}

Tender For Tourism Development And Beautification Work Of Durga Mandir Campus At Baitalpur, Rudrapur District Deoria, 1 Yatri Hall (Civil) 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm I, deoria-Uttar Pradesh

Government Departments has published Tender For Tourism Development And Beautification Work Of Durga Mandir Campus At Baitalpur, Rudrapur District Deoria, 1 Yatri Hall (Civil) 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm I. Submission Date for this Tender is 29-06-2024. Drainage Tenders in deoria Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43844629
Tender For Tourism Development And Beautification Work Of Durga Mandir Campus At Baitalpur, Rudrapur District Deoria, 1 Yatri Hall (Civil) 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm I
Open Tender
Indian
Uttar Pradesh
Deoria
29-06-2024

Tender Details

Tender For Tourism Development And Beautification Work Of Durga Mandir Campus At Baitalpur, Rudrapur District Deoria, 1 YATRI HALL (Civil) 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil 3 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 4 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 5 Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. 6 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete 7 (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 8 (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 10 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 12 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 13 M 150brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc reqiored for proper completion of the work. 14 Same as in item no. 11 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 15 Providing & laying brick Coba 12mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of 16 coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick 17 ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. 18 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.M 20 F.E. 500 19 Ground Floor 20 15 mm cement plaster 1:4 (1 cement: 4 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brickwall. 21 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 22 Ground Floor 23 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand 24 Ground Floor 25 Ceiling Plaster 26 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). 27 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the approved make & colours) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 28 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm) 29 Distempering(Two coat) withoil bounddistemper of approvedbrand andmanufacture&ofrequired shadeon undecorated wall surface to give an evenshade over &includingapriming coat with cement primer of approvedbrand&manufacture such as Berger,J&N, ShalimarAsian paintsafterthoroughly brushingthe surface free from mortar droppings &other foreign matters& alsoincludingpreparing the surfaceeven with plasterof paris or approvedsynthetic material &sand papered smooth including cost ofallmaterials. 30 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacture, over the plasterd wall surface to prepare the surface even and smooth complete. 31 Construction of drain along with apron. 32 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cementslurry admixed with pigment of matching shade including rubbing, curing and polishing etc. allcomplete as specified and asdirected by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent. Area of slab over 0.50 sqm 33 Stone jali Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 34 Centering and shuttering including strutting, propping etc. and removal of form for : 35 (a) Foundations, footings, bases of columns, etc. for mass concrete 36 (b) Suspended floors, roofs, landings, balconies and access platform 37 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 38 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 39 ELECTRICAL WORK 40 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 41 Group C 42 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 43 Submains : 44 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 45 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 46 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 47 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 48 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 49 20 mm 50 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 51 5/6 A switch 52 3 pin 5/6 A socket outlet 53 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 54 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 55 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 56 1 or 2 Module (75mmX75mm) 57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 58 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 59 MCBs & DB’s : 60 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 61 4 way (4 + 12), Double door 62 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 63 4 way (4 + 12), Double door 64 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 65 Single pole 66 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 67 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 68 100 A,30KA,FPMCCB 69 Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A 70 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 71 ELCB/RCCB Switches : 72 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 73 40 A 74 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 75 Earthing Work : 76 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 77 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 78 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 79 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 80 100 mm width X 50 mm depth X 1.6 mm thickness 81 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 82 Lighting Fixtures (Lights/Fans) : 83 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 84 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 85 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 86 Armoured Cables (Cable/Gland/Lug) : 87 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 88 size 25 sq mm x 3-1/2core 89 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 90 size 25 sq mm x 3-1/2core 91 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 92 size 25 sq mm 93 Miscellaneous Items : 94 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 95 Supply of factory made 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 96 PLUMBING WORK 97 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 98 a) 110mm diameter 99 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 100 a) 110mm 101 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 102 Toilet Block 103 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 104 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 105 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 106 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 107 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor 108 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 109 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 110 Lintel 111 G.F. 112 Slab (Using 1:1.5:3 Mix concrete). 113 G.F. 114 Beams (Using 1:1.5:3 Mix concrete). 115 G.F. 116 Column (Using 1:1.5:3 Mix concrete). 117 G.F. 118 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : 119 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 120 Foundation (Using 1:1.5:3 Mix concrete). 121 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 122 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 123 Painting on D.P.C with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 Kg/Sq. M. approx including cost of fuel if any. 124 M-150 Brick work in super-structure above plinth level up to floor fifth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) 125 Same as in item no. 16 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 126 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 127 (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 128 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: 129 (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 130 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 131 Hold fast for chaukhats of doors/windows. 132 Door / windows & Staircase grill. 133 Angle iron chaukhats size 40x40x5 134 Z Section steel window 135 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 136 Fixing of Door, windows/ventilators chaukhats in position. 137 (a) Door 138 (b) Windows 139 (c) Ventilator chaukhats 140 S/F 141 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 142 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 143 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 144 Size of Tile 600x600 mm 145 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 146 Size of Tile 600x600 mm 147 P/L 25mm thick kota stone flooring over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete. 148 P/L Kota stone slab 25 mm thick in riser of steps,skirting,dado & pillers laid on 10 mm thick mortar 1:3 (1 cement : 3 coarse sand), jointed with grey cement slurry mixed with pigment to match the shade of slabs including rubbing and polishing complete. 149 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 150 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 151 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 152 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(For Internal wall surface) 153 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 154 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 155 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 156 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 157 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 158 (a)250 mm x 10mm 159 (a) 200 mm x 10mm 160 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 161 Making drain along with the apron. 162 P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. 163 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 164 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 165 Providing and fixing art work of Window arch required size and shape Elevational work& other oramental workincluded in over all rates complete in all respect. 166 Centering and shuttering including strutting, propping etc. and removal of form for : 167 (a) Suspended floors, roofs, landings, balconies and access platform 168 (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 169 (c) Foundations, footings, bases of columns, etc. for mass concrete 170 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 171 ELECTRICAL WORK 172 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Light Point) 173 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Fan Point) 174 Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. 175 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Plug and conduit) 176 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. 177 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 178 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 179 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door 180 Supply and fixing of single pole MCB blanking plate 181 CAT A 182 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 183 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 184 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.. 185 CABLES 186 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 187 50 sqmm 3.5 core 188 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 189 50 sqmm 3.5 core 190 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 191 100 mm Dia 192 water supply & plumbingWORK 193 Providing & fixing white vitereous china water closet squatting pan ISI marked (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10/12.5 litrsPVC low level flushing cistern with fittings & brackets 40mm dia C.P. flush pipe with fitting & clamps, 20mm over flow pipe with specials and mosquito proof coupling of approved municipal design, painting wherever required including cutting & making good the walls & floors where required. 194 Orissa Pattern W.C. pan of size580x 440mwith integral type foot rests flush pipe and over flow arrangement. 195 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 196 W.C. pan with ISI marked black solid plastic seat and lid 197 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mmbrass pillar taps, brass chain with rubber plug, 32mmbrass waste of standard pattern including cutting & making good the walls wherever required. 198 a)White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps 199 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wallsand floors wherever required : 200 Range of two half stall urinals with 5 litre P.V.C.automatic flushing cistern 201 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 202 32 mm dia (for wash basin) 203 40 mm dia(for sink and urinal) 204 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 205 Providing & fixing PTMT towelrail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screw 450mm. Long with total length of 495mm, width 78mm and effective height of 88mm 206 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 207 Providing and fixing unplasticised PVC connection pipe with brass unions 208 45 cm length 209 15 mm nominal bore 210 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 211 a) 15 mm nominal bore 212 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 213 a) 15 mm nominal bore 214 PVC PIPES & FITTINGS AND RAN WATER PIPES 215 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 216 110 mm 217 75 mm dia 218 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 219 110 mm 220 75 mm dia 221 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. 222 Coupler 223 110 mm 224 Bend 87.5° 225 110 mm bend 226 75 mm bend 227 Shoe plain 228 110 mm bend 229 75 mm bend 230 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 231 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 232 INTERNAL & EXTERNAL WATER SUPPLY WORKS 233 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 234 20 mm dia nominal outer dia 235 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. 236 Exposed on wall.(internal work) 237 15mm dia nominal bore 238 20mm dia nominal bore 239 25mm dia nominal bore 240 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality. 241 15mm dia nominal bore. 242 20mm dia nominal bore. 243 25mm dia nominal bore. 244 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (Newwork) : 245 15mm dia nominal bore. 246 20mm dia nominal bore. 247 25mm dia nominal bore. 248 Providing and fixing gun metal gate valve with wheel of approved quality. 249 25mm dia nominal bore 250 Providing and fixing brass stop cock of approved quality : 251 20 mm nominal bore 252 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 253 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. 254 a) Pipes 80mm to 300mm diameter. 255 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 256 a) 150mm diameter 257 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 258 a) 150mm diameter 259 P & fixing square mouth S.W. Gully trap grade A comp. with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 & water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg & frame to be not less than 2.70 Kg as per standard design. 260 a) 150 x 100 mm. size P type 261 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 262 nside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets : 263 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 264 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 265 With 20x20 mm square bar 266 SOAK PIT & SEPTIK TANK 267 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 268 In all kind of soil upto 1.5m depth 269 In all kind of soil upto 1.5m to 3.0m. depth 270 In all kind of soil upto 3.0m to 4.5m. depth 271 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 272 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 273 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 274 TMT Fe-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 275 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 276 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 277 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 278 Providing & fixing 75mm dia vent pipes. 279 Providing & fixing of 75mm dia cast iron terminal guard. 280 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 281 M.D. -10- Circular shape 500mm internal diameter 282 M.D. -2.5- Circular shape 450mm internal diameter 283 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 284 Interlocking in Campus (574 SQM) 285 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 286 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 287 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 288 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath,parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size rn, finishing and sweeping extra sand. complete all as per direction of Engineer-in Charge 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 289 BENCHES (Details as per TS Estimate) 290 MURAL WORKONWALL (Details as per TS Estimate) 291 SOLAR LIGHT (UPNEDA) (Details as per TS Estimate) 292 Sinage 293 Information Sign Boards- (1500x1500)-Stone 294 Providing and fixing machine cut, mirror / eggshell polished , Marble stone work with Engraving letters in hard stone on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 oarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. a. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. 295 Engraving letters in hard stone 296 Retro Reflectorised sign (Stainless steel frame and post with both side sign) 297 Direction and place Indification sign with size more then 0.9sqm size board 298 Providing and Eracting direction and place indification retro refectorisedsign as per IRC-67 made of high intensity grade sheeting .the retro reflective sheeting type-IV shall be tested for 3-year outdoor wheathering test in indian condition as per IRC-67:2012 and proof of thesame in form of Govt. report shall be uploded while quoting tender.while clause 801.3 fixed over aluminuam sheeting 2 mm thick with area excedding 0.9 sqm.supoorted on mild steel single angle irion post 75x75x6 mm 2 nos firmly fixed with to the ground by means of properly designed foundation with M-15 Grade cement concrete 45x45x60 cm below ground as per approved drawing complete. (Morth-801 8.6-Base) 299 Bollard single side 300 suplly and fixing of Bollard single side out of 2 mm thick aluminuam sheet welded poly shaped to make it monolithic pillar size 1200 mm high bollard is having frame 900x900 mm and 600 mm dia for fixation made out 35x35x5 mm angle irion and from side is fully cover (size of founsdation 0.45x0.40x0.600mm) 301 GST Extra As per Applicable

Key Value

Document Fees
INR 11800 /-
EMD
INR 110000.0 /-
Tender Value
INR 55 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail