| 1 | GIS SUPPLY: 400KV, 3150A, 63 kA, SF6 GIS BUS BAR MODULE (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 2 | GIS SUPPLY: 400KV, 63 kA, SF6 BUS PT BAY MODULE (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 3 | GIS BAY SUPPLY: 400kV, 3150A, 63 kA, SF6 GIS GT FEEDER BAY MODULE (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 4 | GIS BAY SUPPLY: 400kV, 3150A, 63 kA, SF6 GIS ST FEEDER BAY MODULE (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 5 | GIS BAY SUPPLY: 400kV, 3150A, 63 kA, SF6 GIS LINE FEEDER BAY MODULE (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 6 | GIS BAY SUPPLY: 400kV, 3150A, 63 kA, SF6 GIS LINE FEEDER BAY MODULE FOR INTERCONNECTION WITH EXISTING SWITCHYARD (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 7 | GIS BAY SUPPLY: 400kV, 3150A, 63 kA, SF6 GIS TIE FEEDER BAY MODULE (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 8 | GIS BAY SUPPLY: 400kV, 3150A, 63 kA, SF6 GIS BUS REACTOR FEEDER BAY MODULE (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) AS PER TS |
| 9 | GIS SUPPLY: 400KV, ONLINE PD MONITORING SYSTEM (OPMS) FOR 400KV GIS SYSTEM |
| 10 | GIS SUPPLY: 400KV, CONTROLLED SWITCHING DEVICE (CSD) FOR 420KV, 3- PH CIRCUIT BREAKER |
| 11 | SUPPLY- GIS : 400KV, 3150A, 1 PHASE GAS INSULATED BUS DUCT (INCLUDING SF6 GAS, STRUCTURE WITH HARDWARES AND EARTHING MATERIALS) |
| 12 | GIS SUPPLY: 400KV,3150A, 1 PHASE SF6 TO AIR BUSHING (POLYMER) (INCLUDING SF6 GAS, STRUCTURE WITH HARDWARES AND EARTHING MATERIALS) |
| 13 | GIS SUPPLY: 390KV,20kA, CLASS-4, 1 PHASESURGE ARRESTER WITH SURGE COUNTER (INCLUDING SF6 GAS, STRUCTURE, HARDWARES & EARTHING MATERIALS) |
| 14 | GIS SUPPLY: LOCAL CONTROL CUBICLES |
| 15 | GIS SUPPLY: SF6 GAS FILLING AND EVACUATING EQUIPMENT (PORTABLE) |
| 16 | GIS SUPPLY: SF6 GAS FILTERING, DRYING, STORAGE AND RECYCLING PLANT |
| 17 | GIS SUPPLY: SF6 GAS LEAK DETECTOR |
| 18 | GIS SUPPLY: OPERATIONAL ANALYSER WITH DCRM KIT- |
| 19 | GIS SUPPLY: SELF-POWERED HYDRAULIC AERIAL WORKING PLATFORM WITH ARTICULATED AND FLY BOOM FOR GENERAL PURPOSE MAINTENANCE IN SWITCHYARD AND TRANSFORMER YARD. (SUITABLE FOR 24M WORKING HEIGHT) |
| 20 | GIS SUPPLY: DEW POINT METER |
| 21 | GIS SUPPLY: PORTABLE PD MONITORING SYSTEM FOR GAS INSULATED SWITCHGEAR |
| 22 | GIS SUPPLY: SF6 GAS ANALYZING EQUIPMENT AND INSTRUMENT |
| 23 | GIS SUPPLY: PORTABLE LEAKAGE CURRENT ANALYZER (FOR GAPLESS SURGE ARRESTER) |
| 24 | GIS SUPPLY: HYDRAULIC PORTABLE TYPE LADDER |
| 25 | GIS SPARES: 400kV GIS- SF6 Gas Pressure Relief Devices of each typealong with O-Rings |
| 26 | GIS SPARES: 400kV GIS- SF6 Pressure gauge with coupling device cumswitch or density monitors and pressure gauge, as applicable (of each type) |
| 27 | GIS SPARES: 400kV GIS- Coupling device of each type for pressure gauge cum switch for connecting Gas handling plant |
| 28 | GIS SPARES: 400kV GIS- Rubber gaskets,“O”Rings and seals for SF6gas, including Circuit Breaker, Disconnector and other GIS equipment |
| 29 | GIS SPARES: 400kV GIS- Molecular filter for SF6 gas with filter bags |
| 30 | GIS SPARES: 400kV GIS- All type of control valves for SF6 gas of each type |
| 31 | GIS SPARES: 400kV GIS- SF6 gas cylinder of 50Kgs/ cylinder |
| 32 | GIS SPARES: 400kV GIS- Locking device to keep the Dis-connectors and Earthing switches in close or open position in case of removal of the driving mechanism (If applicable) |
| 33 | GIS SPARES: 400kV GIS- Spares for Local control cabinet including MCB, fuses, timers, Aux Relays, contactors, push buttons, switches, lamps, annunciationwindows etc of each type & rating, terminals of each type (Set) |
| 34 | GIS SPARES: 400kV GIS- UHF PD sensors of each type, if applicable |
| 35 | GIS SPARES: 400kV GIS- Bus Support insulator / gas Barrier of each type along with associated contacts and shields |
| 36 | GIS SPARES: 400kV GIS- SF6 to air bushing of each type & rating along with conductor and enclosure for 1 phase enclosure |
| 37 | GIS SPARES: 400kV GIS- All types of Corona shield |
| 38 | GIS SPARES: 400kV GIS Circuit Breaker- One complete pole (1phase unit ) of circuitbreaker including CSD/Closing resistor, grading capacitor(as applicable), of each type & rating complete with , interrupter, main circuit , enclosure and marshalling Box with operating Mechanism to enable replacement of any type / rating of CB by spare |
| 39 | GIS SPARES: 400kV GIS Circuit Breaker- Tripping coils assembly with resistors as applicable |
| 40 | GIS SPARES: 400kV GIS Circuit Breaker- closing coil assembly with resistor asapplicable (3nos of each type) |
| 41 | GIS SPARES: 400kV GIS Circuit Breaker- Relays, Power contactors, push buttons, timers & MCBs etc of each type & rating( If applicable) |
| 42 | GIS SPARES: 400kV GIS Circuit Breaker- Aux. switch assembly |
| 43 | GIS SPARES: 400kV GIS Circuit Breaker- Operation counter |
| 44 | GIS SPARES: 400kV GIS Circuit Breaker- Window scope/ Observing window, if applicable |
| 45 | GIS SPARES: 400kV GIS Circuit Breaker-Spare of Hydraulic operated mechanismif Applicable:a. Hydraulic operating mechanism with drive Motor of each type- 1 no.b. Ferrules and joints & couplings of each type- 1 Setc. Hydraulic Filter of each type- 1 Setsd. High Pressure Hose of each type- 1 Sete. N2 accumulator of each type- 2 No.f. Pressure Transducers- 1No.g. Valves of each type- 1 Seth. Orings, gaskets and seals- 1 Seti. Pressure gauges with coupling device of each type- 1 Setj. Hydraulic oil- 20% of total used quantity in substationk. Limit switch- 1 no. of each typel. Pipe length (Copper & steel) of each size & type-1setm. Pressure switch of each type-2nosn. Pressure Relief device of each type- 1set |
| 46 | GIS SPARES: 400kV GIS Circuit Breaker- Complete Spring operating Mechanismincluding charging mechanism etc of each type & rating if applicable |
| 47 | GIS SPARES: 400kV GIS Circuit Breaker- Spring charging motor of each type & rating |
| 48 | GIS SPARES: 400kV GIS Disconnector- Complete set of 3 nos. of single phase/ one 3- ph isolator of each type, dimension, current & voltage rating including main circuit, enclosure, driving mechanism and support insulator etc. to enable replacement of any type/ rating of isolator by spare |
| 49 | GIS SPARES: 400kV GIS Disconnector- Complete set of 3 nos. of single phase/ one3-ph Maintenance earthing switch of each type, dimension, current & voltage rating including main circuit , enclosure , driving mechanism and support insulator etc to enable replacement of any type / rating of isolator by spare |
| 50 | GIS SPARES: 400kV GIS Disconnector- Complete set of 3 nos. of single phase / one 3-ph Fast earthing switch of each type, dimension, current & voltage rating including main circuit, enclosure, driving mechanism and support insulator etc. to enable replacement of any type / rating of isolator by spare |
| 51 | GIS SPARES: 400kV GIS Disconnector- Copper Contact fingers for isolator male & female contact along with corona shield -for one complete (3 phase) isolator of each type and rating |
| 52 | GIS SPARES: 400kV GIS Disconnector- Copper Contact fingers for Maintenanceearthing switch male & female contact along with corona shield -for one complete (3 phase) isolator of each type and rating |
| 53 | GIS SPARES: 400kV GIS Disconnector- Copper Contact fingers for Fast earthingswitch male & female contact along with corona shield -for one complete ( 3phase)isolator of each type and rating, If Applicable |
| 54 | GIS SPARES: 400kV GIS Disconnector- Open/ close contactor assembly, timers, keyinterlock, interlocking coils, relays , push buttons indicating lamps , power contactors, resistors, fuses MCBs & drive control cards etc for one complete MOM box ( 3-ph gang operated or 1-ph unit ) disconnector and ( 3 ph) earthing switch of each type and rating for one complete (3 ph) disconnector and earthing switch of each type & rating, if applicablea) For Disconnector- 1SETb) For Maintenance Earth switch- 1SETc) For Fast Earthing switch- 1SET |
| 55 | GIS SPARES: 400kV GIS Disconnector- Limit switches and Aux. switches for complete3-phase equipment,a) For Disconnector- 1SETb) For earth switch- 1 SETc) For high-speed earth switch- 1SET |
| 56 | GIS SPARES: 400kV GIS Disconnector- Drive Mechanism of each type, a) For isolator- 1SETb) For Maintenance Earth switch- 1SETc) For Fast Earthing switch- 1SET |
| 57 | GIS SPARES: 400kV GIS Disconnector- Motor Drive Mechanism of each type,a) For isolator- 1SETb) For Maintenance Earth switch- 1SETc) For Fast Earthing switch- 1SET |
| 58 | GIS SPARES: 400kV GIS Current Transformer- Complete CT, of each type and withenclosure to enable replacement of any type/ rating of CT as spare |
| 59 | GIS SPARES: 400kV GIS Voltage Transformer- Complete VT of each type and with enclosure to enable replacement of any type / rating of VT as spare |
| 60 | GIS SPARES: 400kV GIS Surge Arrestor- Complete Surge Arrestors of each type andwith enclosure with surge monitor counter to enable replacement of any type/ rating of VT as spare |
| 61 | GIS SPARES: 400kV GIS Surge Arrestor- Surge Monitor and counter of each type/ rating |
| 62 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, OPERATING MECHANISM FOR CIRCUIT BREAKER COMPLETE IN ALL RESPECT |
| 63 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, OPERATING MECHANISM FOR DISCONNECTOR |
| 64 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, OPERATING MECHANISM FOR MAINTENANCE EARTHING SWITCH COMPLETE IN ALL RESPECT |
| 65 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, OPERATING MECHANISM FOR FAST ACTING/ HIGH SPEED GROUNDING SWITCH COMPLETE IN ALL RESPECT |
| 66 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, MAINTENANCE EARTHING SWITCH WITH ENCLOSURE COMPLETE IN ALL RESPECT |
| 67 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, FAST ACTING/ HIGH SPEED GROUNDING SWITCH WITH ENCLOSURE COMPLETE IN ALL RESPECT |
| 68 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, CURRENT TRANSFORMER (2 CORE) WITH ENCLOSURE COMPLETE IN ALL RESPECT |
| 69 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, CURRENT TRANSFORMER (3 CORE) WITH ENCLOSURE COMPLETE IN ALL RESPECT |
| 70 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, CURRENT TRANSFORMER (5 CORE) WITH ENCLOSURE COMPLETE IN ALL RESPECT |
| 71 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS:400KV, SINGLE PHASE BUS BAR |
| 72 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, GIS METALLIC ENCLOSURE |
| 73 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, EXPANSION JOINTS |
| 74 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, FLEXIBLE CONNECTIONS |
| 75 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, BARRIER INSULATOR |
| 76 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, NON-BARRIER INSULATOR |
| 77 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, GAS SEALS |
| 78 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, GAS DENSITY MONITOR SWITCH |
| 79 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, GAS PRESSURE SWITCH |
| 80 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, TEE BEND |
| 81 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, ANGLE BEND |
| 82 | SPARES- GIS: REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS: 400KV, L-BEND |
| 83 | SERVICES- 400kV GIS: SUPERVISION OF ERECTION OF GIS |
| 84 | SERVICES- 400kV GIS:SUPERVISION OF ERECTION OF 1- PHASE GAS INSULATED BUS DUCT |
| 85 | SERVICES- 400kV GIS:SUPERVISION OF ERECTION OF 1 PHASE SF6 TO AIR BUSHING |
| 86 | SERVICES- 400kV GIS:SUPERVISION OF ERECTION OF 1 PHASE SURGE ARRESTER WITH SURGE COUNTER |
| 87 | SERVICES- 400kV GIS:TESTING & COMMISSIONING OF GIS |
| 88 | SERVICES- 400kV GIS : TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT |
| 89 | SERVICES- 400kV GIS : FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR |
| 90 | SERVICES- 400kV GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM |
| 91 | SERVICES- 400kV GIS : TRAINING FOR GIS AT MANUFACTURER WORKS (MIN. 8 NO. CUSTOMER/ BHEL OFFICIAL) |
| 92 | SERVICES- 400kV GIS : TRAINING FOR GIS AT SITE (MIN. 6 NO. CUSTOMER/ BHEL OFFICIAL) |
| 93 | SERVICES- 400kV GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES : SERVICES FOR SUPERVISION OF ERECTION OF GIS |
| 94 | SERVICES- 400kV GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES : SERVICES FOR TESTING & COMMISSIONING OF GIS |
| 95 | SERVICES- 400kV GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES : DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM |
| 96 | SERVICES- 400kV GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES : DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GISTESTING & COMMISSIONING TEAM |
| 97 | SERVICES- 400kV GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES : DEMOBILIZATION & REMOBILIZATION CHARGES OFHV TEST KIT ALONG WITH OPERATOR |