Quotation For Supply And Laying Of Various Cables, Installation Of Ups Db And Associated Works At Cyberpark Kozhikode -, Kozhikode-Kerala

Government Departments has published Quotation For Supply And Laying Of Various Cables, Installation Of Ups Db And Associated Works At Cyberpark Kozhikode -. Submission Date for this Tender is 18-07-2024. Electrification Work Tenders in Kozhikode Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

44090534
Quotation For Supply And Laying Of Various Cables, Installation Of Ups Db And Associated Works At Cyberpark Kozhikode -
Open Tender
Indian
Kerala
Kozhikode
18-07-2024

Tender Details

Quotation For Supply And Laying Of Various Cables, Installation Of Ups Db And Associated Works At Cyberpark Kozhikode -A OFC Cable laying work at Cyberpark 1 Supply of 6 Core, Unitube Single Sheathed, Armoured, 9/125μm, OS1/OS2 outdoor Type Fibre Cable 2 Supply of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. 32/40mm 3 Laying of one number of armoured 6 Core fiber optic cable in the existing DWC pipe as required in direct ground below 75cm including excavation and refilling the trench but excluding sand cushioning and protective covering etc. 4 Supplying and fixing of following sizes of medium class PVC conduit with ISI along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 5 Laying of one number of armoured 6 Core fiber optic cable in the existing in the existing surface/recessed steel/ PVC conduit as required. B UPS Installation 6 Removing existing 40A 4P MCCB from the existing MSB Panel and storing in into a location specified by the Engineer in Charge 7 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.63 A, 16 KA, TPMCCB 8 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq. mm (clamped with 1mm thick saddle) 9 Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3 X 4 sq. mm Copper 10 Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 10 sq. mm Aluminium cable 11 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/Isolator) 4 way (4 + 12), Double door 12 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door 13 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 14 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A 15 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole 16 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 17 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/ 32amps 415 volts “C” curve TP MCB complete with connections, testing and commissioning etc. as required. 18 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm 19 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm 20 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm C Cable laying to Cyberpark Sports Arena Gate 22 Supply of XLPE insulated armoured cables with aluminium conductors for working voltages up to and including 1100V 4conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE. 4C x 50Sq. mm- 23 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size existing 63/50mm DWC pipe as required direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq. mm 24 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing 63/50mm DWC pipe as required in existing masonry open duct as required. Up to 35 sq. mm 25 Supply of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. 63/50mm 26 Core Cutting in the existing masonry chamber with a wall thickness of 15 cm. 27 Excavation for cable trenches of depth up to 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. 28 Labour Charge for Mason, Grade 2 29 Labour Charge for Khallasi

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail