1Nos. 1000 Amp FP EDO ACB 50 kA,, with On, Off Indication lamp and A/V/KW meter 452 1Nos. 800 Amp FP EDO ACB 50 kA,, with On, Off Indication lamp and A/V/KW meter 453 4Nos. 500 Amp FP MCCB 50 kA,, with On, Off Indication lamp and A/V/KW meter 454 INSTRUMENTS 455 3 sets of multifunction meter with parameter current, voltage, KWH, KVAH,Power factor on incoming from transformers. Class Accuracy 0.5 with RS485 Port. 456 3 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 457 3 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 458 3 Sets auto trip indicating lamp . 459 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 460 Short Circuit Breaking capacity should not less than 50KA. 461 RELAYS 462 NURSES HOSTEL & RESIDENCES OUTDOOR TYPE PANEL 463 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be OUTDOOR, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 464 INCOMING 465 1 Nos. 500 Amp FP MCCB 25 KA, 466 BUSBARS 467 1 Nos. 630 Amp TPN busbars of aluminium alloy . 468 OUTGOING 469 1 Nos. 200 Amp FP MCCB 25 KA, with On, Off Indication lamp and A/V/KW meter 470 1 Nos. 125 Amp FP MCCB25 KA, with On, Off Indication lamp and A/V/KW meter 471 3 Nos. 100 Amp FP MCCB25 KA, with On, Off Indication lamp and A/V/KW meter 472 2 Nos. 63 Amp FP MCCB25 KA, with On, Off Indication lamp and A/V/KW meter 473 INSTRUMENTS 474 1 sets of multifunction meter with parameter current, voltage, KWH, KVAH,Power factor on incoming from transformers. Class Accuracy 0.5 with RS485 Port. 475 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 476 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 477 1 Sets auto trip indicating lamp . 478 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 479 Short Circuit Breaking capacity should not less than 25KA. 480 RELAYS 481 NURSES HOSTEL MAIN L.T PANEL 482 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 483 INCOMING 484 1 Nos. 200 Amp FP MCCB 25 KA, 485 BUSBARS 486 1 Nos. 250 Amp TPN busbars of aluminium alloy . 487 OUTGOING 488 5 Nos. 100 Amp FP MCCB 25 KA, with On, Off Indication lamp and A/V/KW meter 489 1 Nos. 63 Amp TP MCCB50 KA, with On, Off Indication lamp and A/V/KW meter 490 INSTRUMENTS 491 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 492 1 sets of 0-200Amp. digital type ammeter with ammeter selector switch. 493 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 494 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 495 1 Sets auto trip indicating lamp . 496 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 497 Short Circuit Breaking capacity should not less than 25KA. 498 RELAYS 499 12 FLAT NURSES BLOCK METER PANEL 1/2 500 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 501 INCOMING 502 1 Nos. 100 Amp FP MCCB 25 KA, 503 BUSBARS 504 1 Nos. 125 Amp TPN busbars of aluminium alloy . 505 OUTGOING 506 14 Nos. 40 Amp DP MCB 507 12Nos. 40Amp. KWh 1 Phase Energy meter 508 INSTRUMENTS 509 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 510 1 sets of 0-100Amp. digital type ammeter with ammeter selector switch. 511 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 512 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 513 1 Sets auto trip indicating lamp . 514 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 515 Cost of 1 Phase Energy meter is inclusive in above rates. 516 RELAYS 517 13 FLAT NURSES BLOCK METER PANEL 3/4 518 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 519 INCOMING 520 1 Nos. 100 Amp FP MCCB 25 KA, 521 BUSBARS 522 1 Nos. 125 Amp TPN busbars of aluminium alloy . 523 OUTGOING 524 15 Nos. 40 Amp DP MCB 525 13Nos. 40Amp. KWh 1 Phase Energy meter 526 INSTRUMENTS 527 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 528 1 sets of 0-100Amp. digital type ammeter with ammeter selector switch. 529 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 530 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 531 1 Sets auto trip indicating lamp . 532 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 533 Cost of 1 Phase Energy meter is inclusive in above rates. 534 RELAYS 535 MARRIED DOCTOR NRH HOSTEL & WARD BLOCK 536 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be OUTDOOR, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 537 INCOMING 538 1 Nos. 1250 Amp FP EDO ACB 50 KA, 539 BUSBARS 540 1 Nos. 1600 Amp TPN busbars of aluminium alloy . 541 OUTGOING 542 3 Nos. 400 Amp FP MCCB 50 KA, with On, Off Indication lamp and A/V/KW meter 543 2 Nos. 250 Amp FP MCCB 50 KA, with On, Off Indication lamp and A/V/KW meter 544 1 Nos. 200 Amp FP MCCB 50 KA, with On, Off Indication lamp and A/V/KW meter 545 2 Nos. 125 Amp TP MCCB50 KA, with On, Off Indication lamp and A/V/KW meter 546 INSTRUMENTS 547 1 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers. Class Accuracy 0.5 with RS485 Port. 548 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 549 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 550 1 Sets auto trip indicating lamp . 551 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 552 Short Circuit Breaking capacity should not less than 50KA. 553 RELAYS 554 MARRIED DOCTOR HOSTEL L.T PANEL 555 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 556 INCOMING 557 1 Nos. 400 Amp FP MCCB 25 KA, 558 BUSBARS 559 1 Nos. 500 Amp TPN busbars of aluminium alloy . 560 OUTGOING 561 5 Nos. 125 Amp FP MCCB 25 KA, with On, Off Indication lamp and A/V/KW meter 562 1 Nos. 63 Amp TP MCCB25 KA, with On, Off Indication lamp and A/V/KW meter 563 INSTRUMENTS 564 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 565 1 sets of 0-400Amp. digital type ammeter with ammeter selector switch. 566 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 567 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 568 1 Sets auto trip indicating lamp . 569 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 570 Short Circuit Breaking capacity should not less than 25KA. 571 RELAYS 572 12 FLAT DOCTORS BLOCK METER PANEL 1/2/3/4 573 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 574 INCOMING 575 1 Nos. 125 Amp FP MCCB 25 KA, 576 BUSBARS 577 1 Nos. 150 Amp TPN busbars of aluminium alloy . 578 OUTGOING 579 14 Nos. 40 Amp FP MCB 580 12Nos. 40Amp. KWh 3 Phase Energy meter 581 INSTRUMENTS 582 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 583 1 sets of 0-150Amp. digital type ammeter with ammeter selector switch. 584 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 585 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 586 1 Sets auto trip indicating lamp . 587 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 588 Cost of 3 Phase Energy meter is inclusive in above rates. 589 RELAYS 590 NRH HOSTEL L.T PANEL 591 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 592 INCOMING 593 1 Nos. 400 Amp FP MCCB 25 KA, 594 BUSBARS 595 1 Nos. 500 Amp TPN busbars of aluminium alloy . 596 OUTGOING 597 3 Nos. 160 Amp FP MCCB 25 KA, with On, Off Indication lamp and A/V/KW meter 598 1 Nos. 125 Amp FP MCCB 25 KA, with On, Off Indication lamp and A/V/KW meter 599 1 Nos. 63 Amp TP MCCB25 KA, with On, Off Indication lamp and A/V/KW meter 600 INSTRUMENTS 601 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 602 1 sets of 0-400Amp. digital type ammeter with ammeter selector switch. 603 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 604 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 605 1 Sets auto trip indicating lamp . 606 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 607 Short Circuit Breaking capacity should not less than 25KA. 608 RELAYS 609 PRIVATE WARD MAIN L.T PANEL 610 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 611 INCOMING 612 1 Nos. 250 Amp FP MCCB 25 KA, 613 BUSBARS 614 1 Nos. 320 Amp TPN busbars of aluminium alloy . 615 OUTGOING 616 6 Nos. 125 Amp FP MCCB 25 KA, with On, Off Indication lamp and A/V/KW meter 617 INSTRUMENTS 618 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 619 1 sets of 0-250Amp. digital type ammeter with ammeter selector switch. 620 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 621 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 622 1 Sets auto trip indicating lamp . 623 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 624 Short Circuit Breaking capacity should not less than 25KA. 625 RELAYS 626 4TH CLASS EMPLOYEE TYPE-1 RESIDENTIAL AREA MAIN L.T PANEL (OUTDOOR TYPE) 627 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be OUTDOOR, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 35kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 628 INCOMING 629 1 Nos. 800 Amp FP EDO ACB 25 KA, 630 BUSBARS 631 1 Nos. 1000 Amp TPN busbars of aluminium alloy . 632 OUTGOING 633 3 Nos. 125 Amp FP MCCB 25 KA, with On, Off Indication lamp and A/V/KW meter 634 8 Nos. 100 Amp FP MCCB25 KA, with On, Off Indication lamp and A/V/KW meter 635 3 Nos. 63 Amp FP MCCB25 KA, with On, Off Indication lamp and A/V/KW meter 636 INSTRUMENTS 637 1 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers. Class Accuracy 0.5 with RS485 Port. 638 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 639 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 640 1 Sets auto trip indicating lamp . 641 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 642 Short Circuit Breaking capacity should not less than 25KA. 643 RELAYS 644 Type-II Block Main L.T Panel 645 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 646 INCOMING 647 1 Nos. 125 Amp FP MCCB 25 KA, 648 BUSBARS 649 1 Nos. 150 Amp TPN busbars of aluminium alloy . 650 OUTGOING 651 2 Nos. 100 Amp DP MCB 652 2 Nos. 63 Amp DP MCB 653 INSTRUMENTS 654 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 655 1 sets of 0-150Amp. digital type ammeter with ammeter selector switch. 656 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 657 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 658 1 Sets auto trip indicating lamp . 659 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 660 Cost of 1 Phase Energy meter is inclusive in above rates. 661 RELAYS 662 12 TYPE-II RESIDENCE OUTDOOR TYPE METER PANEL 1/2/3/4 663 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 664 INCOMING 665 1 Nos. 100 Amp FP MCCB 25 KA, 666 BUSBARS 667 1 Nos. 150 Amp TPN busbars of aluminium alloy . 668 OUTGOING 669 15 Nos. 40 Amp DP MCB 670 12Nos. 40Amp. KWh 1 Phase Energy meter 671 INSTRUMENTS 672 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 673 1 sets of 0-150Amp. digital type ammeter with ammeter selector switch. 674 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 675 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 676 1 Sets auto trip indicating lamp . 677 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 678 Cost of 1 Phase Energy meter is inclusive in above rates. 679 RELAYS 680 17/15 TYPE-1 RESIDENCE OUTDOOR TYPE METER PANEL 1/2 681 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 682 INCOMING 683 1 Nos. 100 Amp FP MCCB 25 KA, 684 BUSBARS 685 1 Nos. 150 Amp TPN busbars of aluminium alloy . 686 OUTGOING 687 18 Nos. 40 Amp DP MCB 688 17Nos. 40Amp. KWh 1 Phase Energy meter 689 INSTRUMENTS 690 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 691 1 sets of 0-150Amp. digital type ammeter with ammeter selector switch. 692 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 693 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 694 1 Sets auto trip indicating lamp . 695 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 696 Cost of 1 Phase Energy meter is inclusive in above rates. 697 RELAYS 698 13 TYPE-1 RESIDENCE OUTDOOR TYPE METER PANEL 1/2 699 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 700 INCOMING 701 1 Nos. 100 Amp FP MCCB 25 KA, 702 BUSBARS 703 1 Nos. 125 Amp TPN busbars of aluminium alloy . 704 OUTGOING 705 14 Nos. 40 Amp DP MCB 706 13Nos. 40Amp. KWh 1 Phase Energy meter 707 INSTRUMENTS 708 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 709 1 sets of 0-100Amp. digital type ammeter with ammeter selector switch. 710 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 711 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 712 1 Sets auto trip indicating lamp . 713 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 714 Cost of 1 Phase Energy meter is inclusive in above rates. 715 RELAYS 716 11 TYPE-1 RESIDENCE OUTDOOR TYPE METER PANEL 1/2 717 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 718 INCOMING 719 1 Nos. 100 Amp FP MCCB 25 KA, 720 BUSBARS 721 1 Nos. 125 Amp TPN busbars of aluminium alloy . 722 OUTGOING 723 12 Nos. 40 Amp DP MCB 724 11Nos. 40Amp. KWh 1 Phase Energy meter 725 INSTRUMENTS 726 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 727 1 sets of 0-100Amp. digital type ammeter with ammeter selector switch. 728 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 729 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 730 1 Sets auto trip indicating lamp . 731 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 732 Cost of 1 Phase Energy meter is inclusive in above rates. 733 RELAYS 734 8 TYPE-1 RESIDENCE OUTDOOR TYPE METER PANEL 1/2 735 Design, Manufacturing, Supply, Commissioning & Testing of Meter Panel. The panel will be totally enclosed type with, free standing, floor mounted, outdoor duty, dust & vermin proof, , front/back operated, electrical panel fabricated from 2 mm thick M.S. Sheetas per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CTs, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness including providing of suitable size of compartment to mount 3 Phase or 1 Phase energy meter with hinge door provided with cutout to get meter reading. 736 INCOMING 737 1 Nos. 100 Amp FP MCCB 25 KA, 738 BUSBARS 739 1 Nos. 125 Amp TPN busbars of aluminium alloy . 740 OUTGOING 741 9 Nos. 40 Amp DP MCB 742 8Nos. 40Amp. KWh 1 Phase Energy meter 743 INSTRUMENTS 744 1 sets of 0-500V digital type Voltmeter with voltmeter selector switch. 745 1 sets of 0-100Amp. digital type ammeter with ammeter selector switch. 746 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 747 1 Sets breaker ON & OFF indicating lamp (one set for each incoming breaker). 748 1 Sets auto trip indicating lamp . 749 Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. 750 Cost of 1 Phase Energy meter is inclusive in above rates. 751 RELAYS 752 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 753 6 sq. mm 2 core 754 10 sq. mm 2 core 755 25 sq. mm 3-1/2 core 756 35 sq. mm 3-1/2 core 757 50 sq. mm 3-1/2 core 758 70 sq. mm 3-1/2 core 759 95 sq. mm 3-1/2 core 760 150 sq. mm 3-1/2 core 761 240 sq. mm 3-1/2 core 762 300 sq. mm 3-1/2 core 763 400 sq. mm 3-1/2 core 764 Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. 765 6 sq. mm 2 core 766 10 sq. mm 2 core 767 25 sq. mm 3-1/2 core 768 35 sq. mm 3-1/2 core 769 50 sq. mm 3-1/2 core 770 70 sq. mm 3-1/2 core 771 95 sq. mm 3-1/2 core 772 150 sq. mm 3-1/2 core 773 240 sq. mm 3-1/2 core 774 300 sq. mm 3-1/2 core 775 400 sq. mm 3-1/2 core 776 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 777 100 mm width X 50 mm depth X 1.6 mm thickness 778 300 mm width X 50 mm depth X 1.6 mm thickness 779 450 mm width X 62.5 mm depth X 2 mm thickness 780 600 mm width X 62.5 mm depth X 2 mm thickness 781 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way SPN DB 782 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4WAY TPN DB 783 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar formounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4WAY VTPN DB 784 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6WAY TPN DB 785 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8WAY VTPN DB 786 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8WAY TPN DB 787 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 788 Single pole 789 Double pole 790 Triple pole 791 Triple pole and neutral 792 S&F of 40 Amp. TP MCB (10 KA) C CurveCAT-A 793 S&F of 63 Amp. TP MCB (10 KA) C CurveCAT-A 794 S&F of 6 Amp. to 40 Amp. 4 pole MCB (10 KA) C Curve CAT-A 795 S&F of 6 Amp. to 63 Amp. 4 pole MCB (10 KA) C Curve CAT-A 796 Dismantlinmg of ExistingPanel & shifting of same at appropriate location as per Direction of Engineer In-charge 797 Repairing of Floor L.T panel including painting, fixing of rating plates, repairing of door lock etc. as required. 798 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 799 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 800 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 801 EXTERNAL LIGHT FEEDER PILLAR 802 Supply installing testing & commissioning of outdoor type Distribution Panel compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below. 803 Incoming 804 63 Amp. 25 KA FP MCCB1 No. 805 Suitable contractor and timer for down & dusk 806 100 Amp. TPN Alu. Bus bar 807 Outgoing 808 25 Amp. 10KA FP MCB5 No. 809 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 810 6 sq. mm 4 core 811 10 sq. mm 4 core 812 16 sq. mm 4 core 813 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 814 6 sq. mm 4 core 815 4 X 10 sq. mm (25mm) 816 4 X 16 sq. mm (28mm) 817 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge . 818 6 sq. mm 819 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness backlite sheet & 4 way connectorwith single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts,xcavation & back filling and Required T&P completee in all respect. 820 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness backlite sheet & 4 way connectorwith Double arm bracket (1 Mtr length) on RCCoundation including the cost of foundation, foundation bolts, xcavation & back filling and Required T&P completee in all respect. 821 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuserwith driver set suitable1.5 Sqmm 3 core multistand copper unarmored cable suitable lenght and 1 no 10 Amp SPMCBfor 52 watt to 72 Watt. Confirming to IP65 and above Protection complete in all respect. Cat.-AAA 6600-7920 system lumens High Power LED with lenses, > 110lm/W, PF>0.95, Potted driver set (Not Circuitory) Phase to Phase Protection at 440 V & > 300V auto cut re-start feature. with 5 year warantee. as peras per direction of E/I. 822 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 823 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of+B944 2.7 metre long etc. with charcoal/ coke and salt as required. 824 Supply and laying of 25 mm X 3mm G.I. strip from earth electrode irectly in the ground as required complete in all respect. 825 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-07-2024 Regarding BOQ Technical Bid 07-08-2024
2 27-07-2024 LT PANEL MAKE Technical Bid 07-08-2024

Key Value

Document Fees
INR 8850 /-
EMD
INR 2200000.0 /-
Tender Value
INR 10.59 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail