}

Tender For Supply Installation Testing And Commissioning Of Fire Detection System Incl All Necessary Items At Khidirpore Maternity Home Annex 5 Ipgmer Sskm Hospital Centre Of Excellence Ekbalpur Kolkata 700 023, kolkata-West Bengal

Government Departments has published Tender For Supply Installation Testing And Commissioning Of Fire Detection System Incl All Necessary Items At Khidirpore Maternity Home Annex 5 Ipgmer Sskm Hospital Centre Of Excellence Ekbalpur Kolkata 700 023. Submission Date for this Tender is 02-08-2024. Indicators and Reagents Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

44019181
Corrigendum : Tender For Supply Installation Testing And Commissioning Of Fire Detection System Incl All Necessary Items At Khidirpore Maternity Home Annex 5 Ipgmer Sskm Hospital Centre Of Excellence Ekbalpur Kolkata 700 023
Open Tender
Indian
West Bengal
Kolkata
02-08-2024

Tender Details

Supply Installation Testing And Commissioning Of Fire Detection System Incl All Necessary Items At Khidirpore Maternity Home Annex 5 Ipgmer Sskm Hospital Centre Of Excellence Ekbalpur Kolkata 700 023-- 1 Supply, Installation, Testing & Commisioning of Microprocessor basedaddressablefully networkablefirealarmcontrolpanel( VDS / UL approved ) suitable for the devicesasstatedinthepreviousitemsofthis BOQ along with 20% spare capacity witheach loop loading not exceeding 80% of thefull capacityofdetectorsanddevicestaken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numericliquid crystal display.The panel shall be soft addressable type andshall be able to give pin point location of all fire/ fault conditions.Further,thepanelmustbeableto automaticallyswitchoffrespectivecontrol switcheswithhelpmonitormodule whenever anyalarmistriggered.ThePanelshouldbe able to store sufficient numbers oflog events in its Memoryasperrecommendedstandards. Thepanel shouldhave extraloop cardslot for expansion of capcity twice. 2 The panel shall have in built rectifier,provision for external & internal printer ( if required ), Loop cards,L C D unit to indicate Fire/Fault Signal with address and analog output,complete in all respects,in built Surge protection facility, integralSMFleadacidbatterieswithsealed cellsof24Vcapableofrunning for24hours normal workingandthenbecapable of operating thesystem for60 minutesduring Emergencycondition,withintegralbattery charger complete in all respect as required. 3 The FACP shall be capable of being networked (futureexpansion)withothersimilarFACP located at different part of the premises through singleRS485modbus.TheFACPshallhave provision for interfacing with the public address system,remotecomputerandBMS interface.Thesystemmustbepreloadedwith licenced software. (ApprovedMake:Siemens CerberusPro/Honeywell / Bosch / Carrier as per choice of EIC.) 4 Supply,Installation,Testing&Commisioningof Micropresssor controlled Addressable MultisensordetectorIP42(VDS/ UL approved)with inbuiltopticalsmokesensors and heat detector sensor with inbuilt short circuit fault isolatoras per NFPA style 7 wiring completewithbase(Note:Detectorswithout built-in fault isolator is also acceptable provided oneindependentshortcircuitfaultisolatorper detectoristobeprovidedextrawithoutextra cost)thedetectorsshouldhavebuiltin response indicator with LED indicator. The detectorshouldhave360degreeopticalview with single / multiple LED that blinks on actuationof detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (ApprovedMake:Siemens CerberusPro/Honeywell / Bosch / Carrier as per choice of EIC.) 5 Supply,Installation,Testing&Commisioningof MicropresssorcontrolledAddressableHeat Detector(VDS/ULapproved)with combinationoffixedtypeandrateofriseof tempature feature.Detector shallhave maximum triggering temparature programmable from 60 deg C to 80 der C having high level of immunity to electromagnetic influence and show alarmsignallimittemparatureis reached.Detector shall have inbuild short circuit fault isolation as per NEPA style 7 wiring completewithbase(NoteDetectorwithoutbuilt in fault isolator is also acceptable provided one independent short circuit fault isolator per detectoristobeprovidedextrawithoutextra cost the detectors should have built in response indicatorwithLEDindicator (ApprovedMake:Siemens CerberusPro/Honeywell / Bosch / Carrier as per choice of EIC.) 6 Supply, Installation,Testing & Commisioning of Addressable Manual Call Point( VDS / UL approved ) with in built short circuit fault isolatoras per NFPA style 7 wiring complete as required. (ApprovedMake:Siemens CerberusPro/Honeywell / Bosch / Carrier as per choice of EIC.) 7 Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db )cum strobe(strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL approved) approved. (ApprovedMake:Siemens CerberusPro/Honeywell / Bosch / Carrier as per choice of EIC.) 8 Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab) through 19 mm dia PVC FR type Rigid Conduit pipe including S & laying of the 19 mm dia PVC FR type Rigid Conduit pipewith necessary arrangement as per G.S. (Make : Precision / Polycab) on the surface of the wall. 9 Checking, testing & necessary modification of the existing wiring with modification of loops, circuits if needed as per direction of EIC. 10 TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. 11 TERMS & CONDITIONS :-The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules 12 Defect Liabibility Period 1 (One) year 13 Make & model of each and every material to be approved by EIC

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-07-2024 Change of Date of Bid Submission Closing date and Bid Opening date of Date of Bid Submission Closing date and Bid Opening date Date 02-08-2024

Key Value

Document Fees
Refer document
EMD
INR 20268.0 /-
Tender Value
INR 10.13 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail