}

Tender For Estimate For Electrification Of 01 No. Habitation And 15 Nos. House Hold Under Pvtg Scheme Under Pagara D.C. Of Onm Division Guna, Estimate For Electrification Of 01 No Habitation And 15 Nos House Hold Under Pvtg Scheme Under Pagara Dc Under O&, Guna-Madhya Pradesh

Boards / Undertakings / PSU has published Tender For Estimate For Electrification Of 01 No. Habitation And 15 Nos. House Hold Under Pvtg Scheme Under Pagara D.C. Of Onm Division Guna, Estimate For Electrification Of 01 No Habitation And 15 Nos House Hold Under Pvtg Scheme Under Pagara Dc Under O&. Submission Date for this Tender is 18-07-2024. Electrification Work Tenders in Guna Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44211109
Tender For Estimate For Electrification Of 01 No. Habitation And 15 Nos. House Hold Under Pvtg Scheme Under Pagara D.C. Of Onm Division Guna, Estimate For Electrification Of 01 No Habitation And 15 Nos House Hold Under Pvtg Scheme Under Pagara Dc Under O&
Open Tender
Indian
Madhya Pradesh
Guna
18-07-2024

Tender Details

tender for Estimate For Electrification Of 01 No. Habitation And 15 Nos. House Hold Under Pvtg Scheme Under Pagara D.C. Of Onm Division Guna, Estimate for Electrification of 01 No Habitation and 15 Nos House Hold under PVTG Scheme under Pagara DC under O&M Dn. Guna..Estimate No. & Date :- 15-289-120665-23-00016 dt. 15.02.2024, STC No.:- 14 dt. 16.02.2024, O&M No. :- 7702 dt. 15.02.2024, Project No. :- 81291 Sl. No. Item Description 1 Provision :- Schedule A - 11 KV LINE ON 8 Mtr PCC Pole - 0.56 KMSchedule B - Under Ground Railway CrossingSchedule C - 11 KV DP Structure ON PCC- 02 NoSchedule D - L.T. LINES ON PCC 8.0 Mtr. - 0.31 KMSchedule E - 11/0.4 KV, 25KVA DTR ON PCC- 01 NoSchedule F - Kaccha House.Schedule G - Service Connection. Note:-Erection Charge Including with All Material Transportation from Area store Guna/Gwalior/Bhopal to working Site 2 140 Kg.,8.0 Mtrs. long PCC pole 3 Erection of 140 Kg.,8.0 Mtrs. long PCC pole (including Pit Digging - Base Padding of Pole by Stone Block/Pre Cost Block, Pole Erection, Back Filling/Boulder, Earthing Coil)} 4 11 KV V cross arm 65X65X6 mm. angle type 5 Erection Charges for 11 KV V cross arm 65X65X6 mm. angle type 6 Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 7 11 KV Top clamp 65X65X6 mm. angle type 8 Erection Charges for11 KV Top clamp 65X65X6 mm. angle type 9 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 10 11 KV Pin Insulator Polymer Composit (5 KN) 11 Erection Charges for 11 KV Pin Insulator Polymer Composit (5 KN) 12 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 13 Stay set complete without Stay wire 16 mm. (Painted) 14 Stay set 16 mm. Complete erection including Pit digging, binding of stay wire at eye bolt , stay insulator and anchor rod &tigtning on pole) 15 STAY WIRE 7/3.15 MM.(7/10SWG) 16 Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 17 Stay Insulators 90X65mm 18 Back filling of poles with boulders 19 G.I. WIRES 4.0 MM. (8 SWG) 20 Erection Charges for G.I. WIRES4.0 MM. (8 SWG) 21 Stone Block/Pre cast block for base pedding(450X450X75MM) 22 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 23 Erection Charges for Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 24 Red oxide paint 25 Erection Charges for Red oxide paint 26 Aluminium paint 27 Erection Charges for Aluminium paint 28 Danger Boards Enamelled 11 KV 29 Erection Charges for Danger Boards Enamelled 11 KV 30 Aluminium Binding wire and tape 31 M.S.Nuts with Bolts 32 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 33 Erection Charges for Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 34 AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) 35 Erection Charges for Stringing of AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) 36 GI Pipe 150 mm B Grade 37 Erection Charges for GI Pipe 150 MM B Grade under Track along DP by HDD Process (including HDD) 38 GI Pipe 150 mm A Grade 39 Erection Charges for GI Pipe 150 mm A Grade (along DP) 40 Outdoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 300 sq mm 41 Erection Charges for Cable end termination/straight throughkits for all 3 core 11 KV cable size with lugs 42 9 KV Gapless type Metal oxide (10 KA) Polymer for 33/11 kv S/s type FOR DTR 43 Erection Charges for 9 KV Gapless type Metal oxide (10 KA) Polymer for 33/11 kv S/s type FOR DTR 44 G.I. WIRES 5.0 MM. (6 SWG) 45 Bi Metallic Clamp for Power Transformer of Brass Flat 50x50x10MM 46 Erection Charges for Bi Metallic Clamp for Power Transformer of Brass Flat 50x50x10MM 47 Cable marker 48 Erection Charges for Cable marker 49 Concreting of cable marker @ 0.2 Cmt.per cable marker 50 Erection Charges for Concreting of cable marker @ 0.2 Cmt.per cable marker 51 G.I. STRIP 25X3 MM1 52 Erection Charges for G.I. Strip 25x3 mm. for laying complete earthing including welding and back filling 53 G.I.Pipe 40 mm Dia C grade type 54 Erection Charges for G.I. Pipe 40 mm dia errection with pit digging & back filling 55 Bentonite compound powder (DTR) 56 Galvanized nut & bolt with washer 57 G.I. M S FLAT 65X8 mm 58 11 KV Under-Ground XLPE armoured Cable 3X300 Sq.mm. 59 Erection Charge for 11 KV Under-Ground XLPE armoured Cable 3X300 Sq.mm. 60 H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-13 mtr. Long = 408.1 kg 61 Erection of 1H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-13 mtr. Long = 408.1 kg (including Pit Digging - Base Padding of Pole by Stone Block/Pre Cost Block, Pole Erection, Back Filling/Boulder, Earthing Coil)} 62 D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel 63 Erection Charges for D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel 64 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 65 11 KV(45KN) Composite Polymer Disc Insulators 66 Erection Charges for 11 KV(45KN) Composite Polymer Disc Insulators with Strain Hardware 67 11 KV Strain hardware (T&C type) fittings 68 Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 8 ft (2.4 mtr ) centre DP 69 Erection Charges for Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 8 ft (2.4 mtr ) centre DP 70 Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) 71 Stay set 20 mm. complete without Stay wire (Painted) 72 Stay set 20 mm. Complete erection including Pit digging, binding of stay wire at eye bolt , stay insulator and anchor rod &tigtning on pole) 73 STAY GI WIRE 7/4.00 MM.(7/8 SWG) 74 Concreting of structures & foundation (1:3:6) 75 Erection Charges for Concreting of structures & foundation (1:3:6) 76 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 77 Erection Charges for Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 78 LT A.B Cable tension clamps (Galvanized) 79 Erection Charges for LT A.B Cable tension clamps (Galvanized) 80 LT A B cable Suspension clamps (Galvanized) 81 Erection Charges for LT A B cable Suspension clamps (Galvanized) 82 Clamps for neutral for AB Cable 83 Erection Charges for Clamps for neutral for AB Cable 84 Piercing connector Type-I for single/three phase (Main 16-50 sqmm tap-off 16-50 sqmm) 85 Erection Charges for Piercing connector Type-I for single/three phase (Main 16-50 sqmm tap-off 16-50 sqmm) 86 Piercing connector Type-II (Main 16-50 sqmm tap-off 16-50 sqmm) 87 Erection Charges for Piercing connector Type-II (Main 16-50 sqmm tap-off 16-50 sqmm) 88 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 89 Single Phase Service connection box (Deep Drwan Metal Service Connection Boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- 90 Handling & Installation ofSingle Phase Service connection box (Deep Drwan Metal Service Connection Boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- 91 LT XLPE Arial Bunch XLPE Cable 3X25 + 1X16 + 1X25 Sq mm. with aluminium alloy bare messenger wire 92 Stringing of LT XLPE Arial Bunch XLPE Cable 3X25 + 1X16 + 1X25 Sq mm. with aluminium alloy bare messenger wire 93 11/0.4 KV Distribution transformer 25 KVA (Conventional) Aluminium Wound) (Rep-WGP) 94 Handling & Installation ofDistribution Transformer (25 KVA DTR) on DP, tightening with turn buckles on both sides, poles clamping and boting of base jumpering on HT side (Including hydra charges in urban area and chain pully charges in rural area) 95 D.O.Mounting Channel 75x40x6mm 96 Erection Charges for D.O.Mounting Channel 75x40x6mm 97 11 KV D.O. Fuse Unit Polymer type 98 Erection Charges for 11 KV D.O. Fuse Unit Polymer type 99 Transformer mounting Channel (100X50x6 mm.) 100 Erection Charges for Transformer mounting Channel (100X50x6 mm.) 101 Trans. Belting with 50 X 50 X 6 mm.angle with two cross fixing channels 102 Complete jumpering of DTR 103 Bi-metallic clamps Distribution Transformers Bushing 104 Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC 105 Meter cum protection box for 25 KVA DTR 106 Handling & Installation of Meter cum protection box 25 KVA on DP, complete wiring, connecting LT cable on bushing and LT feeders (2 Nos.) 107 Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box 108 Handling & Installation of Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box 109 G.I. STRIP 25X3 MM1 (DTR) 110 Erection Charges for G.I. Strip 25x3 mm. for laying complete earthing including welding and back filling (DTR) 111 G.I.Pipe 40 mm Dia C grade type (DTR) 112 Erection Charges for G.I. Pipe 40 mm dia errection with pit digging & back filling (DTR) 113 Bentonite compound powder 114 9 KV Gapless type Metal oxide (10 KA) Polymer for 33/11 kv S/s type 115 Erection Charges for 9 KV Gapless type Metal oxide (10 KA) Polymer for 33/11 kv S/s type (DTR) 116 XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts 117 Erection Charges for XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts 118 XLPE Cable 1 core unarmoured 35 sqmm Aluminium conductor 1100 Volts 119 Erection Charges for XLPE Cable 1 core unarmoured 35 sqmm Aluminium conductor 1100 Volts 120 Wooden Board 10x8 (including with Erection Charges) 121 Switch Board (including with Erection Charges) 122 3 Pin 5A Socket (Two no. Piano type switch, Bulb Bakelite Holder with wiring & E (including with Erection Charges) 123 Rack Bolt/Screw (including with Erection Charges) 124 G.I. Wire 3.15 mm. (10 SWG) (including with Erection Charges) 125 PVC 2 CORE UN ARMOURED 2.5 SQMM ALUMINIUM CONDUCTOR 126 Stringing of PVC 2 CORE UN ARMOURED 2.5 SQMM ALUMINIUM CONDUCTOR 127 Single phase Electronic meter with data downloading facility & box 5-30 Amps. 128 Handling & Installation of Single phase Electronic meter with data downloading facility & box 5-30 Amps. 129 LED Lamp with 9 Watt (Complete) (including with Erection Charges) 130 PVC/Rubber Bushes (including with Erection Charges) 131 MCB of 16 Amp (including with Erection Charges) 132 GST @ 18%

Key Value

Document Fees
INR 2360 /-
EMD
INR 23000.0 /-
Tender Value
INR 11.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail