Tender For Testing Of Meters And Relays During Mta, Bhadradri Kothagudem-Telangana

Heavey Water Board-HWB has published Tender For Testing Of Meters And Relays During Mta. Submission Date for this Tender is 06-07-2024. Power Relays Tenders in Bhadradri Kothagudem Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

43916019
Tender For Testing Of Meters And Relays During Mta
Open Tender
Indian
Telangana
Bhadradri Kothagudem
06-07-2024

Tender Documents

Tender Details

Testing Of Meters And Relays During Mta Testing Of Protection Relays And Meters At Captive Power Plant, Hwp(Manuguru) During Mta-2024

Key Value

Document Fees
Refer document
EMD
INR 32040.0 /-
Tender Value
INR 16.02 Lakhs /-

Attachment

FileName File Description File Size
8fb51089-b262-453d-a9d6-33c41c246c06.html Tender Notice 0 KB
BOQ_854486.xls Tender Document 0 KB
Forms_submitted.pdf Tender Document 0 KB
GCC2023.pdf Tender Document 0 KB
Safetyguidelines.pdf Tender Document 0 KB
Techspects.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Testing of protection relays and meters at Captive Power Plant, HWP(Manuguru) during MTA-2024
Sl. No. Item Description
1Item 1: Class IV Relays
23 phase, M/s Areva make,TypeP442 Microprocessor based Distance protection relay.
33 phase M/s Areva make Type P343 relay (TG-4)
43 phase M/s Areva make P111 Non directional Over Current and Earth fault relay (TG-4)
53 phase percentage biased Differential protection relays of Type:RADSB, ASEA make
6Restricted Earth fault relays on LV side of Type RADHD, ASEA make.
73 phase High Impedance Differential relays of Type RADHA, ASEA make
83 phase Over Current/ Earth fault protection relays[3 element]of TypeRXIDF2H,ASEA make
93 phase Directional Over Current / Directional Earth fault/ Reverse power /Low Forward powerTypeRXPE 40/42/47, ASEA make
10Generator Over load protection relays RXIG, ASEA make.
11Generator Minimum Impedance stage I, stage II protection relays of Type RAKIB, ASEA make.
12Generator Out of Step Protection Relay Type RXZP+RXPE, ASEA make.
13Generator Rotor Earth Fault Relay State I, Stage II Type RXNB, ASEA make.
14Generator Stator 0-95%,100% E/F protection relays of Type RAGEA, ASEA make
15Over Fluxing / Loss of Excitation protection relays RAGPC, ASEA make.
16Negative Sequence protection relays of Type RARIB, ASEA make.
17Under Frequency relays of RXFE4, ASEA make.
183 phase Voltage balance scheme / Over Voltage protection relays of Type RXEG21, ASEA make.
19Local Breaker Back up protection relays of Type RAICA, ASEA make
20Schneider make P127 Micom Directional Over Current and Earth fault relay
21ABB make REG 670 (Generator-2)
22ABB make RET 670 (GT-2,UAT-2)
23M/s ABB make SPAF340C3 df/dt
24Check synchronizing relays of Type SKD, EE make
25Check synchronizing relays of Type SKE, EE make
26VAEM Rotor Earth fault relay (TG-4)
27WCDM Reverse power relay (TG-4)
28CAEM Battery Earth fault relays
29Instantaneous differential Protection Relay of CAG type EE make
303 phase Over Current &E/F relaysof Type : SPAJ 140,M/s. ABB make
313 phase inverse type over current relays, type CDG 31/33/63, Egnlish electric make
32Instantaneous under voltage relays on various 6.6 KV, 415 VMCC, type VAGM/VAG English Electric make.
33Motor protection relays oftype SPAM 150, M/S. ABB make
34Check Synchronising Relay Argus-7 2732H33008 of Siemens Make
35SPAD 346C ABB make
36Definite time relay VTT11, English Electric make
37Master trip relay, VAJH/VAJS/VAJHM type, English Electric make
38Neutral displacement relay, Type: VDG, Make:EE
39Item 2: Class III relays
403 phase O/C (inverse) &E/F relay, Type-CDG, Make-EE
41Neutral Displacement relay , Type-VDG, Make-EE
42Instantaneous Differential relay , Type-CAG, Make-EE
43Instantaneous U/V relay , Type-VAG, Make-EE
44Instantaneous O/V relay , Type-VAG, Make-EE
45Definite time Reverse Power relay , Type-CCUM, Make-EE
463 phase O/C (inverse)relay , Type-CDG, Make-EE
47Instantaneous U/V relay , Type-VAGM, Make-EE
48O/C relay(inverse)and E/F relay , Type-CDG, Make-EE
49Item 3: Testing of meters
50AC ammeters of range varying from 0-50 amps to 0-4000 amps with secondaryCT current of 1/ 5 A.
51DC ammeters of range varying from 0-50 amps to 0-1000 amps.
52AC voltmeters of range Varying from 0-220 KV to 0-150 volts with Secondary PT voltage of 110 V or110 /√3 volts or direct 415 volts without PT.
53DC voltmeters of range varying from 0-50 V to 0- 500 V.
54MW Meters of range varying from 0-25 MW to 0-100 MW with CT secondary of 1A or 5A, secondary PT voltage of 110V or 110/√3 volts with transducers of 4-20 mA
55Watt meters of range varying from 630 KWto 2000 KW with CT secondary of 1A Or 5A ,PT Secondary Voltage 110 V or110/√3 Volts.
56Mvar meters of range varying from 0-20 to 0-80MVAR both in lagging and leading side with CT secondary of 1A or 5A, secondary PT voltage of 110V or 110 / √3 volts with transducers of 4-20 mA.
57Frequency meters of range varying from 0-50 Hz, 45-55Hz, 45-0-55Hz with secondary PT voltage of 110 volts.
58Synchronous Scopes with secondary PT voltage of 110 volts.
59KWH meters with CT Secondary of 1A Or 5A, Secondary PT Voltage of 110 V Or 110/√3Volts.
60KVAH meters with CT secondary current of 1A or 5A and PT secondary voltage of 110 Volts or 110/√3 volts.
61KVARH meters with CT secondary current of 1A or 5A and PT secondary voltage of 110 Volts or 110/√3 Volts.
62Power factor meters of both lagging and leading side.