}

Tender For Rewinding Of Motors, kichha-Uttarakhand

Kichha Sugar Company Limited has published Tender For Rewinding Of Motors. Submission Date for this Tender is 06-07-2024. Rough Finishing Tools Tenders in kichha Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

43923199
Tender For Rewinding Of Motors
Open Tender
Indian
Uttarakhand
Kichha
06-07-2024

Tender Details

Tender For REWINDING OF MOTORS-REWINDING OF MOTORS 2 UP TO 1.5 KW2 HPSTATOR 3 2.2 KW 3 HPSTATOR S/CS/R 4 3.7 KW 5 HPSTATOR 5 3.7 KW 5 HPROTOR 6 5.5KW 7 .5 HPSTATOR 7 5.5KW 7 .5 HPROTOR 8 7.5 KW10 HPSTATOR 9 7.5 KW 10 HPROTOR 10 9.3 KW 12.5 HPSTATOR 11 9.3 KW 12.5 HPROTOR 12 11 KW 15 HPSTATOR 13 11 KW15 HPROTOR 14 15 KW 20 HPSTATOR 15 15 KW 20HPROTOR 16 18.5KW 25 HPSTATOR 17 18.5 KW25 HPROTOR 18 22 KW 30 HPSTATOR 19 22 KW 30 HPROTOR 20 26.5 KW35 HPSTATOR 21 26.5 KW35 HPROTOR 22 30 KW 40 HPSTATOR 23 30 KW 40 HPROTOR 24 37 KW 50 HPSTATOR 25 37 KW 50 HPROTOR 26 45 KW 60 HPSTATOR 27 45 KW 60 HPROTOR 28 55 KW 75 HPSTATOR 29 55 KW 75 HPROTOR 30 60 KW80 HPSTATOR 31 60 KW 80 HPROTOR 32 67 KW 90HPSTATOR 33 67 KW 90HPROTOR 34 75 KW 100HPSTATOR 35 75 KW 100HPROTOR 36 82.5 KW 110 HPSTATOR 37 82.5 KW 110 HPROTOR 38 90 KW120 HPSTATOR 39 90 KW 120 HPROTOR 40 112 KW 150 HPSTATOR 41 112 KW150 HPROTOR 42 125 KW 167 HPSTATOR 43 125 KW167 HPROTOR 44 132 KW 175 HPSTATOR 45 132 KW 175 HPROTOR 46 135 KW180 HPSTATOR 47 135 KW180 HPROTOR 48 150 KW 200 HPSTATOR 49 150 KW 200 HPROTOR 50 00 KW125 HPSTATOR SLIPRING MOTOR 960RPM 51 100 KW125 HPROTOR SLIPRING MOTOR 960RPM 52 160 KW215 HPSTATORS/CS/R 53 160 KW215 HPROTOR 54 165 KW220 HPSTATOR 55 165 KW220 HPROTOR 56 187 KW250 HPSTATOR 57 187 KW250 HPROTOR 58 220KW 300 HPSTATOR 59 220 KW300 HPROTOR 60 300 KW 400 HPSTATOR 61 300 KW 400 HPROTOR 62 3.7 KW5 HPSTATOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 63 3.7 KW5 HPROTOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 64 7.5KW 10 HPSTATOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 65 7.5 KW10 HPROTOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 66 9.3 KW 15 HPSTATOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 67 9.3 KW15 HPROTOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 68 18.5 KW25 HPSTATOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 69 18.5 KW25 HPROTOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 70 22 KW 30 HPSTATOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 71 22 KW 30 HPROTOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 72 26.5 KW35 HP STATOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 73 26.5 KW35 HPROTOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 74 28KW40 HPSTATOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 75 28 KW 40HPROTOR CANE MOTOR DUTY S4 (INSULATION CLASS F) 76 30 KW 40 HPSTATOR SUBMERSIBLE PUMP MOTOR 77 30 KW 40 HPROTOR SUBMERSIBLE PUMP MOTOR 78 28 KW 45 HPSTATOR SUBMERSIBLE PUMP MOTOR 79 28 KW 45 HPROTOR SUBMERSIBLE PUMP MOTOR 80 37 KW 50 HPSTATOR SUBMERSIBLE PUMP MOTOR 81 37 KW 50 HPROTOR SUBMERSIBLE PUMP MOTOR 82 18.5KW 25 HP RPM-960 REWINDING/STRIP WINDING OF ROTOR OF FOLLOWING OVER HEATED BURNT MOTORS CAT S-5 83 18.5KW 30 HP RPM-960 REWINDING/STRIP WINDING OF ROTOR OF FOLLOWING OVER HEATED BURNT MOTORS CAT S-5 84 18.5KW 40 HP RPM-960 REWINDING/STRIP WINDING OF ROTOR OF FOLLOWING OVER HEATED BURNT MOTORS CAT S-5 85 18.5KW 60 HP RPM-960 REWINDING/STRIP WINDING OF ROTOR OF FOLLOWING OVER HEATED BURNT MOTORS CAT S-5 86 7.5 HP Stator cane unloader duty motor S4 87 Siemens make three Speed Centrifugal Motor with six nos. New 120 º C PTC WITHOUT Thermistor 88 Connection plate up to 60 HP Motor 89 Connection plate 60 TOHP Motor 90 Connection plate ABOVE 120 HP 3 SPEED Motor 91 Cooler Fan 3 Speed 92 Cooler pump Motor 93 Single phase Motor up to 2 HP 94 Ceiling Fan900/1050 mm 95 Ceiling FanBUT 1200 mm 96 Ceiling FanBUT 1400mm 97 Exhaust Fan 3 phase 900 mm. 98 Exhaust Fan singlephase 300 mm. 99 Exhaust Fan single phase 450 mm. 100 Exhaust Fan singlephase600 mm. 101 Exhaust Fan single phase 900 m m. 102 Air Circulator 450mm. 103 Welding Machine 30 KVA Single Holder per coil 104 Welding Machine 30 KVA double Holder per coil 105 Replacement of worn-out lead up to 7.5 KW(Rates to be quoted per lead basis) 106 Replacement of worn-out lead above 7.5 KW-21KW(Rates to be quoted per lead basis) 107 Replacement of worn-out lead above 22 KW-44KW(Rates to be quoted per lead basis) 108 Replacement of worn-out lead above 45 KW-89KW(Rates to be quoted per lead basis) 109 Replacement of worn-out leadup to90 KW-187 KW(Rates to be quoted per lead basis) 110 Repair of Rotor joint up to 30 HP and up to 5 joints 111 Repair of Rotor joint up to 30 HP further per joint 112 Repair of Rotor joint up to 5 joint 31 HP-119 HP 113 -------------do --further per joint. 114 -------------do up to 5 joint 120 HP-220HP. 115 -------------do further per joint 116 -------------do up to 5 joint 300 H.P 117 -------------do further per joint 118 -------------do up to 5 joint 400 H.P 119 -------------do further per joint 120 Holding Coil of contractor3 TA-28 121 3 TA- 24 122 Dynodrive coil50 HP 123 Dynodrive coil60 HP 124 Dynodrive coil100 HP 125 a) Rewinding of Input 220/240 Volt & output 24Volt Transformer 2 KVA 126 b Rewinding of Input 220/240 Volt & output 24Volt Transformer 5KVA 127 Break Holding Coil of Mill Crane 128 Rewinding of Welding D.C. Generator 129 (a) Stator Primary 130 (b)Stator Secondary 131 (c)Rotor 132 (d) Resistance of Regulator 133 Repairing of Collar of Motor Body and Side Cover for motors 134 (A) 1H.P TO 20 HP 135 (B) 25 H.P TO75 H.P ( Per Motor) 136 (C) Above 75 H.P TO 150 H.P 137 (D) Above 150 H.P TO 400 H.P 138 E) Replacement/Repair of SIEMENS Make 3 Speed C/f Machine Motor Fan. 139 F) Replacement of SIEMENS Make 120 HP Motor Shaft of 140 KT-1350 Centrifugal machine 141 G) Replacement of SIEMENS Make 75 HP Motor Shaft of 142 NK-1100 Centrifugal machine 143 Rewinding ofJyoti Make alternator166 KVa, 133 KW, 415V 144 a) Armature (stator) Winding 145 b) Pole (Rotor) Winding 146 c) Exciting Choke Winding 147 a) Repair of hydraulic break thruster 25 Kg 148 b) Repair of hydraulic break thruster 30 Kg 149 STRIP WINDING OF ROTOR OF THE FOLLOWING SLIPRING MOTORS:- 150 120 H.P. 151 150 H.P. 152 175 H.P. 153 200 H.P. 154 220 H.P. 155 250 H.P. 156 300 H.P. 157 400 H.P. 158 Alternator 1248 KW 159 Alternator 3000 KW 160 Connection plate for above 161 ASSEMBLY/ FITTING charges as per clause No- 20 162 GRINDER,5” (A) Replacement of Armature 163 (BReplacement of field coil 164 (C) Replacement of carbon brush 165 (D) Replacement of carbon Holder 166 (E) Replacement of on / off switch 167 GRINDER, 7” (A) Replacementof Armature 168 (B) Replacement of field coil 169 (C) Replacement of carbon brush 170 (D) Replacement of carbon Holder 171 (E) Replacement of on / off switch 172 DRILL M/C, 10MM (A) Replacement of Armature 173 (B) Replacement of field coil 174 (C) Replacement of carbon brush 175 (D) Replacement of carbon Holder 176 (E) Replacement of on / off switch 177 Replacement of burnt connector lead of three phase motor with new lead(glass sleeve insulated) 1 HP to 5 HP 178 7.5 HP to 15 HP 179 20HP TO 30 HP 180 31 HP TO 50 HP 181 60 HP TO 90 HP 182 100 HP TO 150 HP 183 180 HP TO 250 HP 184 AIR BLOWER (A) Replacement of Armature 185 (B) Rewinding of field coil 186 (C) Replacement of carbon brush 187 (D) Replacement of carbon Holder 188 (E) Replacement of on / off switch

Key Value

Document Fees
INR 590 /-
EMD
INR 30000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail