Tender For Special Repair And Maintenance Work Of Electricity At Esic Hospital Chandrasekharpur, Repair Work Of Electrical Wiring For Staff Quarters Of Esis Hospital Chandrasekherpur, Bssr, 1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With , Kanpur-Uttar Pradesh

Government Departments has published Tender For Special Repair And Maintenance Work Of Electricity At Esic Hospital Chandrasekharpur, Repair Work Of Electrical Wiring For Staff Quarters Of Esis Hospital Chandrasekherpur, Bssr, 1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With . Submission Date for this Tender is 20-06-2024. Electrification Work Tenders in Kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43642043
Tender For Special Repair And Maintenance Work Of Electricity At Esic Hospital Chandrasekharpur, Repair Work Of Electrical Wiring For Staff Quarters Of Esis Hospital Chandrasekherpur, Bssr, 1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With
Open Tender
Indian
Uttar Pradesh
Kanpur
20-06-2024

Tender Details

Tender for special repair and maintenance work of electricity at ESIC Hospital Chandrasekharpur, Repair work of Electrical wiring for STAFF Quarters of ESIS Hospital Chandrasekherpur, BSSR, 1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 3 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 4 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 5 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 7 5/6 A switch 8 15/16 A switch 9 3 pin 5/6 A socket outlet 10 6 pin 15/16 A socket outlet 11 2 way 5/6 A switch 12 TV antenna socket outlet 13 Bell push 14 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 15 Single Pole 16 Double pole 17 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 18 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 19 1 or 2 Module (75mmX75mm) 20 3 Module (100mmX75mm) 21 8 Module (125mmX125mm) 22 12 Module (200mmX150mm) 23 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) 24 12 way, Double door 25 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 26 63 A 27 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 28 Supplying and fixing brass batten/ angle holder includingconnection etc. as required. 29 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 30 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 31 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 32 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 33 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 34 For GST 18% add Multiplying Factor @1.0633, Then Total 35 Applicable Cost Index of Khurda i.e 12.28% 36 Supplying with fitting and fixing Single Phase D.O.L Starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. Overload Relay Range 3.8 - 6.0 Amps for 2.2 KW 37 Supplying & erecting LED 20W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic drivercomplete 38 Supply and Installation of 12 watt LED Bulb complete work in all respect. 39 Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENTmake) 40 Repairs work of STP cum ETP Plant of 100 Bedded ESI Hospital CSPUR, Including all MEP devices including testing and commissioing work. 41 Repairs work of MGPL System Installed at 100 Bedded ESI Hospital CSPUR, Including all testing and commsionning work. 42 Supply and Installation Testing of 2X2 36W LED Panel Light complete work in all respect including dismantling of Old Fluorescent Tubelight. 43 Supply and Installation of Motion sensor 2x2 36W LED Panel Light at Corridor Area complete work in all Respect. 44 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/ Finolex make) . 45 3 Core A2XWY A2XFY 46 16.00 Sq.mm 3 Core armoured U.G. cable 47 70.00 Sq.mm.3 & 1/2 Core armoured U.G. cable 48 Supplying & erecting street light control panel in powder coat CRCA 14/16 SWG sheet, outdoor type, three phase, 415 V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 110 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of streetlights upto the max load of 12 kW on provided iron frame / CC foundation complete. 49 JUNCTION BOX 50 250x250x60 - 75 mm Depth 51 S u p p lying and erecting 250 kVAr, 3 phase, 50 Hz., capacitor dutycontactor with de-latching mechanism microprocessor APFCcontroller with MPP / APP type capacitor with 525 V and havingminimum overcurrent capacity of 1.8 In, peak inrush current capacity300 In and minimum life 150000 hours with , consisting of suitablesteps of MPP / APP type capacitor units with detuned aluminiumfilter 7% reactors with circuit breaker as main incomer and MCCB foreach branch protection, as per specification no CP-ED/APFC 52 S u p p l y i ng and erecting 150 kVAr, 3 phase, 50 Hz., capacitor dutycontactor with de-latching mechanism microprocessor APFCcontroller with MPP / APP type capacitor with 525 V and havingminimum overcurrent capacity of 1.8 In, peak inrush current capacity300 In and minimum life 150000 hours with , consisting of suitablesteps of MPP/APP type capacitor units with detuned aluminiumfilter 7% reactors with circuit breaker as main incomer and MCCB foreach branch protection, as per specification no CP-ED/APFC 53 Supplying, Fabrication, Erection , Testing commissioning of vermin and dustproof(IP-43 protection)totally enclosed cubical type compartmental floor mounting panel board of size 1700mm x 1000mm x 500mm made of 16 SWG(1.66mthick C.R. sheet and 300mm x 30mmx5mm MS Angle having4 nos legs at the bottom and C.R. sheet roofing on the top complete with 2 coats of Red Oxide metal primer and painting with powder coated paint. The panel board is to be erected in 1 :3:6 PCC foundation including excavation Complete neatly Wiring done, with the provision for the following Electrical Accessories. Provision for 400A 4Pole 50KA 415V MCCB with rotary handle INCOMING. Provision for 7 nos 4pole MCCB OUTGOING.0-500V Moving Iron Voltmeter (Digital), 0-400A Moving Iron Ammeter (Digital), Voltmeter S/S in 3 position , Ammeter S/S in 3 position , Indicator Lamp (R,Y, B), 2A Solid Lock Fuse , 400/5 C.T. Coil, Control Wiring, Incoming and Outgoing MCCB/MCB will be paid extra. 54 Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure)of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.100A 55 Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure)of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.400A 56 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 57 Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.25M X0.6MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of Enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation and brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 2nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 20mm X 3mm 4 strip copper Bus-Bar 0.5M length each, 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no, 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no, 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no, 5. Voltmeter & Ammeter Selector Switch- 2 no, 6. 2 A Slide fuse unit - 3nos, (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) 58 Erection of metallic pole of following length in cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refillingetc. as required. 59 Above 6.5 metre and upto 8.0 metre 60 Providing & erecting 6 m high (clear height) galvanised octagonalpole with foundation bolts having bottom of 130 mm A/F, top 70mm A/F on provided foundation as per specification no. OHPL/OPL 61 Supplying and erecting LED street light fitting suitable forabove 70W- 75 lamp, including lamp, with PF > 0.95 class IP 65and above housing of pressure die cast aluminium alloy and heatsink extruded aluminium complete per specification No FGODF/FLS2 62 Providing and erecting galvanised 1000mm single arm sword typebracket with FRP dome and ball as per specification no. OHPL/PBKT 63 Supplying, erecting, testing and commissioning of Microprocessorbased AMF panel suitable for diesel generating set of 1010 kVA capacity Single/Three phase, 230/415 Volts,50Hz A.C. with all standard features, safeties etc as per specificationno. GEN-AMF. 64 SITC of Changeover Panel or buscoupler of current rating upto 1600 A for changing of supply from mains to dg for 1010 KVA DG with appropriate rating of cable gland and lug complete work in all respect. 65 Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required. 66 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) 67 Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. 68 Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. 69 SITC of Air insulated Bus Duct from Transformer 1 to to the Main panel with rating upto 1600 A with all material lug gland nut bolt accessories complete work in all respect. 70 Overhaulic Repairing of LT Panel with changes of CT, PT items , Voltmeter, Ammeter, Breaker switch with all necessary items required at the time of repairing of panel complete work in all respect. 71 For GST 18% add Multiplying Factor @1.0633, Then Total

Key Value

Document Fees
INR 3916 /-
EMD
INR 165800.0 /-
Tender Value
INR 1.65 Crore /-