| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-11-2024 | CORRIGENDUM-XVIII | Date | 05-12-2024 |
| 2 | 22-11-2024 | CORRIGENDUM-XVII | Date | 28-11-2024 |
| 3 | 11-11-2024 | CORRIGENDUM-XVI | Date | 21-11-2024 |
| 4 | 04-11-2024 | CORRIGENDUM-XV | Date | 11-11-2024 |
| 5 | 24-10-2024 | CORRIGENDUM-XIV | Date | 04-11-2024 |
| 6 | 17-10-2024 | CORRIGENDUM-13 | Date | 24-10-2024 |
| 7 | 05-10-2024 | CORRIGENDUM-12 | Date | 17-10-2024 |
| 8 | 30-09-2024 | CORRIGENDUM-XII | Date | 07-10-2024 |
| 9 | 23-09-2024 | CORRIGENDUM-X | Date | 30-09-2024 |
| 10 | 16-09-2024 | CORRIGENDUM-IX | Date | 23-09-2024 |
| 11 | 09-09-2024 | CORRIGENDUM-VIII | Date | 16-09-2024 |
| 12 | 02-09-2024 | CORRIGENDUM-VII | Date | 09-09-2024 |
| 13 | 26-08-2024 | CORRIGENDUM-VI | Date | 02-09-2024 |
| 14 | 19-08-2024 | CORRIGENDUM-V | Date | 26-08-2024 |
| 15 | 12-08-2024 | CORRIGENDUM-IV | Date | 19-08-2024 |
| 16 | 05-08-2024 | CORRIGENDUM-III | Date | 12-08-2024 |
| 17 | 29-07-2024 | CORRIGENDUM-II | Date | 05-08-2024 |
| 18 | 22-07-2024 | CORRIGENDUM-1 | Date | 29-07-2024 |
| 19 | 03-07-2024 | ERROR-WITH-DSC | Date | 22-07-2024 |
| Sl. No. | Item Description |
| 1 | INSTRUMENTATION |
| 2 | PRESSURE GAUGES AND ACCESSORIES(Excl. supply of Impulse pipe/Tubing materials) |
| 3 | Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Over-range Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply and erection of supports/ tray, mounting on support (if support required), laying of capillary on tray, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, Piping material and Calibration. |
| 4 | In Carbon Steel as per Standard 7-52-1210 |
| 5 | In Carbon Steel as per Standard 7-52-1216 |
| 6 | In Stainless Steel as per Standard 7-52-0432/1112 |
| 7 | In Carbon Steel as per Standard 7-52-1223 |
| 8 | In Carbon Steel as per Standard 7-52-1224 |
| 9 | In Carbon Steel as per Standard 7-52-1225 |
| 10 | In Carbon Steel as per Standard 7-52-1228 |
| 11 | In Carbon Steel as per Standard 7-52-1229 |
| 12 | In Carbon Steel as per Standard 7-52-1230 |
| 13 | In Carbon Steel as per Standard B269-7-52-1232 |
| 14 | In Carbon Steel as per Standard B269-7-52-3133 |
| 15 | In Carbon Steel as per Standard B269-7-52-3138 |
| 16 | In Carbon Steel as per Standard B269-7-52-3144 |
| 17 | In Carbon Steel as per Standard B269-7-52-3146 |
| 18 | In Carbon Steel as per Standard B269-7-52-3150 |
| 19 | In Carbon Steel as per Standard B269-7-52-3153 |
| 20 | In Carbon Steel as per Standard B269-7-52-3156 |
| 21 | In Alloy Steel as per Standard 7-52-1225 |
| 22 | In Alloy Steel as per Standard 7-52-1226 |
| 23 | In Alloy Steel as per Standard 7-52-1210 |
| 24 | In Alloy Steel as per Standard B269-7-52-3133 |
| 25 | In Alloy Steel as per Standard B269-7-52-3138 |
| 26 | VARIABLE AREA FLOWMETERS |
| 27 | Installation of integral/ remote Transmitters for Variable Area Flowmeter including mounting on Instrument/ yoke (if required), laying and termination of interconnection cables with supports for cables as necessary and painting of supports but exclusive of Supply of Instrument, yoke and Calibration. |
| 28 | Installation of transmitter for Variable Area Flowmeter Transmitters |
| 29 | CORIOLIS MASS FLOWMETERS |
| 30 | Installation of Transmitters/ Preamplifiers on Yoke/ Instrument (if required), including laying and termination of inter connection cables with supports for cables, painting of supports but exclusive of Supply of Instrument, Yoke and Calibration. |
| 31 | Installation of Transmitters/ Preamplifiers for Coriolis Mass Flowmeters |
| 32 | VORTEX FLOWMETERS |
| 33 | Installation of integral/ remote transmitters/ Preamplifier for Vortex flowmeter on yoke/ instrument including laying and termination of interconnection cables with supports as necessary and painting of supports but exclusive of Supply of Instrument, yoke and Calibration. |
| 34 | Installation of Transmitters/ Preamplifiers for Vortex Flowmeters |
| 35 | ULTRASONIC FLOWMETER |
| 36 | Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. |
| 37 | Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters |
| 38 | DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Excl. supply of Impulse pipe/Tubing material) |
| 39 | Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Piping material, all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 40 | In Carbon Steel as per Standard 7-52-1566 |
| 41 | In Alloy Steel as per Standard 7-52-1541 |
| 42 | In Alloy Steel as per Standard B269-7-52-3508 |
| 43 | In Carbon Steel as per Standard B269-7-52-3508 |
| 44 | In Carbon Steel as per Standard B269-7-52-3517 |
| 45 | In Stainless Steel as per Standard 7-52-1541 |
| 46 | In Stainless Steel as per Standard 7-52-3518 |
| 47 | SPECIAL LEVEL/ GUIDED WAVE / ECCLIPSE TYPE RADAR LEVEL INSTRUMENTS |
| 48 | Installation of Guided Wave/ Ecclipse type radar level instruments with or without controllers including installation of instruments on nozzles, changing of head orientation wherever required, fabrication and installation of primary piping, drain valve / vent valve assembly as per standard and hydraulic testing of instrument but exclusive of supply of instruments, piping materials, all electrical/ pneumatic connections and calibration. |
| 49 | In Carbon Steel as per Standard 7-52-0475/1553 |
| 50 | In Alloy Steel as per Standard B269-7-52-3502 |
| 51 | In Alloy Steel as per Standard B269-7-52-3506 |
| 52 | In Stainless Steel as per Standard B269-7-52-3506 |
| 53 | In Carbon Steel as per Standard B269-7-52-3506 |
| 54 | MAGNETIC LEVEL GAUGES |
| 55 | Installation of Magnetic Level Gauges on Vessel/ Piping/ Stand pipes with minor modification wherever required, providing intermediate supports wherever necessary fabrication and installation of drain valve/ vent valve assembly as per Standard Nos. indicated below, hydraulic testing of gauge, exclusive of Supply of Instruments, Piping materials and Calibration. |
| 56 | In Carbon Steel as per Standard 7-52-0484/1520 |
| 57 | In Stainless Steel as per Standard 7-52-0484/1520 |
| 58 | In Carbon Steel as per Standard B269-7-52-3501 |
| 59 | In Carbon Steel as per Standard B269-7-52-3512 |
| 60 | In Alloy Steel as per Standard B269-7-52-3501 |
| 61 | In Alloy Steel as per Standard B269-7-52-3503 |
| 62 | In Stainless Steel as per Standard B269-7-52-3501 |
| 63 | RF TYPE LEVEL INSTRUMENTS |
| 64 | Installation of RF type level transmitters/ switches as equipment with flanged/ screwed connections, including probe/ rope (as applicable), electronics/ pre-amplifier/ transmitter unit on instrument/ yoke, laying and termination of interconnecting cables, fabrication, and erection of support for interconnecting cables, painting of supports, but exclusive of Supply of all Instruments/ probe/ electronics/ preamplifier/ transmitter, yoke, setting of switches and Calibration. |
| 65 | RF type level instrument |
| 66 | RADAR LEVEL INSTRUMENTS |
| 67 | Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. |
| 68 | Installation of Top Mounted Radar |
| 69 | ULTRASONIC/ CAPACITANCE LEVEL INSTRUMENTS |
| 70 | Installation of ultrasonic/ capacitance probe, screwed/ flanged type connection on equipment nozzle. Installation of electronics units, including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable upto instrument/ probe with clamps, termination of cables at both ends, painting of supports but exclusive of supply of Instruments/ yoke. electronic unit, yoke and Calibration. |
| 71 | Capacitance Level Instruments |
| 72 | PRESSURE INSTRUMENTS(Excl. supply Impulse pipe/Tubing materials) |
| 73 | Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Over-range Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Piping/tubing materials, all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 74 | In Carbon Steel as per Standard 7-52-1143 |
| 75 | In Carbon Steel as per Standard 7-52-1222 |
| 76 | In Alloy Steel as per Standard 7-52-0442/0443/1151/1123 |
| 77 | In Carbon Steel as per Standard 7-52-1224 |
| 78 | In Carbon Steel as per Standard 7-52-1225 |
| 79 | In Carbon Steel as per Standard B269-7-52-1242 |
| 80 | In Carbon Steel as per Standard B269-7-52-3129 |
| 81 | In Carbon Steel as per Standard B269-7-52-3137 |
| 82 | In Carbon Steel as per Standard B269-7-52-3146 |
| 83 | In Carbon Steel as per Standard B269-7-52-3153 |
| 84 | In Carbon Steel as per Standard B269-7-52-3156 |
| 85 | In Alloy Steel as per Standard 7-52-1143 |
| 86 | In Alloy Steel as per Standard 7-52-1224 |
| 87 | In Alloy Steel as per Standard 7-52-1225 |
| 88 | In Alloy Steel as per Standard 7-52-1226 |
| 89 | In Alloy Steel as per Standard B269-7-52-2104 |
| 90 | In Alloy Steel as per Standard B269-7-52-3137 |
| 91 | In Stainless Steel as per Standard 7-52-1143 |
| 92 | In Stainless Steel as per Standard 7-52-1225 |
| 93 | In Stainless Steel as per Standard B269-7-52-2186 |
| 94 | In Stainless Steel as per Standard B269-7-52-3137 |
| 95 | In Stainless Steel as per Standard B269-7-52-3147 |
| 96 | TEMPERATURE INSTRUMENTS |
| 97 | Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. |
| 98 | Temperature Indicator/ Gauges (Filled System) with thermowell on flanged wells |
| 99 | Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells |
| 100 | Test Thermowell (flanged) |
| 101 | TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) |
| 102 | Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. |
| 103 | Temperature Transmitter and Thermocouple with flanged well |
| 104 | Temperature Transmitter only |
| 105 | HEATER SKIN THERMOCOUPLES |
| 106 | Installation of Heater Skin Thermocouple as per recommended orientation including remote mounted head, if required, on yoke, fabrication and erection of supports, painting of supports but exclusive of Supply of Instruments, welding of thermocouple knife-edge/ pad and retaining clamp on to the water tube, all Electrical connections and Calibration. |
| 107 | Heater Skin Thermocouples |
| 108 | INSTALLATION OF SURGE PROTECTORS IN FIELD EQUIPMENT |
| 109 | Installation of Surge protector |
| 110 | Installation of Surge protector |
| 111 | INSTALLATION OF WIRELESS REPEATERS/ GATEWAYS/ ANTENNA |
| 112 | Installation of wireless repeaters/gateways/ antenna on yoke but exclusive of supply of wireless repeaters/ gateways/antenna, yoke and calibration. |
| 113 | Installation of wireless repeaters/gateways/ antenna on yoke but exclusive of supply of wireless repeaters/ gateways/antenna, yoke and calibration. |
| 114 | DIFFERENTIAL PRESSURE INSTRUMENTS (Excl. supply of Impulse pipe/Tubing materials) |
| 115 | Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch (including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, Piping material, all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 116 | In Stainless Steel as per Standard B269-7-52-3309 |
| 117 | In Alloy Steel as per Standard B269-7-52-2114 |
| 118 | In Alloy Steel as per Standard B269-7-52-3309 |
| 119 | In Carbon Steel as per Standard B269-7-52-2100 |
| 120 | In Carbon Steel as per Standard B269-7-52-2114 |
| 121 | In Carbon Steel as per Standard B269-7-52-2167 |
| 122 | In Carbon Steel as per Standard B269-7-52-3154 |
| 123 | ANALYZERS AND GAS CHROMATOGRAPH |
| 124 | Installation of pH Analyzer of submersion type probe/ flow thru type probe/retractable type probe with sampling system consisting of pressure reducing valve, safety valve, needle valve etc. (duly mentioned in a box /plate/ rack), sample cell (Electrode assembly) and preamplifier/ transmitter mounted on Yoke including installation of cell, sampling system, preamplifier/ transmitter, interconnecting tubing and cabling between cell and sampling system/transmitter, interconnection of all cables and tubes/pipes, supply, fabrication and erection of supports impulse line/ interconnecting cables etc. and hydraulic testing, painting of supports but exclusive of Supply of Analyzer and its accessories, all interconnecting Piping/ Tubing, Calibration and Testing. |
| 125 | pH analyser installation - Flow through type |
| 126 | Installation of Water Quality Analyzer including sample cell with sampling system, pressure reducing valve, pressure relief valve, needle valve etc., and transmitter/ preamplifier with/ without pre-assembled assembly on yoke/ fabricated each including installation/ assembly of cell, sampling system, preamplifier/ transmitter, interconnecting tubing/ piping and cabling, laying and interconnection of all cables/ tubes/ pipes, fabrication and installation of manifolds/ impulse lines with supports, supply and installation of supports for impulse lines, hydraulic testing of impulse lines, painting of supports but exclusive of Supply of Analyzer and its accessories, all interconnecting Piping/ Tubing materials, all electrical/ Pneumatic connections, yoke/ rack and Calibration. |
| 127 | Installation of Water Quality Analyzer |
| 128 | Installation of analyzer/ Gas Chromatograph with probe, sampling system, calibration bottles and accessories including interconnecting tubing, cabling between probe, analyzer, sampling system and calibration bottles mounted in pre-installed fabricated analyzer cabinet as applicable, interconnection of all cables and tubes, supply, fabrication and erection of support for tubing/ cabling, reinstallation of loose supplied items for the analyzer, but exclusive of Supply of Analyzer and all its accessories, interconnecting Piping/ Tubing materials, Calibration and Testing. |
| 129 | Viscosity Analyser |
| 130 | ANALYZER CALIBRATION |
| 131 | Providing necessary support to the analyser vendor/ supplier round the clock during calibration, testing and commissioning of analysers listed below including removal of analyser as necessary from the preinstalled location and reinstallation back to its original location providing tools as required, Instrument air/ Nitrogen, any other utility, test report and loop testing as per vendor/ manufacturer recommendation and by engineers in charge except supply of analyser specific test equipment and consumables like calibration samples and gas cylinders. |
| 132 | pH Analyzer |
| 133 | Water Quality Analyzer (TOC) |
| 134 | Viscosity Analyser |
| 135 | O2 Analyser- TDLS Type |
| 136 | ANALYZER CABINETS |
| 137 | Installation of prefabricated analyzer cabinets in analyzer room/ field of following sizes including supply, fabrication and installation of base frame grouting and fixing of foundation bolts as necessary, removal and reinstallation of analysers and its accessories like sampling system, racks, air conditioners, vortex cooler, installation of fresh air duct if necessary, connecting all utility lines to the cabinet as required but exclusive of supply of cabinet and analysers, painting of cabinet and calibration. |
| 138 | Volume less than 1m (W) x 1m (D) x 2.5m (H). |
| 139 | Volume less than 1.5m (W) x 1.5m (D) x 2.5m (H) but more than 1m (W) x 1m (D) x 2.5m (H). |
| 140 | Volume less than 2m (W) x 2m (D) x 2.5m (H) but more than 1.5m (W) x 1.5m (D) x 2.5m (H). |
| 141 | DETECTOR SYSTEMS |
| 142 | Installation of Fire and Gas detectors/monitors, beacon lights and hooters including earthing of Fire and Gas detector, supply of supports but exclusive of Supply of Detectors, Yoke and Calibration. |
| 143 | LEL Detectors |
| 144 | Hooters |
| 145 | Open path gas detector with Receiver & Transmitter |
| 146 | H2S Detectors |
| 147 | Beacon Lights |
| 148 | MISCELLANEOUS ITEMS AND DEVICES |
| 149 | Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items, painting of supports but exclusive of Supply of Instrument items, Piping/ Tubing material / Calibration and supply and erection of Yoke support. |
| 150 | Air filter Regulators/ Boosters/ Quick Exhaust Valve/ Air Lock Relays |
| 151 | Volume bottles and accessories like Volume boosters, quick exhaust relay etc. including tubing for Remote Operated Valves/ Control Valves of different sizes. |
| 152 | Limit Switches. |
| 153 | Electronic Local Indicator. |
| 154 | Purge Variable Area Flowmeter (i.e. Purge Rotameter). |
| 155 | Fire Safe blanketing for valves shall also include removing and re-stitching as required but exclusive of supply of fire safe blanket. |
| 156 | Solenoid Valves 3 way/ 4 way/ 5 way with or without manual reset for loose supply only (excluding those mounted on valves). |
| 157 | Position Transmitter. |
| 158 | Corrosion Transmitters |
| 159 | Vibration probes/Transmitter |
| 160 | Installation of Top Mounted Guided Wave Radar |
| 161 | Flame-proof Push Button Station/Selector Switches/Lamps |
| 162 | Current to Pneumatic/ Pneumatic to Current Convertor. |
| 163 | Multi-probe Agar Type Level Instrument |
| 164 | Corrosion Coupons |
| 165 | Solenoid valves with TMR configuration in a box enclosure with Volume less than 1m (W) x 1m (D) x 2.5m (H). |
| 166 | MOUNTING OF INSTRUMENT ITEMS ON PRE- FABRICATED HOOK-UP ASSEMBLY/SKID/ PACKAGES |
| 167 | Installation of pressure gauges/pressure transmitters with or without vent/drain tubing on pre-installed manifold/ Yoke/ Support/ pre-fabricated hook-up assembly/ skid/ packages but exclusive of supply of instruments, installation of pre-fabricated hookup assembly/ manifold/ yoke and calibration of instruments. |
| 168 | Installation of differential pressure gauges/ differential pressure transmitters with or without vent/drain tubing on pre-installed manifold/ Yoke/ Support/ pre-fabricated hook- up assembly/ skid/ packages but exclusive of supply of instruments, installation of pre-fabricated hookup assembly/ manifold/yoke and calibration of instruments. |
| 169 | LOCAL PANELS/ CABINETS/ GAUGE BOARDS |
| 170 | Installation of local panels in field (Pressurized/ Non- pressurized/ Flame- proof) /PLC cabinets/ marshalling cabinets / Radiation Pyrometer monitor / Gas monitor panels/ local gauge board inside control room with or without instruments of following sizes including supply, fabrication, painting and installation of base frames and installation of panel but exclusive of pneumatic/ electrical connections, supplying of local panels/ local gauge boards. |
| 171 | Size 1000x800x600 mm (or smaller volume) |
| 172 | Size < 2200x1000x800 mm > 1000x800x600mm |
| 173 | Installation of panels / cabinet / consoles |
| 174 | Shifting of Cabinets from Site Storage Area/ Warehouse to Control room/SRR as per instructions from Site In-Charge |
| 175 | Size <= 2200x1200x800mm or >= 2200x800x600mm |
| 176 | PANEL/ RACK ITEMS |
| 177 | Mounting of miscellaneous instrument items on panels/ racks etc. as listed below including installation of items, fabrication and erection of supports pneumatic/ electrical connections but exclusive of supply of Instrument items, their setting/ Calibration. |
| 178 | Push Buttons, Selector Switches, Lamps, Bypass Switches |
| 179 | DRAFT GAUGES |
| 180 | Installation of Draft gauges/transmitters with or without weatherproof housing including mounting on Yoke/ Fabricated Panel/ Gauge Board, supply of support for impulse lines, fabrication and installation of manifold/impulse lines with support as per standard indicated below, air testing and painting of supports as per specifications but exclusive of Supply of Instruments, Piping/tubing materials, Yoke, Fabricated Panel/ Gauge Board and Calibration. |
| 181 | In Carbon Steel as per Standard B269-7-52-3141 |
| 182 | In Carbon Steel as per Standard B269-7-52-2186 |
| 183 | CALIBRATION/ TESTING |
| 184 | Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration |
| 185 | Control Valves |
| 186 | On-off valves (SDV/ ROV) |
| 187 | Self Actuated Pressure reducing valves |
| 188 | Cleaning, calibration of the instruments listed below including removal of instrument from reinstalled locations like panels, enclosures, racks, field etc., and fixing them back in respective places, providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. |
| 189 | Pressure gauges |
| 190 | Pressure transmitters |
| 191 | Diaphragm Seal Pressure Transmitters |
| 192 | Differential Pressure Transmitters for Flow, Level and D.P. |
| 193 | Differential Pressure Transmitters, Diaphragm Seal for Flow |
| 194 | Differential Pressure Transmitters, Diaphragm Seal for Level |
| 195 | Diaphragm Seal Pressure Gauges |
| 196 | Differential Pressure Transmitters, Diaphragm Seal for D.P. |
| 197 | Temperature gauges |
| 198 | Temperature Transmitters |
| 199 | Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments |
| 200 | Tank Level Instrument (Radar type) |
| 201 | Draft Gauges |
| 202 | RF Type Level Instruments |
| 203 | Current to Pneumatic convertors |
| 204 | Electronic Local Indicator |
| 205 | Position Transmitter |
| 206 | Speed Transmitter |
| 207 | LEL Detectors |
| 208 | H2S Detectors |
| 209 | HC open Path LEL detector (Transmitter & receiver) |
| 210 | Vibration Transmitters |
| 211 | Multi-probe Agar Type Level Instrument |
| 212 | Corrosion Transmitters |
| 213 | Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. |
| 214 | Coriolis Mass flowmeters |
| 215 | Vortex flowmeters |
| 216 | Ultrasonic flowmeters |
| 217 | Variable Area flowmeter Transmitters |
| 218 | LOOP CHECKING |
| 219 | Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. |
| 220 | Temperature Transmitters |
