Tender For The Work Of Internal Electrification At Government Training And Extension Center Sultanpur Under District Industries Center, 1 Point Wiring : 2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc In, sultanpur-Uttar Pradesh

Government Departments has published Tender For The Work Of Internal Electrification At Government Training And Extension Center Sultanpur Under District Industries Center, 1 Point Wiring : 2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc In. Submission Date for this Tender is 22-07-2024. Electrification Work Tenders in sultanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44162326
Tender For The Work Of Internal Electrification At Government Training And Extension Center Sultanpur Under District Industries Center, 1 Point Wiring : 2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc In
Open Tender
Indian
Uttar Pradesh
Sultanpur
22-07-2024

Tender Details

Tender for the work of internal electrification at Government Training and Extension Center Sultanpur under District Industries Center, 1 Point Wiring : 2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 3 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 4 Submains : 5 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 6 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 7 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 8 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 10 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 11 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 12 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 13 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 14 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 15 MCBs & DB’s : 16 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door 17 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 18 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 19 Earthing Work : 20 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 21 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 22 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 23 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 24 Lighting Fixtures (Lights/Fans) : 25 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 26 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 27 Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) 28 Armoured Cables (Cable/Gland/Lug) : 29 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 95 sq mm x 3-1/2core 30 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 95 sq mm x 3-1/2core 31 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 32 size 50 sq mm 33 size 95 sq mm 34 Non-Schedule Items 35 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 36 PART-B CCTV WORK 37 Supply, Installation & testing of Outdoor/Indoor 1080p HD indoor IP dome camera with 1/2.8 CMOS sensor pixel 1920 x 1080, IR on at 30IRE, 1/30s, 30fps, IR - 30 mtr, dynamic range 90db, true day/night, automatic electronic shutter, video compression H.264, motion/tamper, privacy mask, motion detection, auto varifocal lens 3 to 9 mm lens, audio - 1/1 channel in/out, full duplex audio, audio compression AAC, G.711, memory card slot (support up to 64GB), ONVIF profile S, CE, UL, FCC certified. 38 Supply, Installation, Testing & Commissioning of 8 Channel Digital Video Recorder with specifications as follow: Supported Image Format h.264 , H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 8 ; RAID 5, 320MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 4x 6TB can be installed. Certification: UL, CE, BIS, FCC. 39 6U rack with all accessories 40 Supply and laying of 3 core 1.5 sqmm copper cable unarmoured 41 Supply and laying of CAT 6 UTP cable 42 Supply and laying of 25mm dia PVC conduit. 43 Supply, installation and commissioning of workstation latest intel i7 7th generation processor, intel chipset motherboard, 8 GB DDR3 RAM, 2 TB SATA HDD at 7200 rpm, graphics card 2GB dedicated RAM with dual display ports DVI/HDMI port, DVD writer, Giga LAN card, keyboard, optical mouse as per list approved makes TFT monitors 21inch or bigger. 44 SITC of 40 flat screen HD professional LED suitable for 24x7 operation with remote control and wall mount unit / floor stand complete with making connection etc as per list of approved makes. 45 Supply, installation and testing of UPS 1 KVA capacity. 46 PART-C D.G.SET 47 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping. 48 The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class H or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables 49 DG Set Compatible for synchronising Panel 50 50 KVA 51 Armoured Cables (Cable/Gland/Lug) : 52 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 50 sq mm x 3-1/2core 53 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 50 sq mm x 3-1/2core 54 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 50 sq mm 55 Earthing Work : 56 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 57 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 58 PART-DSolar Panel 59 Supply, Installation, Testingand Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/ Poly Crystal line silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete as required:-a)Solar Photo voltaic Module of capacity 330 W porabove , manufactured in India, conforming to IS14286/ IEC61215 ,IS/IEC61730 - Part-1,IS/IEC61730 - Part-2. Solar Photo voltaic Module conversion efficiency shall not be less than 16.5% .PV modules used in solar power plants/ systems must be warranted for the in output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% attheend of 25 years.b) Power Conditioning Unit (PCU) of 350-800 VDC Input voltage range and 400 VAC, three phase, 4wire, 50Hz+/- 5 Hz, output voltage suitable to generate ACP ower with efficiency not less than 97%, to talharmonic distortion less than 3% and suitable for ambient temperature from 0 to50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d)FixingofArrayjunctionbox&MainjunctionboxwithIP65protectionandterminationarrangementforincomingandoutgoingcablealongwithglands,lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f)Connections&Interconnectionsbysupplying&fixingrequiredsizeXLPEinsulatedcopperconductor1.1kVgradearmouredpowerandcontrolcablesbetweensolarmodules,mainpowercabletogridsupplyPCUunitalongwithsupplying&fixingofnecessarychannel/ 60 Less 5% Department charge

Key Value

Document Fees
INR 1180 /-
EMD
INR 15600.0 /-
Tender Value
INR 15.53 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail