Tender For Under The Chief Minister Tourism Development Partnership Scheme, Tourism Development Work Of Lahar Ki Devi Temple Located In The Development Block Of Jhansi District., Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 15 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 0.00 to 1.50 Mtr. Supplying and stacking of good earth at site. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level: 1:4:8) (1 Cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Treatment of soil under existing floors using chemical emulsion one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 2 (1 cement: 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.53 (1 cement 1.5 coarse sand (zone-III) derived from naturalsources 3 graded stone aggregate 20 mm nominal size derived from natural sources) Upto plinth level (i) RC.C. work in Footing (in) R.C.C. work in Columns (ii) R.CC work in Beam Above plinth to floor-V Ivl Providing and laying in position specified grade of reinforced cementconcrete, escluding the cost of centering, shuttering, finishing andreinforcement 1:1.53 (1 cement: 1.5 coarse sand (zone-III) derived from naturalsources 3 graded stone aggregate 20 mm nominal size derived from natural sources) (iii) R.C.C. work in Columns (3) R.C.C. work in Lintel (ii) R.CC work in Beam (iv) R.C.C. work in Slab Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement: 6 coarse sand) Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources 4 graded stone aggregate 12.5mm nominal size derived from natural sources) Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. Brick Work with common burnt clay (non modular) bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement: 6 coarse sand) Ground Floor Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 ( 1 cement : 4 coarse sand) (a) Ground Floor Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe500D or more. (a) Ground Floor 15 mm plinth plaster (1 cement 4 coarse sand) 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1) cement: 6 coarse sand) Ground Floor 15 mm cement plaster on the rough side of single or half brick wall of mix 16 (1 cement 6 coarse sand) Ground Floor Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) Making plinth protection 50mm thick of cement concrete 1:306 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red (a) Ground Floor Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1) cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab colour black, Cherry/Ruby red Ground Floor Providing edge moulding to 18 mm thick marble stone counters, Vanities etc, including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge Granite work Supply and fixing 6 mm China white glazed tiles in fooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc required for proper completion of the work. (Size of tiles upto 300x300mm). Ground Floor Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement: 25 mm thick Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 13 (1 cement: 3 coarse sand) and jointed with grey cement slurry mised with pigment to match the shade of the slabs, including rubbing and polishing complete Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of ulVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (55 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge (Single/ double glass panes and silicon sealant shall be paid separately) Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm) Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness. frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: Two coals Internal wall surface) Ground Floor Finishing walls (Two cuats) with exterior paint (Apex) of approved brand and manufacture and of required shade on undercoated wall surface to give even shade #1.25 ltr./10 sqm including one coat of primer applied 60.75 ltr./10sqm curing, cost of all materials, labours. T & P etc. required for proper completion of the work. Ground Floor Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: Two coats Ceiling surface) Ground Floor Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Ground Floor Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. Providing and fixing aluminium sliding door bolts. ISI marked anodised (anodic coating not less than grade AC 10 as per 15: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. (a) 250mm x 16mm. Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per 15: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 300 x 10mm 200 x 10mm Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (a) 125 mm. Providing & laying brick Coba 12mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of coba && top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in-charge. Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Ordinary cement without any pigment Stone work plain ashlar in arches in super structure upto floor V level in cement mortar 1:3 (1 cement 3 coarse sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement 2 stone dust) with an admixture of pigment matching the stone shade Both face dressed. Red sand stone Centering and shuttering including strutting, propping etc. and removal of form for all heights: Foundations, footings, bases of columns, etc. for mass concrete Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12 mm thick Columns, Pillars, Piers, Abutments, Posts and Struts Edges of slabs and breaks in floors and walls Under 20 cm wide. Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mmnominal thickness and of approved size and as per approved patternon steel frame work complete ELECTRIFICATION WORKS Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc, as required... Group A Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 2 X 4 sq. mm +1 X 4 sq. mm earth wire Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A Switch 2 way 5/6 A switch 15/16 A Switch 3 pin 5/6 A Socket outlet Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) 3 Module 100mmX75mm) 4 Module 125mmX75mm) 6 Module 200mmX75mm) 8 Module 125mmX125mm) 12 Module 200mmX150mm) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch bes including connections but excluding modular plate etc. as required. Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRIS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc, as required. Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mmsweep Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door Supplying and fixing 5 A to 32 A rating, 240/415 V. 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Earthing with G.1. earth pipe 45 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe et Earthing with G.1. earth plate 600 mm X 600 mm X 16 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as Supplying and laying 25 mm X 5 mm G.1 strip at 10.50 metre below ground as strip earth electrode, including connection/ terminating with GL nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & Petc, for proper completion of work Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete, excluding tube on surface complete in all respect 1 X 22 W PLUMBING WORKS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Providing and fixing white vitreous china pedestal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. Providing and fixing wash basin with CI. brackets. 15 mm C.P. brass pillar taps, 32 mm CP. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 630x 450 mm with a pair of 15 mm CP. brass pillar tap. Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Providing and fixing white vitreous china flat back half stall urinal of size 58638h350 mm with white PVC automatic flushing cistern, with fittings. standard size C.P. brass flush pipe, spreaders with unions and clamps (all in CP. brass) with waste fitting as per IS 2556, CI. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C automatic flushing cistern Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-incharge and finished smooth. Granite Stone of approved shade Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. Providing and fixing ITMT Liquid soap container 109 mm wide 125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to 15 5382 leaving 10 mm gap for thermal expansion (1) Single socketed pipes a) 110mm diameter Supply and fixing of UPVC SW.R. pipe type-B confirming to 15-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to 15-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fittlings such as elbow,bend.tee and y-tee including supply of al marerial labour and TP Required for proper completion of work 110 mm O.D. Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jail Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 110 mm Supply and fixing of UPVC SW.R. plain tee confirming to 15-14735. Size 110x110x110 mm Supply and fixing of UPVC S.W.R. plain Y confirming to 15-14735. Size 110 mm Laying cement concrete 1:5:10 in haunching P.V.C./S.W. Pipes including conccrete for bedding necessary form work and curing complete.around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring/ ground) 110 mm diameter Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1) cement 3 coarse sand) and a coat of neat cement, punning rounding the edges and making and finishing the outlet complete a) 110mm Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 14 (1 cement: 4 coarse sand) and making good the wall etc. complete. a) 110mm Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20mm dia nominal outer dia pipes 25mm dia nominal outer dia pipes 32mm dia nominal outer dia pipes Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 100m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes 20mm dia nominal outer dia pipes 25mm dia nominal outer dia pipes 32mm dia nominal outer dia pipes Providing & fixing CP brass bib cock of approved quality conforming to 15 8931 15mm nominal bore Providing & fixing C.P. brass long body bib cock of approved quality conforming to 15 standards and weighing not less than 690 gms. 15mm nominal bore Providing and fixing gun metal gate valve with wheel of approved quality(screwed end)... 25mm dia nominal bore Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore Supply and hoisting of Sintex or equivalent high density polyethylene seemless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tnak should be ISI marked, Sintex or equivalent. For 500 litres Providing and fixing gun metal gate valve with wheel of approved quality. (a) 20 mm dia nominal bore Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter Providing, laying and joining PVC/swr pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement 1 fine sand) including testing of joints etc. complete a) 110mm diameter Laying cement concrete 1:2:4 in haunching P.V.C./ SWR Pipes including conccrete for bedding necessary form work and curing complete a) 110mm dia. Providing and fixing 5.W. Gully trap grade A complete with C.I. grating brick masonry chamber and water tight CLcover frame of 300 x 300mm. size (inside) square mouth traps of T or S type traps. a) 100 x 150 mm. dia Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 900x800mm and 500mm deep including Cl cover with frame With FPS bricks of class designation 75 Extra for depth of man hole size 900x800mm Inside size 900x1200 mmm & 1.0 meter deep including C.L. cover with frame Replacement of M.S. foot rests including dismantiling concrete blocks and fixing in manholes with 20x20x10 cm cement concrete blocks 1:36 (1 cement:3 coarse sand graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar SEPTIC TANK WITH SOAK PIT SEPTIC TANK WITH SOAK ITT LANDSCAPING WORK Supplying and stacking sludge at site including royalty and carriage up to 5 km (sludge measured in stacks will be reduced by 8% for payment). Carrigae of sludge upto 5 K.M. Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment): Screened through sieve of LS designation 4.75 mm 2 Carrigae of manure upto 5 K.M. Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-incharge. Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately). Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). Holes 0.9 m dia, and 0.90 m deep. Plantation of trees Supply and stacking of Azadirachta indica (Neem) plant of height 120-130 cm. in big polybag of size 25 cm as per direction of the officer in charge Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big polybag of size 25 cm as per direction of the officer-in-charge Supply and stacking of Ficus religiosa (Peepal) plant of height 150-165 cm. in big polybag of size 30 cm as per direction of the officer-in- charge Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the treeguard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge. COST OF INTERLOCKING Earth work in exacavation in t. in ordinary soil(loan) clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/e with in alead of 50m Providing and laying in cament concrete 1:48 (1 cement 4 coarse sand 18 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. Class M-150 brick work in 14 cement coarse sand (of) 2.5 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work Interlocking Tiles-Rubber moulded reflective Zig-Zag Shum Providing and laying of Interlocking Concrete Block Laying of Pavements having thickness 80mm including levelling and dressing of surface to required level and slope, spreading and moisting 30m thick local sand on bend, filling joints with local sand on bend, filling joints with local sand etc for proper completion of the work as per drawing and technical specification clause 1504 COST OF STONE SITTING BENCH COST OF SOLAR LIGHT COST OF RED SAND STONE DUSTBIN & BUCKET COST OF SIGNAGE