| 221 | Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments |
| 222 | Tank Level Instruments (Radar type) |
| 223 | Electronic Local Indicator |
| 224 | Gas Detectors |
| 225 | Speed Indicator |
| 226 | Pressure transmitters |
| 227 | RF Type Level Instruments |
| 228 | Diaphragm Seal Pressure transmitters |
| 229 | Position Transmitter |
| 230 | Speed / Vibration Transmitter |
| 231 | Push Button/Selector Switches/Lamps |
| 232 | Hooter / Beacon |
| 233 | Control valve positioner |
| 234 | Miscellaneous Instruments / Transmitters |
| 235 | Corrosion Transmitter |
| 236 | Differential Pressure Transmitters for Flow, Level and D.P. |
| 237 | Differential Pressure Transmitters, Diaphragm Seal for Flow |
| 238 | Differential Pressure Transmitters, Diaphragm Seal for Level |
| 239 | Differential Pressure Transmitters, Diaphragm Seal for D.P. |
| 240 | Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. |
| 241 | Variable Area flowmeter Transmitters |
| 242 | Coriolis Mass flowmeters |
| 243 | Vortex flowmeters |
| 244 | Ultrasonic flowmeters |
| 245 | SUPPLY ITEMS |
| 246 | Supply of Instrument items as per specifications enclosed elsewhere in the Tender. |
| 247 | 1/2 \" GI Conduit |
| 248 | 3/4 \" GI Conduit |
| 249 | 1 \" GI Conduit |
| 250 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIA/IIB |
| 251 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIA/B : ISO M20 x 1/2\" NPT(F) |
| 252 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIC : ISO M16 x 1/2\" NPT(F) |
| 253 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIA/IIB : ISO M20 x 3/4\" NPT(F) |
| 254 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIA/IIB : 1/2\"NPT(M) x 3/4\" NPT(F) |
| 255 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIA/IIB : 1.5\" NPT(M) x 1\" NPT(F) |
| 256 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIA/IIB : 1.5\" NPT(M) x 3/4\" NPT(F) |
| 257 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr.IIA/IIB : 3/4\"NPT(M) x 1/2\" NPT(F) |
| 258 | Weatherproof & Flameproof Adapter for cable gland suitable for Gas Gr. IIA/IIB : 1\"NPT(M) x 1/2\" NPT(F) |
| 259 | Supply of Junction boxes of various types and specifications |
| 260 | Junction Box, Weatherproof + Flameproof (Gas Groups-IIA/IIB) type 3 Way |
| 261 | Junction Box, Weatherproof + Flameproof (Gas Groups - IIA/IIB) type for 12 Pair Cable |
| 262 | Junction Box, Weatherproof + Flameproof (Gas Groups - IIA/IIB) type for 8 Triad Cable |
| 263 | Junction Box, Weatherproof + Flameproof (Gas Groups - IIA/IIB) type for 6 Pair Cable |
| 264 | Junction Box Weatherproof + Flameproof (Gas Groups - IIA/IIB) for 2 Core X 50/70 mm2 Power Cable including double compression type cable glands of Ni plated Brass material for incomer and outgoing cables. |
| 265 | Junction Box Weatherproof + Flameproof (Gas Groups - IIA/IIB) for 2 Core X 10/16/35 mm2 Power Cable including double compression type cable glands of Ni plated Brass material for incomer and outgoing cables. |
| 266 | Junction Box Weatherproof + Flameproof (Gas Groups - IIA/IIB) for 2 Core x 4/6 mm2 Power Cable including double compression type cable glands of Ni plated Brass material for incomer and outgoing cables. |
| 267 | Supply of Cable glands of various types and specifications |
| 268 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1 1/4\" NPTM |
| 269 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1 1/2\" NPTM |
| 270 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1\" NPTM |
| 271 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1/2\" NPTM |
| 272 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 3/4\" NPTM |
| 273 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1 1/2\" ET with check nut |
| 274 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1 1/4\" ET with check nut |
| 275 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 1\" ET with check nut |
| 276 | Double compression type Cable gland, weatherproof + Flameproof (Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, 3/4\" ET with check nut |
| 277 | Double compression type Cable gland, weatherproof + Flameproof ( Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, M20 |
| 278 | Double compression type Cable gland, weatherproof + Flameproof ( Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, M25 |
| 279 | Double compression type Cable gland, weatherproof + Flameproof ( Gas Group IIA/IIB) type, Ni plated Brass material with PVC shroud, M32 |
| 280 | Supply of plugs for cable entries of various types and specifications |
| 281 | Plug, weatherproof + flameproof (Gas Group IIA/IIB) type, Ni plated Brass material material, 1 1/2\" NPTM |
| 282 | Plug, weatherproof + flameproof (Gas Group IIA/IIB) type, Ni plated Brass material material, 1\" NPTM |
| 283 | Plug, weatherproof + flameproof (Gas Group IIA/IIB) type, Ni plated Brass material material, 3/4\" NPTM |
| 284 | Plug, weatherproof + flameproof (Gas Group IIA/IIB) type, Ni plated Brass material material, 1/2\" NPTM |
| 285 | Plug, weatherproof + flameproof (Gas Group IIC) type, SS 304 material, 1 1/4\" NPTM |
| 286 | Supply of compression tube fittings in Stainless Steel of various types and specifications |
| 287 | Male Connector: Material: SS-316 : Size: 1/2\" NPTM X 1/2\" OD 153 Bar |
| 288 | Male Connector: Material: SS-316 : Size: 1/4\" NPTM X 1/2\" OD 153 Bar |
| 289 | Female Connector: Material: SS-316 : Size: 1/2\" NPTM X 1/2\" OD 153 Bar |
| 290 | Tube Union: Material: SS-316 ; Size: 1/2\" OD x 1/2\" OD 153 Bar |
| 291 | Tube Cap; Material: SS-316 ; Size : 1/2\" OD 153 Bar |
| 292 | SS 316 Ball Valve 1/2\" NB OD 41 Bar |
| 293 | 6 Way Air Manifold SS316 |
| 294 | 12 Way Air Manifold SS316 |
| 295 | SS Tubing plug 1/2\" OD SS316 , 153 Kg/CM2 |
| 296 | Supply of compression tube fittings in Brass of various types and specifications |
| 297 | Female Connector : Material: Brass : Size: 1/2\" NPTF X 3/8\" OD , 80 bar |
| 298 | Union Tee: Material: Brass ; Size: 3/8\" OD x 3/8\" OD x 3/8\" OD, 80 bar |
| 299 | Tube Union ; Material: Brass ; Size: 3/8\" OD x 3/8\" OD, 80 bar |
| 300 | Supply of instrument tubes of different types and specifications |
| 301 | Bare Copper tube 3/8\" OD, 1 MM THK , 80 bar |
| 302 | SS316L tube 1/2\" OD 153 Bar |
| 303 | JUNCTION BOX INSTALLATION |
| 304 | Installation of weatherproof and flameproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG GI wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings. |
| 305 | For cable size 6P x 0.5/1.0/1.5/2.5 mm²/16 AWG Signal/FF/Alarm/ Control |
| 306 | For cable size 8T x 1.5/ 2.5 mm² RTD/ Gas Detector |
| 307 | For cable size 12P x 0.5/1.0/1.5/2.5 mm²/16 AWG Signal/FF/Alarm/ Control |
| 308 | Installation of weatherproof and flameproof three way junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG GI wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings. |
| 309 | For cable joining, suitable for cable size 1P x 1.5 mm² Signal/ Alarm/ Control |
| 310 | Installation of weatherproof and flameproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG GI wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings. |
| 311 | For cable size 2C x 2.5 mm² |
| 312 | For cable size 2C x 10 mm² |
| 313 | For cable size 2C x 16 mm² |
| 314 | For cable size 2C x 4 mm² |
| 315 | LAYING OF CABLES |
| 316 | Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if required through IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. |
| 317 | Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² |
| 318 | Fieldbus Cable of Size 1 Pair x 16 /18 AWG |
| 319 | Special armoured serial link MODBUS TCP/IP/RS485 Serial/ cable |
| 320 | Fieldbus Cable of Size 2 Pair x 16 /18 AWG |
| 321 | Signal/ Alarm/ Control Cables of cable sizes 12C / 6P x 1.5 / 2.5 mm² |
| 322 | Signal / Alarm / Control Cables of cable sizes 2P x 1.5 / 2.5 mm² |
| 323 | Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5 mm² |
| 324 | Laying of thermocouple/ RTD/ LEL Detector/ H2S Detector cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs {Instrument Road Crossings}) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/drain/communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/angle tray and preparation of cable trench. |
| 325 | 1 Pair / 2 Pair x 16/20 AWG Thermocouple Cable |
| 326 | 1 Triad/ Quad x 1.5 mm² RTD/ LEL Cable |
| 327 | 8 Triad/ Quad x 1.5 mm² RTD/ LEL Cable |
| 328 | 1 Triad/ Quad x 2.5 mm2 RTD/ LEL Cable |
| 329 | 8 Triad/ Quad x 2.5 mm² RTD/ LEL Cable |
| 330 | 2 Triad/ Quad x 1.5 mm² RTD/ LEL Cable |
| 331 | Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench |
| 332 | For cable size 2C x 4 mm² |
| 333 | For cable size 2C x 50 mm² |
| 334 | For cable size 2C x 70 mm² |
| 335 | For cable size 2C x 95 mm² |
| 336 | For cable size 2C x 6 mm² |
| 337 | For cable size 2C x 10 mm² |
| 338 | For cable size 2C x 16 mm² |
| 339 | For cable size 2C x 2.5 mm² |
| 340 | For cable size 2C x 25 mm² |
| 341 | For cable size 2C x 35 mm² |
| 342 | Laying of Fibre Optic cables with or without HDPE conduit |
| 343 | Laying of Fibre Optic / system cables on ducts, main trays, perforated trays, angle trays, trenches ( including through Instrument Road Crossing) including opening of cable duct covers if required, clamping, glanding the cables, termination at both ends including shields , providing and fixing of identifying tags and testing but exclusive of supply of fibre Optic/System cables and erection of ducts, main trays, perforated trays,/angle trays and preparation of cable trench. |
| 344 | Laying of FO/system cables of various sizes upto 30mmOD |
| 345 | Laying of FO/system cables of various sizes upto 30mm OD along with HDPE conduits of 40 mm OD but exclusive of supply of HDPE conduits. |
| 346 | Termination / splicing of OFC within room at LIU through patch chords and connectors after looping in a Loop box including earthing, OFC site acceptance testing all complete as per specification. |
| 347 | Termination / splicing of OFC at field through patch chords and connectors including earthing, OFC site acceptance testing all complete as per specification. |
| 348 | SAND FILLING IN TRENCHES |
| 349 | Supply of sand and filling of concrete cable trenches with sand after cable laying is completed including levelling of sand and fixing back of precast concrete slabs on the trench. |
| 350 | Trench size 2400 mm (W) x 1500 mm (D) |
| 351 | EARTHING |
| 352 | Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. |
| 353 | At both ends of earth grid/ Instruments of GI wire (12 AWG) in trays and conduits as required excluding earth- pit preparation and electrode installation. |
| 354 | For earthing cable upto 50 mm² size with PVC insulation. |
| 355 | PIPING / TUBING / FABRICATION WORK |
| 356 | Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard |
| 357 | For size 1\" |
| 358 | Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray |
| 359 | 1/2\" / 12 mm O.D . (for SS tubes) |
| 360 | Up to 3/4\" O.D. (for analyzers in SS tubes) |
| 361 | Laying of copper tube for steam tracing of Instruments, primary impulse lines with steam traps/valve accessories including clamping, supply of clamps termination at both ends, providing and fixing metallic tags and hydraulic testing as per Standard given below but exclusive of supply of tube/ fitting and insulation as per standards |
| 362 | For sizes 3/8\"/ 10 mm |
| 363 | Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards |
| 364 | 7-52-1906 (Tubing hook - up control valve with smart / FFpositioner - 1/2 inch OD) |
| 365 | 7-52-1908 (Tubing hook - up control valve with smart positioner with sov -1/2 inch OD) |
| 366 | Supply & wrapping with sodium silicate inhibited ceramic fiber rope (SS-wire braided) after cleaning the impulse lines of dust, rust, grease. The wrapping of the rope around impulse line shall cover it completely without leaving any gap. Apply two layers of self-adhesive Aluminum foil tape of minimum 0.1 mm thick spirally bound over the fiber rope surface with the joints in two layers staggered with all other specifications inline with specification \"6-44-0002\" for Hot insulation |
| 367 | 1/2\" impulse line (with 3/8\" tracer) |
| 368 | 3/4\" impulse line (with 3/8\" tracer) |
| 369 | 3\" impulse line (with 3/8\" tracer) |
| 370 | Erection of SS Air distribution manifold and fittings including supply/ fabrication/ erection of supports, pneumatic testing and painting of supports but exclusive of supply of SS Air distribution manifold and fittings |
| 371 | Installation of 12-way Air Manifold (1/2\") as per Standard7-52-1904 |
| 372 | Installation of 6-way Air Manifold (1/2\") as per Standard 7-52-1905 |
| 373 | DRILLING AND THREADING OF BLIND FLANGES |
| 374 | Making of 1/2\" screwed connections on 1-1/2\" blind flanges of specified materials/ratings, by drilling holes and tapping |
| 375 | In Carbon Steel, 150# flange |
| 376 | In Carbon Steel, 300# flange |
| 377 | In Carbon Steel, 600# flange |
| 378 | In Stainless Steel, 150# flange |
| 379 | In Stainless Steel, 300# flange |
| 380 | In Stainless Steel, 600# flange |
| 381 | In Alloy Steel, 300# flange |
| 382 | In Alloy Steel, 150# flange |
| 383 | In Alloy Steel, 600# flange |
| 384 | Making of 1/2\" screwed connections on 2\" blind flanges of specified materials/ ratings, by drilling holes and tapping |
| 385 | In Carbon Steel 150# flange |
| 386 | In Carbon Steel 300# flange |
| 387 | In Alloy Steel 300# flange |
| 388 | In Carbon Steel 600# flange |
| 389 | In Stainless Steel 150# flange |
| 390 | In Stainless Steel 300# flange |
| 391 | In Stainless Steel 600# flange |
| 392 | In Alloy Steel 150# flange |
| 393 | In Alloy Steel 600# flange |
| 394 | Making of 3/4\" screwed connections on 2\" blind flanges of specified materials/ ratings, by drilling holes and tapping |
| 395 | In Alloy Steel 300# flange |
| 396 | In Carbon Steel 300# flange |
| 397 | In Carbon Steel 600# flange |
| 398 | In Staineless Steel 300# flange |
| 399 | Making of 1/2\" screwed connections on 3\" blind flanges of specified materials/ ratings, by drilling holes and tapping |
| 400 | In Carbon Steel 150# flange |
| 401 | In Alloy Steel 300# flange |
| 402 | In Carbon Steel 300# flange |
| 403 | In Carbon Steel 600# flange |
| 404 | In Stainless Steel 150# flange |
| 405 | In Stainless Steel 300# flange |
| 406 | In Stainless Steel 600# flange |
| 407 | In Alloy Steel 150# flange |
| 408 | In Alloy Steel 600# flange |
| 409 | Making of 3/4\" screwed connections on 3\" blind flanges of specified materials/ ratings, by drilling holes and tapping |
| 410 | In Carbon Steel , 600# flange |
| 411 | FABRICATION WORKS |
| 412 | Fabrication of Siphons / Condensate pots as per drawing attached with following material including supply of pipes etc. |
| 413 | Syphon - Carbon steel |
| 414 | Syphon - Stainless steel |
| 415 | Fire protection of instrument cable duct/trays |
| 416 | Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender |
| 417 | Run of Duct 1200mm(W) X 400mm(H) |
| 418 | Run of Duct 800mm(W) X 300mm(H) |
| 419 | Run of Duct 600mm(W) X 300mm(H) |
| 420 | Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender |
| 421 | Run of Tray 300mm (W) x 40mm (H) |
| 422 | Run of Tray Angle tray of size 50 mm X 50mm X 6mm |
| 423 | Run of Tray 60mm (W) x 40mm (H) |
| 424 | STRUCTURAL |
| 425 | Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. |
| 426 | Run of Duct 1200mm (W) X 400mm (H) |
| 427 | Run of Duct 600mm (W) X 300mm (H) |
| 428 | Run of Duct 800mm (W) X 300mm (H) |
| 429 | Supply, fabrication and installation of of Galvanized Iron ladder tray and its supports as per drawing including bends, tees and elbows, fabricated from 75 mm x 75 mm x 6 mm Galvanized Iron Angle with 50 mm (W) x 6 mm thick Galvanized Iron flat including supply and installation of supports and painting of supports as per specifications. |
| 430 | Run of ladder tray 600mm width |
| 431 | Supply, fabrication and erection of angle / channel trays fabricated out of GI angle as per drawing including supply, fabrication and erection of its supports and painting as per painting standard attached including supply of paint. |
| 432 | Tray of 50x 50 x 6mm angle |
| 433 | Supply and erection of prefabricated Anodised Aluminium perforated trays and its supports including tees, bends and elbows , painting of supports including supply of supports,paint as per painting specifications |
| 434 | Tray of 60mm (W) x 40mm (H) with cover |
| 435 | Tray of 150mm (W) x 40mm (H) with cover |
| 436 | Tray of 300mm (W) x 40mm (H) with cover |
| 437 | GENERAL SITE WORK |
| 438 | Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box, local panel /cabinet etc. for mounting on the stanchion and alignment. |
| 439 | Canopy for local instruments,transmitters |
| 440 | Canopies for temperature elements |
| 441 | Canopies for push buttons |
| 442 | Canopy for Junction Boxes |
| 443 | Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box, local panel /cabinet etc. on the stanchion and alignment. |
| 444 | Canopies for local instruments, transmitters |
| 445 | Canopies for local temperature elements |
| 446 | Canopies for push buttons |
| 447 | Canopy for Junction Boxes |
| 448 | DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS Excl. supply of Impulse pipe/Tubing material) |
| 449 | Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, Piping material, all Electrical/ Pneumatic connections, Yoke and Calibration. |
| 450 | In Carbon Steel as per Standard 7-52-1305 |
| 451 | In Stainless Steel as per Standard 7-52-1305 |
| 452 | In Alloy Steel as per Standard 7-52-1305 |
| 453 | In Alloy Steel as per Standard B269-7-52-3303 |
| 454 | In Alloy Steel as per Standard B269-7-52-3312 |
| 455 | In Carbon Steel as per Standard B269-7-52-1416 |
| 456 | In Carbon Steel as per Standard B269-7-52-1468 |
| 457 | In Carbon Steel as per Standard 7-52-1520 |
| 458 | In Carbon Steel as per Standard B269-7-52-3301 |
| 459 | In Carbon Steel as per Standard B269-7-52-3303 |
| 460 | In Carbon Steel as per Standard B269-7-52-3306 |
| 461 | In Carbon Steel as per Standard B269-7-52-3310 |
| 462 | In Carbon Steel as per Standard B269-7-52-3312 |
| 463 | In Stainless Steel as per Standard B269-7-52-3303 |
| 464 | GENERAL SITE WORK |
| 465 | Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. |
| 466 | 2\" Yoke supports as per standard 7-52-0101 |
| 467 | Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in- Charge. |
| 468 | Identification of instrument items |
| 469 | Removal and remounting of accessories of control valves including removal of positioners, solenoid valves, tubing, limit switches and other accessories at store, tagging the components/ accessories/ bunching/ tying and handing over to owner\"s store for safe custody, refixing/ remounting of all accessories like positioners, solenoid valves tubing, limit switches etc. in field on control valves. |
| 470 | Removal and remounting of accessories |
| 471 | CHIEF CONTROLLER OF EXPLOSIVE( CCE) CERTIFICATES FOR FIELD ELECTRICAL/ ELECTRONIC INSTRUMENTS & ACCESSORIES AND |
| 472 | EOQbtUaIinPiMngENcTerStificate of approval from Chief Controller Of Explosives (CCE) for field electrical/electronic instruments & accessories and equipments based on type test certificate made available from the instrument vendors including submission of application to statutory authorities, necessary fees, all test certificates, equipment drawings in required volumes, interaction with the authorities, follow- up for approval, obtaining necessary approval certificate before energization of field electrical/electronic instruments & accessories and equipments. |
| 473 | Deployment of Instrument Technicians along with required test equipments, tools & tackles for Calibration /Re- Calibration of field instruments, Functional Checks of Instruments, any other requirement as & when required as per the instructions of Engineer-in-charge. One manday is8 Hrs duty. |
| 474 | Deployment of Instrument Technicians |
| 475 | Deployment of Electrician with all the required tools and tackles as per the instructions of Engineer-in-charge.One Man Day is 8 Hrs Duty. |
| 476 | Deployment of Electrician |
| 477 | Deployment of Helpers (Semi skilled) with required tools & tackles as per the instruction of Engineer-in-Charge.One Man Day is 8 Hrs Duty. |
| 478 | Deployment of Helper |
| 479 | Supply of Manpower :Providing and Mobilising following manpower having qualification, as specified in the Special Condition of the Contract (SCC), as per instructions of Engineer in-charge for delivering exclusive service to B AND R. However, 2 weeks\" notice shall be given for mobilisation and 1 day notice shall be given for demobilisation. Note : Quoted rates of manpower deployment shall be inclusive of cost towards required PPEs, facilities necessary for functioning at site and complience of applicable Statutory obligation e.g P.F. & ESI etc. (1 Man-Month should be considered as 30 man-days). |
| 480 | LEAD ENGINEER : |
| 481 | INSTRUMENTATION |
| 482 | DISCIPLINE ENGINEER : |
| 483 | INSTRUMENTATION |
| 484 | SUPERVISOR |
| 485 | INSTRUMENTATION |
| 486 | \"NOTE:-THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST.\" |