}

Tender For Electrical / Mechanical Work In Sub-Registrar Office And One A.I.G. Unit At District Auraiya, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surf, auraiya-Uttar Pradesh

Boards / Undertakings / PSU has published Tender For Electrical / Mechanical Work In Sub-Registrar Office And One A.I.G. Unit At District Auraiya, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surf. Submission Date for this Tender is 11-07-2024. Electrification Work Tenders in auraiya Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43902227
Tender For Electrical / Mechanical Work In Sub-Registrar Office And One A.I.G. Unit At District Auraiya, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surf
Open Tender
Indian
Uttar Pradesh
Auraiya
11-07-2024

Tender Details

Tender For Electrical / Mechanical Work In Sub-Registrar Office And One A.I.G. Unit At District Auraiya, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group A) 2 Twin Control Point wiring in PVC conduit, with modular type switch :- 3 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular type switch, phenolic laminated sheet, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 4 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 6 Power plug wiring in PVC conduit (4 x 4 Sq.Mm.) :- 7 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvcconduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 8 Circuit / Sub main wiring in PVC conduit :- 9 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 10 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. 11 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 12 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 13 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 14 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire 15 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire 16 S/F light plug point piano type accessories :- 17 Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 18 S/F power plug point piano type accessories :- 19 Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 20 Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosedplug top alongwith 20amps. C curve, SP MCB in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket outlet, and complete with connections, testingandcommissioning etc. as required. 21 S/F modular type electronic fan regulator :- 22 Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 23 S/F modular type blanking plate :- 24 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 25 Supply and fixing offollowingsizes of medium class PVC conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 26 20 mm. 27 25 mm. 28 32 mm. 29 DISTRIBUTION BOARDS & MCBS 30 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 31 single pole 32 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 33 S/F DP MCB Isolator 34 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 35 40 Amps 36 63 Amps 37 S/F TP MCB Isolator 38 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 39 63 amps. 40 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 41 40 amps. 42 63 amps. 43 Supplying and fixingfollowingrating, fourpole, (three phase & neutral)415 volts, residual current circuitbreaker (RCCB), having a sensivity current upto 300 miliamperesinthe existingMCB DB complete withconnections, testing and commissioning etc. as required : 44 63 amps. 45 Supplying and fixing followingway, SP&N, sheet steel,MCB distribution board, 240 V on surface / recess, completewith tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) 46 8 way, Double door 47 Supplying and fixing followingway, horizontal type TP&N, sheet steelMCB distribution board,415 V on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 48 4 way (4 + 12), Double door 49 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 50 4 way (4 + 12), Double door 51 EARTHING SYSTEM 52 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x5 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 53 Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre belowground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm). 54 Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 55 Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required. 56 Providing and fixing 6 SWG dia G.I. wire onsurfaceorin recessfor loop earthing as required. 57 MISCELLANEOUS 58 Providing and fixing M.V. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronFRLSontsideas required. 59 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 60 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 61 2 Pair 62 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable 63 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 64 5/6 A switch 65 3 pin 5/6 A socket outlet 66 Telephone socket outlet 67 Bell push 68 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 69 1 or 2 Module (75mmX75mm) 70 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 71 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 72 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 73 Supplying and fixing Internet Socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 74 ERECTIONOFLIGHTINGFIXTURESANDFANS 75 Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 76 Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 77 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 78 Upto 450 mm sweep 79 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 80 SUPPLY OF LIGHTING FIXTURES 81 Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. 82 Supply of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. 83 Supply of 10 watt Mirror LED light fitting Confirming to IP 65 and above protection Complete in all respect. 84 Suppling of 10 WATT Slim profle surface mounted downlight with options of 700 to 2000 lumen (with accessories). 85 SUPPLY OF CEILING & EXHAUST FANS 86 Supply of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 87 300 mm sweep 88 LT PANEL AND UPS 89 Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. 90 The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in Nos phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with detNosable side covers and shall be suitable for extension on the sides. 91 The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 92 Incoming - 93 200 Amp. MCCB-1 no. 94 Outgoing - 95 32Amp. 10KA FP MCB 5 No. 96 63Amp. 10KA FP MCB 5 No. 97 32Amp. 10KA DP MCB 3 No. 98 CABLE & ACCESSORIES 99 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 100 16 sq. mm 4 core 101 35 sq. mm 3-1/2 core 102 50 sq. mm 3-1/2 core 103 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge. for cable 104 16 sq. mm 4 core 105 35 sq. mm 3-1/2 core 106 50 sq. mm 3-1/2 core 107 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 108 size 16 sq mm 109 size 35 sq mm 110 size 50 sq mm 111 FIRE FIGHTING WORK 112 Fire Extinguishers : 113 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 114 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 115 Fire Sand Bucket : 116 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 117 Supplying and installation of Exit Signs: photo luminescent safety signage made up of photo luminescent material of rare earth aluminates, non radioactive working on the principle of high energy for safety signs with monograms processed on 1.2 mm thick aluminum sheet including arrangement for fixing on wall / ceiling etc. complete as required (single sided) (size 150 mm x 300 mm) 118 TOILET BLOCK 119 Point wiring in PVC conduit, with modular type switch :- 120 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group A) 121 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 122 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 123 Circuit / Sub main wiring in PVC conduit :- 124 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 125 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. 126 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 127 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 128 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 129 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire 130 S/F light plug point piano type accessories :- 131 Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 132 S/F power plug point piano type accessories :- 133 Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 134 Supply and fixing offollowingsizes of medium class PVC conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 135 25 mm. 136 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 137 single pole 138 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 139 S/F DP MCB Isolator 140 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 141 40 Amps 142 63 Amps 143 Supplying and fixing followingway, horizontal type TP&N, sheet steelMCB distribution board,415 V on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 144 6 way (4 + 18), Double door 145 Providing and fixing M.V. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronFRLSontsideas required. 146 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 147 5/6 A switch 148 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 149 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 150 ERECTIONOFLIGHTINGFIXTURESANDFANS 151 Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 152 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 153 Upto 450 mm sweep 154 SUPPLY OF LIGHTING FIXTURES 155 Supply of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. 156 Supply of 10 watt Mirror LED light fitting Confirming to IP 65 and above protection Complete in all respect. 157 Suppling of 10 WATT Slim profle surface mounted downlight with options of 700 to 2000 lumen (with accessories). 158 SUPPLY OF CEILING & EXHAUST FANS 159 Supply of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 160 300 mm sweep 161 CABLES SUPPLY 162 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 163 16 sq. mm 4 core 164 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 165 16 sq. mm 4 core 166 GUARD ROOM 167 Point wiring in PVC conduit, with modular type switch :- 168 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group A) 169 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 170 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 171 Circuit / Sub main wiring in PVC conduit :- 172 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 173 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. 174 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 175 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 176 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire 177 S/F light plug point piano type accessories :- 178 Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 179 S/F power plug point piano type accessories :- 180 Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 181 S/F modular type electronic fan regulator :- 182 Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 183 Supply and fixing offollowingsizes of medium class PVC conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 184 25 mm. 185 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 186 single pole 187 S/F DP MCB Isolator 188 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 189 40 Amps 190 63 Amps 191 Supplying and fixing followingway, horizontal type TP&N, sheet steelMCB distribution board,415 V on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 192 6 way (4 + 18), Double door 193 Providing and fixing M.V. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronFRLSontsideas required. 194 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 195 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 196 5/6 A switch 197 3 pin 5/6 A socket outlet 198 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 199 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 200 ERECTIONOFLIGHTINGFIXTURESANDFANS 201 Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 202 Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 203 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 204 SUPPLY OF LIGHTING FIXTURES 205 Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. 206 Suppling of 10 WATT Slim profle surface mounted downlight with options of 700 to 2000 lumen (with accessories). 207 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 208 16 sq. mm 4 core 209 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 210 16 sq. mm 4 core 211 GENERATOR ROOM 212 Point wiring in PVC conduit, with modular type switch :- 213 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group A) 214 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 215 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 216 Circuit / Sub main wiring in PVC conduit :- 217 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 218 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. 219 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 220 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 221 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire 222 S/F light plug point piano type accessories :- 223 Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 224 S/F power plug point piano type accessories :- 225 Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 226 S/F modular type electronic fan regulator :- 227 Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 228 Supply and fixing offollowingsizes of medium class PVC conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 229 25 mm. 230 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 231 single pole 232 S/F DP MCB Isolator 233 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 234 40 Amps 235 63 Amps 236 Supplying and fixing followingway, horizontal type TP&N, sheet steelMCB distribution board,415 V on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 237 6 way (4 + 18), Double door 238 Providing and fixing M.V. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronFRLSontsideas required. 239 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 240 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 241 5/6 A switch 242 3 pin 5/6 A socket outlet 243 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 244 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 245 ERECTIONOFLIGHTINGFIXTURESANDFANS 246 Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 247 Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 248 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 249 SUPPLY OF LIGHTING FIXTURES 250 Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. 251 Suppling of 10 WATT Slim profle surface mounted downlight with options of 700 to 2000 lumen (with accessories). 252 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 253 16 sq. mm 4 core 254 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 255 16 sq. mm 4 core 256 CANTEEN 257 Point wiring in PVC conduit, with modular type switch :- 258 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group A) 259 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 260 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 261 Circuit / Sub main wiring in PVC conduit :- 262 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 263 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. 264 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 265 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 266 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 267 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire 268 S/F light plug point piano type accessories :- 269 Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 270 S/F power plug point piano type accessories :- 271 Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 272 Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosedplug top alongwith 20amps. C curve, SP MCB in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket outlet, and complete with connections, testingandcommissioning etc. as required. 273 S/F modular type electronic fan regulator :- 274 Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 275 Supply and fixing offollowingsizes of medium class PVC conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 276 25 mm. 277 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 278 single pole 279 S/F DP MCB Isolator 280 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 281 40 Amps 282 63 Amps 283 Supplying and fixing followingway, horizontal type TP&N, sheet steelMCB distribution board,415 V on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 284 6 way (4 + 18), Double door 285 Providing and fixing M.V. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronFRLSontsideas required. 286 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 287 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 288 5/6 A switch 289 3 pin 5/6 A socket outlet 290 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 291 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 292 ERECTIONOFLIGHTINGFIXTURESANDFANS 293 Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 294 Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 295 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 296 SUPPLY OF LIGHTING FIXTURES 297 Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. 298 Supply of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. 299 Supply of 10 watt Mirror LED light fitting Confirming to IP 65 and above protection Complete in all respect. 300 Suppling of 10 WATT Slim profle surface mounted downlight with options of 700 to 2000 lumen (with accessories). 301 CABLES SUPPLY 302 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 303 16 sq. mm 4 core 304 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 305 16 sq. mm 4 core 306 EXTERNAL LIGHTING WORK 307 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 308 6 sq. mm 4 core 309 16 sq. mm 4 core 310 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge. for cable 311 6 sq. mm 4 core 312 16 sq. mm 4 core (28 mm) 313 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 314 6 sq. mm 315 16 sq. mm 316 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 317 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. CAT AAA 318 Supply and fixing following capacity of automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors, HRC fuse, isolating switch, metering instrument and instrument box with CTs etc.complete in all respect. 40 A TPN (For Street Light) 319 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x5 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 320 Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre belowground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm). 321 Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 322 Providing and fixing 6 SWG dia G.I. wire onsurfaceorin recessfor loop earthing as required. 323 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 324 300 mm dia 325 TRANSFORMER WORK 326 Providing, erecting, testing & commissioning approved make oil immersed naturally ONAN cooled, double wound, core type outdoor copper wound 11 kV/ 433 Volts Step Down Transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed and Off Load Tap Changer continuously rated for a full temperature rise in oil not exceeding 40 deg. C at maximum ambient temp. Of 50 deg. C complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with I.S. 1180 LEVEL 2 standards OFF load tap changing range steps -10% to 5% on H.V in steps of 2.50% .and L.V. for variation should be provided The H.V. shall be connected delta & secondary with star connection. The transformer should have cable-end boxes on H.T. side & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from manufacturers. Losses As per IS 1180 LEVEL-2. 327 1. Coservator with plain oil level gauge and oil drain plug 1nos.2. Top filter valve 1 Nos.3. Bottom filter-Cum-drain valave 1Nos..4. Rating and diagram plate 1nos.5. Earthing Terminals 2Nos.6. Thermometer pockets 1Nos.7. Lifting Lugs 2/4 Nos.8.Air release plug 2/4 Nos.9. Bi-directional rollers 4Nos.10.Jacking pads 1Nos.11.Presure relese valve 1Nos.12. Separate Bare LV neutral 433V 13. Detachable/Fixed type radiators 1Nos.14. Magnet Oil levelgauge15. Oil temperature indicator 1Nos.16. Winding temperature indicator 1Nos.17. Marshlig Box single window 1No.18. Double flot buchholzs relaywith alarm and trip contact.Copper Wound 100KVA 11/.433V

Key Value

Document Fees
INR 1770 /-
EMD
INR 64000.0 /-
Tender Value
INR 30.40 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail