}

Tender For 24X7 Ws Scheme In 11 Wards, Surveying Soil Investigation Design And Supply Of All Materials Labour Tp Etc Complete Required For Completion Of Following Works Of 24X7 Water Suuply Scheme 11 Selected Wards Of Nagar Nigam Ayodhya, Supply Of Follo, ayodhya-Uttar Pradesh

Government Departments has published Tender For 24X7 Ws Scheme In 11 Wards, Surveying Soil Investigation Design And Supply Of All Materials Labour Tp Etc Complete Required For Completion Of Following Works Of 24X7 Water Suuply Scheme 11 Selected Wards Of Nagar Nigam Ayodhya, Supply Of Follo. Submission Date for this Tender is 29-06-2024. Wall Construction Tenders in ayodhya Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43643696
Corrigendum : Tender For 24X7 Ws Scheme In 11 Wards, Surveying Soil Investigation Design And Supply Of All Materials Labour Tp Etc Complete Required For Completion Of Following Works Of 24X7 Water Suuply Scheme 11 Selected Wards Of Nagar Nigam Ayodhya, Supply Of Follo
Open Tender
Indian
Uttar Pradesh
Ayodhya
29-06-2024

Tender Details

tender for 24X7 Ws Scheme In 11 Wards, Surveying Soil Investigation Design And Supply Of All Materials Labour Tp Etc Complete Required For Completion Of Following Works Of 24X7 Water Suuply Scheme 11 Selected Wards Of Nagar Nigam Ayodhya, Supply of following sizes and type of pipes with all jointing materials such as socket, rubber gasket as per IS 4984/1995 and IS-8329/2000 or their latest amendment including F.O.R. destination and all taxes and insurance etc. with loading, unloading and stacking all complete. Rates are including Supply of all DI specials required for completion of work. THE Pipe K-7 100 mm dia 150 mm dia 200 mm dia 250 mm dia 300 mm dia 350 mm dia 400 mm dia Carting of following size & type of pipes and specials from departmental store to site of work and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete including testing of pipe lines and cutting of pipes. Including carting and laying/jointing of specials and including shifting of electric cables if any required for completion of work. di Pipe K-7 100 mm dia 150 mm dia 200 mm dia 250 mm dia 300 mm dia 350 mm dia 400 mm dia Excavation of earth for pipeline trenches in Ordinary Soil (Loam, Clay or Sand) with lift up to 1.5 M and lead up to 50 M including filling back the excavated earth into the trenches with watering, ramming and disposal of surplus earth with in Supply and delivery of CI/DI flanged end sluice valve PN-1.0 (MPa) with Body and Bonnet of Cast iron/Ductile Iron GGG 40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-0 ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type AflS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange C. L. DIF Sluice Valve 100 mm dia 150 mm dia 200 mm dia 250 mm dia 300 mm dia 350 mm dia 400 mm dia Supply, Fixing and delivery of CIDI Scour valve PN- 1.6(MPa) with Body and Bonnet of Ductile Iron GGG-40/SG- 400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2, and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-0 ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type AllS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as Supply, Carting and Fixing of Stainless Steel (S.S-304) Landing (Fire Hydrant) Valve (Flanged) IInlet 80mm & Outlet 65mm, as per IS:5290, Flanged Ends to IS:1538. Fire Hydrant 80 mm dia Supply, Carting and Fixing of C.I. Single ball type Air Valve 20 mm dia Carting of following sizes C.I.D./F Sluice Valve and specials from departmental store to site of work and lowering them into the trenches, fixing in position and jointing them with pipelines and testing etc. complete including supply of C. I. DIF Sluice Valve 100 mm dia 150 mm dia 200 mm dia 250 mm dia 300 mm dia 350 mm dia Designing, Supplying, Installing, commissioning & testing of Actuator Operated Isolation Valves, DIDFPN 1.0 rating having data communication feature with PLC SCADA and also transmit data along with controlling and monitoring of valve through M.C.S incorporated with integral Starter & gear box including DI tail pieces with EPDM fully covered wedge and epoxy coat C. L. DIF Sluice Valve 100 mm dia 150 mm dia 200 mm dia 250 mm dia 300 mm dia 350 mm dia 400 mm dia Providing, erecting and commissioning of MS dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long C. L. DIF Sluice Valve 100 mm dia 150 mm dia 200 mm dia 250 mm dia 300 mm dia 350 mm dia Supply of all materials and construction of following chambers as per type design with supply of all labour, T&P Masonary Type Chamber with Precast concrete opening. Fire Hydrant Chamber with Precast concrete opening. Air Valve Chamber with Precast concrete opening. Surface Box Type with Precast concrete opening. dismantling or removing type or road & stacking of useful materials, and disposal of debris upto 8 km lead including supply of all materials BOE Road Cement Concrete Road Bitumen Road Interlocking Tile Road Permanent Reinstatement of following type road as per specification of PVD/Local body. BOE Road (with 40% New Bricks and 60% old Undamaged serviceable bricks) C.C. Road (with 125 mm PCC base of 1:4:8 cement: coarse sand: 40 mm Stone Aggregate and 125 mm Cement Concrete course of 1:1.5:3 cement: coarse sand: 20 mm Bitumen Road in Nagar Nigam 1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 3. Providing, laying, Spreading & Compacting graded stone aggregate to wet mix macadam. (100 mm thickness) 4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surface spreading primer at the rate of 0.75 Kg./Sqm. 5.PIL of 40mm thick DBM with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5% 5a P/L of 30 mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5% 6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG-10 Bitumen Road PVD 1.granular sub-base with material conforming to Grade-l (size range 75 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 3. Providing, laying, Spreading & Compacting graded stone aggregate to wet mix macadam. (150 mm thickness) 4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surface spreading primer at the rate of 0.75 Kg./Sqm. 5.PIL of 50mm thick Dense Bituminous Macadam with 100- 120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 3.4% 5a. Providing and laying tack coat. 6..P/L of 40mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @5.5% 7.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG-10 Interlocking Tile Road (40% New interlocking tile 80 mm thick M 35 Grade and 60% old serviceable tiles, Palin cement concrete in 75 mm thickness 1:6:12 cement:sand: 40 mm coarse stone aggregate in base.) Crossing of road or large Nala or structure or road by trenchless method having casing pipe. 500 mm dia MS pipe upto 2 mtr depth. Nala/Road Crossing Small Rising Main Supply of D.l. pipes (K-9)of following sizełwall thickness with I.S. 8329/2000 or its latest amendments with jointing materials including for destination and all taxes and 150 mm dia DI K-9 Excavation of earth for pipe line trenches with lift upto 1.5 and lead upto 50M filling back the earth into trenches including watering, ramming and disposal of surplus material with in 50M lead etc. complete. Carting from store to site of work following D.I. Pipe with specials, lowering the same into trenches and laying true to alignment and gradient including jointing properly testing of pipe line (but excluding the cost of trenching and cutting of pipe for making the length) etc. complete. 150 mm dia DI K-9 Supply and Fixing of CIIDI flanged end sluice valve PN- 1.6(MPa) with Body and Bonnet of Cast iron/Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-0 ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type AllS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange 150 mm dia DI K-9 Supply and Fixing of following size of C.I. Double orifice type Air Valve 20 mm dia F.O.R. Destination including all taxes and insurance. 150 mm dia DI K-9 Supply of all materials and construct following type sluice valve chambers complete as per type design. (a) Masonary Type S.V. Chamber as per unit estimate (b) Air Valve Chamber as per unit estimate Dismentling of following type of road and stacking of useful materials including supply of all materials, labour, T&P etc. complete. C.C. Road Bitumen Road Interlocking Reinstatement of following type road charges to be paid to PVD/Local body. C.C. Road (with 125 mm PCC base of 1:4:8 cement: coarse sand: 40 mm Stone Aggregate and 125 mm Cement Concrete course of 1:1.5:3-cement: coarse sand: 20 mm Bitumen Road in Nagar Nigam 1.granular sub-base With material conforming to Grade-l (size range 75 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 3. Providing, laying, Spreading & Compacting graded stone aggregate to wet mix macadam. (100 mm thickness) 4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surface spreading primer at the rate of 0.75 Kg./Sqm. 5.PIL of 40mm thick DBM with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5% 5a PIL of 30 mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5% 6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG-10 Bitumen Road in PVD 1.granular sub-base With material conforming to Grade-l (size range 75 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25 125 mm layer thickness. 3. Providing, laying, Spreading & Compacting graded stone aggregate to wet mix macadam. (150 mm thickness) 4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surface spreading primer at the rate of 0.75 Kg./Sqm. 5.PIL of 50mm thick Dense Bituminous Macadam with 100- 120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premised with bituminous binder VG 30 @ 3.4% 5a. Providing and laying tack coat. 6..PIL of 40mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @5.5% 7. Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG-10 Interlocking Tile Road (40% New interlocking tile 80 mm thick M 35 Grade and 60% old serviceable tiles, Palin cement concrete in 75 mm thickness 1:6:12 cement:sand: 40 mm coarse stone aggregate in base.) Supply of all material, labour, T&P and construct RCC thrust blocks at the bends of DI pipe etc. complete.(as per CPHEEO specuification and departmental design) R.C.C. work in 1:1.5:3 (cement: coarse sand 20 mm aggreagate) mix. Rates are inclusive of all materials, supply and installation of scaffolding and shuttering, labours and Supply and placing of HYSD bars grade>= Fe 500 in RCC work, including all material, labours and T&P Bypass Arrangement from rising main to distribution main including supply of sluice valve, A/F tee, CI/DI flange spigot, distance piece etc and carting, laying, jointing of all material, specials. This include all material, labour T&P. Excluding cost of Rising main, its laying jointing and excavation. 150 mm to 400 mm dia DIK 9 150 mm to 250 mm dia THICK 150 mm to 350 mm dia DIK 9 Interconnection of rising main with tubewell including supply carting, laying & jointing of sluice valve, Tee, tailpiece, bend and other specials etc. including all labour, material T&P. As per unit estimate 150 mm dia HOUSE CONNECTION IN NEV PIPE LINE Residential House Connection Materials 20mm dia (OD) HDPE pipe (12.5KG/CM2) 15 mm dia (OD) Gl pipe Class-B Providing & supplying of clamp saddle (DI strap saddle) for House service connections shall be of fastened strap type with threaded outlet for service connection. Clamp saddle shall be suitable for nominal size of distribution mains pipe line. The strap shall be elastomer coated (insulated) type for firm grip on pipe as well as to protect the coating on the pipe and to insulate the unidentical metals. The saddle shall be single strap type up to pipe size of NB 600 and service outlet 15mm, 20mm & 25mm. Fasteners shall be of threaded nut bolt washer type. The sealing between the saddle and mains shall be obtained by using a profiled elastomer seal matching to the curvature of the pipe. The seal shall be elastomer type, suitable for all potable water application. The material of construction of the body, straps, fasteners etc. shall be non-corrosive material sucha as engineering plastic (PE/PP) or stainless steel of a combination of both and shall ne inclusive of all cost such as testing, 133 S. No. items unit rates in Rs. inspection charges, transporation up 100 NB x 15 mm, 20 mm, 25mm 150 NB x 15 mm, 20 mm, 25mm 200 NB x 15 mm, 20 mm, 25mm 250 NB x 15 mm, 20 mm, 25mm 300 NB x 15 mm, 20 mm, 25mm 350 NB x 15 mm, 20 mm, 25mm 400 NB x 15 mm, 20mm, 25 mm Labour Making ferrule connection in. Distribution mains with saddle piece, service connections, fittings, and fixing of G.M. Ferrule of 15 mm size inculding tapping the main and.cutting threading and fitting Gl pipe and specials including supply of all binding materials such as white lead and teflon tape including making hole in wall and plastering the same with mortar including cost of mortar and also including the cost of crossing the drain including all labour, Commercial House Connection Materials 25mm dia (OD) HDPE pipe (12.5KG/CM2) 20 mm dia (OD) GI pipe Class-B Providing & supplying of clamp saddle (DI strap saddle) for House service connections shall be of fastened strap type with threaded outlet for service connection. Clamp saddle shall be suitable for nominal size of distribution mains pipe line. The strap shall be elastomer coated (insulated) type for firm grip on pipe as well as to protect the coating on the pipe and to insulate the unidentical metals. The saddle shall be single strap type up to pipe size of NB 600 and service outlet 15mm, 20mm & 25mm. Fasteners shall be of threaded nut bolt washer type. The sealing between the saddle and mains shall be obtained by using a profiled elastomer seal matching to the curvature of the pipe. The seal shall be elastomer type, suitable for all potable water application. The material of construction of the body, straps, fasteners etc. shall be non-corrosive material sucha as engineering plastic (PE/PP) or stainless steel of a combination of both and shall ne inclusive of all cost such as testing, 133 S. No. items unit rates in Rs. inspection charges, transporation up to site, transit, insurance, loading, unloading, stacking etc. 100 NB x 15 mm, 20 mm, 25 mm, 50mm, 65mm 150 NB x 15 mm, 20 mm, 25 mm, 50mm, 65mm 200 NB x 15 mm, 20 mm, 25mm, 50mm, 65mm 250 NB x 15 mm, 20 mm, 25mm, 50mm, 65mm 300 NB x 15 mm, 20 mm, 25mm, 50mm, 65mm 350 NB x 15 mm, 20 mm, 25mm, 50mm, 65mm Labour Making ferrule connection in Distribution mains with saddle piece, service connections, fittings, and fixing of G.M. Ferrule of 15 mm size inculding tapping the main and.cutting threading and fitting Gl pipe and specials including supply of all binding materials such as white lead and teflon tape including making hole in wall and plastering the same with mortar including cost of mortar and also including the cost of crossing the drain including all labour, Supply and installation of Electromagenetici Ultrasonic AMI based domestic/Commercial water meter with Wi-fi /wireless metering. Cost includes complete setup of automatic meter reading solution, development of software mobile application for metering and billing. AMI module specification shall be approved by department.All items related to water meter shall be as per direction of Engineer - DN 15 (Dom., Comm.) DN 25 (Commercialfinstitutional) DN 50 (Commercial/institutional) DN 65 (Commercialfinstitutional) Over Head Tank RENOVATION OF EXISTING OVER HEAD TANKS WHICH INCLUDES FOLLOVING ITEMS: Providing and erection of scaffolding and shuttering material like challi, gurra, nail, bans, ballia, patra etc. required for complete of work on all surgace area of OHT from top dome to G.L. so as to give strong and safe plateform to workers to work on all part of OHT for repair and strengthning as per direction of engineer in charge. Surface Preparation- The surface of structure to be treated for strengthning shall be reoughened properly either by raking joints or by haching the cement concrete surface with a specially made haching tool or otherwise alternatively to make the surface rough and dust free by providing spatter key or wire brush. Injection grouting in vertical surface/wall placing and fixing nozzle by drilling machine in tank wall having minimum dia of nozzle 15mm and provide on a regular interval not exceeding Im including construction joints. Injection of pidicrete AM (Ploymer based on shrinkage high strength grout) admisxed with cement through nozle under pressure by sump @ 250gms per bag of cement sealing the nozzle after frounting with Ploymer product mixed with cement, making tank body in working and seapage free condition. Change of steel ladder inside the tank, repair of MH cover of top dome, change of mosqeuto jali with new one complete. Supply and fixing of 20mm dia G.I.Pipe railing in stair case and balcony. (Taking only 25% new and 75% old OP Z-1A Capacity 150 KL/18 M OP Z-2 Capacity 300 KL/20 M OP Z-3A Capacity 1250 KL/20 M OP Z-4A Capacity 1250 KL/20 M OP Z-5 Capacity 200 KL/18 M Construction of new pumphouse( 3.6 x 3.0 m) cum chlorinator( size 2.8 x 1.8 m) As per departmental drawing & Construction of boundary wall around waterworks etc as per type design including supply of all Materials, Labour, Tools and Plants etc. complete. Supply & fixing of 3.60 M wide MS Gate and 1.2 m wide MS gate including fabrication and supply of steel and construction of boundary pillars all complete. Earth filling in plinth including filling, dressing and ramming earth or sand or bajari or ballast or kankar or shingle. This include supply of earth from 12 km lead. Construction of interlocking approach road including supply of all materials, labour, tools and plants etc, complete. Including construction of Sub base (P.C.C. 1:6:12 (75mm) thick)) and C.C. edging of 100 mm height. Interlocking tiles shall be rubber moulded 80 mm thick minimum M 35 grade. Water works campus development including landscaping, horticulture of open land as per direction of engineer in Construction of Admin Building with Training center. Rate is per sqm of plinth area. Building shall be RCC framed structure including all amenities like water supply, drainage, fire fighting, electrical fittings( min 20 fan, min 10 exhaust fans, min. 10 Nos A.C., min. 100 LEDs, min 5 LED displays 55 inch size etc.), required fall cellingsł wall panneling including all required furniture for 40 persons in confrence rooms and other officers room as per standerd All specification shall be conforming to PWD/CPWD/C&DS Construction of master control station. Rate is per sqm of plinth area. Building shall be RCC framed structure including all amenities like water supply, drainage, fire fighting, electrical fittings. required fall cellings! wall panneling including all required furniture for 10 persons in confrence rooms and other officers room as per standerd All specification shall be conforming to PWD/CPWD/C&DS Construction of booster pump room as per department approved drawing and design rate per sqm of plinth area. E&M Vorks OP Zone 1 Discharge 1200 LPM 54 m & 60 M Head Transportation of Rig Machine & its T&Plequipments to the site of work including loading & unloading, baricating, erection & dismantling etc. Transportation of Air Compressor and its T&P including loading & unloading, erection & dismantling etc. Transportation of OP Unit and its T&P including loading & unloading, erection & dismantling etc. Supply including loading & unloading of TV assembly of MSERV pipe. 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 200mm dia M.S reducer 16 mm thick, 1 no M.S. well cap 12mm thick, required M.S. ring 100×12mm thick, M.S. S/l clamp, T.W. Support (I Section) etc complete 200mm dia MSERW 7.1mm thick plain slotted pipe including with required M.S ring 100×12mm thick, 1 no M.S. bail plug, required center guide etc comp in all respect. Drilling of Bore (Including water arrangement) Logging of Bore Drilling of 600mm dia bore from G.L. to 45 m BGL. Drilling of 500mm dia bore from 45 m BGL to 100m BGL, Drilling of 500mm dia bore from 101m BGL to 165m BGL. Welding and lowering of tw Assembly including electrodes welding set and generator etc. required for completion of work) as per following: Lowering of 300mm X 200mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 42 m BGL. Lowering of 200mm die MSERW plain/slotted pipe 7.1mm thick from 42 m BGL to 100m BGL. Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. Supply of Pea Gravel Size 1.6mm to 4.80mm of Lalkuwan quarry duly screened, washed and proper stacking at site. Development of Tubewell Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. By Air compressor of 250 PSI capacity including T&P, labour and material required for completion of work. Cutting of T.W. cover by gas cutter, re-welding of T.W.cover by Electric welding after complete development of work. By 3 Cusec OP Unit or Sutaible capacity including T&P, labour and material required for completion of work. Chemical and bacteriological test Supply, inataliation, Commissioning & Testing of Pumping Plant, Chlorinating Plant & Crabilini 1200 LPM, 60 m head (or suitable head as per site condition and direction of engineer in charge) 2900rpm submersible clear water pumping plant suitable to operate on 415+%5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) along with Main piping and valves of 150 MM dia 5.4 mm thick M.S. column pipe 30m (or suitable length as per site condition and direction of engineer in charge), D/F Pipe 1.0m long 01 No., D/F Pipe 1.5m long 02 No., DIF Bend 01 No., AfF Tee, 01 No., DiF Reflex Valve 1No., Enlarger Reducer 1 No, Gauges with air line fittings, Earthing material, tool kit, 2 Ton Chain pully block, Internal Electrification of pump house, Supply & Installation of sutable size armoured 1200 LPM, 54 m head (or suitable head as per site condition and direction of engineer in charge) 2900rpm submersible clear water pumping plant suitable to operate on 415+%5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) along with Main piping and valves of 150 MM dia 5.4 mm thick M.S. column pipe 30m (or suitable length as per site condition and direction of engineer in charge), D/F Pipe 1.0m long 01 No., D/F Pipe 1.5m long 02 No., DIF Bend 01 No., AfF Tee, 01 No., DiF Reflex Valve 1No., Enlarger Reducer 1 No, Gauges with air line fittings, Earthing material, tool kit, 2 Ton Chain pully block, SCADA Compatable Chlorinating Systeme, Internal Electrification of pump house, Supply & Installation of sutable size armoured cable Fully automatic Servo Voltage Stabilizer having suitable capacity as per actual site requirements and as per direction of Engineer in Charge fully copper winding 3- phase A.C. Supply 50 Hz.input voltage 90-150 V output voltage 360-440 V with T/F oil power cable & earthing etc.complete in all CE / UL certified Intelligent smart energy meter Motor Operated Actuator with Sluice Valve (150mm) CE / UL certified Electromagnetic flowmeter of size:100mm CE / UL certified Electromagnetic flowmeter of size:150mm Digital Soft starter (30 KW or suitable size as per site condition and direction of engineer in charge) Digital Soft starter (22 KW or suitable size as per site condition and direction of engineer in charge) Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (160 Amps) Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (125 Amps) CE UL certified Hydrostatatic type sub soil water level transmitter CEFUL certified Pressure Transmitter Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse and OHT SUPPLY INSTALLATION TESTING COMMISSIONING OF SCADA FOR New, TIV train Fully Automation of T/W through SCADA complete in all respect e.g. Supply installation Testing of all Required RTU, Wireless Communication Module, Control Panel, PLC, Programming, Software, Licences, wiring etc complete in all respect including mobile based app development and interconnection with LCS, MCS Central Control Room Ayodhya and Central Control Room Lucknow as per 24x7 Trial & Run of pumping plant Three Month Trial & Run, handing over of T/W, Pumping plant, accessories with Sodium hypochloride solution, vehicle, watch & ward. ESR Automation (OP Zone-1 &1-A) Automation of Existing OHT and associated infrastructure like existing Tubewell, Related Valves, Chlorination System etc including repairing of existing equipments if necessary and supply and fixing of DG Set (50% Standby) with LT Panel interlock and AMF Panel Design, SITC of Booster Pumps with 50% stand-by of peak water dermand along with main piping and actuator valves and bypass arrangement, extra pressure transmitter, VFD drive, PLC Panel, TDS Analyser, power and control wiring complete in all respect as per 24x7 water supply Flow meter / Bulk Water Meter 350 mm Flow meter / Bulk Water Meter 400 mm Flow! Presssure Control valve 350 mm Flow! Presssure Control valve 400 mm SCADA Compatable Chlorinating System with separate controlled dosing Residual Chlorine Analyser Pressure Transmitter with required power arrangement TDS/PH Analyser with Data Logger Trial & Run of ESR Zone 1 & 1A Three Month Trial & Run, handing over of ESR with all consumables and Sodium hypochloride solution, vehicle, watch & ward. OP Zone 2A Discharg 800 LPM 54 M Head Transportation of Rig Machine & its T&Plequipments to the site of work including loading & unloading, baricating, erection & dismantling etc. Transportation of Air Compressor and its T&P including loading & unloading, erection & dismantling etc. Transportation of OP Unit and its T&P including loading & unloading, erection & dismantling etc. Supply including loading & unloading of TV assembly of MSERV pipe. 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 150mm dia M.S reducer 16mm thick, 1 no M.S. well cap 12mm thick, required M.S. ring 100×12mm thick, M.S. S/l clamp, T.W. Support (I Section) etc complete 150mm dia MSERW 7.1mm thick plain /slotted pipe including with required M.S ring 100×12mm thick, 1no M.S. bail plug, required center guide etc comp in all respect. Drilling of Bore (Including water arrangement) Logging of Bore Drilling of 600mm dia bore from G.L. to 45 m BGL. Drilling of 500mm dia bore from 45 m BGL to 100m BGL. Drilling of 500mm dia bore from 101m BGL to 165m BGL Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following: Lowering of 300mm X 150mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 150m BGL. Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 42 m BGL. Lowering of 150mm die MSERW plain/slotted pipe 7.1mm thick from 42 m BGL to 100m BGL. Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. Supply of Pea Gravel Size 1.6mm to 4.80mm of Lalkuwan quarry duly screened, washed and proper stacking at site. Development of Tubewell Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. By Air compressor of 250 PSI capacity including T&P, labour and material required for completion of work. Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. By 3 Cusec OP Unit or Sutaible capacity including T&P, labour and material required for completion of work. Chemical and bacteriological test Supply, Inatallation, Commissioning & Testing of Pumping Plant, Chlorinating Plant & Stabilizer (For New TW) 1800 LPM, 54 m head (or suitable head as per site condition and direction of engineer in charge) 2900rpm submersible clear water pumping plant suitable to operate on 415+%5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) along with Main piping and valves of 100 MM dia 5.4 mm thick M.S. column pipe 30m (or suitable length as per site condition and direction of engineer in charge), D/F Pipe 1.0m long 01 No., D/F Pipe 1.5m long 02 No., D/F Bend 01 No., A/F Tee, 01 No., D/F Reflex Valve 1No., Enlarger / Reducer 1 No, Gauges with air line fittings, Earthing material, tool kit, 2 Ton Chain pully block, SCADA Compatable Chlorinating Systeme, Internal Electrification of pump house, Supply & Installation of sutable size armoured cable including lugs itc. Complete works & Painting etc.. Fully automatic Servo Voltage Stabilizer having (30 KVA or suitable capacity as per actual site requirements and as per direction of Engineer in Charge) fully copper winding 3- phase A.C. Supply 50 Hz.input voltage 90-150 V output voltage 360-440 V with T/F oil, power cable & earthing etc.complete in all respect. CE/UL certified Intelligent smart energy meter Motor Operated Actuator with Sluice Valve (100mm) CE/UL certified Electromagnetic flowmeter of size:100mm Digital Soft starter (15 KW (or suitable size as per site condition and direction of engineer in charge) Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC 60947-6-1) (100 Amps) CE UL certified Hydrostatatic type sub soil water level transmitter CE/UL certified Pressure Transmitter Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse and OHT SUPPLY, INSTALLATION TESTING & COMMISSIONING OF SCADA FOR New, T/W & ESR Fully Automation of T/W through SCADA complete in all respect e.g. Supply installation Testing of all Required RTU, Wireless Communication Device, Control Panel, PLC, Programming, Software, Licences, wiring etc complete in all respect including mobile based app development and interconnection with LCS, MCS Central Control Room Ayodhya and Central Control Room Lucknow as per 24x7 water supply requirements Trial & Run of pumping plant Three Month Trial & Run, handing over of T/W, Pumping plant, accessories with Sodium hypochloride solution, vehicle, watch & ward ESR Automation (OP Zone-2 &2-A) Automation of Existing OHT and associated infrastructure like existing Tubewell, Related Valves, Chlorination System etc including repairing of existing equipments if necessary and supply and fixing of DG Set (50% Standby) with LT Panel interlock and AMF Panel Design, SITC of Booster Pumps as per 24x7 water supply requirements with 50% stand-by of peak water demand along with main piping and actuator valves and bypass arrangement, extra pressure transmitter, VFD drive, PLC Panel, TDS Analyser, power and control wiring complete in all respect Considering all DMAs. Flow meter/Bulk Water Meter 150 mm Flow meter/Bulk Water Meter 200 mm Flow meter/Bulk Water Meter 250 mm Flow/ Presssure Control valve 150 mm Flow/ Presssure Control valve 200 mm Flow/ Presssure Control valve 250 mm SCADA Compatable Chlorinating System with separate controlled dosing Residual Chlorine Analyser Pressure Transmitter with required power arrangement TDS/PH Analyser with Data Logger Trial & Run of ESR Zone 2 & 2A Three Month Trial & Run, handing over of ESR with all consumables and Sodium hypochloride solution, vehicle, watch & ward. OP Zone 3 Discharg1200 LPM 54 m & 60 M Head Transportation of Rig Machine & its T&P/equipments to the site of work including loading & unloading, baricating, erection & dismantling etc. Transportation of Air Compressor and its T&P including loading & unloading, erection & dismantling etc. Transportation of OP Unit and its T&P including loading & unloading, erection & dismantling etc. Supply including loading & unloading of TW assembly of MSERW pipe. 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 200mm dia M.S reducer 16mm thick, 1 no M.S. well cap 12mm thick, required M.S. ring 100X12mm thick, M.S. SA clamp, T.W. Support (I Section) etc complete in all respect 200mm dia MSERW 7.1mm thick plain /slotted pipe including with required M.S ring 100X12mm thick, 1 no M.S. bail plug, required center guide etc comp in all respect. Drilling of Bore (Including water arrangement) Logging of Bore Drilling of 600mm dia bore from G.L. to 45 m BGL. Drilling of 500mm dia bore from 45 m BGL to 100m BGL. Drilling of 500mm dia bore from 101m BGL to 165m BGL. Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following: Lowering of 300mm X 200mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 150m BGL Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 42 m BGL. Lowering of 200mm die MSERW plain/slotted pipe 7.1mm thick from 42m BGL to 100m BGL. Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. Supply of Pea Gravel Size 1.6mm to 4.80mm of Lalkuwan quarry duly screened, washed and proper stacking at site. Development of Tubewell Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. By Air compressor of 250 PSI capacity including T&P, labour and material required for completion of work. Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. By 3 Cusec OP Unit or Sutaible capacity including T&P, labour and material required for completion of work. Chemical and bacteriological test Supply, Inatallation, Commissioning & Testing of Pumping Plant, Chlorinating Plant & Stabilizer (For New TW) 1200 LPM, 60 m head (or suitable head as per site condition and direction of engineer in charge) 2900rpm submersible clear water pumping plant suitable to operate on 415+%5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) along with Main piping and valves of 150 MM dia 5.4 mm thick M.S. column pipe 30m (or) suitable length as per site condition and direction of engineer in charge), D/F Pipe 1.0m long 01 No., D/F Pipe 1.5m long 02 No., D/F Bend 01 No., A/F Tee, 01 No., D/F Reflex Valve 1No., Enlarger / Reducer 1 No, Gauges with air line fittings, Earthing material, tool kit, 2 Ton Chain pully block, SCADA Compatable Chlorinating Systeme, Internal Electrification of pump house, Supply & Installation of sutable size armoured cable including lugs itc. Complete works & Painting etc. 1200 LPM, 54 m head (or suitable head as per site condition and direction of engineer in charge) 2900rpm submersible clear water pumping plant suitable to operate on 415+%5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) along with Main piping and valves of 150 MM dia 5.4 mm thick M.S. column pipe 30m (or suitable length as per site condition and direction of engineer in charge), D/F Pipe 1.0m long 01 No., D/F Pipe 1.5m long 02 No., D/F Bend 01 No., A/F Tee, 01 No., D/F Reflex Valve 1No., Enlarger / Reducer 1 No, Gauges with air line fittings, Earthing material, tool kit, 2 Ton Chain pully block, SCADA Compatable Chlorinating Systeme, Internal Electrification of pump house, Supply & Installation of sutable size armoured cable including lugs itc. Complete works & Painting etc. Fully automatic Servo Voltage Stabilizer having (40 KVA or suitable capacity as per actual site requirements and as per direction of Engineer in Charge) fully copper winding 3- phase A.C. Supply 50 Hz.input voltage 90-150 V output voltage 360-440 V with T/F oil, power cable & earthing etc.complete in all respect. CE/UL certified Intelligent smart energy meter Motor Operated Actuator with Sluice Valve (150mm) CE/UL certified Electromagnetic flowmeter of size:150mm Digital Soft starter (30 KW (or suitable size as per site condition and direction of engineer in charge) Digital Soft starter (22 KW (or suitable size as per site condition and direction of engineer in charge) Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC 60947-6-1) (160 Amps) Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC 60947-6-1) (125 Amps) CE/UL certified Hydrostatatic type sub soil water level transmitter CE/UL certified Pressure Transmitter Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse and OHT SUPPLY, INSTALLATION TESTING & COMMISSIONING OF SCADA FOR New, T/W & ESR Fully Automation of T/W through SCADA complete in all respect e.g. Supply installation Testing of all Required RTU, Wireless Communication Device, Control Panel, PLC, Programming, Software, Licences, wiring etc complete in all respect including mobile based app development and interconnection with LCS, MCS Central Control Room Ayodhya and Central Control Room Lucknow as per 24x7 water supply requirements Trial & Run of pumping plant Three Month Trial & Run, handing over of T/W, Pumping plant, accessories with Sodium hypochloride solution, vehicle, watch & ward. ESR Automation(OP Zone-3 &3-A) Automation of Existing OHT and associated infrastructure like existing Tubewell, Related Valves, Chlorination System etc including repairing of existing equipments if necessary and supply and fixing of DG Set (50% Standby) with LT Panel interlock and AMF Panel Design, SITC of Booster Pumps as per 24x7 water supply requirements with 50% stand-by of peak water demand along with main piping and actuator valves and bypass arrangement, extra pressure transmitter, VFD drive, PLC Panel, TDS Analyser, power and control wiring complete in all respect Considering all DMAs. Flow meter/Bulk Water Meter 250 mm Flow meter/Bulk Water Meter 300 mm Flow/ Presssure Control valve 250 mm Flow/ Presssure Control valve 300 mm SCADA Compatable Chlorinating System with separate controlled dosing Residual Chlorine Analyser Pressure Transmitter with required power arrangement TDS/PH Analyser with Data Logger Trial & Run of ESR Zone 2 & 2A Three Month Trial & Run, handing over of ESR with all consumables and Sodium hypochloride solution, vehicle, watch & ward ESR Automation (OP Zone-4 &4-A) Automation of Existing OHT and associated infrastructure like existing Tubewell, Related Valves, Chlorination System etc including repairing of existing equipments if necessary and supply and fixing of DG Set (50% Standby) with LT Panel interlock and AMF Panel Design, SITC of Booster Pumps as per 24x7 water supply requirements with 50% stand-by of peak water demand along with main piping and actuator valves and bypass arrangement, extra pressure transmitter, VFD drive, PLC Panel, TDS Analyser, power and control wiring complete in all respect Considering all DMAs. Flow meter/Bulk Water Meter 350 mm Flow meter/Bulk Water Meter 400 mm Flow/ Presssure Control valve 350 mm Flow/Presssure Control valve 400 mm SCADA Compatable Chlorinating System with separate controlled dosing Residual Chlorine Analyser Pressure Transmitter with required power arrangement TDS/PH Analyser with Data Logger Trial & Run of ESR Zone 4 & 4A Three Month Trial & Run, handing over of ESR with all consumables and Sodium hypochloride solution, vehicle, watch & ward ESR Automation(OP Zone-5) Automation of Existing OHT and associated infrastructure like existing Tubewell, Related Valves, Chlorination System etc including repairing of existing equipments if necessary and supply and fixing of DG Set (50% Standby) with LT Panel interlock and AMF Panel Design, SITC of Booster Pumps as per 24x7 water supply requirements with 50% stand-by of peak water demand along with main piping and actuator valves and bypass arrangement, extra pressure transmitter, VFD drive, PLC Panel, TDS Analyser, power and control wiring complete in all respect Considering all DMAs. Flow meter/Bulk Water Meter 200 mm Flow meter/Bulk Water Meter 250 mm Flow/ Presssure Control valve 200 mm Flow/ Presssure Control valve 250 mm SCADA Compatable Chlorinating System with separate controlled dosing Residual Chlorine Analyser Pressure Transmitter with required power arrangement TDS/PH Analyser with Data Logger Trial & Run of ESR Zone 5 Three Month Trial & Run, handing over of ESR with all consumables and Sodium hypochloride solution, vehicle, watch & ward HSD Oil for Operation of DG Sets During Trail and Run as per Actual Requirement for all zone SUPPLY, INSTALLATION TESTING & COMMISSIONING OF SCADA MCS (MASTER CONROL STATION) FOR ZONE-01 TO 3 Development of existing SCADA package of UPJN at Ayodhya for integration of new RTU stations & upgradation for required tags & screens etc. complete in all respects. Provision for the development of applications with commissioning in server for data acquisition, transmitting and reporting of Data at existing SCADA & UPJN server from the devices(having different data format and conversions) installed at Pumping stations, SCADA and Control valve data to be transmitted to server via device, which would be compatible with ALL browsers on Mac, PC, Linux, and mobile devices capable of displaying HTML5 and executing JavaScript, including: Chrome, Firefox, Safari, Internet Explorer, Mobile Safari and Chrome on iOS, Mobile browsers on Android. Utilises open standards for HTML5, JavaScript, and CSS. Unique markup option quickly adds live data to existing HTML pages. Programmatic JS interface allows for advanced application UI development. Supports authentication and secure communications over SSL. Requires no plugins, Java applets, or ActiveX controls to execute, just point your browser to your web application to start. Requires no compilation or packaging for deployment, supports file copy deployment or integration with your own deployment methods. Real time data need to be delivered directly to browser, reducing load on your web application server. Data to be automatically connected/transferred to UPJN server. Data security should be maintained through encryption. Scheduling of periodical Data backup etc all complete as per direction of Engineer in charge. Cyber security auding and certifying for web hoisting towards web application as per direction of Engineer in charge. Supply, installation, testing & commissioning of Artificial Intelligence platform to monitor and modulate the instruments in real time for dynamically reconfigurable DMAs. Supply & Trail of Leak Detection Device for Underground Pipeline. SITC of Server in admin building with required hardware e.g. Desktop PC, Display, Airconditioner, Database Backup Arrangement along with System required compatible for complete Ayodhya city water supply and Sewerage System SCADA Data backup and data management for minimum 05 years data backup. SCADA MCS (MASTER CONROL STATION) with Interactive Display for control room including required accessories, workstation, Desktop PC, Printers and Furniture as per Direction of Engineer Incharge Complete in all respect.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-06-2024 Date Extention Date 29-06-2024

Key Value

Document Fees
INR 23600 /-
EMD
INR 8467000.0 /-
Tender Value
INR 84.66 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail