}

Tender For Conservation And Restoration Of Munsi Premchandra Museum At Village Lamhi District-Varanasi, 1 Conservation & Restotation Of Munsi Premchandra Museum At Village Lamhi District-Varanasi. 2 Restoration Work 3 Dismantling Tile Work In Floors, varanasi-Uttar Pradesh

Government Departments has published Tender For Conservation And Restoration Of Munsi Premchandra Museum At Village Lamhi District-Varanasi, 1 Conservation & Restotation Of Munsi Premchandra Museum At Village Lamhi District-Varanasi. 2 Restoration Work 3 Dismantling Tile Work In Floors. Submission Date for this Tender is 06-07-2024. Footwears Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43977595
Tender For Conservation And Restoration Of Munsi Premchandra Museum At Village Lamhi District-Varanasi, 1 Conservation & Restotation Of Munsi Premchandra Museum At Village Lamhi District-Varanasi. 2 Restoration Work 3 Dismantling Tile Work In Floors
Open Tender
Indian
Uttar Pradesh
Varanasi
06-07-2024

Tender Details

Tender For Conservation And Restoration Of Munsi Premchandra Museum At Village Lamhi District-Varanasi, 1 Conservation & Restotation of Munsi Premchandra Museum at Village Lamhi District-Varanasi. 2 RESTORATION WORK 3 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 4 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 5 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 6 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 7 Careful removal of existing deteriorated/ damaged/ weathered lime plaster without damaging the surface below it. 8 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 9 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below 10 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 11 Removing white or color wash by scrapping and sand paperingwithout causing damage to the below stone/brick/plastered surface.and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Removal of all old plumbingInternal & External Pipe including wc, washbasin, taps etc. from toilet & stacking servicealble materials within 50 M lead. 13 Removal of stains, dirt, blackening and other contaminants from Stone by using the solution of Non Ionic soap diluted with water . The soap solution should be mild and the recommeded PH Value is 7. 14 Cleaning of enamel/modern/synthetic paint with help of suitable chemical 15 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 16 Proposal Work 17 Providing and laying lime concrete in footings and bases excluding cost of centring and shuttering With graded stone aggregate 40mm nominal size and mortar comprising of 1 lime putty :1 surkhi : 1 coarse sand 18 Providing and fixing Grouting Material with Lime mortar 1:2 (1 Lime : 2 Coarsesand) cost of required centering complete. 19 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 20 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 21 Traditional brick masonry in nanakshahi or lakhori bricks in lime mortar in proportion similar to the existing traditional lime mortar 1:1:1 (lime :1 surkhi: 1 finesand) 22 Traditional Brick work in plainarches in lime mortar 1:1:1 (1 lime : 1 coarse sand: 1surkhi) 23 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; i/c all complete 24 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars of grade Fe-500D or more 25 Preparation the surface and application:-a) Through cleaning of the grease residuces dishuttering agent, dust, loose materials etc from the surface. b) Loose particle should be cleaned from existing cavities in the concrete. c) Existing construction joint should be opened in a “V” shapetowards the inside, along their entire length, at a depth of 5mm and Providing & laying Doncrete –T single pack naturals Hydrophobic, breathable, flexible water proof render For roofslab conforming to DIN-1048 BS:8102,EN-1504-9, DIN-18550, @10 mm thick. 26 Providing and applying two coats of DONCRETE-LBP single component polyurethane lime Modified liquid waterproofing membrane System, confirming to ASTM C-836 and ASTM C 898. It should have Elongation at Break is 200% as per ASTM i/c all complete 27 30‐40mm lime plaster in two coats with 20mm base coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Coarse Sand)and top coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Fine Sand) 28 Lime concrete terracing on roofswith 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 Slaked lime : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with parpaet wall complete 29 Providing and fixing chicken wire mesh (6mm x 6mm) of 24 gauge 200 mm wide along the joints of R.C.C. work and brick work with hooks/nails etc. complete so as to receiving the plastering work over chicken mesh as per the direction of Engineer‐in‐charge. 30 Lime plaster 1:1:1 (1 slakedlime:1 surkhi: 1 fine sand) 20mmThick Double Coat 31 Raking out the joints of country/Nankshahi brick, scooping out dead and decayed mortar very slowly and carfully with scooping rods, then washing complete with hand spray pump. Preparing the surface for replastering including disposal of rubbish with 250m lead 32 40 mm thick rubbed stone flooring over 20 mm (average) thick base of lime mortar 1:3 (1 lime :3 coarse sand) with joints 3 mm thick, side buttered with lime mortar 1:2 (1 lime : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar Red sand stone 33 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 34 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 35 Supplying, drilling/cleaning hole and fixing appropriate length of ETA Approved HILTI HRD C 10 / RAWLPLUG anchorsuitable for fastenings both on concrete & masonary/aerated blocks. Length of anchor should be decided on the basis of embedment depth in base material, total frame thickness & gap between frame and base material. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade countersunk head double threaded screw made of carbon steel galvanized to minimum 5 microns. CF 125 insulation foams should be used to fill the gaps between frame & base material. Fixing methodology to be followed as per manufacturers guidelines 36 Frame anchor HRD-C 10x140 37 Frame anchor HRD-C 10x100 38 Lime punning with lime putty mixed with Gur,Bilgri,Urd and other ingredients followed by grinding to fine paste for smooth finish 39 French spirit polishing : Two or more coats on new works including a coat of wood filler 40 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 41 Extra for providing and mixing water proofing material in Lime plaster work in proportion recommended by the manufacturers. 42 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 43 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 meter height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 meter centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system i/c all complete 44 Manually removal of vegetation (major trees, climbing plants, creepers) from walls, columns, arches, floor etc in a skilled and careful manner, using appropriate tools and means and without causing any damage to the adjoining parts, i/c all complete 45 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood 46 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood35 mm thick shutters 47 Providing &fixing of 40 mm thick second class teak wood planks frame and 5.5mm thick tinted glass fixed in frame help of beading all necessary T&P all complete in direction of engineer in charge. 48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 49 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 50 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 250x16x5 mm 51 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 52 (a) 250 mm x 10mm 53 (a) 200 mm x 10mm 54 Providing and fixing bright finished brass handles with screws etc. complete:125 mm 55 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 56 Providing and fixing of cast iron Railing design as per existing character including fixing in wooden member etc all complete in direction of engineer in charge. 57 Repairing ornamental plaster works to match with the existing design using lime plaster (1lime putty:1surkhi) 58 Nano technology based protection technology coating lime wash paint coating lime wash paint Sand Stone Surface/exposed brick work surface / wooden surface with nano technology based paint protection coating to protect porous material against watering staining chlorophyllon aquas based emulsion (Make Narolac/ Ashian/imper guard xp or equivalent) 59 Lime wash / Colour wash with matching original character manufacture to give an even shade : Two or more coats on new work 60 Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System with 15 mm thick Optra Microlook 90 Edge Tiles with Knauf Suprafine 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White/Black i/c all complete 61 Providing & Fixing of Forbo Flotexcolor/linear series flocked floor covering rolls having a density of 70 million fibres of nylon 6.6 per Sqm , Fire Test EN-13501, Appearence Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, sanitized anti-microbial treatment with resilient waterproof backing ,anti allergiccetrtified by British allergy foundation, anti static, stain resistant, thickness 4.3 mm i/c all complete 62 Providing & fixing 10.5 mm thickengineerwood flooring american exotic bruce 7 layerconstruction,top layer of wood veener 2mm ,plank size width 120 mm ,length 400-1200 mm,Lock & fold locking ,premium finish,micro bevel edges/ends with an underlayment made of natural colour foam,with accessories like end profile,transition profile,reducer ,etc.complete.The profiles are 100% matching. profile at door openings Make-Armstrong/FloorMaster 63 Supplying Testing & Installation of Lift 100 mm Pit or Step ( ONLY 4 INCHES) 2500 mm Headroom, Single Phase Operation (Just 1.4 Kva Power Consumption),Zero Power While Descend, No Side Wall / Column / Beam or Supporting Structure Required, No Machine Room Required / Head Room Required, Safety Curtain in Door 194 safety parameters undertaken Soft Start and Soft Stop Feature Emergency Light, Telephone, 64 Providing & fixingSand Stone single piece slab ornamental benches of approved design pattern (shape) and specifications includingc c 1 :2 :4 grouting, all materials, labor and T & P etc. required for proper completion of work as directed by engineer - in -charge. 65 Providing and fixing sand stone Dustbins in 75 mm thick red sandstone with jali and carvingproperly shaped as per design of approved size, quality and standard specifications withremovable metal bin inside properly fixed to stone body approved design pattern (shape) and specifications includingc c 1 :2 :4 grouting, all materials, labor and T & P etc. required for proper completion of work as directed by engineer - in -charge. 66 INTERNAL ELECTRIFICATION 67 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 68 Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 70 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 71 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 72 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 73 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 74 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 75 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 76 20 mm. 77 25 mm. 78 32 mm. 79 S/F light plug point modular type accessories :- 80 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 81 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 82 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 83 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 84 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 85 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required 86 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 87 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 88 4 way (4 + 12), Double door, horizontal type 89 6 way (4 + 18), Double door, horizontal type 90 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required single pole 91 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 92 40 amps. 93 63 amps. 94 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 95 Supplying and fixing 20 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 96 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 97 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 98 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 99 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 100 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 101 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 1200 mm sweep 102 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 103 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 104 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 105 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 106 Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required.1 nos. RJ 45 Data Outlet 107 Supply, Installation, Testing & Commissioning of Led fixture 600mmX600mm 33 W+/- 1W Recess Mounted Decorative Fixture having Light engine and diffuser only on the edeges and hollow in between with Drop Down HET PMMA diffuser fixture with extruded aluminium housing with P.F.>0.95 with THD<10% ,CRI 80,CCT 5700 K.The LED with Useful life of 50000 Hrs at L70.LM29-451-XXX-57-XX. or Equivalent in Philips : Day Space or Trilux : Oplana LED. 108 Supply, Installation, Testing & Commissioning of IP20 led fixture 12 W +/- 1 W LED Recess Mounted Downlighter Round Shapeminimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70 .Fixture have Surge Protection 2kV . 109 Supply, Installation, Testing & Commissioning of Led fixture 600mmX600mm 36 W+/- 1W Recess Mounted with PMMA diffuser with having minimum system lumen efficacy of 100lm/W having CRCA housing with P.F.>0.95,THD<10%,CCT 5700 K ,CRI 80.Wipro Cat.No:CRCO10R038HP57GL1 or Equivalent in Philips : RC380B LED36S- 6500 G5 L60W60 PSU OD or Trilux 110 Supply, Installation, Testing & Commissioning of COB LED Track Light 20 Watt having system efficacy of 100 lumen per watt with die cast aluminium housing having CCT of 4000K, .Wipro Cat. No: LD57-251-024-40-XX or Philips or Trilux 111 Supply, Installation, Testing & Commissioning of Single one Meter Track+ Connector . Including all Accessories 112 Supply, Installation, Testing & Commissioning of Cone Shape Led fixture 20 W+/- 1W with Suspended Mounted diffuser with Black Housing and diffused light.Wipro Cat. No:LM45-221-XXX-40-BLor Philips or Trilux 113 Supply, Installation, Testing & Commissioning of Led fixture 600mmX600mm 33 W+/- 1W Recess Mounted Decorative fixture having Light engine and diffuser only on the edges and hollow in between with Drop Down HET PMMA diffuser with Colour Tunning & DALI Dimmable with only extruded aluminium housing. P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have variable CCT from 2700-6500 K with CRI of minimum 80. Make : Wipro / Philips / Trilux. 