}

Tender For Supply Of Pipes-Ss_As (Welded), panipat-Haryana

Boards / Undertakings / PSU has published Tender For Supply Of Pipes-Ss_As (Welded). Submission Date for this Tender is 18-07-2024. Steel Pipe Tenders in panipat Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

43906366
Tender For Supply Of Pipes-Ss_As (Welded)
Limitted
Indian
Haryana
Panipat
18-07-2024

Tender Details

Supply Of Pipes-Ss_As (Welded) Supply Of Pipes-Ss_As (Welded) For P25 Project At Iocl Panipat Refinery , Supply Of Pipes -Ss Welded To A 358 , Pipe,Efw,Ss, B36.19M, Bw Ends,Sch 10S, Efw, Weld Factor E = 1.00, Pipe A358 Tp304 Cl.1, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,Ss, B36.19M, Bw Ends,Sch 10S, Efw, Weld Factor E = 1.00, Pipe A358 Tp316 Cl.1, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,Ss, B36.19M, Bw Ends,Sch 10S, Efw, Weld Factor E = 1.00, Pipe A358 Tp316 Cl.1, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Supply Of Pipe-Welded Alloy Steel , Pipe,Efw,As, B36.10M, Bw Ends,Sch Std, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.5Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Std, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.5Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Xs, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.5Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Xs, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.5Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Non-Std, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.5Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Non-Std, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.5Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Non-Std, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.5Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Xs, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.9Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As, B36.10M, Bw Ends,Sch Xs, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.9Cr Cl.42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001 , Pipe,Efw,As (H2 Ser.), B36.10M, Bw Ends,Sch 30, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.1 1/4Cr Cl42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001, 2.Additional Requirements For H2 Service, Acc. To Doc. 6745-Pip-000-Ec-0004 , Pipe,Efw,As (H2 Ser.), B36.10M, Bw Ends,Sch Xs, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.1 1/4Cr Cl42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001, 2.Additional Requirements For H2 Service, Acc. To Doc. 6745-Pip-000-Ec-0004 , Pipe,Efw,As (H2 Ser.), B36.10M, Bw Ends,Sch Xs, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.1 1/4Cr Cl42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001, 2.Additional Requirements For H2 Service, Acc. To Doc. 6745-Pip-000-Ec-0004 , Pipe,Efw,As (H2 Ser.), B36.10M, Bw Ends,Sch Non-Std, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.1 1/4Cr Cl42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001, 2.Additional Requirements For H2 Service, Acc. To Doc. 6745-Pip-000-Ec-0004 , Pipe,Efw,As (H2 Ser.), B36.10M, Bw Ends,Sch Non-Std, Efw, Normalized & Tempered, Radiography Shall Be Done, After Stress Relieving, 100% Radiography, Weld Factor E = 1.00, Pipe A691 Gr.1 1/4Cr Cl42, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0001, 2.Additional Requirements For H2 Service, Acc. To Doc. 6745-Pip-000-Ec-0004 => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail