Tender For Construction Of Deficient Omqs And Smqs At Af Station Bkt (Phase-I) ; 1 SCHEDULE A PART I (BUILDING WORKS) 2 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . 3 Sch A Part II (INTERNAL WATER SUPPLY) 4 Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II. 5 Sch A Part III (INTERNAL ELECTRIFICATIONS) 6 Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part III . 7 Sch A Part IV (EXTERNAL WATER SUPPLY) 8 Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV . 9 Sch A Part V (EXTERNAL ELECTRIC SUPPLY) 10 Lump sum price worked out by the contractor for External Electric sUPPLY as listed in Sch ‘A’ Part V. 11 Sch A Part VI (SEWAGE DISPOSAL) 12 Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI. 13 Sch A Part VII (AREA DRAINAGE) 14 Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII 15 Sch A Part VIII(ROAD/PATH/CULVERT) 16 Lump sum price worked out by the contractor for ROAD/PATH/CULVERT as listed in Sch ‘A’ Part VIII 17 Sch A Part IX (FENCING & GATE) 18 Lump sum price worked out by the contractor for Fencing & Gate as listed in Sch ‘A’ Part IX 19 Sch A Part X (SITE CLEARANCE) 20 Lump sum price worked out by the contractor for Site Clearance as listed in Sch ‘A’ Part X 21 Sch A PartXI (Miscellaneous Items of B/R and E/M) 22 M&LConstruction of RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 Design Mix in walls, Base slab, Baffle walls and Roof slab including beams etvc with Vent shaft, manhole opening with cover connectetion etc, complete with effective dcepth of 1.5 meter and overall depth of 3 mtr for 50 user complete all as shown in TD drawing,as specified and directed. 23 M&L Material & labour for construction of soakage well ofsize 2.4 mtr dia X 4.5 mtr effective depth, in ordinary soil,foundation in PCC 1:3:6, wells, of honey combedand solid in M-25 concreteincluding intercepting chamber screen chamber brick work in CM, RCC cover slab in M-25 /Brick work /filling with brick bats, completeall as shown in TD drawing and as directed. 24 Supply and laying well burnt sub class B bricks, locally available laid in trenches for protection of undergroung cable complete all as specified and directed. 25 Material and Labour for supply, installation, commissioning and testing of outdoor type LT panel (CPRI type tested Approved) made out of 3.15 mm thick CRCA sheet, double door made out of MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase &neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incomming and outgoing cable complete all as specified & directed by Engineer-in-Charge of suitable sizes for following :-Incoming:(a) MCCB 400 Amps, 36 KA. 3 Phase, 4 pole, 415 volts, fixed type, Ics, 100% Icu -01 No(b) Ammeter96x96mm, square, digital type with selector switch and CTs -01 set(c) Voltmeter 0-500V, digital type, 96x96mm, square with selector switch- 1 set(d) LED indicator lamp(R-Y-B)- 1 setOutgoing: -(a) MCCB 320 Amps, 36 KA. 3 Phase, 4 pole, 415 volts, fixed type, Ics, 100% Icu -01 No(b) MCCB 125 Amps, 25 KA. 3 Phase, 4 pole, 415 volts, fixed type, Ics, 100% Icu -01 No 26 Material and Labour for supply, installation, commissioning and testing of outdoor type LT panel (CPRI type tested Approved) made out of 3.15 mm thick CRCA sheet, double door made out of MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 200 amps on phase &neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incomming and outgoing cable complete all as specified & directed by Engineer-in-Charge of suitable sizes for following :-Incoming:(a) MCCB 125 Amps, 25 KA. 3 Phase, 4 pole, 415 volts, fixed type, Ics, 100% Icu -01 No(b) Ammeter96x96mm, square, digital type with selector switch and CTs -01 set(c) Voltmeter 0-500V, digital type, 96x96mm, square with selector switch- 1 set(d) LED indicator lamp(R-Y-B)- 1 setOutgoing:(a) MCCB 63 Amps, 16 KA. 3 Phase, 4 pole, 415 volts, fixed type, Ics, 100% Icu -01 No(b) MCCB 32 Amps, 16 KA. 3 Phase, 4 pole, 415 volts, fixed type, Ics, 100% Icu -01 No(c) MCB 32 Amps, 10 KA,2 pole, 230 volts -01 No(d)Analogue time switch 16 Amps- 01 No(e)Dial type DIL rail mounting analog time switch 16 amp / 230 volt 50 hz battery back up 24 hrs programmable type with 01 NO and 1 NC contact - 01 No (for security light)(f)Three way bakelite strip type cable connec tor 30 amp rating-04 Nos 27 Supply, install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4/6 Nos energy meters of overall dimension 1200mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thickCRCASheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-(a) Four pole MCB, 100 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.(b) Copper Bus Bar of size 25mm x 3.0mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.(c) MCB TPN 32 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters)(d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)(e) Analog time switch 16 Amp-01 No(f) LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos.(g) 3 Way Bakelite strip type cable connector 30 Amps rating - 04 Nos(h) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up,24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light).(j) Internal wiringwith 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :-(i) MCCB to Bus Bar - Bus bar link(ii) Bus Bar to Cable Connector via KWh meter and MCB - 10 Sqmm(iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm(iv) Space for accommodated 3 phase 4 wire electric smart meter - 04 Nos(v)Copper earth bar 28 Supply, install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4/6 Nos energy meters of overall dimension 1200mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thickCRCASheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-(a) Four pole MCB, 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.(b) Copper Bus Bar of size 25mm x 3.0mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.(c) MCB TPN 32 Amps, 10 KA - 2 Nos ( To be connected with 2 Nos Meters)(d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)(e) Analog time switch 16 Amp-01 No(f) LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos.(g) 3 Way Bakelite strip type cable connector 30 Amps rating - 04 Nos(h) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up,24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light).(j) Internal wiringwith 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :-(i) MCB to Bus Bar - 10.0 Sqmm copper(ii) Bus Bar to Cable Connector via KWh meter and MCB - 10 Sqmm(iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm(iv) Space for accommodated 3 phase 4 wire electric smart meter - 02 Nos(v)Copper earth bar 29 M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to galvanised iron strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron or steelconnected to earthing test point all as specified incl 40 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.Note :- (i) GI strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm th, fixed with necessary nuts and boltson angle iron of size 40X40x5mm, 60cm long and grouted with PCC block of size 200x200x250mm(PCC 1:3:6 using 20mm grade stone aggregate including necessary earth work for marking the result and purpose. 30 M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate not less than 1.50 m below ground levelsurrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test pointetc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SI Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. 31 M&L for boring of holes under road, pavement, hard standing Pneumatic tools / manually technology and necessary machinary incl HDPE pipe of size 150mm dia suitable for 0.4 mpa working pressure complete and making good complete all as specified and directed. 32 Supply & fixing bldg/poles light bracket made out 32 mm dia bore G.I pipe, light grade of length not less than 1.5 Mtr, bend to required shape for holding the fitting including clamps 50x6 mm flat iron ,nuts & bolts for supporting the brackets including aluminium paintcomplete all as specified and directed. 33 Supply, installation, commissioning and testing cubical panel board of size 600x600x300mm, 3 phase 4 wire 415 volts AC 50 Hz, factory made indoor type fabricated with 2mm thick CRCA sheet dust and vermin proof duly powder coating painted over a coat of red oxide primer having bus bar chamber with 4 Nos 250 Amps copper bus bar on apoxi insulator 1100 volts grade, mounted on angle iron frame made out of 40x40x5mm angle iron 300mm high above floor level and grouting 150mm in PCC on all four corners with and including internal connections using copper cable / wire/ bus bar all as specified and directed. complete all as specified and directed. 34 Shifting of transformer HT 11 KV, three phase, LT 433 volt, capacity upto 200 KVA using man power / crane / transport vehicle to required location within AF Station BKT complete all as directed.NOTE: For shifting of transformer from existing location to new location shall be required mechanical instrument such as crane & vehicles including loading / unloading etc. The unit quoted rate shall be deemed to included the cost of all T&P labour etc. 35 Material and labour for cutting cast iron GI water mains and earth work for tapping and reducing to required length in position for insertion of new tee for branch connection of the internal dia pipe including supply and fixing new tee upto 150x150x80mm of coller double side end socket and one side end flanged of using required lead joint all as specified and directed. 36 Material and labour for construction of new valve chamber size 900mmx900mmx750mm (Type B) (internal dimension) including necessary earth work in any type of soil, PCC foundation (1:3:6) type C2, 40 mm graded stone aggregate as in base concrete, brick work in CM 1:6 with 15 mm thick plaster internally and 15 mm thick externally in (upto 15 cm below NGL) CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40x40x5 mm MS angles complete with 2 coat of synthetic enamel paint over one coat of red oxide primer on all metal works and three coats of white wash on all plastered surface of valve chambers complete all as specified & directed. 37 M & L Supply and fix Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provn of LED bulb rechargable 10 watts with 3 hours Battery Back upcomplete all as specified and directed. 38 Taking out old under ground XLPE cable of size 240 Sqmm 3.5 core from trenches/fixed to wall/floor complete all as specified and directed.Note: Earthwork,shall be measured and paid separately under relevant items of schedule. 39 Relaying of old sreviceable LT UG cable of size 150 sqmm 3.5 core in trenches / fixed to wall / floor all as specified and directed. complete all as specified and directed.Note: Earthwork, Sand cushioning, brick/PCC cover, G.I. pipe shall be measured and paid separately under relevant items of schedule. 40 Relaying of old sreviceable LT UG cable of size 150 sqmm 3.5 core in trenches / fixed to wall / floor all as specified and directed. complete all as specified and directed.Note: Earthwork, Sand cushioning, brick/PCC cover, G.I. pipe shall be measured and paid separately under relevant items of schedule. 41 Material and laboujr for telephone point wiring with twin core telepbhone wire complete all as specified and directed. 42 Supply installation and testing of AC static direct connected watt hour smart three phase meter of prepayment features with the followings specifications : - (a)AC three Phase four wire, Tamber proof, static meter of class 10, 415V, 50Hz, 10A-60A confirming to ISO-16444:2015 (Reaffimed 2020) and relevent IEC standards with hybrid (GPRS+RF) communication facility, anti-temper features, Microprocessor and LED/LCD based circuit.(b) Meter should support sending the following data : 15/30 min instantaneous data for voltage current, power factor, power, cumulative energy and frequency, monthly billing, survey for cumulative Energy and max Demand to Software (c) Meter should support open communication protocol DLMS with the software. Note:More than 33% of a particular make to ensure interchangeability. 43 Supply & fix electric , 230 volt AC SP wall mounted kitchen chimney, black finish stainless steel, filter less auto clean dynamic air flow easy to clean with LED 2 watt light lamp to illuminate the top area 3 speed touch and motion control suction cap 1000 cum per hour, FRP housing and fan of flame retarded plastic, low noise, smooth movement suitable size to accommodate 2-4 burner including flexible aluminum exhaust pipe max 3 mtr long complete all as specified and directed, Make Glen/ Faber/ Hindware-06 Each 44 Supply and fixing LED Bulb 9/10 watt complete all as specified and directed. 45 Supply and fixing cable juntion box with new pole mounted thermoplastic cable junction box for street light 4.5 module with IP-65 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of approx size 126 mm X 288 mm x 111 mm with front door opening system including terminals for one incoming and two outgoing cable of size 16/25 sqmm 4 core, one MCB SP 3 to 6 Amp 240 V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed. 46 Supply and fix wall mixture 15 mm bore for hot and cold mixing arrangement, with provision for tap and overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges etc complete all as specified and directed. 47 Supply and fix angle valve quarter turnof 15 mm bore dia chromium plated fancy typescrewed both ends for iron pipes or for brass ferrule complete all as specified and directed.etc complete all as specified and directed.Make :-Jaquar cat part No FLR-5053N or equilavent make in Hindware / Kohler 48 Supply and fix of Brass Chromium plated shower rose with swivel joints and shower arm 300mm long complete all as specified.Make : Jaquar Cart Part No. OHS-1619 or equivalent make in Hindware/ Kohler 49 Supply and fix of Wash Hand Basin mixer including Hot and Cold mixer arrangement with 450mm long braided Hoses complete all as specified.Make : Jaquar Cart Part No. ARI-39005B or equivalent make in Hindware/ Kohler 50 “M&L for sign board of size 900mm x 900mm made of 2mm thick aluminium sheet and the board shall be covered using retro reflective sheet of blue clour and the letters on it shall be of white colour on both side.The board shall be supporrted by 32mm bore stainless steel 304 SS grade round pipe & 25X12mm tublar pipe and fix overstainless steel post pipe of dia 63.5 mm 304 SS grade 2.5 m long including necessary work of cutting, welding, nuts, bolts, anchor plates etc. with fixing by PCC 1:2:4 Type B1(using 20 mm graded stone aggregate) cast in situ of each leg post in various loction for fixing of sign boards including necessary earth work complete all as specified and as directed by Engr-in-charge. 51 Deduct Schedule of Credit of Rs. 1350.00 as brought out from Sr Page No.of tender