| 1 | (Supply Part) 33/11 KV, 3.15 MVA Power Transformer |
| 2 | Prov. Power transformer (3.15mva 33/11KV, ONAN,OLTC, Outdoor) |
| 3 | Prov. 33KV control and relay (CR) Panel (33KV incomer) (numeric relay, IEC 61850) |
| 4 | Prov. 33KV VCB (36 kv 1250A, 26.2KA outdoor type) |
| 5 | Prov. 33 KV isolator (1250A, 25KA Without earth switch) |
| 6 | Prov. 33KV LA/ Surge arrestor (33kv,10ka station class, ZN0, Porceline) |
| 7 | Prov. 33KV Current transformer (33kv, single phase multi ratio, multi core outdoor) (1no. Per phase) 400-200/1-1-1Amp. |
| 8 | Prov. 11KV incomer bus control and relay with PT (CR Panel with VCB (12kv, 1250 Amp, 25 KA) (Numeric relay IEC 61850) 2 Nos. incomers with CT ratio 400-200/1-1-1Amp and outgoing feeders 200-100/1-1-1Amp. |
| 9 | Prov. 11KV cable (11kv 400mm2 ,XLPE , 3core, armoured)(Transformer to 11kv bus) ( 50 M + Spare -50m) |
| 10 | Prov. 11KV Cabel Termination kit ( 400mm2 outdoor)Set |
| 11 | Prov. 11KV Cabel Termination kit ( 400mm2 indoor) |
| 12 | Prov. RS joist size 4200x250x125mm supports for CT base |
| 13 | Bus Bar |
| 14 | Prov. 3 disc insulator tension string complete |
| 15 | Prov. ACSR Conductor 200sq mm |
| 16 | Prov. PG clamp |
| 17 | Prov.T- Connector |
| 18 | Prov MS flat 50x6mm |
| 19 | (Erection Part) 33/11 KV, 3.15 MVA Power Transformer & other equipments |
| 20 | Erection chargesof Isolator |
| 21 | Erection charges lightening arrestor |
| 22 | Erection charges11 KV Pannel with CT and breaker |
| 23 | Erection charges of Power transformer |
| 24 | Erection charges of power cable |
| 25 | Erection chargesof Bus Bar |
| 26 | Erection charges of 33 KV VCB |
| 27 | Erection charges of 33 KV CT |
| 28 | Erection charges of 33 KV C&R Pannel |
| 29 | Erection charges of 33 KVEnd termination kit |
| 30 | Transportation Charges |
| 31 | Civil work V C B Foundation |
| 32 | Earth work in excavation by mechanical means (Hydraulic excavator)/manualmeansinfoundationtrenchesordrains(not exceeding1.5minwidthor10sqmonplan),includingdressing of sides and ramming of bottoms, lift upto 1.5 m, including getting outtheexcavatedsoilanddisposalofsurplusexcavatedsoilas directed, within a lead of 50 m. All kinds of soil. |
| 33 | Providingandlayinginpositioncementconcrete ofspecified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1Cement :3 coarsesand): 6graded stone aggregate 40 mm nominal size) |
| 34 | Centeringandshutteringincludingstrutting,proppingetc.andremoval of form |
| 35 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 36 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets,columns,pillars,piers,abutments,postsandstrutsetc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement:1.5coarsesand):3gradedstoneaggregate20mm nominal size) |
| 37 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinthlevelThermo-Mechanically Treatedbarsofgrade Fe-500Dor more. |
| 38 | Civil WorkCT-PT & L A Foundation |
| 39 | Earth work in excavation by mechanical means (Hydraulic excavator)/manualmeansinfoundationtrenchesordrains(not exceeding1.5minwidthor10sqmonplan),includingdressing of sides and ramming of bottoms, lift upto 1.5 m, including getting outtheexcavatedsoilanddisposalofsurplusexcavatedsoilas directed, within a lead of 50 m. All kinds of soil. |
| 40 | Providingandlayinginpositioncementconcrete ofspecified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1Cement :3 coarsesand): 6graded stone aggregate 40 mm nominal size) |
| 41 | Centeringandshutteringincludingstrutting,proppingetc.andremoval of form |
| 42 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 43 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets,columns,pillars,piers,abutments,postsandstrutsetc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement:1.5coarsesand):3gradedstoneaggregate20mm nominal size) |
| 44 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinthlevelThermo-Mechanically Treatedbarsofgrade Fe-500Dor more. |
| 45 | Prov.& fixing of 18 Watts LED Lamp with complete fittings |