| 1 | Disconnecting electric connectionof the split AC cap 2.00 TR from its stabilizer or its electric board and remove the front cover of indoor AC unit and clean it with pressure water including cleaning wire mesh/ brush/nylon brush without spoiling inside area of room, then refixing the front cover of indoor unit split type AC including cleaning of air filter.Remove the outer cover of out door unit and covered the condenser moto with ploythene/ plastic cover so that water shall not be entered in the motor while cleaning the unit with pressure water and applyingcleaner solution and cleanwire mesh with bursh/nylon brush to the condensing coil of out door unit including greasing of fan motor, checking of complete wiring of ACs and tightening all electrical connection with thimble and reconnecting the electrical connection with DBs, Stabilizer as per site condition, Note- Spares required for replacement will be measured and paid separately |
| 2 | S&F in replacementnew Running/ starting capacitors suitable for split ACcap 2.00 TR . Make :- Keltron/ Siemens/ Tibcon/ Sarda. |
| 3 | S&F in replacementnew Thermostatic switch suitable for split ACcap 2.00 TR . Make:- utrtol/Siemens /Carrier/ Tibcon/ Sarda. |
| 4 | S&F in replacementnewFan Motor for out door unit suitable for split ACcap 2.00 TR Make:- Ranutrtol/ Siemens/Carrier/Tibcon/Sarda |
| 5 | S&F in replacementnew Electronic Display Boardsuitable for split AC cap 2.00 TR Make :As per OEM |
| 6 | S&F in replacementnew Swing Motor suitable for split ACcap 2.00TR Make :As per OEM |
| 7 | S&F in replacementnew evaporator coil copper for split AC cap2.0 TR Make :As per OEM |
| 8 | S&F in replacementnew condencer coil copper for split AC cap2.0 TR Make :As per OEM |
| 9 | S&F in replacementnew copper pipe of size 1/4\" for split AC cap2.0 TR |
| 10 | S&F in replacementnewcopper pipe of size 3/8\" for split AC cap 2.0 TR |
| 11 | S&F in replacementnew insulation for pipe of size 1/4\" or 3/8\" for ACcap 2.0 TR |
| 12 | M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing on indoor/oudoor of copper pipe of AC 2.0 TR |
| 13 | M&Lfor charging refrigerant gas (Mafrom / Floron ) after pressure test to a compressor for split type AC 2.0 TR Capacity |
| 14 | S&F in replacementnewnylon air filter cleanable indigenous of suitable size for thesplit type AC 2.0 TR Capacity complete all as directed. |
| 15 | S&F in replacementnew fan blades suitable for condencer motor for the split type air conditioners2TR capacity all as directed.Make :As per OEM |
| 16 | S&F in replacementnew balance centrifugal blower with motor for the split air conditioners of the2 TR capacity complete all as directed.Make :As per OEM |
| 17 | S&F in replacementnew cord lessremote suitable for split AC of capacity 2.0 TR /1.5 TR as directed by Engineer-in-charge Make :As per OEM |
| 18 | S&F in replacementnewprinted circuit board (PCB)of 2 TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed.Make :As per OEM |
| 19 | S&F in replacementnewprinted circuit board (PCB)for inverter AC 1.5 TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed.Make :As per OEM |
| 20 | S&F in replacementnewprinted circuit board (PCB)for inverter AC2TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed.Make :As per OEM |
| 21 | Disconnecting the electrical connections and remove the split type A/C including copper pipe of capacity 1.5TR/2TRfrom the existing position and shifting the same to the near location, re-connecting the A/C after making the suitablehole with necessary connections including closing the hole at removed place with brick masonry matching with existing colour all as directed. |
| 22 | Taking down unsv indoor unit and refixing indoor unit2 Ton Cap after replacing defective copper coil i.e. (evaporator) including cutting brazing leak testing, gas charging reconnecting and testing complete all as specified and directed. Make :LG/Voltas/Blue Star/Carrier |
| 23 | Disconnecting electric connectionof the split type AC 1.5 TR from its stabilizer or its electric board and taking out from its position, remove the front cover and outer cover, cleaning it with pressure water including cleaning ofwire mesh/ brush/nylon brush with pressure waterwithout spoiling inside area of room including cleaning of air filter, refixing the outer cover and front cover, greasing all moving parts. Checking and reconnecting electrical connection of DBs, Stabilizer,including checking of wiring of ACs as per site condition and tightening all electrical connection with thimble. Note - Spares required for replacement will be measured and paid separately |
| 24 | S&F in replacementnewRunning / Starting capacitors suitable forsplit type AC 1.5 ton . Make :- Keltron/ Siemens/ Tibcon/ Sarda. |
| 25 | S&F in replacementnew Swing Motor suitable forsplit type AC 1.5 ton Make :As per OEM |
| 26 | S&F in replacementnewcopper evaporator coilfor 1.5 ton split type AC.Make :As per OEM |
| 27 | S&F in replacementnew copper condencer coil for 1.5 ton split type AC.Make :As per OEM |
| 28 | S&F in replacementnew Electronic Display Boardsuitable forsplit type AC 1.5 ton.Make :As per OEM |
| 29 | S&F in replacementnew dual speed blower fan motor1/5 H.P. by disconnecting all the electrical connections and reconnecting same with electrical connections and testing for the split type air conditioners complete all as directed.Make :As per OEM |
| 30 | S&F in replacementnew air filter cleanable indigenous of suitable size for the splittype air conditioners of 1.5 ton capacity complete all as directed. |
| 31 | M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing of copper pipe split AC 1.50 TR |
| 32 | M&L for charging refrigerant gas (Mafrom / Floron ) after pressure test to a compressor for split type 1.5TR Capacity |
| 33 | M&L for carrying out repairs/maintenance/servicing of water cooler storage type of 40/80,60/120 Litres capacity, flushing of storage tank and chemical cleaning, repair/replaement of unserviceable/ worn out spares and accessores cleaning of drain pipes, float valves, s/s tray, push tap, body frames and base plates fan motor all as specified and directed by Engineer-in-Charge. Note-Spares required for replacement will be measured and paid separately |
| 34 | S&F in replacementnew compressor suitable for 40/80,60/120ltrs water coolerMake: LG/ Blue Star/ Samsung |
| 35 | S&F in replacementnew copper condenser coil suitable for 40/80,60/120ltrs water cooler.Make :As per OEM |
| 36 | S&F in replacementnew running/starting capacitor suitable for 40/80,60/120ltrs water cooler. Make-Keltron/ Siemens/ Tibcon/ Sarda. |
| 37 | S&F in replacementnewCP push type Water tap 15 mm size suitable forwater cooler storage type of 80/40,60/120Litres |
| 38 | S&F in replacementnew relay suitable for 40/80,60/120ltrs water cooler.Make :As per OEM |
| 39 | S&F in replacementnew door lock with key suitable for 40/80,60/120ltrs water cooler.Make :As per OEM |
| 40 | M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for 40/80,60/120 ltrs water cooler |
| 41 | Material & labour for charging refrigerant gas after pressure test for 40/80 ltrs water cooler with existing type gas R-22,134a |
| 42 | M&L for carrying out repair/ maintenance/ servicing ofRefrigerator of 165 Ltrs,180 ltrs 250 Ltrsand 310 Ltrs cap periodic cleaning,checking of electrical circuitand accessories to make the Refrigerator in good working condition all as specified and directed by Engineer-in-Charge. Make:LG /GodrejNote- Gas charging ifrequiredwill be measured and paid separately |
| 43 | M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for Refigarator of 180-320 ltr cap |
| 44 | M&L for charging refrigerant gas after pressure testof 180-320 ltr cap Refrigerator with existing type gas R-22,134a |
| 45 | M&L for carrying out repair/ maintenance/ servicing of Deep freezer 320ltr cap Freezer periodic cleaning, cleaning of water tub and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Deep Freezer in good working condition all as specified and directed by Engineer-in-Charge. Note- Spares required for replacement will be measured and paid separately Make: Voltas |
| 46 | S&F in replacementnew copper condenser coilfor Deep freezer 320ltr cap.Make :As per OEM |
| 47 | S&F in replacementnew condenser fan motor for Deep freezer 320ltr cap.Make :As per OEM |
| 48 | S&F in replacementnew thermostate for Deep freezer 320ltr cap.Make :As per OEM |
| 49 | M&L for Leak test with CO2/Nitrogen gas and arrest leakage with brazing forDeep freezer 320ltr cap |
| 50 | M&L for chargingrefrigerant gas after pressure test ofDeep freezer 320ltrcap with existing type gas R-22,134a |
| 51 | S&F in replacement PVC flexible hose of 20 mm dia with all accessorfes fixed on wall/ceiling/roof etc with suitable GI saddles and screws for connecting with split type Air Conditioner as drain pipe complete all as specified and directed. |
| 52 | S&F in replacement Rigid PVC pipe of 20 mm dia with all accessorfes fixed on wall/ceiling/roof etc with suitable GI saddles and screws for connecting with split type Air Conditioner as drain pipe complete all as specified and directed.Make-AKG,Plaza,Prince |
| 53 | Taking down, cleaning and servicing ofevaporative desert cooler of capacity of 3000 / 4000 Cum/Hr and refixing the same in original position complete all as directed. |
| 54 | S&F in replacementnew fan motor working on 230 Volts 50 Hz 1/7 H.P. and reconnecting the same with electrical connections for the evaporative desert cooler of capacity of 3000 / 4000 Cum/Hr complete all as directed.MAKE: COOL HOME/KHAITAN /CG |
| 55 | S&F in replacement new water pump working on 230 Volts 50 Hz 1/66 H.P. and reconnecting the same with electrical/water connections for the evaporative desert cooler of capacity 3000/4000 cum/hr complete all as directed.MAKE: KHAITAN/CG/COOL HOME |
| 56 | S&F in replacementnew Evaporative Cellulose Cooling Padfor the evaporative desert cooler of capacity 3000/4000 cum/ Hr. |
| 57 | S&F in replacementnew selector switch and reconnecting the same with electrical connections for the evaporative desert cooler of capacity 3000/4000 Cu.m/Hr. complete all as directed |