114 Supply, Installation, Testing & Commissioning of IP20 12 Watt Surface Mounted LED Down Lighter having system efficacy of 100 lumen per watt with pressure die cast heat sink having CCT 5700 K only .Wipro Cat. No: LD06-151XXX-57SMG1 orPhilips or Trilux 115 Supply, Installation, Testing & Commissioning of IP66 60 Watt LED Flood Light having system efficacy of 100 lumen per watt with pressure die cast aluminum housing having CCT 5700 K only .WiproCat. No: LF19-711-060-57-XX or Philips or Trilux 116 Supply, Installation, Testing & Commissioning of IP 67 Garden Light having wattage 8 Watt, having pressure die cast housing with minimum beam angle of 36 degree and CCT 2700 K. Fixture is suitablefor only outdoor applicationWipro Cat. No: LD57-251-024-40-XX or Philips or Trilux 117 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete 300mm sweep 118 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete300mm sweep 900rpm 119 Supply,installation, testing and commissioningof Main DistributionBoard suitable for upto 125 amp FP MCCB incomer and single / three phase outgoing MCBs, IP 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 V / 200 amp copper Bus Bar, earth and neutral bar, i/c all complete 8 way TPN 120 Providing and fixing of following rating Four poleMCCBs at the incomer of Main/sub distribution boards withconnections etc. complete as required 100 Amp FP MCCB 116 (KA). 121 Supplying, fixing, connecting, testing and commissioning of followingrating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker (MCB)of single / double / three / four poles in the existing MCB DB or in existing MS enclosure complete in all respects. 122 25 Amp. TP MCB 123 40 Amp.TP MCB 124 63 Amp. TP MCB 125 Design,manufacture, supply,testing and commissioningofMain Panelfabricated out of 14 SWG CRCA sheet steel, IP 42, wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect. 126 42 nos 32 AMP FP MCB (10 KA) 127 6 nos 32 AMP FP MCB (10 KA) 128 Wiring for light point/fanpoint/exhaust fan point/call bell pointwith 1.5sqmmFR PVC insulated copperconductor single core cablein surface wooden Batten, with Traditional switch, Traditional plate, suitable wooden box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required.(Goup C) (Make:- SSK Heritage Series or Equivalent) 129 Supply and fixing of suitable size Wooden Box with Traditional plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps. Traditional socket outlet and 5/6 amps. switch, connection, painting etc. as required.(Make:- SSK Heritage Series or Equivalent) 130 Supply and fixing of suitable size GI box with Traditional plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps.Traditionalsocket outlet and 15/16 amps. Traditionalswitch, connection, painting etc. as required.(Make:- SSK Heritage Series or Equivalent) 131 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing & fixing 3pin 20 amps modular socket outlet and 20 amps mini SP MCB 3 KA (for ac & gyser), connection, painting etc. as required. 132 Supplying & drawing 2 pair, 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing wooden Batten as required. 133 Supply and fixing offollowingsizes of wooden Batten along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 134 20 to 40mm 135 Supplying and fixing following Traditional switch/ socket with Traditional plate & switch box including connections etc. as required.(Make:- SSK Heritage Series or Equivalent) 136 Telephone socket outlet 137 Computer Jack for RJ-45 Socket 138 Supply and fixing of Traditional Type stepped type electronic fan regulator on the existing Traditional Typeswitch box including connections but excluding Traditional Typeplate etc. as required.(Make:- SSK Heritage Series or Equivalent) 139 Supply and fixing Traditional Type blanking plate on the existing Traditionalplate & switch box excluding Traditional plate as required.(Make:- SSK Heritage Series or Equivalent) 140 Supply, installation, testing & commissioning of following pairs of IDF having LSA-Plus disconnection module, back mounting frame & wire manager on good quality power coated MS box with lock & keys. 10 pair 141 FIRE FIGHTING 142 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 143 25 mm dia. 144 32 mm dia. 145 40 mm dia. 146 50 mm dia. 147 65 mm dia. 148 80 mm dia. 149 100 mm dia. 150 Providing, laying, testing & commissioning of B class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required25mm dia 151 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 152 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 153 40 mm dia 154 100 mm dia 155 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100MM DIA 156 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless flange. 100mm dia 157 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 158 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 159 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 160 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 161 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories pendent sprinkler : 162 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm dia 163 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000mm 164 Deduct in item no. 501 (I) 501 (t) and 506 (a) to (f) when cables is passed through G.I./M.S. or Hume pipe in road crossing or along the wall. The cost of the G.I. pipe, hume pipe is to be extra when and where required. 165 16 Sqm. mm 4 core (Rate after deduction) 166 Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge. 167 ABC dry powder Type 6 kg. capacity 168 CO2 gas type. 4.5 kg. capacity 169 Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. 170 Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheethavingglass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words FIRE HOSE to be painted on the box. 171 Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm)outdoor typemade of not less than 16 SWG MS sheethaving glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipeas required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted onself standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 172 Supply / installation / Testing and Commissioningof Air Release valve (ARV) with forged brass body full way ball valve type isolating valve, flanges / union, suitable for sprinkler / wet riser / down comer system with all necessary connections complete in all respects 173 Supply, fixing, testing & commissioning of 25 mm dia inspecting and testing assembly with gun metal valve, sight glass, by pass valve and connection to the drain line as required to complete the system. 174 Supply, Fixing, Testing & Commissioning of electrical motor driven fire pump, suitable for automatic operation consisting of following : (TERRACE PUMP). 175 (a) Horizontally mounted, end suction type, Centrifugal fire pumpwith operating speed of 2900 rpm, as per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers, 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm i/c all complete 176 Discharge :1350 liter per minute 177 Head :35 meter 178 Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CTs, protective fuses, single phasing protection, dry suction cut off etc as required as per standard details. 179 Supply, fixing of CP cap for sprinkler heads to be mounted at false ceiling / vertical. 180 Providing and fixing in positionG.I.pipe sleeves (medium class) of upto 300 mm longduly tack weldedwith the reinforcement of RCC beams /wall and other structural members during the time of casting the same includingpainting with two coats of anti corrosive paint over primer. (for the crossing of sprinkler pipes) 181 80NB 182 100NB 183 150 NB 184 FIRE ALARM 185 Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. 186 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 187 Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 188 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required 189 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 190 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & peaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required 191 Supplying, installation, testing & commissioning of maincontrol and indicating panel made out of 16 SWG MS sheetto accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. I/C all complete 192 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 193 Supplying, receiving, storing, handling, fixing, wiring for fire alarm system wiring using ISI marked (IS 694) 1100 Volts grade, PVC insulated, flexible, flame retardant low smoke (FRLS) copper conductor wire, drawn in existing solid / flexible conduits / casing caping including connections to the detectors, manual call points, hooters, response indicators, accessories, fire alarm control panel etc. includingtermination with bottle type copper lugs, connectors etc as required to complete the system.2*1.5 sqmm 194 Supply and laying of ISI marked Copper conductor PVCinsulated FRLScontrol cable as per IS 1554or XPLE insulated as perIS 7098PVC sheathed1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. i/c all complete. 6*1.5sqmm armoured 195 Providing and fixing of self illuminated / auto glow EXIT signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 300 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. 196 PLUMBING 197 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 198 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. 199 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 200 32 mm dia 201 40 mm dia 202 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 203 Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: 204 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. granite stone of approved shade 205 Providing and fixing unplasticised PVC connection pipe with brass unions 15mm nominal bore 206 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15mm nominal bore 207 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms. 15mm nominal bore 208 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15mm nominal bore 209 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia 210 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 211 110mm 212 90mm 213 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110mm dia 214 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110mm 215 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 216 Bend 87.5 degree 110mm bend 217 Shoe (Plain) 110 mm shoe 218 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 219 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm 220 Providing and fixing 15cm wide 45cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 221 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 222 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 223 20mm dia nominal outer dia pipes 224 25mm dia nominal outer dia pipes 225 32mm dia nominal outer dia pipes 226 Providing and fixingGI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). 227 20mm dianominal bore 228 25mm dia nominal bore 229 32mm dia nominal bore 230 40mm dia nominal bore 231 50mm dia nominal bore 232 Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work. 233 20mm dia nominal bore 234 25mm dia nominal bore 235 32mm dia nominal bore 236 40mm dia nominal bore 237 50mm dia nominal bore 238 Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). 239 25mm dia nominal bore 240 32mm dia nominal bore 241 40mm dia nominal bore 242 50mm dia nominal bore 243 Providing and fixing gun metal gate valve with wheel of approved quality. 244 25mm dia nominal bore 245 32mm dia nominal bore 246 40mm dia nominal bore 247 50mm dia nominal bore 248 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. 249 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. 250 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm dia 251 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia sw pipe 252 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150mm rcc pipes 253 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150mm rcc pipes 254 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 255 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm 256 (i) For Sewer Line 257 Size 90X80 cm with FPS bricks (class I ). 258 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design with 20*20mm square bar 259 Providing and fixing on wall face unplasticised Rigid PVC soil and waste water pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 260 a) 110mm dia P.V.C. pipe 261 b) 90mm dia P.V.C. pipe 262 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 263 P-Trap type Floor Trap 110 x 110mm 264 a) 110mm 265 b) 90mm 266 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 267 110mm bend 268 90 mm bend 269 110mm 270 90mm 271 90x90x90 mm single tee with door 272 110x110x110 mm 273 Providing & fixing Towel Rail 300mm Long For Wash Basin Area Appoved Make as per direction of engineer / Architect in charge. 274 Providing & fixing Soap Dispenser with Metallic bottleAppoved Make as per direction of engineer / Architect in charge. 275 Providing & fixing Bottle Trap (With Internal Partition) 32mm Size With 250mm & 190mm Long Wall Connection Pipes & Wall FlangeAppoved Make as per direction of engineer / Architect in charge. 276 Providing and fixing Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook (for E.W.C.)Appoved Make as per direction of engineer / Architect in charge. 277 Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore Appoved Make as per direction of engineer / Architect in charge. 278 Providing and fixing clean out plug110mm dia 279 LANDSCAPING 280 Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 281 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 282 Providing and stacking of Terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 283 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 284 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 285 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 286 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 287 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 288 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 289 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size ofPoly bags & as per direction of the officer-in-charge. 290 Providing and stacking of Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 291 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 292 Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 293 Trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 294 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 295 Supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 296 Mixing earth and manure in specified proportion or as directed. 297 Rough dressing the trenched ground including breaking the clods. 298 Fine dressing the ground 299 Spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 300 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 301 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 302 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 303 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 304 PATHWAY PAVING 305 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 306 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 307 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixedwith pigment to match the shade of stone and pointing with same mortar. Red sand stone 308 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent 309 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 310 Brickwork with class 150 bricks in Foundation upto plinth levelin Cement & coarse sand mortar 1 : 4 including supply of all materials, labour, T & P and curing etc. required for proper completion of the work 311 EXTRNAL ELECTRIFICATION LIGHTING 312 Supply & Fixingof’ 5mtr long Antique designed pole with cast aluminium/iron base with galvanizedsteel pipe and decorative top painted with primer then painted with dull finished polyurethane paint fitted with MCB and connectorwith decorative bracket single arm for mounting of 1nos drop down lantern with body made out ofspun aluminium and fitted with poly carbonate diffuser in 110W with built in surge protector and lumn output>110lmn/watt. Design as per Architect in charge. 313 Supplying Testing & Installation of Led Flood Light Luminaire 50WPhilips Make Model - BVP 140 Led 50 CW PSU WH/ Wipro/ Luster etc all complete of direction of engineer in charge. 314 Supplying Testing & Installation ofLed Flood Light Luminaire 100WV Philips Make Model- BVP 142 Led 100 CW PSU WH / Wipro/ Lusteretc all complete of direction of engineer in charge. 315 Supplying Testing & Installation of Garden Spike Light 12W WWMake Philips/ Wipro/ Lusteretc all complete of direction of engineer in charge. 316 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 317 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 318 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassn nut bolt & spring washer spaced at 50mm) 319 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 320 6.00 Sqmm 4 Core 321 25.00 Sqmm 3.5 Core 322 70.00 Sqmm 3.5 Core 323 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 324 63 mm dia (OD-63 mm & ID-51 mm nominal) 325 90 mm dia (OD-90 mm & ID-76 mm nominal) 326 Suplying installation testing and commissioning of VRV/VRF System i/c indoor outdoor units piping, cabling/bustrunking/ rising main ( within the blinding), wiring, electrical panel and also treated fresh air system. ( 8 USER) 327 INTERIOR WORK 328 HD Projector for Seminar Hall 3000 Lumens (Make Sony/ Samsung) 329 Kiosk for Ticket counter and souvinenier shop 330 Audio System For Seminar Hall (Make JBL/ Bose) 331 Providing & fixing of Gypboards Partition for Green room including fixing with nut bolts washer etc all complete in direction of engineer incharge. 332 P/F Rollar Curtain Blinds 333 Providing & fixing of Glass Railing with stainless steel 900 mm high etc all complete in direction of engineer in charge. (Make Ozone) 334 P/F SIZE=3.5X1.5X1.50MT. (5.00Nos.) Diorama display boxTeak Wooden frameand teak beading finished edges. Including Providing & fixing of6mm Glass on 1 side for display including patch fittings etc all complete in direction of Architect in charge.. Refer Drg. 335 Showcases Providing and fixing Cabinets with 1mm laminate (Century/Formica /Greenmake as/ shade approved by the Architect) over 18 mm Ply water proof (Century/ Green/Duro make), Plywood conforming to international formaldehyde emission standards)and post formed edges finished and duly Melamine/ PU polished on outer surface and inner surface finished with 0.8 mm mica (Century/Formica /Greenmake as/ shade approved by the Architect. The unit shall have cam locks, handles, guides, sliding units, hinges, magnetic catcher’s etc Ozone/ Dorma make of as/design approved by architect Including Providing and fixingof 12 mm thick toughened glass panel of specified size using hardware, patch fittings- namely steel studs as per drawing.etc all complete in direction of architect in charge. Ref. Drg. 336 Design & supply & fixing of Display material has to be printed on LG/Garware/3M Film and pasted on the glass.etc all complete in direction of architect in charge. Ref. Drg. 337 Providng & fixing of Photograpic display panels (Size 600mmx 750mm) 338 Signage 339 Object Interpretation Signage 340 Directional Signege 341 Main Museum signage 342 Utility Signages 343 Display Panel Signage 344 Brochers Design & Printing 345 Curation of museum material (Copy writing of all text to be displayed ) 346 Supplying installation testing and commissioning of IP based CCTV system for building security comprising of PTZ, Fixed camera, cabling, recording, display system and hardware and software support. (Suppliment DSR 2014 Page 6 Item no. 11) 347 Providing & fixing of Public addressal system 348 Cost of Virtual Augementation & Animetronix 3D Robotic Gallary 349 Providing & fixing of room interiors in old personal house depectiong in style of the period of Munshi PremChandra . 350 Bed Room 351 Living Room 352 Kitchen 353 Study Room 354 Other Rooms 355 Cost of Restoration of Object 356 Cost of Creation of Object 357 Cost of Establishment of Lab 358 Cost of External Diorama 359 Research Schollar 360 Copy Writer 361 Conservator 362 Providng & fixing of Touch screen Information kiosk including data cabling wire etc all complete in direction of engineer in charge for reality experience 363 Scalled model of old house (place of birth of munsi Prem Chandra at 1:50 Scale with humen accessbility).

Key Value

Document Fees
INR 17700 /-
EMD
INR 1778000.0 /-
Tender Value
INR 8.89 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail