}

Tender For Supply, Installation, Testing & Commissioning Of Internal Electrical Works For Tower - 2 (2Nd, 3Rd, 4Rth Floor And Commercial Court 5Th Floor) At Gnida Office Building Sector Kp-Iv Greater Noida, 1 (A) S.H. - I Main & Sub Main Cables(For Seco, noida-Uttar Pradesh

Local Bodies has published Tender For Supply, Installation, Testing & Commissioning Of Internal Electrical Works For Tower - 2 (2Nd, 3Rd, 4Rth Floor And Commercial Court 5Th Floor) At Gnida Office Building Sector Kp-Iv Greater Noida, 1 (A) S.H. - I Main & Sub Main Cables(For Seco. Submission Date for this Tender is 19-07-2024. Storage Chests and Cabinets and Trunks Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44128432
Tender For Supply, Installation, Testing & Commissioning Of Internal Electrical Works For Tower - 2 (2Nd, 3Rd, 4Rth Floor And Commercial Court 5Th Floor) At Gnida Office Building Sector Kp-Iv Greater Noida, 1 (A) S.H. - I Main & Sub Main Cables(For Seco
Open Tender
Indian
Uttar Pradesh
Noida
19-07-2024

Tender Details

Tender For Supply, installation, testing & commissioning Of Internal Electrical Works For Tower - 2 (2Nd, 3Rd, 4Rth Floor And Commercial Court 5Th Floor) At Gnida Office Building Sector Kp-Iv Greater Noida, 1 (A) S.H. - I MAIN & SUB MAIN CABLES(For Second,Third and Fourth Floor) 2 Supply of following sizes of 1.1KV grade multicore aluminium conductor FRLS insulated and FRLS sheathed armoured cable conforming torelevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant) 3 3.5 core,70 sq.mm. 4 3.5 core,50 sq.mm. 5 4 core,16 sq.mm. 6 4 core,10 sq.mm. 7 4 core,6 sq.mm. 8 4 core,4 sq.mm. 9 2 core,6 sq.mm. 10 Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 11 3½ X 70 sq. mm (38mm) 12 3½ X 50 sq. mm (35mm) 13 4 X 16 sq. mm (28mm) 14 4 X 10 sq. mm (25mm) 15 4 core,6 sq.mm.(25 mm) 16 4 core,4 sq.mm. (25 mm) 17 2 X 6 sq. mm (19mm) 18 Fabricating & installating following sizes of Perforated Type G.I. cable tray including horizontal & vertical bends, reducers, tees, cross members and other accessories as required & duly suspended from the ceiling with G.I.. suspenders etc. as required. 19 100mm x 40mm x 1.6mm 20 150mm x 40mm x 1.6mm 21 300mm x 40mm x 1.6mm 22 Supply, designing, fabrication and installation ofM.S. Angle / channel etc. complete as required. 23 MV CABLE LAYING- 24 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 25 Upto 35 sq. mm (clamped with 1mm thick saddle) 26 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 27 POINTWIRING 28 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 29 Group C 30 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 31 Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 32 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 33 2x2.5sq mm + 1x2.5 sq mm earth wire 34 2x4.0sq mm + 1x4.0 sq mm earth wire 35 2x6.0sq mm + 1x6.0 sq mm earth wire 36 2x10.0sq mm + 1x10.0 sq mm earth wire 37 2x16.0sq mm + 1x16.0 sq mm earth wire 38 4x6.0sq mm + 2x6.0 sq mm earth wire 39 4x10.0sq mm + 2x10.0 sq mm earth wire 40 4x16.0 sq mm + 2x16.0 sq mm earth wire 41 Supplying and fixing of following sizes of steel conduit along with the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 42 20 mm dia 43 25 mm dia 44 32 mm dia 45 40 mm dia 46 50 mm dia 47 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 48 6A modular switch 49 16A modular switch 50 6A modular socket 51 16A modular socket 52 TV antenna socket outlet 53 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 54 1 or 2 Module (75mmX75mm) 55 3 Module (100mmX75mm) 56 4 Module (125mmX75mm) 57 6 Module (200mmX75mm) 58 8 Module (125mmX125mm) 59 12 Module (200mmX150mm) 60 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 61 1 or 2 Module 62 3 Module 63 4 Module 64 6 Module 65 8 Module 66 12 Module 67 Supplying & drawing following pair, 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel/PVC conduit as required. 68 2 pair 69 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 70 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 71 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 72 2 + 6 way, Single door 73 2 + 8 way, Single door 74 2 + 12 way, Single door 75 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phaseare required.) 76 6 way (4 + 18), Double door 77 8 way (4 + 24), Double door 78 12 way (4 + 36), Double door 79 S/F Vertical type TP MCB DB 80 Supplying and fixing 5 amps to 32 amps rating, 240 volt, C series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 81 Single Pole 82 Double Pole 83 Supplying and fixing following rating, C series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 84 40 A, DP MCB (10KA) 85 63 A, DP MCB (10KA) 86 40 A, FP MCB (10KA) 87 63 A, FP MCB (10KA) 88 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, Hi immunity type residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 89 25 Amp 90 40 Amp 91 63 Amp 92 Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 93 75 mm wide x 40 mm deep. 94 100 mm wide x 40 mm deep. 95 150 mm wide x 40 mm deep. (with 2 Partition) 96 200 mm wide x 40 mm deep. 97 200 mm wide x 40 mm deep. (with 2 Partition) 98 250 mm wide x 40 mm deep. 99 300 mm wide x 40 mm deep. 100 Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 101 100 mm wide x 50 mm deep. 102 150 mm wide x 50 mm deep. 103 200 mm wide x 50 mm deep. 104 250 mm wide x 50 mm deep. 105 300 mm wide x 50 mm deep. 106 350 mm wide x 50 mm deep. 107 Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor FRLS insulated cable including termination complete as required in existing cable tray. 108 1c x 35 sq.mm FRLS PVC Insulated cu wire including termination etc. for server earthing. 109 1c x 6 sq.mm FRLS PVC Insulated cu wire including termination etc. for UPS DB & HUB Room Rack earthing. 110 Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mmx6mm copper strip), front door with glass as complete as required. 111 Supply & fixing of following size of Stainless Steel Cover Plate with finishing of following size with SS screw erc as complete as required. 112 150 mm x 150 mm x 2.0 mm 113 200 mm x 200 mm x 2.0 mm 114 250 mm x 250 mm x 3.0 mm 115 300 mm x 300 mm x 3.0 mm 116 350 mm x 350 mm x 3.0 mm 117 400 mm x 400 mm x 3.0 mm 118 S.H. -IV EARTHING SYSTEM 119 Providing, Fixing, Testing & Commissioningof following copper strip wire on surface of wall/ trench including insulator with heat shrinkable sleeves etc. as required. 120 32mm x 6mm 121 Providing, Fixing, Testing & Commissioningof following G.I. Strip/ G.I. wire on surface of wall/ trench etc. as required. 122 50mm x 6mm 123 25mm x 6mm 124 8 SWG G.I. Wire 125 (B) S.H. - I MAIN & SUB MAIN CABLES(For Fifth Floor Commercial Court) 126 Supply of following sizes of 1.1KV grade multicore aluminium conductor FRLS insulated and FRLS sheathed armoured cable conforming torelevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant) 127 3.5 crore ,70 sq.mm 128 3.5 core,50 sq.mm. 129 4 core,16 sq.mm. 130 4 core,10 sq.mm. 131 4 core,6 sq.mm. 132 4 core,4 sq.mm. 133 2 core,6 sq.mm. 134 Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required. 135 3½ X 70 sq. mm (38mm) 136 3½ X 50 sq. mm (35mm) 137 4 X 16 sq. mm (28mm) 138 4 X 10 sq. mm (25mm) 139 4 core,6 sq.mm.(25 mm) 140 4 core,4 sq.mm. (25 mm) 141 2 X 6 sq. mm (19mm) 142 Fabricating & installating following sizes of Perforated Type G.I. cable tray including horizontal & vertical bends, reducers, tees, cross members and other accessories as required & duly suspended from the ceiling with G.I.. suspenders etc. as required. 143 100mm x 40mm x 1.6mm 144 150mm x 40mm x 1.6mm 145 300mm x 40mm x 1.6mm 146 Supply, designing, fabrication and installation ofM.S. Angle / channel etc. complete as required. 147 MV CABLE LAYING- 148 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 149 Upto 35 sq. mm (clamped with 1mm thick saddle) 150 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 151 POINTWIRING 152 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 153 Group C 154 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 155 Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 156 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 157 2x2.5sq mm + 1x2.5 sq mm earth wire 158 2x4.0sq mm + 1x4.0 sq mm earth wire 159 2x6.0sq mm + 1x6.0 sq mm earth wire 160 2x10.0sq mm + 1x10.0 sq mm earth wire 161 2x16.0sq mm + 1x16.0 sq mm earth wire 162 4x6.0sq mm + 2x6.0 sq mm earth wire 163 4x10.0sq mm + 2x10.0 sq mm earth wire 164 4x16.0 sq mm + 2x16.0 sq mm earth wire 165 Supplying and fixing of following sizes of steel conduit along with the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 166 20 mm dia 167 25 mm dia 168 32 mm dia 169 40 mm dia 170 50 mm dia 171 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 172 6A modular switch 173 16A modular switch 174 6A modular socket 175 16A modular socket 176 TV antenna socket outlet 177 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 178 1 or 2 Module (75mmX75mm) 179 3 Module (100mmX75mm) 180 4 Module (125mmX75mm) 181 6 Module (200mmX75mm) 182 8 Module (125mmX125mm) 183 12 Module (200mmX150mm) 184 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 185 1 or 2 Module 186 3 Module 187 4 Module 188 6 Module 189 8 Module 190 12 Module 191 Supplying & drawing following pair, 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel/PVC conduit as required. 192 2 pair 193 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 194 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 195 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 196 2 + 6 way, Single door 197 2 + 8 way, Single door 198 2 + 12 way, Single door 199 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phaseare required.) 200 6 way (4 + 18), Double door 201 8 way (4 + 24), Double door 202 12 way (4 + 36), Double door 203 S/F Vertical type TP MCB DB 204 Supplying and fixing 5 amps to 32 amps rating, 240 volt, C series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 205 Single Pole 206 Double Pole 207 Supplying and fixing following rating, C series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 208 40 A, DP MCB (10KA) 209 63 A, DP MCB (10KA) 210 40 A, FP MCB (10KA) 211 63 A, FP MCB (10KA) 212 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, Hi immunity type residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 213 25 Amp 214 40 Amp 215 63 Amp 216 Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 217 75 mm wide x 40 mm deep. 218 100 mm wide x 40 mm deep. 219 150 mm wide x 40 mm deep. (with 2 Partition) 220 200 mm wide x 40 mm deep. 221 200 mm wide x 40 mm deep. (with 2 Partition) 222 250 mm wide x 40 mm deep. 223 300 mm wide x 40 mm deep. 224 Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 225 100 mm wide x 50 mm deep. 226 150 mm wide x 50 mm deep. 227 200 mm wide x 50 mm deep. 228 250 mm wide x 50 mm deep. 229 300 mm wide x 50 mm deep. 230 350 mm wide x 50 mm deep. 231 Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor FRLS insulated cable including termination complete as required in existing cable tray. 232 1c x 35 sq.mm FRLS PVC Insulated cu wire including termination etc. for server earthing. 233 1c x 6 sq.mm FRLS PVC Insulated cu wire including termination etc. for UPS DB & HUB Room Rack earthing. 234 Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mmx6mm copper strip), front door with glass as complete as required. 235 Supply & fixing of following size of Stainless Steel Cover Plate with finishing of following size with SS screw erc as complete as required. 236 150 mm x 150 mm x 2.0 mm 237 200 mm x 200 mm x 2.0 mm 238 250 mm x 250 mm x 3.0 mm 239 300 mm x 300 mm x 3.0 mm 240 350 mm x 350 mm x 3.0 mm 241 400 mm x 400 mm x 3.0 mm 242 S.H. -IV EARTHING SYSTEM 243 Providing, Fixing, Testing & Commissioningof following copper strip wire on surface of wall/ trench including insulator with heat shrinkable sleeves etc. as required. 244 32mm x 6mm 245 Providing, Fixing, Testing & Commissioningof following G.I. Strip/ G.I. wire on surface of wall/ trench etc. as required. 246 50mm x 6mm 247 25mm x 6mm 248 8 SWG G.I. Wire 249 Labour Cess will be paid extra as per applicable 250 GST will be paid extra as per applicable

Key Value

Document Fees
INR 3180 /-
EMD
INR 281000.0 /-
Tender Value
INR 1.40 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail