}

Tender For Supply Of Consumables/Non-Consumables Items, Pondicherry-Puducherry

Boards / Undertakings / PSU has published Tender For Supply Of Consumables/Non-Consumables Items. Submission Date for this Tender is 05-08-2024. Medicine Tenders in Pondicherry Puducherry. Bidders can get complete Tender details and download the document.




Tender Notice

44103941
Tender For Supply Of Consumables/Non-Consumables Items
Open Tender
Indian
Puducherry
Pondicherry
05-08-2024

Tender Details

Supply Of Consumables/Non-Consumables Items Supply Of Consumables/Non-Consumables Items For The Department Of Cssd , Consumables , Surgical Gloves For General Routine Operations / Icu Usage: Size - 6.0:Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface Used For General Routine Operations.Gloves Should Have High Level Of Tactile Sensitivity, Secure Grip,Good Resistant To Tear, Ease Of Donning Andreduction Of Reflective Glare. Packing: Number Of Gloves In A Pack: 2 Nos. (1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent. Dimensions: Size(Number): 6Thickness: 0.20 - 0.24 Mm. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified, Confirming Is 4148: 1989 (2021) / Is 13422: 1992 (2018) Or Equivalent Standards Ce / Usfda Approved. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Surgical Gloves For General Routine Operations / Icu Usage: Size 6.5Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface Used For General Routine Operations.Gloves Should Have High Level Of Tactile Sensitivity, Secure Grip,Good Resistant To Tear, Ease Of Donning Andreduction Of Reflective Glare. Packing: Number Of Gloves In A Pack: 2 Nos. (1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent. Dimensions: Size(Number): 6.5 Thickness: 0.20 - 0.24 Mm. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified, Confirming Is 4148: 1989 (2021) / Is 13422: 1992 (2018) Or Equivalent Standards Ce / Usfda Approved. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Surgical Gloves For General Routine Operations / Icu Usage: Size7. 0 : Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface Used For General Routine Operations.Gloves Should Have High Level Of Tactile Sensitivity, Secure Grip,Good Resistant To Tear, Ease Of Donning Andreduction Of Reflective Glare. Packing: Number Of Gloves In A Pack: 2 Nos. (1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent. Dimensions: Size(Number): 7Thickness: 0.20 - 0.24 Mm. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified, Confirming Is 4148: 1989 (2021) / Is 13422: 1992 (2018) Or Equivalent Standards Ce / Usfda Approved. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Surgical Gloves For General Routine Operations / Icu Usage: Size 7.5 Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface Used For General Routine Operations.Gloves Should Have High Level Of Tactile Sensitivity, Secure Grip,Good Resistant To Tear, Ease Of Donning Andreduction Of Reflective Glare. Packing: Number Of Gloves In A Pack: 2 Nos. (1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent. Dimensions: Size(Number): 7.5 Thickness: 0.20 - 0.24 Mm. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified, Confirming Is 4148: 1989 (2021) / Is 13422: 1992 (2018) Or Equivalent Standards Ce / Usfda Approved. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Surgical Gloves For General Routine Operations / Icu Usage:Size 8.0 : Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface Used For General Routine Operations.Gloves Should Have High Level Of Tactile Sensitivity, Secure Grip,Good Resistant To Tear, Ease Of Donning Andreduction Of Reflective Glare. Packing: Number Of Gloves In A Pack: 2 Nos. (1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent. Dimensions: Size(Number): 8Thickness: 0.20 - 0.24 Mm. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified, Confirming Is 4148: 1989 (2021) / Is 13422: 1992 (2018) Or Equivalent Standards Ce / Usfda Approved. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Surgical Gloves For Speciality Surgeries: Size 6.0:Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface, Tight Beaded Cuff, Used For Speciality Surgeries. Textured Finish: Gloves Should Ensure Secure Grip For Confident Instrument Handling Under Dry Or Damp Conditions And Reduction Of Reflective Glare. Optimized Thickness: Gloves Should Have Ideal Balance Of Tactile Sensitivity And Protection, Shape Of Curved Fingers Thumb Ball, Rounded Finger Tips, To Reduce Hand Fatique Donning Technology: Gloves Should Have Internal Coating To Facilitate Effortless / Easy Donning And Doffing With Either Dry Or Damp Hands. Chemo Tested: Gloves Should Be Tested And Safe To Use With Wide Range Of Drugs. Packing: Number Of Gloves In A Pack: 2 Nos.(1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent / Brown / Green To Reduce Reflective Glare. Dimensions: Size(Number): 6. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified Orastm D3577/D7160 Or En 16523-1/En 374-2 And -4/En 4551-4 Or En Iso 21420:2020/Iso 10282. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility Or Certificates To Be Available In The Oem Website . , Surgical Gloves For Speciality Surgeries: Size6.5:Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface, Tight Beaded Cuff, Used For Speciality Surgeries. Textured Finish: Gloves Should Ensure Secure Grip For Confident Instrument Handling Under Dry Or Damp Conditions And Reduction Of Reflective Glare. Optimized Thickness: Gloves Should Have Ideal Balance Of Tactile Sensitivity And Protection, Shape Of Curved Fingers Thumb Ball, Rounded Finger Tips, To Reduce Hand Fatique Donning Technology: Gloves Should Have Internal Coating To Facilitate Effortless / Easy Donning And Doffing With Either Dry Or Damp Hands. Chemo Tested: Gloves Should Be Tested And Safe To Use With Wide Range Of Drugs. Packing: Number Of Gloves In A Pack: 2 Nos.(1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent / Brown / Green To Reduce Reflective Glare. Dimensions: Size(Number): 6.5. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified Orastm D3577/D7160 Or En 16523-1/En 374-2 And -4/En 4551-4 Or En Iso 21420:2020/Iso 10282. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility Or Certificates To Be Available In The Oem Website . , Surgical Gloves For Speciality Surgeries: Size7.0 : Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface, Tight Beaded Cuff, Used For Speciality Surgeries. Textured Finish: Gloves Should Ensure Secure Grip For Confident Instrument Handling Under Dry Or Damp Conditions And Reduction Of Reflective Glare. Optimized Thickness: Gloves Should Have Ideal Balance Of Tactile Sensitivity And Protection, Shape Of Curved Fingers Thumb Ball, Rounded Finger Tips, To Reduce Hand Fatique Donning Technology: Gloves Should Have Internal Coating To Facilitate Effortless / Easy Donning And Doffing With Either Dry Or Damp Hands. Chemo Tested: Gloves Should Be Tested And Safe To Use With Wide Range Of Drugs. Packing: Number Of Gloves In A Pack: 2 Nos.(1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent / Brown / Green To Reduce Reflective Glare. Dimensions: Size(Number): 7. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified Orastm D3577/D7160 Or En 16523-1/En 374-2 And -4/En 4551-4 Or En Iso 21420:2020/Iso 10282. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility Or Certificates To Be Available In The Oem Website . , Surgical Gloves For Speciality Surgeries: Size 7.5:Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface, Tight Beaded Cuff, Used For Speciality Surgeries. Textured Finish: Gloves Should Ensure Secure Grip For Confident Instrument Handling Under Dry Or Damp Conditions And Reduction Of Reflective Glare. Optimized Thickness: Gloves Should Have Ideal Balance Of Tactile Sensitivity And Protection, Shape Of Curved Fingers Thumb Ball, Rounded Finger Tips, To Reduce Hand Fatique Donning Technology: Gloves Should Have Internal Coating To Facilitate Effortless / Easy Donning And Doffing With Either Dry Or Damp Hands. Chemo Tested: Gloves Should Be Tested And Safe To Use With Wide Range Of Drugs. Packing: Number Of Gloves In A Pack: 2 Nos.(1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent / Brown / Green To Reduce Reflective Glare. Dimensions: Size(Number): 7.5. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified Orastm D3577/D7160 Or En 16523-1/En 374-2 And -4/En 4551-4 Or En Iso 21420:2020/Iso 10282. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility Or Certificates To Be Available In The Oem Website . , Surgical Gloves For Speciality Surgeries: Size 8.0: Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Surgical Gloves With Finish Ofsmooth Inner Surface Andrough Outer Surface, Tight Beaded Cuff, Used For Speciality Surgeries. Textured Finish: Gloves Should Ensure Secure Grip For Confident Instrument Handling Under Dry Or Damp Conditions And Reduction Of Reflective Glare. Optimized Thickness: Gloves Should Have Ideal Balance Of Tactile Sensitivity And Protection, Shape Of Curved Fingers Thumb Ball, Rounded Finger Tips, To Reduce Hand Fatique Donning Technology: Gloves Should Have Internal Coating To Facilitate Effortless / Easy Donning And Doffing With Either Dry Or Damp Hands. Chemo Tested: Gloves Should Be Tested And Safe To Use With Wide Range Of Drugs. Packing: Number Of Gloves In A Pack: 2 Nos.(1 Pair), Outer Packing Should Be Poly Pouch Or Lacquer Coated Peel Down Paper Or Blister Poly Peel. Inner Packing With Medical Grade Paper. Packed To Maintain Sterility During Shipping & Storage And Permit Opening Without Contamination Of The Gloves. Colour: Translucent / Brown / Green To Reduce Reflective Glare. Dimensions: Size(Number): 8. Self Life: 5 Years. The Product Should Have At Least 2/3 Rd Of The Total Shelf Life Available At The Time Of Supply. Standards: Bis Certified Orastm D3577/D7160 Or En 16523-1/En 374-2 And -4/En 4551-4 Or En Iso 21420:2020/Iso 10282. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility Or Certificates To Be Available In The Oem Website . , Sterile Examination Glovesspecification:Size: Small (5-6) 1) Type Ofglove : Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Gloves For Medical Examination . Gloves Should Not Be Sticky Andgood Resistant To Tear As Per Standard2) Size: Small(5-6), 3)Packing For Gloves: Individual Packingforsingle Sterile Glove Within The Medical Gradepaperwith Outer Cover. Number Of Glove In A Pack: Single4) Certification: Bis Certified Confirming With Is:15354,Isi Marked. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Sterile Examination Glovesspecification: Size: Medium (7-8)1) Type Ofglove : Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Gloves For Medical Examination . Gloves Should Not Be Sticky Andgood Resistant To Tear As Per Standard2) Size:Medium(7-8) 3)Packing For Gloves: Individual Packingforsingle Sterile Glove Within The Medical Gradepaperwith Outer Cover. Number Of Glove In A Pack: Single4) Certification: Bis Certified Confirming With Is:15354,Isi Marked. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Sterile Examination Glovesspecification: Size: Large (8.5- 9.5) 1) Type Ofglove : Single Use,Sterile, Disposable, Polimer Coated Powder Free, Naturallatex Gloves For Medical Examination . Gloves Should Not Be Sticky Andgood Resistant To Tear As Per Standard2) Size:Large(8.5-9.5) 3)Packing For Gloves: Individual Packingforsingle Sterile Glove Within The Medical Gradepaperwith Outer Cover. Number Of Glove In A Pack: Single4) Certification: Bis Certified Confirming With Is:15354,Isi Marked. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Unsterile Examination Gloves Specifications: Size: Small (5-6)1)Type Ofglove : Single Use,Unsterile, Disposable, Polimer Coated Powder Free, Naturallatex Gloves For Medical Examination . Gloves Should Have Good Resistant To Tear As Per Standard Andnot Tobe Sticky With Each Other.2)Size: Small(5-6)3) Packing: Multi Units In One Packet: 100 Gloves. Certification: Bis Certified Confirming With Is:15354,Isi Marked. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Unsterile Examination Gloves Specifications: Size: Medium (7-8) 1)Type Ofglove : Single Use,Unsterile, Disposable, Polimer Coated Powder Free, Naturallatex Gloves For Medical Examination . Gloves Should Have Good Resistant To Tear As Per Standard Andnot Tobe Sticky With Each Other.2)Size: Medium(7- 8)3) Packing: Multi Units In One Packet: 100 Gloves. Certification: Bis Certified Confirming With Is:15354,Isi Marked. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Unsterile Examination Gloves Specifications:Size: Large (8.5- 9.5)1)Type Ofglove : Single Use,Unsterile, Disposable, Polimer Coated Powder Free, Naturallatex Gloves For Medical Examination . Gloves Should Have Good Resistant To Tear As Per Standard Andnot Tobe Sticky With Each Other.2)Size: Large(8.5- 9.5)3) Packing: Multi Units In One Packet: 100 Gloves. Certification: Bis Certified Confirming With Is:15354,Isi Marked. Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Test Reports / Proof Of Sterility From Cdsco / Central Govt./Nabl Acredited Lab To Prove Conformity To The Specifications. , Nitrile Gloves For Medical Examination: Size: Small (5- 6)Type Of Gloves: Single Use, Unsterile, Latex Free, Odor Free, Beaded Cuff, Textured Fingers, Consistent Grip And High Elasticity, Powder-Free Nitrile Gloves For Medical Examination.Gloves Should Have Good Resistant To Tear As Per Standard And Not To Be Sticky With Each Other. Pack Size: 100 Units.Colour: Blue. Medical Level Standard: Astm 6319.Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates, Test Reports From Cdsco / Central Govt/Nabl Acredited Lab To Prove Conformity To The Specifications. , Nitrile Gloves For Medical Examination: Size: Medium(7- 8)Type Of Gloves: Single Use, Unsterile, Latex Free, Odor Free, Beaded Cuff, Textured Fingers, Consistent Grip And High Elasticity, Powder-Free Nitrile Gloves For Medical Examination.Gloves Should Have Good Resistant To Tear As Per Standard And Not To Be Sticky With Each Other. Pack Size: 100 Units.Colour: Blue. Medical Level Standard: Astm 6319.Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates, Test Reports From Cdsco / Central Govt/Nabl Acredited Lab To Prove Conformity To The Specifications. , Nitrile Gloves For Medical Examination: Size: Large (8.5- 9.5)Type Of Gloves: Single Use, Unsterile, Latex Free, Odor Free, Beaded Cuff, Textured Fingers, Consistent Grip And High Elasticity, Powder-Free Nitrile Gloves For Medical Examination.Gloves Should Have Good Resistant To Tear As Per Standard And Not To Be Sticky With Each Other. Pack Size: 100 Units.Colour: Blue. Medical Level Standard: Astm 6319.Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates, Test Reports From Cdsco / Central Govt/Nabl Acredited Lab To Prove Conformity To The Specifications. , Non-Pvc Glovespecifications :- Disposable Non-Pvc Hdpe Gloves Of 45 G Thickness. Transparent, Universal Fitting Size, Soft & Flexible, Latex Free, Powder Free. , Reusable Nitrile Chemical Gloves For Cleaning Purpose: Size: Small (Palm With: 7Cm) Reusable Nitrile Gloves Made From Acryonitrile Butadiene Rubber Which Is Mechanical Resistant (En 388) To Puncture, Tear, Blade Cut, Abrasion And Penetration Resistant (En 374- Part-2 & 3) Against Chemicals & Micro Organisms. Grip: Gloves Should Have Good Gripping Pattern Palm In Both Wet And Dry Conditions. Color: Any.No Of Gloves In A Pack : 2 (One Pair) , Reusable Nitrile Chemical Gloves For Cleaning Purpose: Size: Medium (Palm With: 8Cm) Reusable Nitrile Gloves Made From Acryonitrile Butadiene Rubber Which Is Mechanical Resistant (En 388) To Puncture, Tear, Blade Cut, Abrasion And Penetration Resistant (En 374- Part-2 & 3) Against Chemicals & Micro Organisms. Grip: Gloves Should Have Good Gripping Pattern Palm In Both Wet And Dry Conditions. Color: Any.No Of Gloves In A Pack : 2 (One Pair) , Reusable Nitrile Chemical Gloves For Cleaning Purpose: Size: Large(Palm With: 9Cm) Reusable Nitrile Gloves Made From Acryonitrile Butadiene Rubber Which Is Mechanical Resistant (En 388) To Puncture, Tear, Blade Cut, Abrasion And Penetration Resistant (En 374- Part-2 & 3) Against Chemicals & Micro Organisms. Grip: Gloves Should Have Good Gripping Pattern Palm In Both Wet And Dry Conditions. Color: Any.No Of Gloves In A Pack : 2 (One Pair) , Sterile Disposable Syringe For Single Use Without Needle1 Ml: Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation With Permanent Marking, Easy Readability, Safe Plunger Backstop, Smooth Finishing Of Barrel & Plunger.Syringe Capacity: 1Ml. Graduation:Unit Scale U-40 Or Both U-40 And Ml Printed In Same Syringe.Syringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity.Standards: Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3. Barrel Nozzle:Luer Slip Type. Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards) Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Syringe For Single Use Without Needle 2 Ml: Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation In Ml, Scale Interval 0.1Ml Line Increment According To Iso Standard With Permanent Marking, Easy Readability, Safe Plunger Backstop, Smooth Finishing Of Barrel & Plunger.Syringe Capacity: 2 Ml. Syringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity.Standards: Bis Certified, Should Be Comply Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3.Barrel Nozzle:Luer Slip Type. Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards) Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Syringe For Single Use Without Needle 5 Ml:Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation In Ml Scale Interval 0.2Ml Line Increment According To Iso Standard With Permanent Marking, Easy Readability, Safe Plunger Backstop, Smooth Finishing Of Barrel & Plunger.Syringe Capacity:5 Ml Syringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity.Standards: Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3. Barrel Nozzle:Luer Slip Type. Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards) Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Syringe For Single Use Without Needle 10 Ml: Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation In Ml Scale Interval 0.2Ml Line Increment According To Iso Standard With Permanent Marking, Easy Readability, Safe Plunger Backstop, Smooth Finishing Of Barrel & Plunger.Syringe Capacity: 10 Mlsyringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity.Standards: Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3. Barrel Nozzle:Luer Slip Type.Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards)Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Syringe For Single Use Without Needle 20 Ml:Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation In Ml Scale Interval 1Ml Line Increment According To Iso Standard With Permanent Marking, Easy Readability, Safe Plunger Backstop, Smooth Finishing Of Barrel & Plunger.Syringe Capacity: 20 Ml. Syringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity.Standards: Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3. Barrel Nozzle:Luer Slip Type. Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards) Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Syringe For Single Use Without Needle 50 Ml: Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation In Ml Scale Interval 1Ml Line Increment According To Iso Standard With Permanent Marking, Easy Readability, Safe Plunger Backstop, Smooth Finishing Of Barrel & Plunger.Syringe Capacity: 50 Ml. Syringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity.Standards: Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3. Barrel Nozzle:Luer Slip Type. Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards) Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Insulin Syringe: Syringe Unit Scale (Units): U-40 Insulin Syringe Type: As Per Iso 8537:2016 Or Its Equivalent Indian Standards.Syringe With Needle And Packaged In A Unit Packaging.Syringe Barrel: Sufficiently Clear To Enable Dosages To Be Read And For Air Bubbles To Be Seen Without Difficulty. Barrel Length With A Usable Capacity Of Either 10 % More Than The Nominal Capacity.Syringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps). The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Of Insulin Preparations , Actively Disabling Syringes Without Needle Specifications : - Capacity =5 Ml Sterile, Disposable And Without Needle. Actively Disabling - Rup Syringe With Reuse Prevention Feature. 2 Part Syringe. Actively Disabling Reuse Prevention Feature, Permanently Disable By User After Completion Of Intended Use Even After Multiple Plunger Movements To Prevent Subsequent Reuse Of The Syringe, Equivalent To Iso 7864, Type 2-B. , Actively Disabling Syringes Without Needle Specifications : - Capacity =10 Ml Sterile, Disposable And Without Needle. Actively Disabling - Rup Syringe With Reuse Prevention Feature.2 Part Syringe. Actively Disabling Reuse Prevention Feature, Permanently Disable By User After Completion Of Intended Use Even After Multiple Plunger Movements To Prevent Subsequent Reuse Of The Syringe, Equivalent To Iso 7864, Type 2-B. , Sterile Disposable Syringe For Single Use Without Needle 20 Ml Luer Lock Type: Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation In Ml With Permanent Marking, Easy Readability, Safe Plunger Backstop. Syringe Capacity: 20 Mlsyringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity. Standards: Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3. Barrel Nozzle:Luer Lock Type.Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards) Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Syringe For Single Use Without Needle 50 Ml Luer Lock Type: Specifications: Syringes Should Be With Clear Syringe Barrel, Precise Graduation In Ml With Permanent Marking, Easy Readability, Safe Plunger Backstop.Syringe Capacity: 50 Ml Syringe Material: Medical Grade Plastic (Polyethylene (Pe)/ Polypropylene (Pp)/ Polystyrene (Ps).The Materials Used For Fabrication Of Syringes(Including Lubricant) And Packaging Should Be Non Toxic, Do Not Adversely Affect The Efficacy, Safety And Acceptability.Syringe Barrel: Sufficiently Transparent To Allow Easy Measurement Of The Volume Contained In The Syringe And Detection Of Air Bubbles. Length With A Maximum Usable Capacity Of At Least 10% More Than The Nominal Capacity.Standards: Indian Standard Is 10258 -2002 Latest, Equivalent To Iso 7886 Part 3. Barrel Nozzle:Luer Lock Type. Sterility & Product And Packaging: Sterile,Ethylene Oxide Sterilisation And Compiles To Bs En 550:1994-Iso 11135-1:2007 Or Its Equivalent Indian Standards) Primary Packaging: Each Syringe Packed In An Individual Sterilized Peel-Pack / Blister Pack / Ribbon Pack.Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Abg Syringes 1 Ml Capacity:A Balanced Heparin Containing Abgsyringe With Needle For Blood Gas Analysis. Complete Data Sheet To Be Provioded , Sterile Disposable Hypodermic Needles Specifications: 16G X 1.5Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized.Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 18G X 1.5Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized. Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 20G X 1.5Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized. Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 21G X 1.5Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized. Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptabilitycertificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 22G X 1.5Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized. Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 23G X 1.0Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized. Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 24G X 1.0Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized. Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling:Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 26G X 0.5Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized. Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Sterile Disposable Hypodermic Needles Specifications: 31G X 5/16 (8 Mm) Needle Material: Stainless Steel Tubing Conform To Is 10654:2002 Latest For Sterile Hypodermic Needles, Quivalent To Iso 9626 And Needle Point In Accordance With Iso 7864. Should Be Packed Without Any Risk Of Breach In Sterility. Eto/Gamma Sterilized.Needle Measurements: External Diameter Expressed In Gauge And Inches.Needle Protective Cap: Medical Grade Plastic.Dead Space: Should Beminimum To Reduce Waste.Sterile: By Ethylene Oxide And Compiles To Bs En 550:1994-Iso 11135-1:2007.Packaging And Labelling: Primary Packaging: Each Needle Packed In An Individual Sterilized Peel-Pack Made Of Paper And/Or Plastic.The Materials Used For Fabrication Ofneedlesand Packaging Do Not Adversely Affect The Efficacy, Safety And Acceptability Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility. Or Certificates To Be Available In The Oem Website . , Infusion (Iv) Set, Non-Vented: Sterile, Disposable, Single Use, Gravity Feed, Non-Vented Infusion Set Confirming To Is: 12655 (Part -4) Latest. Iv Set Should Be Non-Toxic, Pyrogen Free, Non-Kinking Quality.Iv Set Should Have Sturdy Spike With Protective Cap, Drip Chamber Should Have Fluid Filter, Sturdy Roller Clamp, Non-Kinking, Non-Toxic Tubing, Stepwise Injection Port, Luer Slip Connector With 21 G Needle. Infusion Should Be Macro Drip (20 Drops = 1 Ml ± 0.1Ml) Pack Without Any Risk Of Breach In Sterility, Eto/ Gamma Sterilized. Outer Cover Should Have Option Eye Cut/Tear Mark/Peel-Pack For Easy Opening.Iso Or Isi Certified Or Its Equivalent Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility Or Certificates/Documents To Be Available In The Oem Website . , Infusion (Iv) Set, Vented: Sterile, Disposable, Single Use, Gravity Feed, Vented Infusion Set Confirming To Is: 12655 (Part -4) Latest. Iv Set Should Be Non-Toxic, Pyrogen Free, Non-Kinking Quality.Iv Set Should Have Sturdy Spike With Protective Cap, Drip Chamber Should Have Fluid Filter And Non-Leaking Air Vent With Provision Of Closure Of Airvent, Sturdy Roller Clamp, Non-Kinking, Non-Toxic Tubing, Stepwise Injection Port, Luer Slip Connector With 21 G Needle. Infusion Should Be Macro Drip (20 Drops = 1 Ml ± 0.1Ml) Pack Without Any Risk Of Breach In Sterility, Eto/ Gamma Sterilized. Outer Cover Should Have Option Eye Cut/Tear Mark/Peel-Pack For Easy Opening.Iso Or Isi Certified Or Its Equivalent Certificates: Oem Should Produce Data Sheet, Certificate Of Standards, Valid Licenses, Manufacturing Units Certificates (Iso 13485), Marketing Approval / Test Reports / Proof Of Sterility Or Certificates/Documents To Be Available In The Oem Website . , 3 Ply Surgical Masktie Type:Specifications:1) Iso Certified: Yes 2) Fabric Material: Non-Woven Fabric With Middle Polyfibre Layer 3) Gsm Of The Fabric(G/M2): 60-70 4) Pleated Construction Of Mask: To Provide Adjustable And Leakproof Fitting 5) No. Of Layers Of Plies Of Fabric: 3 Layers 6) Bacterial Filtration Efficiency (Bfe%):>=99 7) Splash Resistant: Yes 8) Breathing Resistance (Mm Of H2o/Cm2): <=5(Splash Resistant) 9) Securing Type: Tie Type 10) Adjustable Flexible Nose Clip: With 11) Colour: Any 12) Length : 17 - 18Cm 13) Width: 9 - 10Cm14) Submission Of Test Report To The Buyer On Demand From Nabl/Ilac Accredited Or Central Govt. Lab To Prove Conformity Of Products To The Specification: Yes 15) Certification: Isi , 3 Ply Surgical Maskearloop Type:Specifications:1) Iso Certified: Yes 2) Fabric Material: Non-Woven Fabric With Middle Polyfibre Layer 3) Gsm Of The Fabric(G/M2): 60-70 4) Pleated Construction Of Mask: To Provide Adjustable And Leakproof Fitting 5) No. Of Layers Of Plies Of Fabric: 3 Layers 6) Bacterial Filtration Efficiency (Bfe%):>=99 7) Splash Resistant: Yes 8) Breathing Resistance (Mm Of H2o/Cm2): <=5(Splash Resistant) 9) Securing Type: Earloop Type 10) Adjustable Flexible Nose Clip: With 11) Colour: Any 12) Length : 17 - 18Cm 13) Width: 9 - 10Cm14) Submission Of Test Report To The Buyer On Demand From Nabl/Ilac Accredited Or Central Govt. Lab To Prove Conformity Of Products To The Specification: Yes 15) Certification: Isi , Doctors Cap (Bouffant Type) Specifications:- 1) Size: 18-21 Inch 2) Type Of Material: Non-Woven Breathable 3) Design: Bouffant Type 4) Composition Of Nonwoven Material: Spun-Bond Non-Woven 5) Gsm Of Cap Material: 20Gm/Sq.Mtrs.6) Well Fitted With Double Elastic Or String: Yes7) Properly Ultrasonically Sealed For Uniformity: Yes8) Colour: Any9) Bacterial Filteration: Yes10) Air Permeable: Yes11) Certification: Iso Certified12) Submission Of Test Report To The Buyer From Nabl/Ilac Accredited Or Central Govt. Lab To Prove Conformity Of Products To The Specification On Demand To The Buyer: Yes , Surgeons Cap With Sweat Band : Specifications:- 1) Size: 18-21 Inch 2) Type Of Material: Non-Woven Breathable 3) Composition Of Nonwoven Material: Spun-Bond Non-Woven 4) Well Fitted With Double Elastic Or String: Yes5) Properly Ultrasonically Sealed For Uniformity: Yes6) Colour: Any7) Bacterial Filteration: Yes8) Air Permeable: Yes , Sterile Medical Gownspecifications:- 1)Gown Type: Icu Gown2) Colour: Medical Blue3) Disposable: Yes4) Breathable: Yes5) Antistatic Properties: Yes6) Impervious To Fluids: Yes7) Reinforced: No8) Sterilized: Yes9) Method Of Sterilization: Eto10) Gown Width: 70-80Cm11) Gown Length: 125-150Cm12) Adjustable Neck Ties : Yes.13) No. Of Belts To Tie: 2 Pairs.14) Material Used For Gown: Non-Woven, Spun Bond15) Gsm Of Non-Woven Fabric: 40 G/M216) Alcohol Repellent Material: Yes17) Sleve Type: Full Sleeve18) Cuff End: With Knitted Cuffat Least 10Cm Width19) Wrap Around Type: Yes20) Type Of Packing: Sterile Pack, Pouch Must Be Peel Off Made Of Medical Grade Paper21) Aami Protection Level: Level Iii22) Certification : Iso Certified23) Submission Of Test Report Clearly Specifying The Nomenclature Of Fabric, Method Of Sterilization And Aami Protection Level In Addition To Other Parameter To The Buyer On Form 39 Or From Nabl/Ilac Accredited Or Central Govt. Lab To Prove Conformity Certificte To Be Furnished To Buyer At The Time Of Supply: Yes , Unsterilemedical Gown Specifications:- 1)Gown Type: Ward Gown2) Colour: Medical Blue3) Disposable: Yes4) Breathable: Yes5) Antistatic Properties: Yes6) Impervious To Fluids: Yes7) Reinforced: No8) Sterilized: No10) Gown Width: 70-80Cm11) Gown Length: 125-150Cm12) Adjustable Neck Ties : Yes.13) No. Of Belts To Tie: 2 Pairs. 15) Material Used For Gown: Non-Woven, Spun Bond 16) Gsm Of Non-Woven Fabric: 40 G/M217) Alcohol Repellent Material: Yes 18) Sleve Type: Full Sleeve19) Cuff End: With Knitted Cuffat Least 10Cm Width20) Wrap Around Type: Yes. , Surgeon Gown For Hiv Protection Specifications:-1) Gown Type: Surgeon Gown For Hiv Protection2) Colour: Medical Blue / Green3) Disposable: Yes4) Breathable: Yes5) Antistatic Properties: Yes6) Impervious To Fluids: Yes7) Reinforced: Yes8) Sterilized: Yes9) Method Of Sterilization: Eto10) Gown Width: 70-80Cm11) Gown Length: 125-150Cm . 12) No. Of Belts To Tie: 2 Pairs With Paper Clip13) Material Used For Gown: Non Woven Sms14) Composition Of Reinforced Material : Sms+Poly Coated To Be Smooth Inner Surface 15) Reincorced Critical Zones (Front And Sleeve Up To Elbows) To Provide 100% Protection Against Any Amount Of Fluid: Yes16) Gsm Of Non Woven Fabric: 68G/M2 And Above17) Closing At Neck: Hook And Loop / Velcro Fastener With Piping Of Non Woven Material Stitched To Raw Edges Of Neck Opening Extending At Both Ends For Tying18) Pair Of Disposable Absorbent Hand Wipes: Yes19) Sleeve Type:Raglan Sleeve, Full Sleeve20) Cuff End: With Knitted Cuff Of At Least 10Cm Width21) Wrap Around Type: Yes22) Type Of Packing : Sterile Pack, Must Be Double Packed With Outer Pouch Must Be Peel Off Made Of Medical Gade Paper23) Type Wrapping: Set In Sleeve24) Aami Protection Level: Level Iv25) Certification: Iso 13485:201626) Submission Of Test Report Clearly Specifying The Nomenclature Of Fabric, Method Of Sterilization An Aami Protection Level In Addition To Other Parameter To The Buyer On Form 39 Or From Nabl/Ilac Accredited Or Central Govt. Lab To Prove Conformity Of Products To The Specification : Yes 27) Product Conformity Certificate To Be Furnished To Buyer At The Time Of Supply: Yes , Sms Sterilization Wrapping Paper Sheet (Blue/Green), Size: 100 X 100 Cms Specificaitons:Non-Woven, Bacterial Barrier, Single Use, Light Weight, Wet Penetration Resistant.Lowering The Risk Of Puncturing Or Tearing During Wrapping, Transport. Comply With En 868 – 2.Comply With The Essential Requirement 93/42/Eec Directive And Should Be Ce Marked Or Equivalent. Can Be Sterilized In Steam, Eo, Radiation, Formaldehyde And Vh2 O2 . , Sms Sterilization Wrapping Paper Sheet (Blue/Green), Size: 150 X 150 Cms Specificaitons:Non-Woven, Bacterial Barrier, Single Use, Light Weight, Wet Penetration Resistant.Lowering The Risk Of Puncturing Or Tearing During Wrapping, Transport. Comply With En 868 – 2.Comply With The Essential Requirement 93/42/Eec Directive And Should Be Ce Marked Or Equivalent. Can Be Sterilized In Steam, Eo, Radiation, Formaldehyde And Vh2 O2 . , Disposable Patient Leggings Specifications:-Knee Length Size, Polycoated, Laminated, Non-Woven With Tiable Hem, Impervious, Stretchable , Bootleg Leggingsspecifications:-1) Colour: Any2) Skid Resistance: Yes3) Dust Proof: Yes 4) Well Stitched In Universal Regular Size: Yes5) Should Cover The Knee: Yes.Length Should Be Above Knee Level.6) Hard Elasticized For Better Grip And Easy Wear: Yes.Should Provide One Pair Of Ties Additionally.7) Disposable: Yes8) Sterile: No9) Packing: Pair Individually Packed10) Shoe Size For Which Item Is Suitable: 10,11) Clear Indication Of Size On Disposable Shoe Cover: Yes12) Material (Non-Toxic, Medical Grade): Non-Woven Thick Fabric. Impervious To Fluids:Yes 13) Composition Of Non-Woven Material: Spun Bond + Non Woven14) Gsm Of Non Woven Material: 40 G/Sq.Mtrs16) Submission Of Test Report To The Buyer On Demand From Nabl/Ilac Accredited Or Central Govt. Lab To Prove Conformity Of Products To The Specification On Demand To The Buyer: Yes , Medical Staffapron Specifications:- 1)Single Use , Sterile,Disposablemedical Staff Apron With Proper Neck And Arm Hole Cutting With Straps With Good Resistance To Tear 2) Material Of Apron: Medical Grade Pe 3) Gsm Of Apron Material: > 40 Gms Per Sq.Mtrs4) Thickness: 50 Micron And Above5) Width Of Apron :65- 75 Cms6) Length Of Apron: 120 - 140 Cms7)Colour: Blue / Green .8)Sterile: Yes9) Packing: Individually Packed In Sterile Manner. Submission Of Test Report To The Buyer On Form 39 Or Nabl/Ilac Accredited Or Central Govt. Lab To Prove Conformity Of Products To The Specification On Demand: Yes , Surgical Drapes (Ot Sheet) Specifications:Sterile Disposable Surgical Drapes (Ot Sheet), Non-Woven Material - 100 X 100 Cm With Opening Of 14 X 18 Cm In The Centre With Adhesive Borders. , Microporus Surgical Paper Tape Adhisive Type : Size:- 2.5 Cm X 9 M, Air Permeable, Hypo Allergic With Good Skin Adhision. , Disposable Umbilical Cord Clamp Specifications: Single Use Packed Sterile, Eto Sterilized. Polyoxymethylene Copolymer/Plastic Material Interlocking Teeth For Security Lock With A Click Reopening Or Slipping When Clamped Smooth Edges 5-6 Cm Long, Width 1-1.5 Cm When Closed , Self Adhesive Sterilization Indicator Tapes For Steam Sterilizer: Material Of Tape: Crepe / Semi Crepeed Paper. Tape Length: 90 Meters. Tape Width: 18 Mm. Shelf Life: 2 Years. Colour Of Tape Before Steriliation : White.Change Of The Integrated Chemical Indicator On The Tape By Its Displayof Diagonal Stripes: Yesafter The Sterilization Process Is Complete, The Tape Can Easily Be Removed With No Adhesive Residue:Yes. , Wrapper For Eto Sterilization :Size : 7.5Cm X 200 Mtr. Medical Grade Sheet Should Be Made Ofhigh Density Polyethylene(Hdpe) Covers For Eto Sterilization. Wrapper Shouldallows For An Effective Sterilant Concentration To Be Achieved With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Both Eo And Steam Indicators Should Be Printed On The Sides. Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light. Should Comply To Standards En Iso 11140-1 , En Iso 868-3,5 And 6. Paper And Plastic As Per En Iso Standards. Leakage Test Method? Astmf-1929-98. Bioburden En Iso 11607. A Medical Grade 60Gsm Paper Confirming En 868-3. Brochure To Be Provided. , Wrapper For Eto Sterilization :Size : 15Cm X 200 Mtr. Medical Grade Sheet Should Be Made Ofhigh Density Polyethylene(Hdpe) Covers For Eto Sterilization. Wrapper Shouldallows For An Effective Sterilant Concentration To Be Achieved With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Both Eo And Steam Indicators Should Be Printed On The Sides. Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light. Should Comply To Standards En Iso 11140-1 , En Iso 868-3,5 And 6. Paper And Plastic As Per En Iso Standards. Leakage Test Method? Astmf-1929-98. Bioburden En Iso 11607. A Medical Grade 60Gsm Paper Confirming En 868-3. Brochure To Be Provided. , Wrapper For Eto Sterilization :Size: 20Cm X 200 Mtr.Medical Grade Sheet Should Be Made Ofhigh Density Polyethylene(Hdpe) Covers For Eto Sterilization. Wrapper Shouldallows For An Effective Sterilant Concentration To Be Achieved With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Both Eo And Steam Indicators Should Be Printed On The Sides. Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light. Should Comply To Standards En Iso 11140-1 , En Iso 868-3,5 And 6. Paper And Plastic As Per En Iso Standards. Leakage Test Method? Astmf-1929-98. Bioburden En Iso 11607. A Medical Grade 60Gsm Paper Confirming En 868-3. Brochure To Be Provided. , Wrapper For Eto Sterilization :Size : 30Cm X 200 Mtr. Medical Grade Sheet Should Be Made Ofhigh Density Polyethylene(Hdpe) Covers For Eto Sterilization. Wrapper Shouldallows For An Effective Sterilant Concentration To Be Achieved With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Both Eo And Steam Indicators Should Be Printed On The Sides. Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light. Should Comply To Standards En Iso 11140-1 , En Iso 868-3,5 And 6. Paper And Plastic As Per En Iso Standards. Leakage Test Method? Astmf-1929-98. Bioburden En Iso 11607. A Medical Grade 60Gsm Paper Confirming En 868-3. Brochure To Be Provided. , Wrapper For Plasma Sterilization (Low Temperature Hydrogen Peroxide Plasma Sterilizer):Size : 3 X 70 Mtr.Medical Grade Sheet, Should Be Made Of High Density Polyethylene (Hdpe) And Allows For An Effective Sterilant Concentration To Be Achieved In Low Temperature Hydrogen Peroxide Gas Sterilization To Sterilization Of Heat Liable Devices. Wrapper Should Be With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light.Comply With En 868-5 And Iso 11607. Free From Lead And Heavy Metals. Brochure To Be Provided. , Wrapper For Plasma Sterilization (Low Temperature Hydrogen Peroxide Plasma Sterilizer):Size : 6 X 70 Mtr.Medical Grade Sheet, Should Be Made Of High Density Polyethylene (Hdpe) And Allows For An Effective Sterilant Concentration To Be Achieved In Low Temperature Hydrogen Peroxide Gas Sterilization To Sterilization Of Heat Liable Devices. Wrapper Should Be With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light.Comply With En 868-5 And Iso 11607. Free From Lead And Heavy Metals. Brochure To Be Provided. , Wrapper For Plasma Sterilization (Low Temperature Hydrogen Peroxide Plasma Sterilizer) Size : 10 X70 Mtr.Medical Grade Sheet, Should Be Made Of High Density Polyethylene (Hdpe) And Allows For An Effective Sterilant Concentration To Be Achieved In Low Temperature Hydrogen Peroxide Gas Sterilization To Sterilization Of Heat Liable Devices. Wrapper Should Be With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light.Comply With En 868-5 And Iso 11607. Free From Lead And Heavy Metals. Brochure To Be Provided. , Wrapper For Plasma Sterilization (Low Temperature Hydrogen Peroxide Plasma Sterilizer): Size : 20 X 70 Mtr.Medical Grade Sheet, Should Be Made Of High Density Polyethylene (Hdpe) And Allows For An Effective Sterilant Concentration To Be Achieved In Low Temperature Hydrogen Peroxide Gas Sterilization To Sterilization Of Heat Liable Devices. Wrapper Should Be With Inbuilt Indicator With Resistance To Microbial Penetration, Good Tear Strength, Puncture Resistance And Clean Peel. Inbuilt Indicator: Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light.Comply With En 868-5 And Iso 11607. Free From Lead And Heavy Metals. Brochure To Be Provided. , Eto Cartridges : Cartridge Containing 200Gmof 100% Ethylene Oxide Gas, For Use In Ethylene Oxide Sterilizer (Capacity : 452 Litres). Iso Certified.Brochure To Be Provided. , Rust Removing Soak Solution:Non Toxic, Biodegradable, Water Soluble, Non Corrosive, Non Flammable. Capacity 1 Litre , Rapid Multi Enzyme Cleaner For Manual Washing, 1 Litre Capacity : • Multiple Enzymatic Concentrate Solution With Lipases, Cellulases, Proteases And Amylases • Must Act Against All Possible Body Secretions, Compatible To All Instruments • Fast Acting Within 2- 10 Minutes, Allow Safe Disposable Via The Drain After Use • Leaves No Residue After Wash, Non Corrosive, Nonpungent Odour, Stable Formulation With Near Neutral Ph • Compliance To Iso 13485 , Ultra Rapid Multi Enzyme Cleaner For Automatic And Washing Disinfectors, 1 Litre Capacity: • Multiple Enzymatic Concentrate Solution With Lipases, Cellulases, Proteases And Amylases • Film Based Polymer Technology With Controlled Enzyme Release • Must Act Against All Possible Body Secretions, Compatible To All Instruments • Fast Acting Within 2- 10 Minutes, Allow Safe Disposable Via The Drain After Use • Leaves No Residue After Wash, Non Corrosive, Nonpungent Odour, Stable Formulation With Near Neutral Ph • Should Have Scale Inhibition Properties • Should Help Retain Shine Of The Instrument • Should Be Usable For Manual, Ultra Sonic And Automatic Cleaning Systems • Compliance To Iso 13485 , Instrument Cleaning Brushesspecifications: Tooth Brush Style, Plastic Handle , 7-10 Inches Long, Polypropylene Bristles, Single Ended, Three Rows , General Instrument Cleaning Brushes Specifications: Around 7-10 Inches Long, Stainless Steel Brushes , Bowie-Dick Steam Process Indicatorspecifications:- Disposable Single Use Pack, Lead And Heavy Metal Free, Ability To Preserve Indicator Sheet For Permanent Record. Stable Colour, Colour Change Is Not Reversible, Indicator Ink Should Not Fade In Storage Or Under Fluourescent Light. Comparative Images For Various Results And Conclusions Should Be Provided In The Pack.Add Each Pack To Have Lot Numbers And Expiry Date And A Uniform Contrast Colour Change.Brochure To Be Provided , Biological Indicator For Steam Sterilizationspecifications:-Self Contained Geobacillus Stearothermophilus - Iso 11138:2017 Parts 1 And 3, Iso 11138-7:2019(En) And European Standard Certified Biological Test Pack With Auto Readers For Steam Sterilizer, Smart Read,Stable Colour, Colour Change Should Not To Bereversible, Indicator Ink Should Not Fade In Storage Or Under Fluourescent Light. Spore Population In The Indicator: More Than 105 Cfu . Time Taken For Biological Indicator Result: Rapid Read Out ( Within 30 Min Preferably). Readout Technology: Initially By Fluorescence Detectionand Later By Ph Colour Change. Biological Indicator Ampule Should Be Integrated With Type 5 Chemical Indicators Additionally. Shelf Life: 2 Years. Quality Certification Report Regarding Spore Population,Z Value,D Value, To Be Provided. Brochure For The Bi And Incubator To Be Provided Or Should Be Available In The Website. Compatible Incubator Should Be Provided Free Of Cost , Biological Indicator For Eto Sterilization Specifications: Self-Contained Biological Indicator (Bi) That Consists Of A Bacillus Atrophaeus, Iso 11138-1:2017 And Iso 11138-2:2017 Standards For Eto Sterilizer.Rapid Read Out , Smart Read,Stable Colour, Colour Change Should Not To Bereversible, Indicator Ink Should Not Fade In Storage Or Under Fluourescent Light. Shelf Life: 2 Years.Time Taken For Biological Indicator Result: Rapid Read Out( Within 4 Hours Preferably). Readout Technology: Initially By Fluorescence Detectionand Later By Ph Colour Change. Spore Population In The Indicator: More Than 106Cfu . Readout Technology: Initially By Fluorescence Detectionlater By Ph Colour Change. Biological Indicator Ampule Should Be Integrated With Type 4 / Type 5 Chemical Indicators Additionally.Quality Certification Report Regarding Spore Population,Z Value,D Value, To Be Provided. Brochure For The Bi And Incubator To Be Provided Or Should Be Available In The Website. Compatible Incubator Should Be Provided Free Of Cost , Biological Indicator For Plasma Sterilizerspecifications:- Self Contained Geobacillus Stearothermophilus - Iso 11138:2017 Parts 1 And 3, Iso 11138-7:2019(En) And European Standard Certified Biological Test Pack With Auto Readers For Plasma Sterilizer, Smart Read,Stable Colour, Colour Change Should Not To Bereversible, Indicator Ink Should Not Fade In Storage Or Under Fluourescent Light. Spore Population In The Indicator: More Than 105 Cfu . Time Taken For Biological Indicator Result: Rapid Read Out ( Within 30 Min Preferably). Readout Technology: Initially By Fluorescence, Later By Ph Colour Change. Biological Indicator Ampule Should Be Integrated With Type 4 / Type 5 Chemical Indicators Additionally. Shelf Life: 2 Years.Quality Certification Report Regarding Spore Population,Z Value,D Value, To Be Provided. Brochure For The Bi And Incubator To Be Provided Or Should Be Available In The Website. Compatible Incubator Should Be Provided Free Of Cost , Steam Process Indicator Stripen Iso-11140-1 : 2005 Certified Class V Steam Sterilizer.Single Use Strips For Steam Sterilizer. Compatible With 121°C At 20 Minutes/ 134°C At 3 Minutes Process. Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light.It Should Containcolour Comparison Option After Sterilisation For Easy Confirmation. Indicator Color Should Not Change In Dry Heat. Strip With Adhesive Option Will Be Preferable For Easy Documentation. Brochure To Be Provided , Eto Process Indicator Stripspecification:-Process Indicator Should Be According To En Iso 11140 – 1, Class 4 / Class 5Indicator For Eo Gas Sterilization. Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light.It Should Containcolour Comparison Option After Sterilisation For Easy Confirmation.Should Be Lead Free. Indicator Strip With Adhesive Option Will Be Preferable For Easy Documentation. Brochure To Be Provided , Plasma (H2o2) Process Indicator Stripspecification:-Process Indicator Should Be According To En Iso 11140 – 1,Class 4 / Class 5Indicator For H2o2 Plasma Sterilization. Change Of Colour After Sterilisation Should Be Contrast With Initial Color And Colourchange Should Not Bereversible. Indicator Ink Shouldnot Fade In Storage Or Under Fluourescent Light.It Should Containcolour Comparison Option After Sterilisation For Easy Confirmation.Should Be Lead Free. Indicator Strip With Adhesive Option Will Be Preferable For Easy Documentation. Brochure To Be Provided , Batch Monitoring Chemical Indicator Strip For Bowie Dick Test :Air Removal Chemical Indicator Strip (Type 2)For Bowie Dick Process Challenge Device (Pcd)With Adhesive Option For Easy Documentation. Indicator Color Should Not Change In Dry Heat. Air Removal Test According To En 285 (7Kg) Or Aami/Ansi/St79 (4Kg Test) And Validated According To The Test Method Of Iso 11140-1+5 For Steam Sterilization. 10 Nos. Of Stainless Steel Pcd - Eu Version, According To En Iso 11140-4 And Hollow Load Test According To En 867-5 ( Brochure To Be Provided) To Be Provided Free Of Cost. Complete Data Sheet Of Both Batch Monitoring Chemical Indicator For Bowie Dick Test/ Pcd And Sample Should Be Submitted. 10 Nos. Of Pcd Device Should Be Provided On Free Of Cost. , Batch Monitoringchemical Indicator Stripfor Steam Sterilization: Type 2 Chemical Indicator To Be Used In Compact Pcd For Steam Sterilization According To En Iso - 11140-1 And Lab Report En Iso 17025. Indicators Should Have Adhesive For Easydocumentation And Should Not Change Color In Dry Heat As Per En Iso - 11140. 10 Nos. Of Compatiblecompact Stainless Steel Process Challenging Device (Pcd) – Specific Load Test According To En Iso 11140-1.( Brochure To Be Provided) Should Be Provided On Free Of Cost. Complete Data Sheet Of Both Batch Monitoring Chemical Indicator / Pcd And Sample Should Be Submitted. 10 Nos. Of Pcd Device Should Be Provided On Free Of Cost. , Batch Monitoringchemical Indicator Stripfor Eo Sterilization :Class-2 Chemical Indicator To Monitor Ethylene Oxide Sterilization Compatible To The Stainless-Steel Helix Pcd As Per En 1422.Should Be Lead Free. Should Be With Adhesive For Easy Documentation. 2 Nos. Of Compatible Metal Stainless Steel Process Challenge Device (Pcd) For Batch Monitoring System (Bms) -According To En 1422 Type Test For Large Sterilizer As Per En 285 ( Brochure To Be Provided) Should Be Provided On Free Of Cost. Complete Data Sheet Of Both Batch Monitoring Chemical Indicator / Pcd And Sample Should Be Submitted.2 Nos. Of Pcd Device Should Be Provided On Free Of Cost. , Batch Monitoringchemical Indicator Stripfor H2o2 (Plasma) Sterilization Type 2 Chemical Indicator To Be Used In Helix Pcd According To En Iso - 11140-1 And Lab Report En Iso 17025.Indicators Should Have Adhesive For Easydocumentation. 3 Nos. Of Compatiblehelix Process Challenge Device (Pcd) For Batch Monitoring System (Bms) According To En Iso 11140-1 ( Brochure To Be Provided) Should Be Provided On Free Of Cost. Complete Data Sheet Of Both Batch Monitoring Chemical Indicator / Pcd And Sample Should Be Submitted. 3 Nos. Of Pcd Device Should Be Provided On Free Of Cost. , Documentation Label For Steam Sterilizationspecification: - 3 Line Documentation Label With Integrated Steam Indicator With Adhesive Base. Should Comply With En Iso 11140-1.Indicator Colour Should Change Only In Steam Sterilization, Not In Dry Heat.Rate Must Be Quoted Per Label, Not Per Roll. 3 Nos. Label Guns With Ink Should Be Provided For Each 25000 Nos. Of Labels, On Loan Basis. , Documentation Label For Eto Sterilization.Specification: - 3 Line Documentation Label With Integrated Steam Indicator With Adhesive Base. Should Comply With En Iso 11140-1.Rate Must Be Quoted Per Label, Not Per Roll. 2Nos. Of Label Gun With Ink Should Be Provided For Each 25000 Nos. Of Labels, On Loan Basis. , Documentation Label For Plasma Sterilization.Specification: - 3 Line Documentation Label With Integrated Steam Indicator With Adhesive Base. Should Comply With En Iso 11140-1.Rate Must Be Quoted Per Label, Not Per Roll. 2 Nos. Of Label Gun With Ink Should Be Provided For Each 25000 Nos. Of Labels, On Loan Basis. , Spinal Needle With Whitacre Pencil Point Size: 25G X 90Mmspecifications: - Sterile, Disposable, Whitacre Pencil Point, Individually Packed.Graduated Metal Introducer & Translucent Hub With Colour Coding, Should Be Of Good Quality Material And Pack Without Any Risk Of Breach In Sterility.Eto/Gamma Sterilized. , Spinal Needle With Quincke Type Point Size: 23G X 90Mmspecifications: - Sterile, Disposable, Quincke Type Point, Individually Packed.Translucent Hub With Colour Coding, Should Be Of Good Quality Material And Pack Without Any Risk Of Breach In Sterility.Eto/Gamma Sterilized. , Spinal Needle With Quincke Type Point Size: 25G X 90Mmspecifications: - Sterile, Disposable, Quincke Point, Individually Packed.Translucent Hub With Colour Coding, Should Be Of Good Quality Material And Pack Without Any Risk Of Breach In Sterility.Eto/Gamma Sterilized. , Colour Coding Tag For Surgical Instruments:Indented To Adhere To Surgical Instruments For Identification, Organization, Management Using Various Colours.Should Be Able To Withstand Repeated Sterilization Cycles Suitable For 121 Degree C And 134 Degree C.Price Should Be Quoted Per Tag Not For Sheet(Brochure To Be Attached) , Sterilization Bins For Steam Sterilization:Sterilization Bins Cylindrical Type, Medium Size Measuring 12 Height 14 Diameter With Provision Of Holes For Steam Entry And Manual Locking Systems. , Heat Resistant Gloves: Specifications:Long (Upto Elbow), Resistant To High Temperature, To Be Used In Autoclave, Heat Resistant And Preserved Material, Smooth Finish With Good Hand Grip And Full Fingered, Large Size (24 Inches) , Thermal Printer Roll:Compatible For Use In Ethylene Oxide Sterilizer (Capacity : 452 Litres).Size : 2.3 X 10 Mtr. Roll , Heating Element, 6Kw Capacity, Compatible For Use In Microprocessor Controlled, High Pressure, Fully Automatic, 36Kw, Double Door Steam Sterilizer. , Heating Element Washer, Compatible For Use In Microprocessor Controlled, High Pressure, Fully Automatic, 36Kw, Double Door Steam Sterilizer, Functioning In Cssd, Jipmer. , Thermo Seal Tape: Used To Pack The Surgical Trays For Steam Sterilization. Size 18Mm × 50Mts. Material: Crepe Paper With Natural Rubber Adhesive For Medical Use.Should Sustain Temperature Of 134°C In A Autoclave. Should Not Leave The Adhesive Behind After Sterilization. , Sterile Cotton Gauze With Radio-Opaque Line Marker, Size: 5 X 5 Cms, 16Ply, Type 17 The Marker Should Be Made Up Of Multifilament Yarn With At Least 60% Barium Coated Which Will Not Break Or Come Out Separately During Usage.Each Should Have Folded Edges To Avoid Fraying Of The Fabric.The Material Should Have Beean Bleached Using Hydrogen Peroxide.Each Pack Should Have Eto Sterilized With Double Sealed Blister Pack For Secured Sterility With Sterility Indicator. , Sterile Cotton Gauze With Radio-Opaque Line Marker, Size: 7.5 X 7.5 Cms, 16Ply, Type 17 The Marker Should Be Made Up Of Multifilament Yarn With At Least 60% Barium Coated Which Will Not Break Or Come Out Separately During Usage.Each Should Have Folded Edges To Avoid Fraying Of The Fabric.The Material Should Have Beean Bleached Using Hydrogen Peroxide.Each Pack Should Have Eto Sterilized With Double Sealed Blister Pack For Secured Sterility With Sterility Indicator. , Sterile Cotton Gauze With Radio-Opaque Line Marker, Size: 10 X 10 Cms, 8Ply, Type 17 The Marker Should Be Made Up Of Multifilament Yarn With At Least 60% Barium Coated Which Will Not Break Or Come Out Separately During Usage.Each Should Have Folded Edges To Avoid Fraying Of The Fabric.The Material Should Have Beean Bleached Using Hydrogen Peroxide.Each Pack Should Have Eto Sterilized With Double Sealed Blister Pack For Secured Sterility With Sterility Indicator. , Sterile Surgical Mopping Pad With Radio-Opaque Line Marker And A Coloured Loop, Size: 30 X 30 Cms, 8Ply, Type 17.The Marker Should Be Made Up Of Multifilament Yarn With At Least 60% Barium Coated Which Will Not Break Or Come Out Separately During Usage.Each Should Have Folded And Stitched Edges To Avoid Fraying Of The Fabric.The Material Should Have Beean Bleached Using Hydrogen Peroxide.Each Pack Should Have Eto Sterilized With Double Sealed Blister Pack For Secured Sterility With Sterility Indicator. There Should Be A Coloured Loop For Identification. , Sterilization Containers With Compatible Ss Basket For Steam Sterilization : Dimesion Of Container In Mm: 1 Stu (600 X 300 X 260), Inner Basket Measuring (540X240x180): Stainless Steel Container Should Be Aisi 304 Grade, An Austentic Stainless Steel With Exceptional Mechanical Resistance And Highly Resistant Corrosion. Container Lid Should Have To Be Provided With A Protected Valve System That Assures A Mechanical Control Of Steam Penetrations And Sterility Preservation. The Valve Of Container Should Be Made In Aluminum, Consists Of Single Lid, Protected By Round Cup,Only In Lidto Assure Perfect Tightening During Transport.One Piece Gasket. Inner Ss Basket With Lid Should Be Made Up Of Aisi 304 Grade Stainless Steel, Perforated Sheet With Two Handless. Containers Should Have Atleast 7 Years Of Warranty. Comply With En Iso 17665-1, 16707-1 Standards. , Sterilization Containers With Compatible Ss Basket For Steam Sterilization : Dimesion Of Container In Mm: 3/4 Stu (460 X 300 X 260), Inner Basket Measuring (400X240x180): Stainless Steel Container Should Be Aisi 304 Grade, An Austentic Stainless Steel With Exceptional Mechanical Resistance And Highly Resistant Corrosion. Container Lid Should Have To Be Provided With A Protected Valve System That Assures A Mechanical Control Of Steam Penetrations And Sterility Preservation. The Valve Of Container Should Be Made In Aluminum, Consists Of Single Lid, Protected By Round Cup,Only In Lidto Assure Perfect Tightening During Transport.One Piece Gasket. Inner Ss Basket With Lid Should Be Made Up Of Aisi 304 Grade Stainless Steel, Perforated Sheet With Two Handless. Containers Should Have Atleast 7 Years Of Warranty. Comply With En Iso 17665-1, 16707-1 Standards. , Sterilization Containers With Compatible Ss Basket For Steam Sterilization : Dimesion Of Container In Mm: 1/2 Stu (300 X 300 X 260), Inner Basket Measuring (240X240x90): Stainless Steel Container Should Be Aisi 304 Grade, An Austentic Stainless Steel With Exceptional Mechanical Resistance And Highly Resistant Corrosion. Container Lid Should Have To Be Provided With A Protected Valve System That Assures A Mechanical Control Of Steam Penetrations And Sterility Preservation. The Valve Of Container Should Be Made In Aluminum, Consists Of Single Lid, Protected By Round Cup,Only In Lidto Assure Perfect Tightening During Transport.One Piece Gasket. Inner Ss Basket With Lid Should Be Made Up Of Aisi 304 Grade Stainless Steel, Perforated Sheet With Two Handless. Containers Should Have Atleast 7 Years Of Warranty. Comply With En Iso 17665-1, 16707-1 Standards. , Wired Mesh Tray: Stainless Steel Wire Mesh Tray Size 17 X 10 X 3 (L X B X H) Made Up Of 16 Gauge Wire Of 1.5Mm Thickness. Borders And Movable Handle Should Be Made Up Of 4Mm Thickness. Edges Should Be Smooth. It Should Be Designed For All Phases Of Instruments Processing (Washing, Disinfection, Ultra Sonic Cleaning, Sterilization, Etc.) Chemical Resistant. , Wired Mesh Tray: Stainless Steel Wire Mesh Tray Size 12 X 8 X 1.5 (L X B X H) Made Up Of 16 Gauge Wire Of 1.5Mm Thickness. Borders And Movable Handle Should Be Made Up Of 4Mm Thickness. Edges Should Be Smooth. It Should Be Designed For All Phases Of Instruments Processing (Washing, Disinfection, Ultra Sonic Cleaning, Sterilization, Etc.) Chemical Resistant. , Ss Containers For Surgical Instruments And Trays: High Quality Stainless Steel (Ss 304/316)Containers Measuring 100Cm X 60Cm X 30 Cm (L X Bx H) For Keeping Surgical Instruments And Trays In A Enzymatic Solution For Cleaning.Catalogue To Be Provided. , Tray Liner: For Keeping In The Bottom Of The Instruments Tray To Obsorb The Moisture During The Steam Sterilisation Process. Size55cm X 18Cm , Reusable Silicon Mesh Tray:For Keeping In The Bottom Of The Instruments Tray, Should Be Compatible With Steam Sterilisation Process. Size12 X 8. , Diaphragm Plate With Gasket (Cup Type) For Steam Sterilizer , I.V. Butterfly Needle With Catheter: Sterile, Single Use Scalpvein(Winged Needle) Infusion Set. Needle Size: 0.7Mm X 19Mm (25G),.It Should Have Flexible Kink Resistent Extension Tube (200Mm +/-5%) With Protective Needle Sheath.Shelf Life : = 3 Years, Standard: Is 16097 Latest Version. , Non-Consumable Items , Hand Dryer Should Be Wall Mount Type.Should Have Infrared Sensor For Automatic Detection Of Hands.Should Have Brushed 304 Ss Finish.Motor Should Be At Least2300 W And7500 Rpm.Dryer Should Deliver The Flow Of 7300 Lfm.Should Work On 230V, 50 Hz Power Supply.Should Supply With All Accessories Such As Clamps For Mounting( Brochure To Be Provided). , Drying Cabinet For Cssd Should Be Automatic In Operation.Inner Chamber Should Be Made Up Of Stainless Steel And Outer Chamber Should Be Of Epoxy Painted Crca Sheets.Should Have Heaters Of Minimum 1.5 Kw.There Should Be Provision For Setting The Drying Temperature And Drying Time.Approximate Capacity 200L Or Morewith Shelves To Keep Trays ( Brochure To Be Provided). , Colour Coding Tag System For Surgical Instruments With Accessories( Brochure To Be Provided) Number Of Instrumentsneed To Be Tagged: 6000 , Stainless Steel Trolley For Cssdspecifications: Material S.S. 304 Grade With Heavy Duty Castor Wheels.Size: 60 X 30 X 40(Lxbxh).3 Shelves And Castor Wheels Of 6Diameter , Stainless Steel Tablefor Cssd Stainless Steel Table With 1000 Kg Weight Bearing Capacity Measuring 7 Ft. X 2 Ft. X 1 (L X B X Thickness) Table Top. Table Height Should Be 2.5Ft. 4 To 6 Interconnected Legs, Each Leg Should Be 3 X 2. , Water Purifier 120 Litres Stainless Steel, 2 Faucets (Normal & Hot Water), 7 Stage Rowater Purifier System With Capacity Of 60 Lph. , Ultrasonic Cleaner (Ultrasonic Bath) For Surgical Instrument: Digital Microprocessor Controlled, Stainless Steel (Ss304/316, 16G & Outer Ss)Ultrasonic Surgical Instrument Cleaner 40 Litres Capacity, 40 ± 5 Khz Operating Frequency, Impulses Through Wash Water Containing Detergents And Electrical Heating. Complete Data / Brochure / Picture Should Be Submitted For Evaluation. , Document Scanner Sheetfed Digital Scanner, Resolution Upto 600 Dpi, Scan Speed Of Upto 65 Ppm / 130 Ipm, 2 Scan Mode (Simplex / Duplex), Scan File Format Including Pdf, Word, Excel, Power Point, Jpeg, Png, Etc., Both Grey Scale Mode And Colour Scanning. Complete Data / Brochure / Picture Should Be Submitted For Evaluation. , Sterile Storage Cabinets For Cssd Specifications: Material S.S. 304 Grade. Size: 40X 15X 60(Lxbxh), 4 Shelves, Double Doors With Lockable Facility And Uv Lights. , Digital Weighing Machine:Stainless Steel 600 X 600Mm Platform Size Weighing Machine With Led Display Least Count Upto 10 Gm To Maximum 150 Kg Weighing Capacity With One Side Protective Side Bar. , Atp Complete Handheld Device: A Reliable, Quick, Easy Use Atp Meter Measuring Rlu To Check For Microbial Contamination To Measure The Efficacy Of Cleaning Protocols On Surgical Instruments And Non-Critical Surfaces. Firm Suppose To Be Provide Compatible 50 Swab Free Of Cost Along With The Atp Meter

Key Value

Document Fees
INR 590 /-
EMD
INR 5000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail