}

Tender For Internal Electrification Of New Constructed Authority Building, Liberary Sec-56 And New Urinals, Toilets In Sec-58,59,60,22, Noida, 1 Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In, noida-Uttar Pradesh

Local Bodies has published Tender For Internal Electrification Of New Constructed Authority Building, Liberary Sec-56 And New Urinals, Toilets In Sec-58,59,60,22, Noida, 1 Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In. Submission Date for this Tender is 02-07-2024. Road Work Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43777400
Tender For Internal Electrification Of New Constructed Authority Building, Liberary Sec-56 And New Urinals, Toilets In Sec-58,59,60,22, Noida, 1 Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In
Open Tender
Indian
Uttar Pradesh
Noida
02-07-2024

Tender Details

Tender For Internal Electrification Of New Constructed Authority Building, Liberary Sec-56 And New Urinals, Toilets In Sec-58,59,60,22, Noida, 1 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. as per direction of E/I UPPWD-2018(Electrical) PS-138 (C ) 2 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm.FRLSH PVCcopper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour washas per direction of E/I UPPWD-2018(Electrical) PS-140(C ) 3 Wiring point for plug with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable as earth wire drawn inside the conduit.partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash as per direction of E/I UPPWD-2018(Electrical) PS-141(C ) 4 Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.complete in all respect as per direction of E/I. UPPWD-2018 PS-1139 5 Supply and wiring of submain with Two number 4.00 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty pvc conduit concealed in wall, complete with one number 2.5 sq. mm. FRLSH PVC insulated multistrand copper onductorcable as earth contuiity wire drawn in conduit. etc Complete in all respect as per direction of E/I UPPWD-2018(Electrical) PS-216 (C ) 6 Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Complete in all respect as per direction of E/I DSR-2018(Electrical) 1.21.1 7 Supply, Installation, Testing & Commissioningof 300 mm dia 900 R.P.M. Exhaust Fan with Louvered shutters. Complete in all respects. AOR 8 S & F surface/Flush mounting 8ways SPN distribution board without additional metal door without MCB complete in all respect, as direct by Engineer in Charge. Complete in respect as directed at site by E/I PS.No. 1024 (CAT-A) UPPWD-2018 9 S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. Complete in all respect as per direction of E/I. PS No-1002, UPPWD-2018 (CAT-A) 10 S&F of 40 Amp D.P. Isolator .Complete in all respect as per direction of E/I. PS No-1005 (CAT-A) UPPWD-2018 11 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver setcomplete in all respect.. Complete in all respect as per direction of E/I. PS No-1402 (AAA) UPPWD-2018 12 Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection Complete in all respect as per direction of E/I. PS No-1417 (AAA) UPPWD-2018 13 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface Complete in all respect as per direction of E/I. PS No-1413 (AAA) UPPWD-2018 14 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Complete in all respect as per direction of E/I. UPPWD-2018 PS - 725B 15 S/L of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects (P.S. No. 716) 16 S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(PS No. 501) UPSR -2018Make -Havells/Polycabe/Plazaa)- 16 sq. mm 4 core 17 b)- 16 sq. mm 2 core 18 S/F of Plain or Pin type copper tin plated cable socket (Lug)to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I (PS No. 504) UPSR-2018a)-16 sq. mm 19 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. E/I. UPPWD-2018 PS No. 1423 Catt-AAA 20 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR-18 (Elect.) Item No-14.16-a)-63 mm dia (OD-63 mm & ID-51 mm nominal) DSR-18 (Elect.) Item No-14.16.1 21 b)-90 mm dia (OD-90 mm & ID-76 mm nominal) DSR-18 (Elect.) Item No-14.16.2 22 Excavation in foundation in ordinary soil (Loam, clay or sandy) including lift upto 1.50 M and lead upto 30 M. And including filling watering and ramming of excavated earth into the tenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 M. from the foundation trenches (Where machine con not reach/move) For Building work only as in item 251A P.W.D. (SOR) 23 Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR-2018 12.34 24 S/F of 2.5 sq.mm x 3 core cable as per AOR 25 Demolishing R.C.C. Work Manually by mechnical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of E/I. (AOR) 26 Laying old Cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. All complete as per the direction of engineer (AOR) 27 Taking out existing CC interlocking from footpath/central verge, including removal of rubbish etc, disposal of unserviceable material to the dumping ground, for wich payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of E/I. (AOR) 28 S/F of Steel Tubular Pole 11 M long designated 410-SP-56 in 1:3:6 Cement, Concrete graded stone aggregate of 40 mm. Nominal size & foundation including excavation back filling etc. complete in all respects as per direction of E/I.(UPERC-2019 Pg-44) 29 S/F of straight MS Channel 125x65 mm (13.1 per kg) 175 mtr. Long including packing piece clamp & all nuts and bolts fixing on pole. complete in all respects. As per direction of E/I. (UPERC-2019 P-45) 30 S/F of 11 KV pin 12 long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc. complete in all respects as per direction of E/I (UPERC-2019) Pg-39 31 Providing & Laying of 200 mm dia 6 mm thickness thorugh trenchless method including joints of pipe, excavation of thrust pit and receiving pit of required size, cutting and repairing of road with all T & P and the GPS report submitted by the tendere before excavation & back filling with compaction complete as per specification by H.D.D. machine method. Pipe will be installed at minium depth 2 M to 3M below the ground surface or download as per site condition in required slope.(AOR) 32 Supply and fixing of 150 mm. dia. G.I. Pipe B Class for cable duly clamped with supports by 1 Nos. with clamps of 20x3 mm. M.S. Flat, bolts, nuts and washer required for proper completion or work. UPERC-2019 Page-30 33 S/Laying of Heavy density poly ethylene Pipes ISI marked anti radiant grade OD -160 mm dia PN-8 PE 100 grade as per IS Code 4984 with excavation at the depth of 1.20 mtr below ground level i/c the cost of cutting of pipes for making up to length and making jointcomplete in all respects. As per direction of E/I. Rex/Duraline/Time make (AOR) 34 Supply, Insallation, Testing and Commissioning of 185 Sq.mm. 3 Coretype high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment required for proper completion of the work. (KEI/Diatron/Gloster/Universal/Havells.Polycab make) AOR 35 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of upto 120 sq.mm to 400 sq.mm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (DSR-2018) 8.1, P-31 above 120 sq.mm upto 400 sq.mm 36 S/F of jointing of 185 sq.mm outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson/ Make)Outdoor Type. (UPERC ) P-41 37 Supply and fixing of following type plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer- Incharge. UPPWD-2019 (PS No. 504) -1. 185 Sq.mm. 38 S/E testing & commissioning of 63 KVA copper wound outdoor type distribution transformer as per ISS : including inspection fees etc. complete in all respect Make: Crompton/Alstom/ABB/ Schneideras per direction of E/I. (UPER-2019) pg-51

Key Value

Document Fees
INR 2124 /-
EMD
INR 49300.0 /-
Tender Value
INR 24.60 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail