}

Tender For Tourism Development Work Of Mahakaleshwar Temple At Bhadan In District-Firozabad. (U.P), 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm, Firozabad-Uttar Pradesh

Government Departments has published Tender For Tourism Development Work Of Mahakaleshwar Temple At Bhadan In District-Firozabad. (U.P), 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm. Submission Date for this Tender is 13-07-2024. General Hardware Tenders in Firozabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43955944
Corrigendum : Tender For Tourism Development Work Of Mahakaleshwar Temple At Bhadan In District-Firozabad. (U.P), 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm
Open Tender
Indian
Uttar Pradesh
Firozabad
13-07-2024

Tender Details

Tender For Tourism Development Work Of Mahakaleshwar Temple At Bhadan In District-Firozabad. (U.P), 1 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil 2 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 3 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 5 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 6 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). 7 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 8 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). 9 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform 10 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 11 Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) 12 Providing & applying a coat of residual petroleum bitumen of grade ofVG-10 of approved quality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apieceof cloth lightly soaked in kerosene oil. 13 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : 14 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level 15 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.(TMT Bars) Fe-500 16 15 mm cement plaster on rough side of single or half brick wall ofmix: 1:4 (1 cement: 4 coarse sand) 17 15 mm cement plaster on rough side of single or half brick wall ofmix: 1:6 (1 cement: 6 coarse sand) 18 12 mm cement plaster on rough side of single or half brick wall ofmix: 1:6 (1 cement: 6 coarse sand) 19 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 20 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in all colours, shades,except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry@ 3.3 kg/ sqm including pointing the joints with white cement andmatching pigments etc., complete. 21 Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 22 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) 23 Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. 24 Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats25 mm to 115 mm 25 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase. 26 Providing and fixing angle iron frames for doors, windows and ventilatorsof mild steel angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessarybutt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge 27 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 28 Providing and fixing factory made ISI marked steel glazed doors, windowsand ventilators, side /top /centre hung, with beading and all memberssuch as F7D,F4B, K11 B and K12 B etc. complete of standard rolledsteel sections, joints mitred and flash butt welded and sash bars tenonedand riveted, including providing and fixing of hinges, pivots, includingpriming coat of approved steel primer, but excluding the cost of otherfittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) 29 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 30 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 31 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality 1.5 mm thick 32 Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item):With float glass panes of 4.0 mm thickness (weight notless than 10kg/sqm) 33 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 34 PLUMBINGProviding and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid 35 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. White Vitreous China Flat back wash Basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 36 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia 37 Providing and fixing unplasticised PVC connection pipe with brass unions45 cm length15 mm nominal bore 38 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore 39 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.15 mm nominal bore 40 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15 mm nominal bore 41 Providing & fixing soil, waste and vent pipes. PVC pipe conforming toIS make working pressure 4 Kg/SqCm incuding testing labour T&P and all complete fittings 100mm dia 42 Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors.100mm inlet & 75mm outlet. 43 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.110mm 44 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 45 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15mm dianominal bore 46 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20mm dianominal bore 47 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25mm dia nominal bore (medium duty) 48 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].Capcity in Liters 49 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 50 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm diameter 51 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design100mm dia SW pipe 52 ELECTRICALWiring point for light with 1.5 sq.mm.FRLSHPVCinsulated multistrand single core copper conductor cablein PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thickphenolic laminated backalite sheet etc complete in all respect as directed including matching colour wash.SI No. 138 C 53 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting,complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash.SI No. 140 C 54 Supply and fixing ofLED Tube Light batten fittingsuitable for up to 1 X 22 watt LED tube light on surface complete in all respect. SI No. 1413 A Cat AAA 55 Supply and wiring of submain with two number2.5sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduitetc, complete in all respects including matching colour wash. SI No. 1307 C 56 Supply and wiring of submain withtwo number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduitpartly concealedinwall andpartlylaid in slab alongwith reinforcement before concreting, with one no. 2.5 sq. mm.FRLSH PVCinsulatedmultistrand copper conductor cable as earth continuity wire drawn in conduit. including matching colour washetc. complete in all respect. SI No. 221 C 57 Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX 58 SEPTIC TANKEarth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed.From 0.00 mt to 1.50 mt 59 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 60 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 61 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 62 Reinforcement of Reinforced concrete or reinforced brick work (When not included in and an over all rates) brought to required shape as necessary including bending for proper completion of the work and including the supply of steel and its waistage Bend, hooks, Binding wire and authorized over lapping shall be measured upto floor two level.(TMT Bars) Fe-500 63 15mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering upto floor to level including internal rounded angles chamfers, and rounded angles not exceeding 80mm. In girth and finished even and smooth. (II) 1 cement : 4 Coarse sand 64 Constructing circular soak pit 2.5m internal diameter and 3m effective depth including excavation, disposal of surplus earth, refilling it with coarse aggregate and RCC slab on to 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate) with 450mm dia manhole cover and frame complete as required as per the standard design. 65 INTERLOVKINGProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 66 Laying of I shaped precast Interlocking tiles of thickness 80 mm (Rubber molded)(Compressive strength not less then 30Mpa and weight 4.50kg) Including 25mm thick local sand base levelling and dressing of surface to required level and slope, filling joints with local sand all complete work 67 Supply of Solar AIO Single piece High pressure Die cast (LM6 Alloy) 17W Aluminium housing appearance of Solar AIO shall be traditional Street Light, IP65 & IK08, suitable for OD 50/60mm bracket, having Min 3000 lumens, suitable for 24hrs (2 Nights) Autonomy and its backup calculation sheet shall be approved by Consultant Dimming Profile: From Dusk - First 05hours sensor enabled with 30% brightness levelNext 05Hours sensor disabled and fixed at 30% Brightness level Next 2hours/dawn- Sensor enabled with 30% brightness levelLithium pherrophosphate Battery capacity min 20Ah@12.8V or 256 watt hour & shall be of fresh manufactured battery (Not re-used cells) Battery Temp range -20-+60°C and panel capacity min 35Wp, CRI >=70, Efficacy Min >175lm/W is MUST, system wattage should not be more than 17W ± 5%, if wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. Life class of LED System 50000hrs@L70, LED -CREE/NICHIA/LUMILEDS/OSRAM. CE Certified, charger efficiency >90% and standards IEC62109-1, IEC61547, CISPR15, IEC62093, IEC61347-2-13, EN50530, IEC62384 Make The PV module should be made up of crystalline silicon solar cells Mono-Crystalline* and must have a certificate of testing conforming to IEC 61215 Edition II/BIS 14286 & IEC 61730-1,2 IEC60598, Operating temp 0 Degree C to 50 Degree C, certifying above given prameters all reports shall be from In-house NABL or IECQ or any international accredited Laboratory, Complete luminaire/battery/panel/charge controller must be BIS accredited (if applicable) and as per UPPWD Approved Product List Philips Make 68 Finishing wall with murals painting with scraping of old painting,one coat of putty and 2 coat arcylis painting with designer art work complete ON BOUNDARY WALL 69 Providing & Fixing ofRO SYSTEM (150 LPH) 70 Providing & Fixing ofWATER COOLER (150 LTR) 71 Providing & Fixing ofStone Bench 72 G.S.T Extra as per applicable

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-07-2024 Date Extend Date 13-07-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 36000.0 /-
Tender Value
INR 17.79 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail