}

Tender For Rajilyey Trainnig And Prasarcenter Pathrhiyeya In Gazipur, kanpur-Uttar Pradesh

Government Departments has published Tender For Rajilyey Trainnig And Prasarcenter Pathrhiyeya In Gazipur. Submission Date for this Tender is 17-07-2024. Brushes Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44072734
Corrigendum : Tender For Rajilyey Trainnig And Prasarcenter Pathrhiyeya In Gazipur
Open Tender
Indian
Uttar Pradesh
Kanpur
17-07-2024

Tender Details

Rajilyey Trainnig And Prasarcenter Pathrhiyeya In Gazipur - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Group C 3 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 4 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 5 Submains : 6 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 7 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 8 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 9 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 10 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 11 20 mm 12 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 13 5/6 A switch 14 3 pin 5/6 A socket outlet 15 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 16 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 17 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 18 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 19 1 or 2 Module (75mmX75mm) 20 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 21 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 22 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 23 Upto 450 mm sweep 24 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 25 2 Pair 26 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 27 MCBs & DB’s : 28 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 29 6 way (4 + 18), Double door 30 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 31 Single pole 32 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 33 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 34 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 35 ELCB/RCCB Switches : 36 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 37 40 A 38 63 A 39 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 40 Earthing Work : 41 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 42 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 43 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 44 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 45 L.T. Switch Panel Board : 46 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. 47 The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. 48 The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 49 CUBICAL PANEL BOARD ( MCCB TYPE ) 50 PANEL 51 Incoming - 52 200 Amp MCCB-1 No. 53 Bus-Bar - 54 200 Amp /415 Volt MCCB -1 No. 55 Outgoing - 56 63 Amp 4P MCCB - 2 Nos. (for power d.b.) 57 40 Amp 4P MCCB - 4 Nos. (for light d.b.) 58 63 Amp 4P MCCB - 1 Nos. (Spare) 59 40 Amp 4P MCCB - 1 Nos. (Spare) 60 (or As per requirment directed by Project Manager.) 61 Lighting Fixtures (Lights/Fans) : 62 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 63 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 64 Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) 65 Armoured Cables (Cable/Gland/Lug) : 66 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 67 size 95 sq mm x 3-1/2core 68 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 69 size 95 sq mm x 3-1/2core 70 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 71 size 50 sq mm 72 size 95 sq mm 73 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 74 Non-Schedule Items 75 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 76 AIR CONDITIONER SYSTEM 77 PART-B PROPOSED DEVELOPMENT OF SMART CLASS 78 Establishment of Smart Class with langusage l.ab support 79 Interactive Display Board 05 Inches Diagonal With custom casing with Green Board SITC of 65 Multipurpose Interactive digital board , native resolution •3,840 g 2,160 (UH()),Panei Technology- IPS,Brightness(Typ., cd/m2)-360 nits,l.ife r ine (Typ.)-300()0Hr%,Built in 24W (12W 12W) speakers, ,lnput - HDMl X3, RG8/ Audio,RJ45 ,optical output/eudio out, Embedded Writing Annotation Software-reuired Intuitive UX/UI with built-in annotation SW with Latest Features like Palm erasing, Finger and stylus writing , touch type - IR/ in-glass/ PCAP (10 Multi touch or more),Built in WI-Fi with dual antenna, Screen Sharing provision of 6 Devices at the Android, Mac, Windows, IOS Devices,BuiIt in Web browser and PC Less Operations to work on PDF, Excel, Word and PPT Files,2 slot installation and testing of learning Management Software Applications like Diksha, EP athshaala etc. (make CorneaB0BNNQV1JR /or equivalent) 80 registering from 50 student @ Rs, 6,500 per student and Connectivity to ext. audio deuces (VCD player/PC/VHS player etc), 81 Green Board/White Board for Computer Room, WB-06 Resin Steel Marker Board Frame Material AluminiumMaterial Resin SteelCountry of Origin Made in IndiaShape RectangleProduct Code WB-06Packaging Type BoxInstallation Type Wall Mounted 82 Installation of Inverter & Battery Combo (1 No. Cruze + 4 KVA Pure Sine Wave inverter, 3 No. RC 18000 150 Ah Tall Tubular Battery) 83 Safe and Hygenic Drinking Water Facility 84 150 Liters/hour L Water Cooler (Maximum Energy Consumption (Watt) 1550 Watt for 150 ltr/hrcooling cap.) 85 Fully automatic with auto cut off RO Potable Water Purification System (Filtration Capacity in liter/ hour 50, Manufacturers Quality System Certifications ISO 9001:2015) 86 150 MBPS Broadband Connection for Internet with Wifi Modem 87 Connection Charges for High speed Internet 88 Two Set of high frequency Modem Wi-Fi Speed Up to 867 Mbps/5 GHz + 300 Mbps/2.4 GHz, 5 Gigabit Ports, 4 External Antennas, MU-MtMO, Dual Band, WiFi Coverage with Access Point Mode, Wireless Router with LAN Cable connection 89 PART-C CCTV WORK 90 Supply, Installation & testing of Outdoor/Indoor 1080p HD indoor IP dome camera with 1/2.8 CMOS sensor pixel 1920 x 1080, IR on at 30IRE, 1/30s, 30fps, IR - 30 mtr, dynamic range 90db, true day/night, automatic electronic shutter, video compression H.264, motion/tamper, privacy mask, motion detection, auto varifocal lens 3 to 9 mm lens, audio - 1/1 channel in/out, full duplex audio, audio compression AAC, G.711, memory card slot (support up to 64GB), ONVIF profile S, CE, UL, FCC certified. 91 Supply, Installation, Testing & Commissioning of 8 Channel Digital Video Recorder with specifications as follow: Supported Image Format h.264 , H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 8 ; RAID 5, 320MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 4x 6TB can be installed. Certification: UL, CE, BIS, FCC. 92 6U rack with all accessories 93 Supply and laying of 3 core 1.5 sqmm copper cable unarmoured 94 Supply and laying of CAT 6 UTP cable 95 Supply and laying of 25mm dia PVC conduit. 96 Supply, installation and commissioning of workstation latest intel i7 7th generation processor, intel chipset motherboard, 8 GB DDR3 RAM, 2 TB SATA HDD at 7200 rpm, graphics card 2GB dedicated RAM with dual display ports DVI/HDMI port, DVD writer, Giga LAN card, keyboard, optical mouse as per list approved makes TFT monitors 21inch or bigger. 97 SITC of 40 flat screen HD professional LED suitable for 24x7 operation with remote control and wall mount unit / floor stand complete with making connection etc as per list of approved makes. 98 Supply, installation and testing of UPS 1 KVA capacity. 99 Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/ Poly Crystal line silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete as required:-a)Solar Photo voltaic Module of capacity 330 W porabove , manufactured in India, conforming to IS14286/ IEC61215 ,IS/IEC61730 - Part-1,IS/IEC61730 - Part-2. Solar Photo voltaic Module conversion efficiency shall not be less than 16.5% .PV modules used in solar power plants/ systems must be warranted for the in output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% attheend of 25 years.b) Power Conditioning Unit (PCU) of 350-800 VDC Input voltage range and 400 VAC, three phase, 4wire, 50Hz+/- 5 Hz, output voltage suitable to generate ACP ower with efficiency not less than 97%, to talharmonic distortion less than 3% and suitable for ambient temperature from 0 to50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d)FixingofArrayjunctionbox&MainjunctionboxwithIP65protectionandterminationarrangementforincomingandoutgoingcablealongwithglands,lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f)Connections&Interconnectionsbysupplying&fixingrequiredsizeXLPEinsulatedcopperconductor1.1kVgradearmouredpowerandcontrolcablesbetweensolarmodules,mainpowercabletogridsupplyPCUunitalongwithsupplying&fixingofnecessarychannel 100 less 5 percent department

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-07-2024 DATE EXTENSION Date 17-07-2024

Key Value

Document Fees
INR 1180 /-
EMD
INR 25000.0 /-
Tender Value
INR 24.90 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail