}

Tender For Tourism Development And Beautification Works Of Shiv Mandir At Village-Maharajganj Tola-Jamunara Block-Chargawan Distt-Gorakhpur, 1 Yatri Hall (Civil 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Fou, gorakhpur-Uttar Pradesh

Government Departments has published Tender For Tourism Development And Beautification Works Of Shiv Mandir At Village-Maharajganj Tola-Jamunara Block-Chargawan Distt-Gorakhpur, 1 Yatri Hall (Civil 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Fou. Submission Date for this Tender is 28-06-2024. Paver Blocking Tenders in gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43795771
Tender For Tourism Development And Beautification Works Of Shiv Mandir At Village-Maharajganj Tola-Jamunara Block-Chargawan Distt-Gorakhpur, 1 Yatri Hall (Civil 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Fou
Open Tender
Indian
Uttar Pradesh
Gorakhpur
28-06-2024

Tender Details

Tender For Tourism Development And Beautification Works Of Shiv Mandir At Village-Maharajganj Tola-Jamunara Block-Chargawan Distt-Gorakhpur, 1 Yatri Hall (Civil 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 3 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 4 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 5 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. 6 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete 7 Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 8 (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 9 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 10 As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) 11 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) 12 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 13 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 14 First class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc reqiored for proper completion of the work. 15 Painting with two coats of air blown bitumen 85/50 or 85/25 @ 1.7kg/sqm approxincluding cost of fuel if any. 16 Same as in item no. 12 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. 17 G.F. 18 F.F. 19 Same as in item no. 13 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 20 G.F. 21 F.F. 22 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for completion ofwork and including supply of steel its wastage bend hooks & authorised over lapping shall be measured upto floor two level. 23 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 24 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 25 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand 26 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 27 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 28 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 29 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, moulding & polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade (Area of slab over 0.50 sqm) 30 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, moulding & polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade (Area of slab upto 0.50 sqm) 31 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 32 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 33 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). 34 Providing & fixing ISI marked flush door shutters conforming to IS: 2202 (Part-I) non-decorative type, core of block board construction with frame of Ist class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 (a) 35mm thick 36 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 37 Providing & fixing of hold fast for chaukhatsof doors and windows. 38 Providing & fixing of door / windows grill. 39 Z-Section steel windows 40 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 41 Fixing of Door, windows/ventilators chaukhats in position. 42 (a) Door chaukhats 43 (b) Window chaukhats 44 Ventilator Chaukhat 45 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth. 46 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 47 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth including cost of material, labour, T & P etc. complete. 48 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 49 Providing & fixing Aluminium sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm 50 Providing and fixing Aluminium towerbolts with necessary screws etc. complete 51 (a) 250 mm x 10mm 52 (a) 200 mm x 10mm 53 Providing and fixing Aluminium handles with screws etc. complete (a) 125 mm 54 Providing and laying brick coba 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. 55 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust & other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of work. 56 Same as item above but on new wood surface. 57 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts, bolts complete, i/c fixing the railing with necessary accessories & stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. 58 Fixing panes of glass with atul or equivalent I.S.I. marked quality putty, brads and springs complete. (a) 4 mm thick. 59 Making of drain along with apron. 60 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading. 61 Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. With decorative veneering on one side and commercial veneering on other side 62 Centering and shuttering including strutting, propping etc. and removal of form for : 63 (a) Foundations, footings, bases of columns, etc. for mass concrete 64 (b) Suspended floors, roofs, landings, balconies and access platform 65 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 66 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 67 Plumbing Works 68 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 69 W.C. pan with ISI marked white solid plastic seat and lid 70 Providing & fixing toilet paper holder 71 C.P. brass 72 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 73 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 74 White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 75 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 76 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 77 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 78 100 mm diameter 79 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 80 15 mm nominal dia 81 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 82 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 83 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 84 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) 85 15 mm nominal bore 86 Providing and fixing uplasticised PVC connection pipe with brass unions : 87 45 cm length 88 15 mm nominal bore 89 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 90 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 91 15mm nominal bore 92 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 93 15mm nominal bore 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 95 Concealed work, including cutting chases and making good the walls etc. 96 For Internal Toilet 97 15 mm nominal outer dia Pipes 98 20 mm nominal outer dia Pipes 99 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 100 Internal work - Exposed on wall 101 20 mm nominal bore 102 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 103 Terrace loop 104 20 mm nominal bore 105 25 mm nominal bore 106 32 mm nominal bore 107 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 108 20mm diameter pipe 109 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 110 25 to 40 mm nominal bore 111 Providing and fixing brass stop cock of approved quality : 112 For Internal Toilet 113 15 mm nominal bore 114 20 mm nominal bore 115 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 116 For vertical pipe connection with terrace ringmain 117 20 mm nominal bore 118 25mm nominal bore 119 32mm nominal bore 120 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 121 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 122 110 mm dia (for rain water) 123 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 124 Single Push Fit Coupler 125 110 mm dia 126 Single tee with door 127 110x110x110 mm 128 Plain bend 87.5 deg 129 110 mm dia 130 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 131 110 mm dia 132 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 133 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 134 150 x 100mm size P-type 135 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 136 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 137 100 mm diameter 138 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 139 All kind of soil 140 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 141 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 142 100mm dia SWpipe 143 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 144 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 145 TOTAL schedule items 146 Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 147 75 mm O.D. 148 110 mm O.D. 149 Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 150 Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. 151 Size 75 mm 152 Size 110 mm 153 Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. 154 Size 75/90 mm 155 Size 110 mm 156 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. 157 Size 75x75x75 mm 158 Size 110x110x110 mm 159 Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. 160 Size 75 mm 161 Size 110 mm 162 Electrical Works 163 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 164 Group C 165 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 166 Submains : 167 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 168 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 169 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 170 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 171 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 172 20 mm 173 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 174 5/6 A switch 175 3 pin 5/6 A socket outlet 176 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 177 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 178 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 179 1 or 2 Module (75mmX75mm) 180 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 181 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 182 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 183 4 way (4 + 12), Double door 184 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 185 4 way (4 + 12), Double door 186 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 187 Single pole 188 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 189 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 190 100 A,30KA,FPMCCB 191 Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A 192 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 193 ELCB/RCCB Switches : 194 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 195 40 A 196 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 197 Earthing Work : 198 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 199 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 200 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 201 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 202 100 mm width X 50 mm depth X 1.6 mm thickness 203 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 204 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 205 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 206 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 207 Armoured Cables (Cable/Gland/Lug) : 208 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 209 size 25 sq mm x 3-1/2core 210 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 211 size 25 sq mm x 3-1/2core 212 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 213 size 25 sq mm 214 Miscellaneous Items : 215 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 216 Supply of factory made 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 217 L.T. PANELS 218 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. 219 The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. 220 The minimum clearances between bus bars shall be as follows : 221 Phase to phase - minimum 20mm 222 Phase to neutral-minimum 15mm 223 Main LT Panel 224 Incoming : 225 200 Amp. TPN-1 No 226 Outgoing : 227 100 Amp. TPN-2 No 228 Cat. B Cubical Type 229 Common Toilet Civil 230 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 231 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 232 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 233 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 234 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor 235 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 236 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 237 Lintel 238 G.F. 239 Slab (Using 1:1.5:3 Mix concrete). 240 G.F. 241 Beams (Using 1:1.5:3 Mix concrete). 242 G.F. 243 Column (Using 1:1.5:3 Mix concrete). 244 G.F. 245 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : 246 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 247 Foundation (Using 1:1.5:3 Mix concrete). 248 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 249 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 250 Painting on D.P.C with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 Kg/Sq. M. approx including cost of fuel if any. 251 M-150 Brick work in super-structure above plinth level up to floor fifth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) 252 Same as in item no. 16 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 253 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 254 (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 255 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: 256 (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 257 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 258 Hold fast for chaukhats of doors/windows. 259 Door / windows & Staircase grill. 260 Angle iron chaukhats size 40x40x5 261 Z Section steel window 262 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 263 Fixing of Door, windows/ventilators chaukhats in position. 264 (a) Door 265 (b) Windows 266 (c) Ventilator chaukhats 267 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) [Plinth Plaster] 268 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 269 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) 270 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 271 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 272 Size of Tile 600x600 mm 273 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 274 Size of Tile 600x600 mm 275 P/L 25mm thick kota stone flooring over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete. 276 P/L Kota stone slab 25 mm thick in riser of steps,skirting,dado & pillers laid on 10 mm thick mortar 1:3 (1 cement : 3 coarse sand), jointed with grey cement slurry mixed with pigment to match the shade of slabs including rubbing and polishing complete. 277 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 278 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 279 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 280 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(For Internal wall surface) 281 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 282 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 283 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 284 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 285 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 286 (a)250 mm x 10mm 287 (a) 200 mm x 10mm 288 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 289 Making drain along with the apron. 290 P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. 291 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts, bolts complete, i/c fixing the railing with necessary accessories & stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. 292 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 293 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 294 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills andsoffits. 50 mm thick 295 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 296 Providing and fixing art work of Window arch required size and shape Elevational work& other oramental workincluded in over all rates complete in all respect. 297 Centering and shuttering including strutting, propping etc. and removal of form for : 298 (a) Suspended floors, roofs, landings, balconies and access platform 299 (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 300 (c) Foundations, footings, bases of columns, etc. for mass concrete 301 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 302 water supply & plumbingWORK (Details as per TS Estimate 303 ELECTRICAL WORK 304 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Light Point) 305 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Fan Point) 306 Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. 307 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Plug and conduit) 308 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. 309 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 310 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 311 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door 312 Supply and fixing of single pole MCB blanking plate 313 CAT A 314 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 315 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 316 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.. 317 CABLES 318 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 319 50 sqmm 3.5 core 320 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 321 50 sqmm 3.5 core 322 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 323 100 mm Dia 324 water supply & plumbingWORK 325 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 326 In all kind of soil upto 1.5m depth 327 In all kind of soil upto 1.5m to 3.0m. depth 328 In all kind of soil upto 3.0m to 4.5m. depth 329 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 330 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 331 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 332 TMT Fe-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 333 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 334 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 335 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 336 Providing & fixing 75mm dia vent pipes. 337 Providing & fixing of 75mm dia cast iron terminal guard. 338 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 339 M.D. -10- Circular shape 500mm internal diameter 340 M.D. -2.5- Circular shape 450mm internal diameter 341 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 342 DRAIN 300X450 (150 RM) 343 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 344 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 345 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 346 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 coarse sand) 347 25 mm cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregate of size 12.5 mm and below by volume) laid over set and hardened surface of sturctural slab or base concretefinished with a floating coat of neat cement using cement . 348 INTERLOCKING (450 Sqm) 349 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 350 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 351 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 352 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by usingplate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. 353 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 354 Sand Stone Flooring (382.80 sqm) 355 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. 356 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. 357 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 358 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar 359 Red sand stone 360 TONE BENCHES-Supply, and fixing in position 3 seater sand Stone Benches, 1800*600*450 mm at site as per approved quality and design. including all cost of accesories, transportation etc. complete in all respect. 361 TREE CHABUTRA (02 Nos) 362 Earth work in excavation 363 P.C.C. 1:4:8 364 Brick work in 1:4in foundation. 365 12 MM thick plaster (1:3) 366 C.C. flooring 367 GRANIET FLOORING PARIKRAMA MARG (120 Sqm) 368 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 369 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 370 Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 371 GAZIBO 372 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 373 Filling of Carted earth 374 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 375 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 376 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 377 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 378 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 379 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and excluding necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 380 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in beams excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 381 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in footing excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 382 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in columns excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 383 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 384 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 385 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 386 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 387 15 mm cement plaster on rough side of single or half brick wall of mix: 388 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 389 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 390 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Inner walls) 391 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 392 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 393 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing of edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm (Granite Cherry/Ruby red) 394 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 395 Centering and shuttering including strutting, propping etc. and removal of form for : 396 (a) Foundations, footings, bases of columns, etc. for mass concrete 397 (b) Suspended floors, roofs, landings, balconies and access platform 398 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 399 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 400 Making Arches of Sand stone Ornamental stone works between column like lattu, making toran, etc. complete. 401 INTERNAL W/S & SANITATION WORKS 402 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 403 110 mm 404 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 405 110 mm 406 INTERNAL ELECTRIFICATION 407 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 408 Group C 409 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 410 Submains : 411 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 412 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 413 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 414 20 mm 415 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 416 5/6 A switch 417 3 pin 5/6 A socket outlet 418 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 419 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 420 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 421 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 422 MCBs & DB’s : 423 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 424 4 way (4 + 12), Double door 425 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 426 Single pole 427 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 428 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 429 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 430 ELCB/RCCB Switches : 431 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 432 40 A 433 Earthing Work : 434 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 435 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 436 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 437 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 438 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 439 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 440 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 441 Sinage 442 Information Sign Boards- (1500x1500)-Stone 443 Providing and fixing machine cut, mirror / eggshell polished , Marble stone work with Engraving letters in hard stone on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 oarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. a. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. 444 Engraving letters in hard stone 445 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols andborders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge. 446 Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm 447 Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side ofluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment) 448 SOLAR LIGHT (As per U.P.NEDA) (as per TS Estimate) 449 Boaring 450 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level, All types of soil 300 mm dia 451 Supplying, assembling, lowering of 110 mm pvc pipe and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 452 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 453 150 mm nominal size dia 454 Supplying, filling, spreading & leveling coarse sand of size range 1.5n mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. 455 Providing and fixing M.S. clamp 4 dia of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 456 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix Inside size 90x80cms and 45cms deep. 457 Providing and fixing G.I.Pipe complete 40 mm dia 458 Supplying, & fixing of Nylon jali arround the slotted jali 459 Supply of 2 HP submersible pump varuna/KSB/CRI or equivalent make. 460 Supply of single phase strater for pump 461 Supply and fixing of flat cable for pump 2.50 sqm 3 core copper cable 462 100 mm dia PVC end Cap 463 GST Extra As per Applicable

Key Value

Document Fees
INR 17700 /-
EMD
INR 225000.0 /-
Tender Value
INR 1.12 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail