Tender For Construction Block-1 In District Banda, Electrification Work In New Office Building Of Pwd Banda, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell/Street Light On Wall Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor , banda-Uttar Pradesh

Government Departments has published Tender For Construction Block-1 In District Banda, Electrification Work In New Office Building Of Pwd Banda, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell/Street Light On Wall Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor . Submission Date for this Tender is 26-07-2024. Uniform Tenders in banda Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44184965
Tender For Construction Block-1 In District Banda, Electrification Work In New Office Building Of Pwd Banda, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell/Street Light On Wall Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor
Open Tender
Indian
Uttar Pradesh
Banda
26-07-2024

Tender Details

Tender for construction block-1 in district Banda, electrification work in new office building of PWD Banda, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell/Street light on wall point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (PVC Conduit & G.I. Box existing at site.) 2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (PVC Conduit & G.I. Box existing at site.) 3 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 4 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 5 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire)(PVC Conduit & G.I. Box existing at site.) 6 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)(PVC Conduit & G.I. Box existing at site.) 7 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 X 4 sq. mm + 1 X 4 sq. mm earth wire) (PVC Conduit & G.I. Box existing at site.) 8 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(2 X 6 sq. mm + 1 X 6 sq. mm earth wire)(PVC Conduit & G.I. Box existing at site.) 9 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(2 X 6 sq. mm + 1 X 6 sq. mm earth wire) 10 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(2 X 10 sq. mm + 1 X 6 sq. mm earth wire)(PVC Conduit & G.I. Box existing at site.) 11 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(2 X 10 sq. mm + 1 X 6 sq. mm earth wire) 12 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 X 10 sq. mm + 2 X 6 sq. mm earth wire)(PVC Conduit & G.I. Box existing at site.) 13 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 X 10 sq. mm + 2 X 6 sq. mm earth wire) 14 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 X 16 sq. mm + 2 X 6 sq. mm earth wire) (PVC Conduit & G.I. Box existing at site.) 15 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 X 16 sq. mm + 2 X 6 sq. mm earth wire) 16 Supply and drawing following sizes of FRLS PVC insulated cu. Conductor, single core cable in the existing surface/recessed steet/PVC conduit (1 X 1.5 sq. mm) 17 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way(4 + 12), Double door 18 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6 way(6 + 18), Double door 19 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole) 20 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 21 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole & Neutral 22 Supplying and fixing of 40 amp. FPMCB240V/415 50 Hz, (10 KA) C-Curve. Make:- Havells or Eq. 23 Supplying and fixing of 63 amp. TPMCB240V/415 50 Hz, (10 KA) C-Curve. Make:- Havells or Eq. 24 Supplying and fixing of 63 amp. FPMCB240V/415 50 Hz, (10 KA) C-Curve. Make:- Havells or Eq. 25 Supplying and fixing of 100 amp. FPMCB240V/415 50 Hz, (10 KA) C-Curve. Make:- Havells or Eq. 26 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 27 Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following Triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. for 4 way, Double door TPN MCB DB 28 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 29 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 30 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 31 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 32 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 33 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 34 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 35 Installation, testing and commissioning of ceiling fan/wall fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box/ cost of screw, gulli & all T&P & labour etc. as required. 36 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 37 Providing and fixing circular/ Hexagonal GI box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet with its top surface hacked for proper bonding, top lid shall be screwed into the GI box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 38 Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 39 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 40 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 41 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 42 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. 43 Supply andmaking end termination with brass compression gland and al. lugs for following size PVC insulated/ XLPE al. conductor cable of 1.1 KV grade. 44 10 Sq. mm 2 core. 45 10 Sq. mm 4 core. 46 16 Sq. mm 4 core. 47 35 Sq. mm 3½ core. 48 240 Sq. mm 3½ core. 49 Supplying and installing following size of perforated pre-painted M.S. cable trays Tees with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness 50 Computer Board (6 Modular Board with 5/6 A Switch & 3 Pin 5/6 A Socket outled 2-2 Nos. Submain Extra) 51 T.V. Board (8 Modular Board with 5/6 A Switch & 3 Pin 5/6 A Socket outled 2-2 Nos., TV antenna socket outlet 1 No. Blanking Plate-1 No.Submain Extra) ( 1.5 Sq. 2 Nos. Cu. Submain Extra) 52 Aquaguard Board (6 Modular Board with 15/16 A Switch & 6 Pin 15/16 A socket outlet 2-2 Nos. )( 2.5 Sq. 2 Nos. Cu. Submain Extra) 53 Supply and fixing of Mirror Light Philips or eqi. 54 Supply and fixing of LED Tube Light with heavy duty Metal Box type Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. 2620 system lumens, >120 Lm/W, PF>0.95, THD<10%, CRI>80, sheet thickness min 0.8mm, Tube with aluminium heat sink,>300V over voltage protection, 2.5 KV internal Surge Protection, with 5year warrantee. 55 Supply and fixing of LED Bulb 12 watt. Complete in all respect. 56 Supply and fixing of IP 20, Front Lit, Mid Power SMD type LEDLight, recess/Surface mounting round 18 Watt to 20 Watt, Cut out Min 150 mm, Height Min 40 mm,, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, High purity / transmisivity UV Stabilized Non yellowish diffuser/Reflector for uniform light distribution, detachable driver set, suitable for 24 Hr Continuous Operation, Complete in All respect.2160-2400 system lumens, >120 Lm/W, PF>0.95, THD <10% at full load, CRI >80, , >300V over voltage protection, 2.5 KV internal Surge Protection, with 5 years warrantee. 57 16 A 3 pin Plugtop with Indicator (Heavy Duty) Havells or equi. 58 SITC of 63 Amp. Four pole change over switch complete in all respect. 59 Supply of300 mm. sweep metalic body fresh air fan Havells or equilivant. 60 Supply of1400 mm. sweep ceiling fan Havells or equilivant. 61 Supply and fixing of LED Street light Fitting with mandatory driver set, having die cast aluminium body with toughend glass/ UV stabilized PC Cover and lenses suitable for 45 Watt. to 50 Watt, Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including Labour. CAT-AAA5400-6000 system lumens, High Power LED with lenses, 120Lm/W, PF>0.95, THD <10% at full load, CRI >70, Potted driver Set in Metal housing (NotCircuitory), Phase to Phase protection at 440V, >300V over voltage auto cut and restart feature, 4 KV internal Surge Protection, with 5 years warrantee 62 Supply and fixing of decorative 40 Watt to 45 Watt, LED Post top indirect light luminaire having Pressure die cast aluminium body and UV Stabilized PC Clear/ frosted glass cover, with driver set confirming to IP 66 and IK 08 protection, Potted driver (Not circuitory) complete in all respect. CAT-AAA 4800-5400 system lumens, >120 Lm/W, PF>0.95, THD <10% at full load, CRI >70, >300V Over Voltage Protection and auto restart feature, 4 KV internal Surge Protection, with 5 yearswarrantee 63 Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base. Havells or equilivant. 64 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 65 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 66 Supply and laying of following sizealuminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at dopth of 750 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on surface the cable run shall be fixed on M.S. clamp etc. of suitable size. the armouring of the cable shall be properly connected with earth conductor by clamps etc:- 67 6 Sq.mm 2 core. 68 35 Sq.mm 3½ core. 69 240 Sq.mm 3½ core. 70 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mountedon non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incoming:- 250 Amp. FP MCCB 36 KA - 1 No.Outgoing:- 100 Amp. FP MCCB 36 KA - 2 Nos. 63 Amp. FP MCCB 36 KA - 2 Nos. 32 Amp. FP MCCB 36 KA - 2 Nos. 71 Supply & fixing of 20 mm dia medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring. 72 Supply & fixing of 25 mm dia medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring. 73 Supply & fixing of 32 mm dia medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring. 74 S/F of M.S. Drum with luvers making hole complete in all respect. 75 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of light point/fan point/exhaust fan point/call bell point/ Street Light point. 76 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of twin control light point. 77 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Submain). 78 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Submain). 79 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of (2 X 4 sq. mm + 1 X 4 sq. mm earth wire Submain). 80 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of (2 X 6 sq. mm + 1 X 6 sq. mm earth wire Submain). 81 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of (2 X 10 sq. mm + 1 X 6 sq. mm earth wire Submain). 82 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of (4 X 10 sq. mm + 2 X 6 sq. mm earth wire Submain). 83 Supply & fixing of medium class PVC Conduit and metal box along with assesories in surface/recess including cuting the wall and making good for wiring of (4 X 16 sq. mm + 2 X 6 sq. mm earth wire Submain). 84 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door 85 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door 86 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way(4 + 12), Double door 87 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6 way(6 + 18), Double door 88 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 89 Add : GST 18% Extra

Key Value

Document Fees
INR 854 /-
EMD
INR 302000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail