| 1 | Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed. Notes : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations |
| 2 | M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed. |
| 3 | M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directedat a level not exceeding 1.5 mtr above starting point complete all as specified and directed. |
| 4 | Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed.(NOTE : Thickness after punning shall be measured for payment) |
| 5 | M&L for Un-reinforced precast concrete cable cover class LV type I, flat, size 250mm x 150mm x 40mm as proteciton to under ground cable laid dry flat adjoining each other complete all as specified and directed |
| 6 | Fixing / laying only Un-reinforced precast concrete cable cover of any description as obtained from dismantling of the cable complete all as specified and directed. |
| 7 | Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 80 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed . Make of pipe TATA / Jindal / Swastik / Prakash / BSTor any other ISI marked make approved by GE.(Note : PCC work shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 8 | Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed . Make of pipe TATA / Jindal / Swastik / Prakash / BSTor any other ISI marked make approved by GE.(Note : PCC work shall be measured and paid seperatly under Sch \"A\" relevent item) |
| 9 | Supply, transporting, erecting and fixing in true verticalposition steel tubular swaged pole type410 SP-31, 9M long complete with cast ironbase plate 6mm thick pole cap including preparation of new steel surfaces of pole and applying with two coats of aluminium paint over a coat of red oxide primer including marking of Pole No with black paint and taking down and dismantling old unserviceable steel tubular pole 9M long complete all as specified and directed.NOTE: Excavation & PCC work shall be measured & paid seperately under respective items of BOQ. |
| 10 | M&L in replacement of UNSV stay assembly 300x300x3mm completewith accessories such as GI stay bow 20mm dia 400mm long, GI stay plate 300x300x3mm stay road 16mm dia 1800 mm long GI nuts, bolts loop insulator MS clamps,galvanized iron stranded stay wire of size 7/3.15 mm dia includingnecessary excavation PCC work (PCC workMS clamp to pole excavation and earth workwill be measured & paid separately) as shown in electrical plate No 1 complete all as specified and as directed. |
| 11 | Material & labourof PCC 1:3:6 type C-2 using 20 mm graded stone aggregate in mass concrete and filling completefor foundation/hard standing coping ,complete all as specified and directed. |
| 12 | Material & ,labourin replacement of UNSV Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed with and including two coataluminium paint over a coat ofred oxide primer complete all as specified and directed. |
| 13 | Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed. Make:Havells/GLOSTER/Polycab) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately ) |
| 14 | 25 Sqmm 3½ core. |
| 15 | 35 Sqmm 3½ core |
| 16 | 50 Sqmm 3½ core |
| 17 | 70 Sqmm 3½ core |
| 18 | 95 Sqmm 3½ core |
| 19 | 120 Sqmm 3½ core |
| 20 | 150 Sqmm 3½ core |
| 21 | 185 Sqmm 3½ core |
| 22 | 240 Sqmm 3½ core |
| 23 | 300 Sqmm 3½ core |
| 24 | Re-laying LT cable Obtained form Item No 13.01 to 13.10 (Any size any core) complete all as specified and directed. |
| 25 | M & L for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed. |
| 26 | Supply & fixing inreplacement pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 100mm height and 65mm dia suitable for working pressure upto and including 1100 volts LT line fixed on poles grade complete all as specified and directed |
| 27 | Supply and fixing inreplacement shackle type porcelain vitreous, white, brown or green insulator for working pressure 1100V of 115mm dia and 100mm high including galvanized mild steel strip 31 x 3mm, insulator bolts 14mm dia washer and nutfor LT lines fixed on poles. complete all as specified and directed. |
| 28 | Restringing of HT/LT/street light over head linesof existing over head line of ACSR conductor /GI wire after disconnecting from the insulators & jumpers to the required tension & sag & binding up & connecting to insulators & jumpers properly testing complete, including chopping off tree branches (coming in the way line) complete all as specified and directed Note: For item No 17(a) Trimming of tree branches up to 1.5 RM from the conductor deemed to be inclusive in the unit rate. (b)Single conductor shall be considered for measurement in RM. |
| 29 | M&L in replecement of UNSVLTPVC separator 4 wire complete all as specified and as directed. |
| 30 | M&L in replecement of UNSVLTPVC separator 2 wire complete all as specified and as directed. |
| 31 | S&F in replacement aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified & directed. |
| 32 | Supplying and fixing inrepair MCCB, 630 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu100% = 35/36 KA with adjustable thermal & magnetic setting, of Make : Legrand/Indo Asian/Schnieder/Havells Cat No-IHLLSECF0630 |
| 33 | Supplying and fixing inrepair MCCB, 400 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Ics = 100% of Icu 35/36 kA with adjustable thermal & magnetic setting, of Make : Legrand/Indo Asian/Schnieder/Havells Cat No-IHLLSECF0400 |
| 34 | Supplying and fixing inrepair MCCB, 250 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 35/36 kA with adjustable thermal & magnetic setting, ofMake : Legrand/Indo Asian/Schnieder / L&T / Havells Cat No-IHLLSECF0250 |
| 35 | Supplying and fixing inrepair MCCB, 200 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 35/36 kA with adjustable thermal & magnetic setting, of Make : Legrand/Indo Asian/Schnieder / L&T / Havells Cat No-IHLLSECF0200 |
| 36 | Supplying and fixing inrepair MCCB, 100 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu = 25 kA with fixed thermal & magnetic setting, of Make : Legrand/Indo Asian/Schnieder / L&T |
| 37 | Supplying, fixing, inrepair testing and commissioning in replacement of front operated ON Load type changeover switch 4 pole, 415 volts, 125 Amps with and including sheet enclosurecomplete all as specified and directed.Cat part No:IHCNFO0125 of make Havells or equivalent in Legrand/Indo Asian/Schnieder / L&T |
| 38 | Supplying, fixing, inrepair testing and commissioning in replacement ofof front operated ON Load type changeover switch 4 pole, 415 volts, 200 Amps without sheet enclosure complete all as specified and directed.Cat part No:IHCNFO0200 of make Havells orMake Indo Asian equivalent in Legrand/Indo Asian/Schnieder / L&T |
| 39 | Supplying, fixing, inrepair testing and commissioning in replacement of of side operated OFF Load type changeover switch 4 pole, 415 volts, 400 Amps with and including sheet enclosurecomplete all as specified and directed. Cat part No:IHBFFE0400 ofmake Havells or equivalent in Legrand/Indo Asian/Schnieder / L&T |
| 40 | Supplying, fixing, inrepair testing and commissioning in replacement of of side operated OFF Load type changeover switch 4 pole, 415 volts, 630 Amps with and including sheet enclosurecomplete all as specified and directed. Cat part No:IHBFFE0630 ofmake Havells or equivalent in Legrand/Indo Asian/Schnieder / L&T |
| 41 | Material and labour for cleaning and preparation of all existing steel surfaces of straight steel tubular poles 9 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying one coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of pole including writing pole No and other sign works with white paint over black painted base in the pattern and style as approved by the Engineer-in-Charge complete all as specified & directed.Note : Size of black painted base for numbering shall be 100mmx25mm and the size of numbers shall be not exceeding 10cm height. |
| 42 | Supplying, fixing, testing and commissioning of UNSV LT panel board outdoor factory made kiosk cubical type, dust & vermin proof CPRI approved of suitable size (1.1x1.40x0.50) Ip class protectionmade of 3 mm thick CRCA sheet andangle iron50x50x6mmframe including two coats of enamel paint over a coat of redoxide primer complete with locking arrangement mounted on PCC Plat form 100 mm thick made out of PCC 1:3:6,100 mm thick, 1 Mtr all round the panel board complete with the following items:-(a) Aluminium Bus bar 400 Amps capacity TPN, full for phase and half for neutral with colour code PVC sleeves. - 01 Job(b) Digital volt meter to read up to 500 volts with built-in-selector switch.(c) Digital Amp meter to read up to 200 Ampswith CTs and built in selector switchRYB indicating lamps – 01 set (d) ON Load type changeover switch 4 pole, 415 volts, 400 Amps without sheet enclosure complete - 01 No (In comming)(e) MCCB TP, 415 Volts, 400 Amps, 35 KAbreaking capacity with adjustable 70%-100%, magnetic setting 5-10 times - 01 No (In comming)(f) MCCB TP, 415 Volts, 250 Amps, 35 KA breaking capacity with fixed type, magnetic fixed type- 01 Nos (Out going).(g) MCCB TP, 415 Volts, 200 Amps, 35 KA breaking capacity with fixed type, magnetic fixed type - 01 Nos (Out going).(h) MCCB TP, 415 Volts, 100 Amps, 25 KA breaking capacity with fixed type, magnetic fixed type - 01 Nos (Out going).(j) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job(k) Interconnection of busbar with MCCB, SFUs, contactor with suitable size aluminium strip - 01 Job(l) Provisioning of cable glands and cable lugs for all incoming and out going cables - 1 Job |
| 43 | Note:-for item No. 30(i)The contractor shall submit proposed drawing of the panel interlia mentioning make of switchgears to be incorporated alongwith name of panel manufactrer for approval of GE before manufacturing.(ii)The quoted rate is inclusive of the cost of danger notice plate ofsuitable size and marking of letters with PVC sheet/ Stickers such as incoming and outgoing and capacity of breakers etc.(iii) The cost of fixing of the panel on suitable PCC(1:3:6) type C-1 (using 20mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the Contractor for the above item.(v)The bottom of panel shall have minimum 45cm height from existing ground/floor level. |
| 44 | Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 50 mm long medium weight mild steel butt hinges in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed (Note :- Each hinge point shall be measured as one unit. ) |
| 45 | Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100 mm long medium weight mild steel butt hinges in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed (Note :- Each hinge point shall be measured as one unit. ) |
| 46 | Material, labour,testing and commissioning in replacement of UNSV indication lamp (LED type) with showing red, yellow and green in colour of 22.5 mm dia monitor on LT panel board suitable for 240 V AC supply all as specified and directed. Make : L&T /Binay.or equivalent approved. |
| 47 | Material, labour,testing and commissioning in replacement of UNSV of digital electronic volt meter 0-500 V range suitable for LT 415 Volts panel flush pattern square type 96mmX96mm with adopter complete with button all as specified and directed.Make : ENERCON/AENote :- The rate quoted shall be deemed to including the following:-(i) Control wiring for auxiliary supply 230 Volts AC if required.(ii) Cutting the sheet of the panel to suit with existing panel if required.(iii) Calibration and testing the meter. |
| 48 | Material, labour,testing and commissioning in replacement of UNSV of digital electronic ammeter double ratio with 5 Amps secondary current of any range flush pattern sequence type 96mmX96mm with adopter suitable for existing CT ratiofor maintaining on LT 415 Volts panel complete built in selector switch including taking the old unserviceable Ammeterall as specified and directedMake : ENERCON/AE.Note :- The rate quoted shall be deemed to including the following :-(i) Control wiring for auxiliary supply 230 Volts AC if required.(ii) Cutting the sheet of the panel to suit with existing panel if required.(iii) Calibration and testing the meter. |
| 49 | Supplying, Fixing, jointing and testing for provision of straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cablesall as specified and directed. MAKE : M.SEAL/DENSON/ MAHINDRA CHEMICALS/3M) :- |
| 50 | 50 Sqmm 3½ core |
| 51 | 70 Sqmm3½ core |
| 52 | 95 Sqmm 3½ core |
| 53 | 120 Sqmmto150 Sqmm 3½ core |
| 54 | 185 Sqmm 3½ core |
| 55 | S& F in replacement of UNSV lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop retuning, filling & making cable lead by providing Aluminium lugs lead including crimping with crimping tools in the existing LT cable including necessary connection etc complete all as specified and directed |
| 56 | Up to 50 Sq mm |
| 57 | From 70 Sq mm to 120 Sq mm |
| 58 | From 150 to 185 Sq mm |
| 59 | From 240 to 300 Sq mm |
| 60 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead 32X 6 mm GI strip, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No . 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh incl necessary excavation and earth work in any type of soil, and PCC (1: 3 : 6) type C-1 (using 20 mm graded black trap/ granite/ Basalt stone aggregate) for earth pitwith 40x40x6 mm mild steel angle iron frame for cover and 40 mm thick precastRCC cover in 1 : 2 : 4 type B1(using 20 mm graded black trap/granite/ basalt stone aggregate) with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle, completeall as specified & directed . |
| 61 | Material and labour in replacement of UNSV GI strip of size 32mm x 6mm for laying along the wall/roof on batten or burried in ground or drawn in conduit pipe or fixed to poles or any other situation as directed or as required GI strip of size 32mm x 6mm earth continuity conductor complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor all as specified and directed. |
| 62 | Material and labour in replacement of UNSV GI strip of size 4mm dia galvansed iron or steel wire for laying along the wall/roof on batten or burried in ground or drawn in conduit pipe or fixed to poles or any other situation as directed or as required GI wire of size 4mm dia galvansed iron or steel wire earth continuity conductor complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor all as specified and directed. |
| 63 | M & L for PCC 1:2:4 type B2 with 40mm grade stone aggregate as in foundation for outstanding around pole near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete, all as specified and directed. |
| 64 | M&L for PCC 1:4:8 type D2 with 40 mm graded stone aggregate as in foundation for hard standing aroundpole& near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete, all as specified and directed. |
| 65 | Supply & fix of HT/LT UG Cable Route indicators of MS plate size 200mmX150mm & 3 mm thick mounted on 10 mm dia steel rod of length 800 mm etc complete all as specified and directed by Engineer-in-Charge. |