}

Tender For Special Repair And Maintenance Work Of Electrical At Esic Hospital Choudwar Odisha, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Rece, Cuttack-Odisha

Government Departments has published Tender For Special Repair And Maintenance Work Of Electrical At Esic Hospital Choudwar Odisha, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Rece. Submission Date for this Tender is 20-06-2024. Electrical Maintenance Tenders in Cuttack Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

43642161
Tender For Special Repair And Maintenance Work Of Electrical At Esic Hospital Choudwar Odisha, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Rece
Open Tender
Indian
Odisha
Cuttack
20-06-2024

Tender Details

Tender for special repair and maintenance work of electrical at ESIC Hospital Choudwar Odisha, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Group A 3 Group B 4 Group C 5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 6 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 7 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 8 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 9 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 10 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 11 5/6 A switch 12 15/16 A switch 13 3 pin 5/6 A socket outlet 14 6 pin 15/16 A socket outlet 15 2 way 5/6 A switch ( For Stair Light Control) 16 TV antenna socket outlet 17 Bell push 18 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 19 Single Pole 20 Double pole 21 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 22 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 23 1 or 2 Module (75mmX75mm) 24 3 Module (100mmX75mm) 25 6 Module (200mmX75mm) 26 8 Module (125mmX125mm) 27 12 Module (200mmX150mm) 28 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) 29 12 way, Double door 30 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 31 63 A 32 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 33 Supplying and fixing brass batten/ angle holder includingconnection etc. as required. 34 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 35 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 36 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 37 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 38 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 39 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 40 For GST 18% add Multiplying Factor @1.0633, Then Total 41 Supplying with fitting and fixing Single Phase D.O.L Starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. Overload Relay Range 3.8 - 6.0 Amps for 2.2 KW 42 Supplying & erecting LED 20W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic drivercomplete 43 Supply and Installation of 12 watt LED Bulb complete work in all respect. 44 Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENTmake) 45 Supply and Installation of Wall Bracket light complete work in all respect. 46 Wiring Work 47 Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable GI box and earthing thepoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. 48 Group A 49 Group B 50 Group C 51 Rewiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. 52 Group A 53 Group B 54 Group C 55 Wiring for twin control light point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVCinsulated copper conductor single core cable etc. as required. 56 Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mmFRLS PVC insulated copper conductor single core cable for loopearthing as required. 57 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. 58 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 59 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 60 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 61 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 62 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 63 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mmsolid copper conductor PE insulated, shielded with fine tinnedcopper braid and protected with PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required. 64 Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 65 25 mm 66 40 mm 67 50 mm 68 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. 69 5/6 A switch 70 2 way 5/6 A switch 71 15/16 A switch 72 3 pin 5/6 A socket outlet 73 6 pin 15/16 A socket outlet 74 TV antenna socket outlet 75 Bell push 76 Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. 77 Supplying and fixing modular blanking plate on the existingmodular plate & switch box excluding modular plate asrequired. 78 Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required. 79 1 or 2 Module (75mmX75mm) 80 3 Module (100mmX75mm) 81 6 Module (200mmX75mm) 82 8 Module (125mmX125mm) 83 12 Module (200mmX150mm) 84 Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. asrequired. 85 Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet coveron the fan box etc. as required. 86 Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required.Upto 450 mm sweep 87 Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes. 88 Supplying and fixing PVC batten/ angle holder includingconnections etc. as required. 89 DB PANEL/MCB PANEL/ LT Panel Work 90 Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. 91 100 A,30KA,FPMCCB 92 125 A,36KA,FPMCCB 93 250 A,36KA,FPMCCB 94 400 A,50KA,FPMCCB 95 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 96 8 way , Double door 97 12 way , Double door 98 16 way, Double door 99 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 100 Single pole 101 Double pole 102 Supplying and fixing following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. 103 40 A 104 63 A 105 Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing andcommissioning etc. as required. 106 40 A 107 63 A 108 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. asrequired. 63 A 109 Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. 110 Supplying and fixing TP sheet steel enclosure on surface/ recessalong with 16/25/32 A 415 V C curve TP MCB complete withconnections, testing and commissioning etc. as required. 111 Providing and fixing M.V. danger notice plate of 200 mm X 150mm, made of mild steel, at least 2 mm thick, and vitreousenameled white on both sides, and with inscription in single redcolour on front side as required. 112 Supplying and fixing Cable End Box (Loose Wire Box) suitable forfollowing single pole and neutral, sheet steel, MCB distributionboard, 240 Volts, on surface/ recess, complete with testing andcommissioning etc. as required. 113 For 8 way, Double door SPN MCBDB 114 For 14 way, Double door SPN MCBDB 115 Supplying, installing on wall, testing and commissioning offollowing capacity rising mains made of 1.6mm thick IP 42 sheetsteel enclosure duly painted with powder coating, wall straps,fully PVC insulated 4 Nos aluminium bus bars having currentdensity of 130 A/ sq cm at nominal current rating inconvenient sections and suitable for 415 V, 3 phase, 4 wire, 50Hz, A.C. supply with extension joints, fire proof barriers,expansion joints, thrust pads including jointing and earthingwith 2 runs of galvanised iron strips etc. as required. (Risingmains confirming to IS 8623, TEC 439) 116 200 A (S.C. rating for 1 sec - 15 kA) 117 400 A (S.C. rating for 1 sec - 15 kA) 118 Supplying and installing following size of perforated HotDipped Galvanised Iron cable tray (Galvanisation thickness notless than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required. 119 225 mm width X 50 mm depth X 1.6 mm thickness 120 300 mm width X 50 mm depth X 1.6 mm thickness 121 450 mm width X 50 mm depth X 2.0 mm thickness 122 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray bends (galvanisation not less than50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required. 123 225 mm width X 50 mm depth X 1.6 mm thickness 124 300 mm width X 50 mm depth X 1.6 mm thickness 125 450 mm width X 50 mm depth X 2.0 mm thickness 126 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray Tee (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceilingwith G.I. suspenders including G.I. bolts & nuts, etc. as required. 127 225 mm width X 50 mm depth X 1.6 mm thickness 128 300 mm width X 50 mm depth X 1.6 mm thickness 129 450 mm width X 50 mm depth X 1.6 mm thickness 130 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray Cross member(galvanisation notless than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etcas required. 131 225 mm width X 50 mm depth X 1.6 mm thickness 132 300 mm width X 50 mm depth X 1.6 mm thickness 133 450 mm width X 50 mm depth X 1.6 mm thickness 134 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray Reducer (galvanisation not lessthan 50 microns) with perforation not more than17.5%, inconvenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etcas required. 135 225 mm width X 50 mm depth X 1.6 mm thickness 136 300 mm width X 50 mm depth X 1.6 mm thickness 137 450 mm width X 50 mm depth X 1.6 mm thickness 138 Earthing and Lightining Arrester 139 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 140 Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required. 141 Supplying and laying 6 SWG G.I. wire at 0.50 metre belowground level for conductor earth electrode, includingconnection/ termination with GI thimble etc. as required. 142 Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing as required. 143 Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. 144 Fixing of lightning conductor finial (single prong) with base plateincluding holes etc. complete as required. 145 Jointing copper / G.I. tape (with another copper/ G I tape, baseof the finial or any other metallic object) by riveting / nutbolting/ sweating and soldering etc as required. 146 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For horizontal run) 147 Providing and laying G.I. tape 32 mm X 6 mm from earthelectrode directly in ground as required. 148 LT Cable Laying work 149 Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering andrefilling the trench etc as required. 150 Above 35 sq. mm and upto 95 sq. mm 151 Above 95 sq. mm and upto 185 sq. mm 152 Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizeon cable tray as required. 153 Upto 35 sq. mm (clamped with 1mm thick saddle) 154 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mmMS flat clamp) 155 Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. 156 3½ X 25 sq. mm (28mm) 157 3½ X 35 sq. mm (32mm) 158 3½ X 70 sq. mm (38mm) 159 3½ X 95 sq. mm (45mm) 160 3½ X 120 sq. mm (45mm) 161 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials forfollowing size of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade as required. 162 3½ X 25 sq. mm 163 3½ X 35 sq. mm 164 3½ X 70 sq. mm 165 3½ X 95 sq. mm 166 3½ X 120 sq. mm 167 Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required 168 50 mm dia 169 100 mm dia 170 150 mm dia 171 Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. 172 BLDC FAN 173 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 174 Add GST Factor @ 1.0633 for GST 18%, Then Total 175 Providing & Fixing iMEE 36 Watts Heavy Duty Polycarbonate 600 X 600 (2X2) Square LED Panel Light (Pack of 1, Cool Day Light) Recessed Ceiling Lamp (White) 176 Wooden screw 177 PVC slip 178 pvc Tape 179 Supply and installation of Wire Less Calling Bell complete work in all respect 180 Providing & Fixing motion sensor 36 Watts Heavy Duty Polycarbonate 600 X 600 (2X2) Square LED Panel Light (Pack of 1, Cool Day Light) Recessed Ceiling Lamp (White) 181 Supply and Installation of 20 watt LED Square Light complete work in all respect. 182 Flexible Pipe 25mm 183 Flexible pipe 50mm 184 Cable Tie 185 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 & 1/2 Core A2XFY 186 25.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 187 35.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 188 70.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 189 95.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 190 120.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 191 Supplying including fitting fixing of followingA.C. Wall fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. 192 Air Circulator wall fan 450 mm sweep Turbo force 193 Crisp Air with louver 250 mm sweep 194 Supplying including fitting fixing of followingA.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. 195 Swing platinawith plastic blade, 400 mm sweep 196 supply and Installation of 18 w LED Bulb in existing holder in complete work in all respect. 197 Supply and Installation of 18/20 watt LED tube light complete work inall respect. 198 Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split typeair conditioner of the following capacity with cordless remote complete with copper pipeand electrical connection cable,as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department.2 Ton 199 less gst

Key Value

Document Fees
INR 2360 /-
EMD
INR 67300.0 /-
Tender Value
INR 67.28 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail