}

Tender For Supply Of Strainers, panipat-Haryana

Boards / Undertakings / PSU has published Tender For Supply Of Strainers. Submission Date for this Tender is 22-07-2024. Bolts Tenders in panipat Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

43862923
Corrigendum : Tender For Supply Of Strainers
Limitted
Indian
Haryana
Panipat
22-07-2024

Tender Details

Supply Of Strainers Supply Of Strainers For P25 Project At Iocl Panipat Refinery , Supply Of Strainers , Strainer Y-Type,Cs, 150,0, Mfg. Std., Flgd,B16.5,Rf, Bolted Cover,Removable Screen, Perforated Plate Astm E674, Mesh Astm E2016, Mesh Size40 Mesh, Shall Be Provided With 3/4, Threaded Tap And Solid, Threaded Plug As Drain Conn., A216 Gr.Wcb, Str.Element Ss 304, Etsp Wd Ss316 + Grph, A193 Gr.B7/A194gr.2H, Cover A216 Gr.Wcb, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Clear Strainer Area To Nominal Area, Ratio Shall Be 3(At Unclogged Condition) , Strainer Y-Type,Cs, 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen, Perforated Plateastm E674, Meshastm E2016, Mesh Size40 Mesh, A105n, Internals Ss304, Etsp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Clear Strainer Area To Nominal Area, Ratio Shall Be 3(At Unclogged Condition) , Strainer Y-Type,Cs, 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen, Perforated Plateastm E674, Meshastm E2016, Mesh Size40 Mesh, A105n, Internals Ss304, Etsp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Clear Strainer Area To Nominal Area, Ratio Shall Be 3(At Unclogged Condition) , Strainer Y-Type,Cs, 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen, Perforated Plateastm E674, Meshastm E2016, Mesh Size40 Mesh, A105n, Internals Ss304, Etsp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Clear Strainer Area To Nominal Area, Ratio Shall Be 3(At Unclogged Condition) , Strainer Y-Type,Cs (Nace), 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen, Perforated Plateastm E674, Meshastm E2016, Mesh Sizemesh 40, A105n, Internals Ss 316L, Etsp Wd Ss316+Grph, A193gr.B7m/A194gr2hm, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005, 3.Clear Strainer Area To Nominal Area, Ratio Shall Be 3(At Unclogged Condition) , Strainer Y-Type,Ss, 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen, Perforated Plate Astm E674, Meshastm E2016, Mesh Sizemesh, A182 Gr.F304, Internals Ss 304, Etsp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Clear Strainer Area To Nominal Area, Ratio Shall Be 3(At Unclogged Condition) , Strainer Y-Type,Ss, 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen, Perforated Plateastm E674, Meshastm E2016, 60 Micron Filter Element, A182 Gr.F316, Internals Ss 316, Etsp Wd Ss316+Grph, A193gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002 , Strainer Y-Type,As, 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen, Perforated Plateastm E674, Meshastm E2016, Mesh Size40 Mesh, A182 Gr.F9, Internals Ss 316, Etsp Wd Ss316+Grph, A193 Gr.B16/A194gr.4, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002 , Strainer Y-Type,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Y Type , Removable Screen,, Perforated Plate Astm E674, Mesh Astm E2016, Mesh Size40 Mesh, A105n, Internals Ss304, Etsp Wd Ss316 + Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required, 3.Clear Strainer Area To Nominal Area, Ratio Shall Be 3(At Unclogged Condition) , Basket Strainer,Ss, 300,0, Mfg. Std., Flgd,B16.5,Rf, Designbasket Type, Drain & Vent Conn. 2,Flgd,Rf, The Drain Shall Be Provided At, The Side Of The Strainer At, The Bottom., Meshastm E2016, Meshmesh 40, Perforated Plate Astm E674, Refer Annexure-1, A351 Gr.Cf8m, Wn Flg A182 Gr.F316, Top Covera182 Gr.F316, Spwd Ss316 + Grph, A193 Gr.B7/A194gr.2H, Screen Ss 316, Other Inter.Equivalent To, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002 , Basket Strainer,As (H2 Ser.), 300,0, Mfr. Std., Flgd,B16.5,Rf, Designbasket Type, Drain & Vent Conn. 2,Flgd,Rf, The Drain Shall Be Provided At, The Side Of The Strainer At, The Bottom., Normalized & Tempered,, Meshastm E2016, Meshmesh 40, Perforated Plate Astm E674, Refer Annexure-1, A234 Gr.Wp11-W Cl.1, Wn Flg A182 Gr.F11 Cl.2, Blind Flga182 Gr.F11 Cl.2, Spwd Ss316 + Grph, A193 Gr.B16/A194gr.4, Screen Ss 316, Other Inter.Equivalent To, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Additional Requirements For H2 Service, Acc. To Doc. 6745-Pip-000-Ec-0004 , Strainer T-Type,Cs, 150,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area , Strnr T-Type,Cs,Int Epoxy Coat, 150,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, Internalepoxy Coated, A234 Gr.Wpb-W, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.For Internal Coating Requirements, Refer Doc. 6745-Pip-000-Ec-0023 , Strnr T-Type,Cs,Int Epoxy Coat, 150,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, Internalepoxy Coated, A234 Gr.Wpb-W, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.For Internal Coating Requirements, Refer Doc. 6745-Pip-000-Ec-0023 , Strnr T-Type,Cs,Int Epoxy Coat, 150,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, Internalepoxy Coated, A234 Gr.Wpb-W, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.For Internal Coating Requirements, Refer Doc. 6745-Pip-000-Ec-0023 , Strnr T-Type,Cs,Int Epoxy Coat, 150,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, Internalepoxy Coated, A234 Gr.Wpb-S, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.For Internal Coating Requirements, Refer Doc. 6745-Pip-000-Ec-0023 , Strnr T-Type,Cs,Int Epoxy Coat, 150,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, Internalepoxy Coated, A234 Gr.Wpb-S, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.For Internal Coating Requirements, Refer Doc. 6745-Pip-000-Ec-0023 , Strainer T-Type,Cs (Nace), 150,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss 316L, Sp Wd Ss316+Grph, A193gr.B7m/A194gr2hm, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Strainer T-Type,Cs (Nace), 150,0, Tkuipl Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss316, Sp Wd Ss316+Grph, A193gr.B7m/A194gr2hm, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Strainer T-Type,Cs, 150,0, Tkis Drawing, Bw Ends,Sch Xs, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area , Strainer T-Type,Cs, 300,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area , Strainer T-Type,Cs, 300,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area , Strainer T-Type,Cs (Nace), 300,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss316l, Sp Wd Ss316+Grph, A193gr.B7m/A194gr2hm, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Strainer T-Type,Cs (Nace), 300,0, Tkuipl Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss316, Sp Wd Ss316+Grph, A193gr.B7m/A194gr2hm, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area, 4.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Strainer T-Type,Cs, 300,0, Tkis Drawing, Bw Ends,Sch Xs, Designdrawer Type, Flanged Cover, A234 Gr.Wpb-S, Internals Ss304, Sp Wd Ss316+Grph, A193 Gr.B7/A194gr.2H, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area , Strainer T-Type,As, 300,0, Tkis Drawing, Bw Ends,Sch Std, Designdrawer Type, Flanged Cover, Normalized & Tempered, A234 Gr.Wp9-S Cl.1, Internals Ss 316, Gasksp Wd Ss316+Grph, A193 Gr.B16/A194gr.4, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area , Strainer T-Type,As, 300,0, Tkis Drawing, Bw Ends,Sch Xs, Designdrawer Type, Flanged Cover, Normalised And Tempered, A234 Gr.Wp9-S Cl.1, Internals Ss 316, Gasksp Wd Ss316+Grph, A193 Gr.B16/A194gr.4, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area , Strainer T-Type,As, 600,0, Tkis Drawing, Bw Ends,Sch 160, Designdrawer Type, Flanged Cover, A234 Gr.Wp9-S Cl.1, Internals Ss 316, Gasksp Wd Ss316+Grph, A193 Gr.B16/A194gr.4, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2. For Strainer Dimensional Details, Refer Doc. 6745-Pip-000-Tb-0008, 3.Mesh 5 With 0.041 In. Dia. Wire And 63%, Open Area. The Effective Area Of The, Screen Assembly Shall Not Be Less Than, 150% Of The Pipe Cross Sectional Area => Limited

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-07-2024 Addendum_1_PI83_Tech_Clar1 Technical Bid 15-07-2024
2 16-07-2024 Addendum_2_PI83_Extn1 Date 22-07-2024

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail