Tender For Repair/Maintenance To Lt Oh Line, Lt Cabels, Lt Panels And Other Connected Works At Mtn Bde, Mbsc, Station Hq,Ad Pl Asc, Engr Regt, Ifsu,Iv Det Cisu, Fd Regt, Jak Rif Garh Rif, Apjd Jong And Maratha Ground Of Age E/M Under Area Of Ge 859 Ews; 1 Dismantling and taking up or down old Unserviceable service cable and LT UG cable of any size complete all as specified and directed 2 Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core. 3 All as per Item No 2 above but 25 Sqmm 3.5 Core. 4 All as per Item No 2 above but 35 Sqmm 3.5 Core. 5 All as per Item No 2 above but 50 Sqmm 3.5 Core. 6 All as per Item No 2 above but 70 Sqmm 3.5 Core. 7 All as per Item No 2 above but 95 Sqmm 3.5 core. 8 All as per Item No 2 above but 120 Sqmm 3.5 core. 9 Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. not exc 10 sq m on plan and not exc 1.5m in depth and getting out in soft & loose soil complete all as specified and directed. 10 Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for any type of soil complete all as specified and directed. 11 Removing excavated soil not exc. 50 m and depositing where directed at a layers not exc 25 Cm. above/below the starting point complete all as specified and directed. 12 Supply and laid in trenchesdouble walled corrugated HDPE pipes of inner dia 50 mm, as in cable protection work, complete all as specified and directed. 13 Supply and laid in trenchesdouble walled corrugated HDPE pipes of inner dia 65 mm , as in cable protection work, complete all as specified and directed. 14 Supply and fixingin replacement MCCB 4 Pole, 415 V,160 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed. 15 Supply and fixingin replacement MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed. 16 Supply and fixingin replacement MCCB 4 Pole, 415 V,63 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed. 17 Materials and labour for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion complete all as specified and directed. 18 Material and labour for purning of tree branches which is touches on LT/HT over head conductor complete all as specified and directed. 19 Materials and labour for replacement of GI pipe light grade with all fittings complete grouted in ground all as specified for 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed. 20 Materials and labour for replacement GI pipe light grade with all fittings complete grouted in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed. 21 Materials and labour for replacement GI pipe light grade with all fittings complete grouted in ground all as specified for80 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed. 22 Dismantling of old unserviceable steel poles of any size after disconnecting power, keeping aside serviceable insulators, stays, clamps etc for reuse complete all as specified and directed. 23 Supply and fixingin replacement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres Long)complete all as specified and directed. 24 Dismantling of old ACSR or AAC Conductor all as directed by the Engr-in charge. 25 Dismantling of insulator any type, any size all as directed by the Engr-in charge. 26 Supply and fixing for replacement of pin type insulator, porcelain, vitreous, white,brown or green including one galvanised mild steel spindle two GI washer and one GI nut150mm height, 150mm dia for 11000 Volt grade complete all as specified and directed. 27 Supply and fixing for replacement of disc insulator, porcelain, vitreous, 145nm high and 225 mm dia ball & socket type, with tension clamp suitable for conductor single disc assy working pressure 11000 volts complete all as specified and directed. 28 Supply and fix Shackle type insulator, ISI marked, porcelain, vitreous white, 1100 volts grade of size 75 x 90 mm, including galvanized mild steel straps 31x3 mm,washers, insulators bolts (12 mm dia), washers and nuts complete all as specified and as directed. 29 Dismantling of old unserviceable, broken, unused steel tubler pole of any size and specification (Note:- The rate inclussive of excavation if needed, cutting of pole at ground level and removal from site complete all as specified and as directed. 30 Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement all as directed by the Engr-in-charge. 31 Materials and labour for Air break, gange operated switch HT 11000 volts, Triple pole , mounted on insulators and steel frames with operating mechanism worked from ground level with operating rod, handle etc., for current rating upto 400 amps fixed on pole / structures complete all as specified and as directed by the Engr-in charge. 32 Materials and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in foundation filling and mass concrete (for foundation bed concrete in stays /poles or any other position as directed at site). 33 Materials and labour for PCC (1:2:4) type B-1 using 20 mm graded broken stone aggregate as in mass concrete in coping of existing and new PCC/steel poles etc complete all as specified and directed. 34 Dismantling stay assembly complete including demolition of concrete etc and excavation as required complete all as specified and directed. 35 Supply and fixing Stay assembly complete with accessories for dia of stay rod 20mm as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) 36 Materials and labour for Loop type insulator, vitreous porcelain, white, brown or green: Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed. 37 Materials and labour for Galvanised stay strand,7/3.15mm complete all as specified and directed. 38 Materials and labour for Painting of Steel tubuler pole up to 9 mtr long by using Two coats of aluminium paint with one coat of red oxide primer including preparation of surface all as directed by the Engr- in-charge. 39 Supply and fixing in repair LT Over over head line phase seperator of any size (4 way) in between distribution span of LT over head lines all as directed by the Engr-in-charge. 40 Supply and fixing in repair LT Over over head line phase seperator of any size (2 way) in between distribution span of LT over head lines all as directed by the Engr-in-charge. 41 Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories, Outdoor type suitable for size 10 to 16 sqmm 3.5/4 Core. 42 All as per Item No 41 above but 25 to 50 sqmm 3.5/ 4 Core. 43 All as per Item No 41 above but 70 to 120 sqmm 3.5/ 4 Core. 44 Supply and fix Off Load changeover switch side handle in sheet metal enclosure 415 V AC 50 Hz of Capacity 63 Amp 4 pole all as directed by the Engr-in-charge.Make : Havells, L&T and its equivalent 45 Supply and fix Off Load changeover switch side handle in sheet metal enclosure 415 V AC 50 Hz of Capacity 100 Amp 4 pole all as directed by the Engr-in-charge.Make : Havells, L&T and its equivalent 46 Materials and labour for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for LT CABLE 1100 VOLTS embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed. 47 Laying only old serviceable XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core. 48 All as per Item No 47 above but 16 Sqmm 2 Core. 49 All as per Item No 47 above but 16 Sqmm 4 Core. 50 All as per Item No 47 above but 25 Sqmm 4 Core. 51 All as per Item No 47 above but 35 Sqmm 3.5 Core. 52 Supply and fixing in repair aluminium lugs for 10 Sqmm size complete all as specified and directed. 53 All as per Item No 52 above but 16 Sqmm. 54 All as per Item No 52 above but 25 Sqmm. 55 All as per Item No 52 above but 35 Sqmm. 56 All as per Item No 52 above but 50 Sqmm. 57 All as per Item No 52 above but 70 Sqmm. 58 All as per Item No 52 above but 95 Sqmm. 59 All as per Item No 52 above but 120 Sqmm. 60 Locating electrical fault in UG cable of any size and repair by using of suitable size of cable lugs and straight through joint and make the good disturbed surfaces all as specified and directed by Engr-in-charge.Note :- Cable joint kit, Earth work & Aluminium lugswill be measured and paid seperately in respective items.