Tender For 48. Supply, Installation, Testing & Commissioning Of Mgps At Hdu/Icu At Sheoganj Distt. Sirohi, 1 Particulars 2 Sitc Of Mgps Pipe Of Medically Grade As Per Bsen-13348 With Third Party Certification From Lloyds/Tuv Degreased (Ie Free From Oi, sirohi-Rajasthan

Medical And Health Services-MAHS has published Tender For 48. Supply, Installation, Testing & Commissioning Of Mgps At Hdu/Icu At Sheoganj Distt. Sirohi, 1 Particulars 2 Sitc Of Mgps Pipe Of Medically Grade As Per Bsen-13348 With Third Party Certification From Lloyds/Tuv Degreased (Ie Free From Oi. Submission Date for this Tender is 25-07-2024. Cutting Crimping and Punching Tools Tenders in sirohi Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43688612
Corrigendum : Tender For 48. Supply, Installation, Testing & Commissioning Of Mgps At Hdu/Icu At Sheoganj Distt. Sirohi, 1 Particulars 2 Sitc Of Mgps Pipe Of Medically Grade As Per Bsen-13348 With Third Party Certification From Lloyds/Tuv Degreased (Ie Free From Oi
Open Tender
Indian
Rajasthan
sirohi
25-07-2024

Tender Documents

Tender Details

Tender For 48. Supply, installation, testing & commissioning Of Mgps At Hdu/Icu At Sheoganj Distt. Sirohi, 1 Particulars 2 SITC of MGPS pipe of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased (ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fittings shall comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 Bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-I 2016. Third party test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure A attached with P.W.D. Electrical BSR 2021 3 SITC of non lubricated ball type Nickel Coated Isolation Valve with adapter & PTFE Seat having quarter turn/Butterfly handle opening of following sizes suitable for flow capacity of required LPM as per the size of valve at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20°C to 130°C. Appropriate Test certificate/report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure A attached with PWD Electrical BSR 2021 4 For 12 MM OD Pipe 5 FOR 15 MM OD Pipe 6 FOR 22 MM OD Pipe 7 FOR 28 MM OD Pipe 8 FOR 42 MM OD Pipe 9 SITC of Gas outlet points Oxy, N2O, (AR-4), (AR-7) and Vaccum (8.7 psig) for dispensing medical gases (oxygen/air/vaccum) at point of use confirming to BSEN ISO 9170-1:2008. The gas outlet are quick connect type , it should have color coding for different gas source and should accept only repective adapters as required.Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The product should be CE Certified/CE Marked. All as per pre approved by Engineer in charge. For additional echnical parameters of products/work, refer Annexure A attached with PWD Electrical BSR 2021 10 SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body, double jacketed with flow gradations CE Marked on it. Desired flow will be setteled through rotary knob. Flow range should be between 0 to 15 lpm & work should be executed as per direction of engineer in charge. Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The product should be CE Certified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure A attached with PWD Electrical BSR 2021. 11 SITC of ward suction unit (Suction controller and collectionJar-600 ml capacity) with posibility to configure required capacity collection jar and should meets the requirements as per BSEN ISO 10079-3:2009. The unit must designed to operate with the vaccum line of MGPS. The collection jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature- 18°C to 50°C with ON/OFF facility. The collection jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121°C for 20 minutes for reuse and provided with auto stop to avoid over spill and contaminatin of the suction source when the jar collection reached optimized level. The complete unit supplied with filter to protect the source and pipe line from bacterial contamination. Appropriate Test certificate/report of product/accessories from OEM shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure A attached with PWD Electrical BSR 2021. 12 SITC of valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with BSEN ISO5211:2001 complete with ball type valves and gauges as required for oxygen compressed air and vaccum line. Appropriate Test certificate/report of product/accessories from OEM shall be submited. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure A attached with PWD Electrical BSR 2021. 13 Three Gas Service 14 SITC of microprocessor based auto alarm (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS zoning. It should monitors the current status of oxygen / compresssed air pressure in distribution pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-I:2007 Appropriate Test certificate/report of product /accessories from OEM Shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure A attached with PWD Electrical BSR 2021. 15 Three Gas Service 16 SITC of Bed Head Panel of 900-1500 MM long made out from high strength extruded aluminium with powder coating with at least 4 Nos 6/16 Amp switch socket and provision for required number of gas outlet points as suggested by the client. Appropriate Test Certificate/Report of product/accessories from OEM shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure A attached with PWD Electrical BSR 2021.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Jun-2024 Date Date 25-07-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 16200.0 /-
Tender Value
INR 8.10 Lakhs /-

Attachment

FileName File Description File Size
f547f6c2-58cf-498f-93a7-53185202fe69.html Tender Notice 0 KB
BOQ_706311.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Tendernotice_2.pdf Tender Document 0 KB

BOQ Items

Name of Work- 48. SITC of MGPS at HDU/ICU at Sheoganj Distt. Sirohi
Sl. No. Item Description
1Particulars
2SITC of MGPS pipe of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased (ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fitting\"s shall comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 Bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-I 2016. Third party test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with P.W.D. Electrical BSR 2021
3SITC of non lubricated ball type Nickel Coated Isolation Valve with adapter & PTFE Seat having quarter turn/Butterfly handle opening of following sizes suitable for flow capacity of required LPM as per the size of valve at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20°C to 130°C. Appropriate Test certificate/report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021
4For 12 MM OD Pipe
5FOR 15 MM OD Pipe
6FOR 22 MM OD Pipe
7FOR 28 MM OD Pipe
8FOR 42 MM OD Pipe
9SITC of Gas outlet points Oxy, N2O, (AR-4), (AR-7) and Vaccum (8.7 psig) for dispensing medical gases (oxygen/air/vaccum) at point of use confirming to BSEN ISO 9170-1:2008. The gas outlet are quick connect type , it should have color coding for different gas source and should accept only repective adapters as required.Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The product should be CE Certified/CE Marked. All as per pre approved by Engineer in charge. For additional echnical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021
10SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body, double jacketed with flow gradations CE Marked on it. Desired flow will be setteled through rotary knob. Flow range should be between 0 to 15 lpm & work should be executed as per direction of engineer in charge. Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The product should be CE Certified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
11SITC of ward suction unit (Suction controller and collectionJar-600 ml capacity) with posibility to configure required capacity collection jar and should meets the requirements as per BSEN ISO 10079-3:2009. The unit must designed to operate with the vaccum line of MGPS. The collection jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature- 18°C to 50°C with ON/OFF facility. The collection jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121°C for 20 minutes for reuse and provided with auto stop to avoid over spill and contaminatin of the suction source when the jar collection reached optimized level. The complete unit supplied with filter to protect the source and pipe line from bacterial contamination. Appropriate Test certificate/report of product/accessories from OEM shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
12SITC of valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with BSEN ISO5211:2001 complete with ball type valves and gauges as required for oxygen compressed air and vaccum line. Appropriate Test certificate/report of product/accessories from OEM shall be submited. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
13Three Gas Service
14SITC of microprocessor based auto alarm (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS zoning. It should monitors the current status of oxygen / compresssed air pressure in distribution pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-I:2007 Appropriate Test certificate/report of product /accessories from OEM Shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.
15Three Gas Service
16SITC of Bed Head Panel of 900-1500 MM long made out from high strength extruded aluminium with powder coating with at least 4 Nos 6/16 Amp switch socket and provision for required number of gas outlet points as suggested by the client. Appropriate Test Certificate/Report of product/accessories from OEM shall be submitted. The product should be CE ertified/CE marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \"A\" attached with PWD Electrical BSR 2021.