Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 63 kVA Distribution Transformer with Bimetallic Terminal Connectors, Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate, Gapless Surge Arrestor 9 kV ,10 kA ,LA with polymer housing, Stn. Type, 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type, 11kV Horngap fuse set 3 phase 200A, 25 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type, 9 Mtr. Long Pole( ST-410 SP33),11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm, GI Channel/Angle/Flat of sizes including clamps, Galvanized Nuts and Bolts, 32/63 amps TPN Switch Disconnector Fuse Unit, Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole, Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover,11KV polymeric composite pin insulator 12KV,5KN, Lighting impuse 75KV Positive and 80KV Nragtive ,creepage distance 320mm,LT Distribution Box for63/100/200/250KVA DTR with MCCB for incomer & SFU for outgoingCircuits, Galvanised Stay Set with 50 x 8mm stay clamp,guy insulator(2nos) anchor plate (200 X 200 X 6mm), nut bolts, 2 Nos turn buckles,1.8m long ,16mm diameter solid GS stay rod & 7/3.15mm dia GI Stranded wire complete,Wedge connectors/PG Clamps,Danger Plates with Clamps, GI Barded Wire for Anti Climbing ,3-Ø,4 Wire Trivector Meter with CT ,Cement bottoming 1:2:4 mix as per REC Standards .5cum/pole, Painting of poles Red Oxide, Painting of polesAluminium Paint ,Sundry items like aluminium lugs,jumpers,binding tape, |
| 2 | SITC11KV Tapping Point Mid span |
| 3 | SITC of 1KM of 11KV Line on 9MTR ST Poles,50mm²ACSR Conductor with half span of 52Mtr:: 9 Mtr Long POle( PCC WL 300KG ,ST-410 SP33) ,11Mtr Long Pole ( PCC WL 360KG ,ST-410 SP56) , GI V cross with top Bracket including clamp ,GI Channel X arm including clamps and braces 50mm²ACSR Conductor PG Clamps for 50mm²ACSR Conductor, 11 KV Polymeric composite Pin Insulator 12kV , 5KN,Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm,11 KV Polymeric composite disc Insulator 12kV ,min failing load 45KN,Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm ,Galvanized Nuts and Bolts,Danger Plates with Clamps , Anti Climbing Device with Clamps, Earthing pipe of 40 mm or GI Rod 20mm 2.5Mtr long through GI Strip, Red Oxide,Aluminium Paint , Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole ,Stone Pad (300mm X 300mm x 75 mm)Aluminium Jointing Sleeves,Galvanised Stay Set with 50 x 8mm stay clamp,guy insulator(2nos) anchor plate (200 X 200 X 6mm), nut bolts, 2 Nos turn buckles,1.8m long ,16mm diameter solid GS stay rod & 7/3.15mm dia GI Stranded wire complete . |
| 4 | DG SET 125 KVAThree Phase with AMF Panel, Water cooled , diesel engine , 4 Cylinder, liquid cooled, Turbocharged After cooled,developing 156 HP at 1500 RPM. This is electric start, compression ignition, 4 stroke engine design torun continuously 1500 RPM. Diesel conforms to present CPCBIV+ norms. The diesel engine comprises of following: -• Radiator with Fan • Electric starter motor with soft starting system• G3 as per ISO 8528 Part V class governor • Battery charging alternator• Dry type Air cleaner with service indicator • CRDI System• Lube Oil & Fuel filter • DOC , SCR• First fill of lube oil & coolant • IoT Remote Monitoring System ALTERNATOR:, suitable for continuous operation rated at 1500 rpm 415.00V, 0.80PF, 50.00Hz, Ph. in SPDP enclosure, self-excited, self-regulated Brush less, floor mounted. The alternatorconforms to IS:4722,BS EN 60034-1 & will be suitable for tropical condition.with Installation at site |
| 5 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm Dia (OD- 63 MM andID 51 MM) |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90mm dia (OD- 90 MM andID 76 MM) |
| 7 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm Dia ((OD- 120 MM andID 103 MM) |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a )25 mm |
| 10 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required . |
| 11 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required . |
| 12 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required . A)Single pole |
| 13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .b)Single pole and neutral |
| 14 | Supplying and fixing Following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 MA in the existing MCB DB complete with connections,testing and commissioning etc.as required.40A |
| 15 | Supplying and fixing Following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 MA in the existing MCB DB complete with connections,testing and commissioning etc.as required.63 A |
| 16 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required . b) 125 A,36KA,FPMCCB |
| 17 | Supplying, Instalaltion, Testing & Commissioning of1.1 grade, 3x1.5sqmm FRLS PVC insulated flexible copper conductor, Single core cable in the existing surface/recessed steel/ PVC Conduit as required. |
| 18 | Supplying, Instalaltion, Testing & Commissioning1.1 grade, 3x2.5sqmm FRLS PVC insulated flexible copper conductor, Single core cable in the existing surface/recessed steel/ PVC Conduit as required. |
| 19 | Supplying, Installation, Testing & Commissioning of following cable Al. conductor XLPE insulated PVC Tape inner sheathed for multi core cables , Armoured as per IS,PVC type ST to sheathed 650/1100V grade as per IS 7098 (part 1)19884Cx4 Sqmm |
| 20 | Supplying, Installation, Testing & Commissioning of following cable Al. conductor XLPE insulated PVC Tape inner sheathed for multi core cables , Armoured as per IS,PVC type ST to sheathed 650/1100V grade as per IS 7098 (part 1)19884Cx6 Sqmm |
| 21 | Supplying, Installation, Testing & Commissioning of following cable Al. conductor XLPE insulated PVC Tape inner sheathed for multi core cables , Armoured as per IS,PVC type ST to sheathed 650/1100V grade as per IS 7098 (part 1)19884Cx10 Sqmm |
| 22 | Supplying, Installation, Testing & Commissioning of following cable Al. conductor XLPE insulated PVC Tape inner sheathed for multi core cables , Armoured as per IS,PVC type ST to sheathed 650/1100V grade as per IS 7098 (part 1)19884Cx16 Sqmm |
| 23 | Supplying, Installation, Testing & Commissioning of following cable Al. conductor XLPE insulated PVC Tape inner sheathed for multi core cables , Armoured as per IS,PVC type ST to sheathed 650/1100V grade as per IS 7098 (part 1)19884Cx25 Sqmm |
| 24 | Supplying, Installation, Testing & Commissioning of following cable Al. conductor XLPE insulated PVC Tape inner sheathed for multi core cables , Armoured as per IS,PVC type ST to sheathed 650/1100V grade as per IS 7098 (part 1)19883.5C x 70 Sqmm |
| 25 | Supply, Installation, Testing & Commissioning of 12W LED Landscape outdoor LED Bollard made out of Aluminium casting complete 600-700mm long with PU paintand suitable post top LED light, PC diffuser opening for uniform distribution of light.Luminaire is provided with a base plate and fixing holes for directly mounting on the concrete pedestal. Height of Bollard between 600-700mm. Where Luminaire is wired with inbuilt driver with 4.5kV surge protection, Nominal Supply voltage will be 220-240V, power factor will be more than 0.95. And ingress protection will be IP65.CCT:3000K ± 250K. The branding name shall be embossed on the housing of the fixture. The minimum warranty shall be for 2 years. |
| 26 | SITC of 5 Mtr height flange mounted hot dip galvanized Octagonal pole made from HT steel plate,window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd,terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for Upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the Pole. Galvanization as per relevant IS.5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick including Foundation. Fabrication supplying and fixing Class B Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd. Foundation bolt size 16mmx600mmx4 nos. each inclusive 45 Watt LED light fixture. |
| 27 | Supply, Installation, Testing and Commissioning of 50 Watt LED floodlight luminaire 3000K colour temp. CRI>70, LED life 50000 burning hours 50° Temp. surge protection up to 3KV, IP65 and IK 06 with Die-cast aluminium housing, powder-coated finish, of following wattage.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 .Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . |
| 28 | Supply, Installation, Testing and Commissioning of 30 Watt LED floodlight luminaire 3000K colour temp. CRI>70, LED life 50000 burning hours 50° Temp. surge protection up to 3KV, IP65 and IK 06 with Die-cast aluminium housing, powder-coated finish, of following wattage.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 .Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . |
| 29 | Supply, Installation, Testing and Commissioning of 90 -100 Watt LED floodlight luminaire 3000K colour temp. CRI>70, LED life 50000 burning hours 50° Temp. surge protection up to 3KV, IP65 and IK 06 with Die-cast aluminium housing, powder-coated finish, of following wattage.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 .Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . |
| 30 | Supply,Installation,Testing and Commissioning of 25-30 Watt Warm White LEDLinear Wall Washer luminaire CCT 3000K ± 250K for illuminate 3D wall painting with aluminium extruded housing. Length of the luminaire shall be 1000mm in size.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270VAC ,50Hz , powerfactor>0.9. Fixture shall be suitable to operate at ambient temperature range of-5°Cto+50°C and shall be IP65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required Engineer-In-Charge. The branding name shall be embossed on the housing of the fixture. The minimum warranty shall be for 2 years. |
| 31 | Supply,Installation,Testing and Commissioning of 40-45 Watt Warm White LEDLinear Wall Washer luminaire CCT 3000K ± 250K for illuminate 3D wall painting with aluminium extruded housing. Length of the luminaire shall be 1000mm in size.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270VAC ,50Hz , powerfactor>0.9. Fixture shall be suitable to operate at ambient temperature range of-5°Cto+50°C and shall be IP65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required Engineer-In-Charge. The branding name shall be embossed on the housing of the fixture. The minimum warranty shall be for 2 years. |
| 32 | SITCJunction boxes outdoor type Supply made of Thermoplastic PolycaronateBoxes Mini. Size 93 x 93 x 62 mm in Black colour. The Junction Box Should be IP 67/69 ( IEC 60529 ) Thermoplastic PC weatherproof with multi level knockouts on four Side for cable Entry in different sizes . Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. The Box Should be UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4. The Joint Box should be Weatherproof : Rainwater proof, temperature resistant, Connecting Box as per IEC 60670-22 and IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. The box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable Terminals . The Junction Box with nut bolts complete all as per manufacturer’s instructions.Make : Cat Part :- KF 0202 B of Hensel/Siemens/GE Power/Schneider/ L&T/ABB. Manufacturer should submit test certificate as per above Standard. |
| 33 | SITCJunction boxes outdoor type Supply made of Thermoplastic PolycaronateBoxes Mini. Size 205 x 255 x 112 mm in Black colour. The Junction Box Should be IP 67/69 ( IEC 60529 ) Thermoplastic PC weatherproof with multi level knockouts on four Side for cable Entry in different sizes . Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. The Box Should be UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4. The Joint Box should be Weatherproof : Rainwater proof, temperature resistant, Connecting Box as per IEC 60670-22 and IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. The box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable Terminals . The Junction Box with nut bolts complete all as per manufacturer’s instructions.Make : Cat Part :- KF 02525 B of Hensel/Siemens/GE Power/Schneider/ L&T/ABB. Manufacturer should submit test certificate as per above Standard. |
| 34 | Supply, installation, Testing and Commissioning of power distribution control Panel made out of 2 mm sheet steel, powder coated gray paint shade RAL 7032 specially designed bus bar to provide safety suitable for accommodating MCCBs, 1 No, 400 Amp 50 KA FP MCCBas incoming, On Load Changeover of 400 Ampand 2 Nos 125 Amp FPMCCB as outgoing complete with 50 Hz 415 Volt AC Supply, prewired digital meter Module including Voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights for outdoor type IP-55 etc as reqd. (8 ways) . |
| 35 | Supply, installation, Testing and Commissioning of 12.5MTR shaft shall be in 2 section with hot dip Galvanised . There shall be circumferential Weld.It shall also include accessories for high mast including head frame,3point spension system with steel wire rope 6mm dia,double drum winch,cable,Galvanised Lantern carriage arrangement suitable for 6/12Luminaries .Supply of Foundation bolts manufactured from special steel along with nuts,washers,anchor plates&Temlates.Bottom Dia 360mm ,Top Dia 150mm ,Sheet Thk 3.3mm Automatic Control panel Fabricated with 16SWG CRCA sheet of size 600 X 600 X 300mm outdoortype with 25A Contractor ,63AMCCB,24 Hr Timer & Revese /Forward Switch. Flood light 150W Fixture made of pressure die cast Aluminium housing with front Toughened Glass with suitable lens for uniform having IP66 protection ,lumen 120/Wfor high Efficiency LED ,THD-10%, Potted driver with 4/6kva surge Protection. |
| 36 | CCTVS/I/T/C of 2MP varifocal lens Bullet IP Camera with following specifications:-Image Sensor: 1/2.8 2MP CMOS or better**Minimum Illumination: 0.1 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate:25 fps or better **Lens: 2.8 to 12mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (1920x1080) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 20mOperating Temperature: -20 to 55 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL |
| 37 | S/I/T/C of 2MPPTZCamera with following specifications:-Image Sensor: 1/2.8 2MP CMOS or better**Minimum Illumination: 0.1 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate:25 fps or better **Lens: 30 X ZOOMVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (1920x1080) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 20mOperating Temperature: -20 to 55 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL |
| 38 | S/I/T/C of 32 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or better**Network Throughput :160Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 2 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL |
| 39 | SITC of 6 TB surveillance HDD |
| 40 | SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch |
| 41 | Supply Installation testing Commissioning of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U |
| 42 | S/I/T/C ofLED Monitor full HD complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 400 NITS min. Video I/P port a) Min. 02 Nos HDMI 1920x1080. b) Min 01 No VGAContrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 HzInstallation at sitewith connections andalong with all accessories of 42 INCHESetc.complete as required with min. 3 year onsite warranty. |
| 43 | P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-55 weather proof pole box of inner dimension 300mm X 200mm X105 mm(NS) complete with suitable arrangment for fixing of 4 nos of 6 to32 amp single pole MCB & 63 Amp double pole isolator (MCB/Isolator excluded)with neutral link duly shorting on DIN channel with 2 nos. of MS clamps with SS back plate of suitalbe size with Danger monogramproperty printed on the cover etc as reqd. |
| 44 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD- 63 MM andID 51 MM) |
| 45 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 46 | Supply of following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable conforming to IS .694/2010 etc. as reqd. 3x 2.5 sqmm |
| 47 | Supply Installation testing and Commissioning ofPigtails 1 meter with Splicing and testing. |
| 48 | Supply Installation testing and Commissioning of opticalmedia converter gigabit SC to SC type up to 10 km. |
| 49 | Supply Installation testing and Commissioning ofLIU boxes complete with all accessories etc. as required of 12 ports |
| 50 | Supplying and laying of Optical Fiber Single Mode Cable (6-Fiber) on surface or in existing conduit etc complete i/cconnections etccomplete as required |
| 51 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 52 | Big Screen Supplying, Installation, Testing and Commissioning of IP65 (front)Out door LED video wall having aluminium diecast cabinet material complete with 6 mm pixel pitch having brightness of5500nitsViewingAngle(horizontal/vertical) 160°/ 140°, contrast 4000:1, Physical density 27777dot/m2,Thedisplayshallbecompactable with various formats like M.S. office, PDF, PPT & Movieswithsuitablecontrollerfor operation on 230V, 50 HZ AC supply. the life span of video wall shallnotbe lessthen 1,00,000hrs.andOSDshall be16/32bitOSD.Videowallshouldbeoperated throughexistingPC/Laptop/IPLANPort.The boardshalloperateaspergivenformatcomplete withcomputercompatibilityetccompleteas required. |
| 53 | Design,fabrication,supplying,installationof structural Iron frame work of Angle Iron 50mm x 50mm x 6mm thick on top and M.S pipe of 12\" dia on bottom with base plate 10 mm thick duly groudedwithCCfoundationofsize900mmx 900mmx1200(deep) forinstallation/fixingof LEDwall and for withstand the wind pressure upto 150KMPH at height 18 ft (aprrox) from ground i/c cutting, hosting welding, grinding and installation/fixing by CC or dash fastner as the case maybeandapplyingonecoatofsteelprimerand twoormorecoatofsyntheticenameledpaintetc completeasperdirectionofEngineer-in-chargeas reqd. |
| 54 | PA System SITC all weather proof loudspeaker forspeakers for otdoorground , having soundLF, HF - 1\" exit Max SPL not less than 128db /1m (peak), with continuous RMS power of 45 - 55 Watt RMS with programme power of 90 – 110 WattRMS & peak power of 180 - 220 Watt RMS with minimum sentivity of 97db, Nominal Impedance : 8ohms, nominal dispersion : 90 x 60, in birch plywoodpaint finish with wall mount bracket , suitable size MSframe box cover for protection etc. complete asrequired. |
| 55 | Supply installation testing & commissioning of Professional total 16 channel audio mixer with 16 mic inputs; 2 line inputs 2 stereo inputs; with inbuilt effects and equalizer, graphic EQ etc. complete as reqd. |
| 56 | Supply installation testing & commissioning of DualChannel Power Class H/ D amplifier for Subwoofer &Main Speakers & outdoor speakers 2000 watt ,Damping factor > 450, as required. |
| 57 | Supply installation testing & commissioning ofCordless Handheld Microphone with UHF frequency(10 Selectable Frequencies) with 10 MV RF output, etc.complete as required. |
| 58 | Supply, laying & Fixing of Speaker Lines: 2-Core, 2.5sq mm High definition Speaker Cable, PVC insulated inPVC jacket laid in existing conduits as reqd. |
| 59 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a )25 mm |
| 60 | Supplying, installation, testing & commissioning of mixer amplifier mic input, USB input and Bluetooth, 50 Watt, at 240 volt AC supply complete etc as required. |
| 61 | Supplying, installation, testing & commissioning of mixer amplifier mic input, USB input and Bluetooth, 75 Watt, at 240 volt AC supply complete etc as required. |
| 62 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 63 | P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-65 weatherproof pole box of inner dimension 500mm X 400mm X200 mm(NS) complete with suitable arrangement to accommodate for fixing mixer amplifier complete as required |
| 64 | Heavy Duty tripod Turnstile, Specification ;- Passage width of 520mm,throughput rate;35p/m,power supply ;100-240v,opertional voltage-24v,max power cosumption ;30w,frequency;50-60hz,prectection level;IP44,working tempertaure;25c to 70c,,electromagnetic drive-DC,dimension excluding bars-480x280x980,,semi auto mode,pure mechanical mode,bidirectional function,adustable timeout delay.Material-Housing(ss304),Barrier arms(stainless steel),Lid (Steel/artifical stone) |
| 65 | BOOM BARRIER - BGL-100 MaximumlengthofBoom:5mBoomRestStand:YesArmmaterial:Aluminium(withRed&GreenLEDindication)TimeforUp/down:6sInputcontrolsignal:DrycontactIngressprotectionDegree:IP54InputInterfacefor:1.Photocell2.Airswitch3.LoopdetectorLEDIndicator:Red/GreenOptionalInterface:Accesscontrolpanel,Standaloneaccesscontrol,ControlbuttonRemotecontrol:Yes,upto25metersMode:Automatic/ManualIncorporatedcontrolpanelwith3pushbuttons(STOP/UP/Down)tocontrolthemotorBumpingbounceback:Optional |
| 66 | NANDI - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 12 feet. Minimum Width – 12feet. Minimum Length – 28 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 67 | Hindu Universe- The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –20 feet. Minimum Width – 20feet. Minimum Length – 30 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. Theminiatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 68 | Samundra Manthan - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 12 feet. Minimum Width – 12 feet. Minimum Length – 30 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 69 | Trishul - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 30 feet. Minimum Width – 2 feet. Minimum Length –8 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 70 | Kashi Vishwanath Jyotirlinga, Varanasi - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 25 feet. Minimum Width – 15 feet. Minimum Length – 40 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 71 | Kedarnath Jyotirlinga, Rudraprayag, Uttarakhand - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 20 feet. Minimum Width –30 feet. Minimum Length – 20 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 72 | Ramanathaswamy Jyotirlinga, Rameshwaram - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites. Minimum Height – 30 feet. Minimum Width – 15 feet. Minimum Length – 27 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 73 | Mallikarjuna Jyotirlinga, Srisailam, Andhra Pradesh - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 20 feet. Minimum Width – 25 feet. Minimum Length – 40 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 74 | Bhimashankar Jyotirlinga, Bhorgiri, Maharashtra - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites. Minimum Height – 20 feet. Minimum Width – 15 feet. Minimum Length – 30 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 75 | Trimbakeshwar Jyotirlinga, Nasik, Maharashtra - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 20 feet. Minimum Width –25 feet. Minimum Length –35 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 76 | Somnath Jyotirlinga, Gir, Gujarat - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 30 feet. Minimum Width – 30feet. Minimum Length – 60 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 77 | Lingaraj Temple, Budhaneshwar, Odisha - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 35 feet. Minimum Width – 32 feet. Minimum Length – 55 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 78 | Baidyanath Temple, Deoghar Jharkhand - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 20 feet. Minimum Width – 25 feet. Minimum Length – 35 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 79 | Mahakaleshwar Jyotirlinga, Ujjain, Madhya Pradesh - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 25 feet. Minimum Width – 34 feet. Minimum Length – 47feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 80 | Omkareshwar Jyotirlinga, Khandwa, Madhya Pradesh The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 20 feet. Minimum Width – 15 feet. Minimum Length –40 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 81 | Pashupatinath Temple, Nepal - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 20 feet. Minimum Width – 25 feet. Minimum Length – 25 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 82 | Baijnath Temple, Baijnath , Himachal - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 20 feet. Minimum Width – 20 feet. Minimum Length – 40 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 83 | Veerabhadra Temple, Leepakshi, Andhra Pradesh - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –15 feet. Minimum Width – 15feet. Minimum Length – 35 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 84 | Shore Temple, Mahabalipuram, Tamil Nadu- The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –20 feet. Minimum Width – 20feet. Minimum Length – 30 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 85 | Nageshwar Jyotirlinga, Dwarka, Gujarat - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –20 feet. Minimum Width – 20 feet. Minimum Length – 40 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 86 | Kailasa Temple, Ellora, Maharashtra (Walkthrough) - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –25 feet. Minimum Width – 80feet. Minimum Length – 80 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 87 | Grishneshwar Temple, Aurangabad, Maharashtra - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –20 feet. Minimum Width – 15feet. Minimum Length – 30 feet.Foundation/Base Specs –Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge |
| 88 | Horticulture Ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bag |
| 89 | Supply of Ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in polybag of size 25 cm as per diraction of officer-in-charge |
| 90 | Supply of Rhapis Palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed,full of fresh andhealthy leaves in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer-in-charge |
| 91 | Supply of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in HDPE bag as per direction of the officer-in-charge |
| 92 | Supply of Wadelia trilobata,full of leaves in 15 cm size in plastic Bag as per direction of the officer-in-charge |
| 93 | Supply of Syngonium (Butterfly) variegated with 2-3 suckers healthy foliage in Earthen Pot/ Plastic Pot of size 25 cmas per direction of the officer-in-charge |
| 94 | Supply of Iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of Earthen Pot / Plastic Pot. As per direction of officer-in-charge |
| 95 | Supply of Tabernaemontana coronaria (Chandni single) variegated of height 105-120 cm., multibranched, bushy in big size HDPE bag as per direction of the officer-in-charge |
| 96 | Supply of Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge |
| 97 | Providing and Fixing Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge. |
| 98 | Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to150 cm ht., in 35 cm HDPE bags /Cement Pot as per direction of theofficer-in-charge. |
| 99 | Providing and Displaying Cyprus Golden Conical Shape 150 to 165 cm ht., with fresh and healthy Golden colour foliage in 35cm Cement Pot as per direction of the officer-in-charge. |
| 100 | Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. |
| 101 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 102 | Providing and stacking of Pterospermum acerifolium (Kanak Champa) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 103 | Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of theofficer-in-charge. |
| 104 | Providing and Displaying Cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. |
| 105 | Providing and stacking of Largerstroemia indica diffrent color of height 90-105 cm. multibranched in poly bags of size 25 cm as per direction of the officer-in-charge. |
| 106 | Bauhinia blakeana (Kachnar) diffrent color height 120-150 cm. in big poly bag size 25 cm |
| 107 | Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 108 | Providing and Fixing fishtail palm ht. 240cm bottom girth 40-50 cm well developed in big HDPE bag |
| 109 | Providing and Fixing foxtail palm ht. 240cm bottom girth 40-50 cm well developed in big HDPE bag |
| 110 | Providing and Fixing croton petra ht. 20-45cmin big HDPE bag |
| 111 | Providing and Fixing dracaena song of india ht. 20-45cmin big HDPE bag |
| 112 | Phyllanthus emblica height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bag |
| 113 | Supply of mimusops elengi of height 180-195 cm. with 6-7 branches and healthy foliage in HDPE as per diraction of officer-in-charge |
| 114 | Providing and Fixing terminalia Arjuna of height 150-165 cm height in big polybags of 25 cmas per direction of the officer-in-charge. |
| 115 | Providing and Fixing Eugenia jambolana of height 150-165 cm height in big polybags of 25 cmas per direction of the officer-in-charge. |
| 116 | Providing and Stacking of Alovera well developed in earthen pot of size 20cm as per directionof the officer-in-charge. |
| 117 | Supply of Hibiscus variegated, of height 60-75 cm., full of branches well developed in 15 cm size of Earthen Pot / Plastic Pot. As per direction of officer-in-charge |
| 118 | Providing and Stacking of Lemon grass of ht. 30 cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge. |
| 119 | Supply of Lawsonia Indica, of height 80-95 cm. well developed in 25 cm size of Plastic Pot As per direction of officer-in-charge |
| 120 | Supply of Nerium Oleander, of height 60-75 cm. Multibranched well developed in 25 cm size of Plastic Pot As per direction of officer-in-charge |
| 121 | Supply of Vinica, of height 60-75 cm. Multibranched well developed in 25 cm size of Plastic Pot As per direction of officer-in-charge |
| 122 | Supply of Holi Basil (Tulsi), of height 60-75 cm. Multibranched well developed in 25 cm size of Plastic Pot As per direction of officer-in-charge |
| 123 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 80 mm nominal inner dia Pipes |
| 124 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia Pipes |
| 125 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 126 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 127 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 128 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 129 | Metro sheet Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required, in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 130 | Providing and fixing of Metro Sheet Pre painted galvanized HI-Rib Roofing/Cladding system comprising of profit sheeting having 1060mm cover width, length 3657.6 (12 foot) thickness 0.50mm. The sheet shall have minimum two/three small stiffing ribs in between pans, zinc coating mass total of (both side) as per IS:277, with coating of regualr modified polyester paint (RMP) system as per IS:12246. The color coating shall comprise of 15-20 micron finish coat over 5-7 micron primer coat on the exposed side and 5-7 micron over 5 micron primer on back side. |
| 131 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand)cluding 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 132 | Providing and laying in position cement concrete of specified grade excluding the cost of centering andhuttering - All work up to plinth level1:5:10 (1 cement : 5 oarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) |
| 133 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) cum |
| 134 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works |
| 135 | CC for flooring Provision and laying in position cement concrete of specified grade excluding and cost of centering and shuttering. Allwork upto plinth level in CC 1:3:6 (1 Cement: 3Coarse Sand: 6 graded stone aggregate 20 mm nominal size) |
| 136 | Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 137 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) |
| 138 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 139 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 140 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 141 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 142 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 143 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Plinth Band) |
| 144 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Lintel Band) |
| 145 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Beam) |
| 146 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 147 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 148 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 149 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :(1 cement : 6 coarse sand) (230mm wall) |
| 150 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (1 cement : 4 coarse sand) |
| 151 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing toframe with 10 mm diameter bolts, nuts and woodenplugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 152 | Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 153 | 5 mm thick solid foam PVC panel of required size with moulded/ extruded beading of appropriate design shape and size as per manufacturer\"s specifications (to secure the panel insert tight in place within the style and rails of shutter) matching the colour and shade of shutter frame. Non decorative type. |
| 154 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 155 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. In Outer Side Door |
| 156 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with (4.0mm thick float glass) |
| 157 | 12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand |
| 158 | 12mm thick plaster in Exterior walls with proportion of 1:6 cement & approved coarse sand |
| 159 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 160 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 161 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 162 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 163 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement |
| 164 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 165 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.. |
| 166 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 167 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 168 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 169 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 170 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 171 | Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 250/ 300/ 400mm and length of 595 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of > 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework(Alloy 6063 T5/T6) consisting of vertical \"T\" (for intermediates)/ \"L\"(for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 600mm c/cmatching to the tile vertical grid, and horizontal aluminium \"C\"-clamps of size 56x25x2mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/ c matching to the tile horizontal grid with two numbers of selfdrilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical \"T\"/\"L/ Tubular\" sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets(galvanizing thickness of minimum 80 microns)of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tilesshall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be additionally secured to the horizontal ‘C’ clamps using special SS clips of required size which shall be inserted and pressed into position on the ‘C’ clamps holding the tiles and the cuttiles shall be glued at points to the horizontal ‘C’ clamps by using MS Polymer sealant adhesive. The vertical joint open groove between two adjacent tiles shall be 5mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in- Charge. Note : Scaffolding wherever required to be paid separately.With 16mm thickness (+/- 10%) terracotta tiles of other than grey colors |
| 172 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 173 | Centering and shuttering including strutting, propping etc. and removal of form for Plinth Beam |
| 174 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel Beam |
| 175 | Centering and shuttering including strutting, propping etc. and removal of form for Beam |
| 176 | Centering and shuttering including strutting, propping etc. and removal of form for Slab |
| 177 | Providing and fixing water closet squatting pan (Indlan type W.C. pan) with 100mm sand cast Iron P or Strap, 10 litre low level white P. V.C. flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever requiredWhite Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 178 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required ::Parryware /Hindware /Seabird /Orient (Coral)or equivalentW.C. pan with ISI marked white solid plastic seat and lid |
| 179 | Providing and fixing white vetreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of two urinal basins with 5 litre white P.V.C. automaticflushing cistern |
| 180 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 181 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 182 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 183 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia |
| 184 | Providing and fixing unplasticised PVC connection pipe with brass unions15 mm nominal bore |
| 185 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 186 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore |
| 187 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15mm nominal bore |
| 188 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm |
| 189 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.110 mm |
| 190 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.110 mm |
| 191 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm |
| 192 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 193 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 194 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.15mm dia nominal outer dia pipes |
| 195 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.20mm dia nominal outer dia pipes |
| 196 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.25mm dia nominal outer dia pipes |
| 197 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25mm dia nominal bore |
| 198 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.32mm dia nominal bore |
| 199 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25mm dia nominal bore |
| 200 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.32mm dia nominal bore |
| 201 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].Capcity in Per Liters |
| 202 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 203 | Providing, laying and jointing glazed stoneware pipes grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.200 mm diameter |
| 204 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design200 mm diameter |
| 205 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard designWith Sewer bricks conforming to IS : 4885 |
| 206 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 207 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.a) 110mm dia P.V.C. pipe |
| 208 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.b) 90mm dia P.V.C. pipe |
| 209 | Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince)P-Trap type Floor Trap 110 x 90mm |
| 210 | Providing and fixingterminal guard.a) 110mm |
| 211 | Providing and fixingterminal guard.b) 90mm |
| 212 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.110mm bend |
| 213 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.90 mm bend |
| 214 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.110mm |
| 215 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.90mm |
| 216 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.90x90x90 mm |
| 217 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.110x110x110 mm |
| 218 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.. Group BLight |
| 219 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.. Group BExhust |
| 220 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2x1.5sq. Mm |
| 221 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 222 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required.6 Module (125mmX75mm) |
| 223 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 224 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 225 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 226 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required. |
| 227 | Providing and fixing 256 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required. |
| 228 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door |
| 229 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 230 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 231 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 25 sg. mm (25mm) |
| 232 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. Cat AA |
| 233 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Cat AA |
| 234 | Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required |
| 235 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 236 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 237 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 238 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 239 | Centering and shuttering including strutting, propping etc. and removal of form for Slab |
| 240 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 241 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 242 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20mm thick |
| 243 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 244 | Providing M.S. foot rests including fixing in tank with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 245 | the cover to be not less than 58 kg (DSR 19.18.2) |
| 246 | C.I. Plain bend (DSR 17.39.1.2) |
| 247 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1) |
| 248 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 249 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 250 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 251 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 252 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Footing) |
| 253 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (Cloumn) |
| 254 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Ground Beam) |
| 255 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Beam) |
| 256 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Seps) |
| 257 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 258 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 259 | 12mm thick plaster with 1:6 cement & coarse sand with all labour, T&P complete. |
| 260 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 261 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 262 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 263 | Centering and shuttering including strutting, propping etc. and removal of form for Footing |
| 264 | Centering and shuttering including strutting, propping etc. and removal of form for Column |
| 265 | Centering and shuttering including strutting, propping etc. and removal of form for Ground Beam |
| 266 | Centering and shuttering including strutting, propping etc. and removal of form forBeam |
| 267 | Centering and shuttering including strutting, propping etc. and removal of form for Steps |