}

Tender For Construction Of District I.P.H.L. In Bhadohi, 1 Construction Of District I.P.H.L. In Bhadohi 2 (Civil Work) 3 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth, 1.5M In W, bhadohi-Uttar Pradesh

Government Departments has published Tender For Construction Of District I.P.H.L. In Bhadohi, 1 Construction Of District I.P.H.L. In Bhadohi 2 (Civil Work) 3 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth, 1.5M In W. Submission Date for this Tender is 26-06-2024. Footwears Tenders in bhadohi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43792628
Tender For Construction Of District I.P.H.L. In Bhadohi, 1 Construction Of District I.P.H.L. In Bhadohi 2 (Civil Work) 3 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth, 1.5M In W
Open Tender
Indian
Uttar Pradesh
Bhadohi
26-06-2024

Tender Details

Tender For Construction Of District I.P.H.L. In Bhadohi, 1 Construction of District I.P.H.L. in Bhadohi 2 (Civil work) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 5 Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 7 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). 8 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 9 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : 10 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 12 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 13 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 14 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 15 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 16 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 17 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 19 Cement mortar 1:6 (1 cement : 6 coarse sand) 20 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). 21 Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 23 Cement mortar 1:6 (1 cement : 6 coarse sand) 24 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 25 Cement mortar 1:4 (1 cement :4 coarse sand) 26 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 27 Thermo-Mechanically Treated bars of grade Fe-500D or more. 28 15 mm cement plaster on rough side of single or half brick wall of mix : 29 1:4 (1 cement: 4 coarse sand) 30 15 mm cement plaster on rough side of single or half brick wall of mix : 31 1:6 (1 cement: 6 coarse sand) 32 12 mm cement plaster of mix : 33 1:6 (1 cement: 6 coarse sand) 34 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections 35 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 36 Size of Tile 600x600 mm 37 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 38 Granite stone slab colour black, Cherry/Ruby red 39 Area of slab over 0.50 sqm 40 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 42 Size of Tile 600x600 mm 43 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth. 44 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 45 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 46 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 47 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimensionin higher side shall be accepted but no extra payment on this account shall be made. 48 Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 meter). 49 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge 50 Extruded section profile size 48x40 mm 51 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : 52 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 53 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 54 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 55 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : 56 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 57 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 58 Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, including preparation of surface but excluding grading complete with : 59 Bitumen felt (hessian base) type 3 grade I conforming to IS : 1322 60 Single rubber stopper 61 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 62 250x16 mm 63 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 64 250x10 mm 65 200x10 mm 66 Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 67 125 mm 68 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 69 4.0 mm thick glass panes. 70 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. 71 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece. 72 Aluminium Partition 73 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 74 Centering and shuttering including strutting, propping etc. and removal of form for : 75 Foundations, footings, bases of columns, etc. for mass concrete 76 Suspended floors, roofs, landings, balconies and access platform 77 Lintels, beams, plinth beams, girders, bressumers and cantilevers 78 Columns, Pillars, Piers, Abutments, Posts and Struts 79 PLUMBING WORKS 80 SUB HEAD - I - (SANITARY FIXTURES & C.P. BRASS FITTING) 81 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required 82 W.C. pan with ISI marked white solid plastic seat and lid 83 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 84 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. 85 White Agaria Marble Stone 86 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 87 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 88 Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required. 89 Kitchen sink with drain board 90 510x1040 mm bowl depth 250mm 91 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 92 Semi rigid pipe 93 40 mm dia 94 Providing and fixing uplasticised PVC connection pipe with brass unions : 95 30 cm length 96 15 mm nominal bore 97 45 cm length 98 15 mm nominal bore 99 Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 100 Providing and fixing toilet paper holder. 101 C.P. brass 102 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 103 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 104 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 105 15 mm nominal bore 106 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms. 15 mm nominal bore 107 15 mm nominal bore 108 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 109 15 mm nominal bore 110 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 111 15 mm nominal bore 112 Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. (Angle valve to be provide under item no. 18 and measure with that item.) 113 SUB HEAD - II - (SOIL, WASTE, RAIN WATER AND VENT PIPES) 114 RAIN WATER DRAINAGE WORK 115 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 116 110 mm 117 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 118 Coupler 119 110 mm 120 Bend 87.5 degree 121 110 mm Bend 122 Shoe (Plain) 123 110 mm Shoe 124 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 125 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 126 Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 127 110mm dia pipe. 128 UPVC SWR SOIL, WASTE & VENT PIPES AND FITTINGS 129 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 130 Internal Toilet (Soil, Waste & Rain Water Pipe) 131 110 mm dia. 132 Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 133 110mm x 110mmX110mm 134 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 135 Bend without door (87.5°) 136 110mm 137 Bend without door (45°) 138 110mm 139 Y Fitting without door 140 110mm 141 Single Tee without door 142 110 mm 143 Coupler 144 110mm 145 Vent Cowl 146 110mm 147 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 148 For Wash basin & Urinal 149 50mm dia. Pipe 150 40mm dia. Pipe (for wash basin & sunken toilet spout) 151 Elbow (90°) 152 50mm 153 40mm 154 Elbow (45°) 155 50mm 156 40mm 157 T fitting 158 50mm 159 40mm 160 Coupler 161 50mm 162 40mm 163 SUB HEAD - III - (WATER SUPPLY) 164 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 165 Concealed work, including cutting chases and making good the walls etc. 166 15 mm dia nominal bore 167 20 mm dia nominal bore 168 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 169 25 mm dia nominal bore 170 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc 171 Internal work - Exposed on wall / Terrace 172 20 mm dia nominal bore 173 25 mm dia nominal bore 174 32 mm dia nominal bore 175 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 176 20 mm dia nominal bore 177 25 mm dia nominal bore 178 32 mm dia nominal bore 179 Providing and fixing gun metal gate valve with wheel of approved quality. 180 20mm dia nominal bore 181 25mm dia nominal bore 182 32mm dia nominal bore 183 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 184 25mm dia nominal bore 185 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 186 Domestic Tank 187 SUB HEAD - IV - (EXTERNAL PERIPHERY WORK) 188 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 189 All kinds of soil 190 Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 191 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 192 150 mm.dia. RCCPipes 193 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 194 150 mm.dia. RCCPipes 195 Providing and fixing square-mouth S.W. gully trap SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 196 150 x 100 mm size P type 197 With common burnt clay FPS (non modular) bricks of class designation 7.5 198 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 199 100 mm diameter 200 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. 201 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 202 With common burnt clay FPS (non modular) bricks of class designation 7.5 203 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 204 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :- (EXTERNAL WATER SUPPLY) 205 All kinds of soil 206 Pipes, cables etc, not exceeding 80 mm dia. 207 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 208 25 mm dia nominal bore 209 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- 210 Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. 211 25 mm dia nominal bore 212 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 213 25 mm dia nominal bore 214 SUB HEAD - V - (FIRE EXTINGUISHERS) 215 Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. 216 4.5kg capacity cylinder. 217 ABC type extinguisher with cylinder fully charged with 6 Kg. capacity. 218 ELECTRIFICATION 219 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 220 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 221 Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. 222 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 223 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire 224 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 225 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire 226 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire 227 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire 228 4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire 229 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 230 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 231 5/6 amps switch 232 15/16 amp switch 233 3 pin 5/6 amp socket outlet 234 6 pin 15/16 amp socket outlet 235 Telephone socket outlet 236 DATA outlet 237 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 238 Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 239 2 Pair 240 20 Pair 241 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 242 2 run of cable 243 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 244 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 245 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 246 (a): Up to 450mm sweep 247 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 248 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 249 25 mm 250 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS 251 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM(tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 252 1200 mm sweep ceiling fan 253 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 254 Supply ofrecess/Surface mounting round 12 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. 255 Supply ofrecess/Surface mounting round 8 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. 256 Supply of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. 257 SUBHEAD III-DISTIBUTION BOARD 258 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 259 4 way Double door (4 + 12) 260 6 way Double door (4 + 18) 261 8 way Double door (4 + 24) 262 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 263 For 4 way, Double door TPN MCBDB 264 For 6 way, Double door TPN MCBDB 265 For 8 way, Double door TPN MCBDB 266 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 267 Single pole 268 Supplying and fixing 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 269 63A 4P 270 40A 4P 271 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 272 SUBHEAD IV-EARTHING 273 Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects. 274 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 275 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 276 SUBHEAD V-CABLES 277 Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. 278 3.5C x 70 sqmm aluminium conductor, A2XWY. 279 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 280 3½ X 70 sq. mm (38mm) 281 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 282 Above 35 sq. mm and upto 95 sq. mm(clamped with 1mm thick saddle) 283 SUBHEAD VI -MISCELLANEOUS 284 Supply, Installation, Testing and Commissioning of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 285 S/f of 30 pair Telephone Tag Block for Floors and building with Krone connectors , with connection and punching of same 286 SUBHEAD VII-MAINL. T. PANELS 287 LT PANEL 288 Design, Supply, installation, testing and commissioning of indoor/outdoor floor mounted/ wall mounted, IP43/IP65, IEC 61439/IS 8623, factory built, modular, sectionalised, compartmentalized, extendable type HT/LT cubicle panel of suitable size suitable for operation on 33/11/0.433/0.415kV, 50 Hz AC 3 phasesupply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears as per SLD ,technical specifications etc.complete in all respect so as to fulfill all as required. 289 LT Panel 290 The minimum clearances between bus bars shall be as follows : 291 Phase to phase - minimum 20mm 292 Phase to neutral-minimum 15mm 293 Incoming : 294 1Nos200 Amp. 4P MCCB of 25kABreaking capacity 295 1Nos200 Amp. 4P ATS 296 Metering : 297 1 Set of CTs one of 250/ 5Amp ratio for Multifunction Meter 298 1 Nos. Set of Phase Indication Lamp. 299 1 Nos. of class-III Type SPD 300 Bus Bar : 301 400 Amp.TPN aluminimum bus bar of suitable length.50KA 302 Outgoing : 303 Phase indication lamps on each outgoing to be provided. 304 05 No.63 Amp 4PMCB. (10 KA) 305 02 No.40 Amp 4PMCB. (10 KA) 306 Panel described as above 307 AIR CONDITIONING 308 Direct Expansion air- conditioner with inverter technology Supply and installation of split direct expansion air conditioners suitable for operation on A/C Supply single phase 50HZ 230 Volts with hermetically sealed compressor with air cooled condenser with DC inverter technology , motor capacitor and start run capacitor , relay and over load protector internal unit , with one indor unit the condenser to avoid noise including standard length of suitable size copper tubing covered with insulation tube . (HIGH WALL CHORDED / CORDLESS ) SUITABLE CAPACITY 3 CORE SHEATHED / PVC COPPER CABLE AND A BATTERY OPERATEDWIRELESS REMOTE VOLTAS / HITACHI / SAMSUNG ETC.(2.0 TR. BEE S STAR EER 3.4) 309 V- Guard DS Ace 5540 Voltage Stablizer for up to 2 ton inverter AC with Colour Changing LED Ring and Digital Display (working Range 120-280 VAC ) (white) application inverter ACs up to 2 ton : CAPACITY 15 A COLOUR White FEATURES intelligent Time Delay System (ITDS) FOR ENSURING PROPER SAFTY NET FOR THE AC COMRESSOR , white ABS Cabinet with wall mounting facilites advanced micro-controller based design for better input voltage correction built- in thermal overload protection for preventing appliance burn out. EMI filter Enabled for suppressing electro magnetic waves and safeguard connected devices . Fail Safe Circuit Design ,Low & High Voltage Cut - Off PLUG AND SOCKET RATING 30 A BLOCK CONNECTOR CORD LENGHT (Outside ) 1.1m 3. Installation & Cartage L.S. 3800/- Rs. 310 Installation & Cartage 311 COST OF FURNITURE 312 COST OF INTERLOCKING 313 G.S.T. Extra as per Applicable

Key Value

Document Fees
INR 11800 /-
EMD
INR 148000.0 /-
Tender Value
INR 73.80 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail