}

Tender For Price Schedule & Boq For Manpower For Operation At Various 400/200/132 Kv Sub-Stations Under Electricity Transmission Circle Muzaffarnagar- Against Short Term E-Tender No. Etc/Mu/T-04/2024-25 Of Etc Muzaffarnagar, 1 Manpower For Operation At , muzaffarnagar-Uttar Pradesh

Boards / Undertakings / PSU has published Tender For Price Schedule & Boq For Manpower For Operation At Various 400/200/132 Kv Sub-Stations Under Electricity Transmission Circle Muzaffarnagar- Against Short Term E-Tender No. Etc/Mu/T-04/2024-25 Of Etc Muzaffarnagar, 1 Manpower For Operation At . Submission Date for this Tender is 21-06-2024. Man Power Supply Tenders in muzaffarnagar Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43628758
Tender For Price Schedule & Boq For Manpower For Operation At Various 400/200/132 Kv Sub-Stations Under Electricity Transmission Circle Muzaffarnagar- Against Short Term E-Tender No. Etc/Mu/T-04/2024-25 Of Etc Muzaffarnagar, 1 Manpower For Operation At
Open Tender
Indian
Uttar Pradesh
Muzaffarnagar
21-06-2024

Tender Details

tender for Price Schedule & BOQ For Manpower for Operation at various 400/200/132 KV Sub-stations under Electricity Transmission Circle Muzaffarnagar- against Short Term E-Tender No. ETC/MU/T-04/2024-25 of ETC Muzaffarnagar, 1 Manpower for Operation at various 400/200/132 KV Sub-stations under Electricity Transmission Circle Muzaffarnagar- 2 Electricity 400 KV Sub-station Division, Muzaffarnagar 3 TG-II - 01 No. 4 Helper- 03 Nos. 5 Electricity Transmission Division, Muzaffarnagar 6 TG-II - 31 Nos. 7 Helper- 42 Nos. 8 Electricity Transmission Division, Shamli 9 TG-II - 24 Nos. 10 Helper- 44 Nos. 11 Electricity Transmission Division-I, Saharanpur 12 TG-II - 08 Nos. 13 Helper- 27 Nos. 14 Electricity Transmission Division-II, Saharanpur 15 TG-II -13 Nos. 16 Helper-22 Nos. 17 Manpower for Maintenanceat various 400/200/132 KV Sub-stations under Electricity Transmission Circle Muzaffarnagar- 18 Electricity 400 KV Sub-station Division, Muzaffarnagar 19 TG-II - 02 Nos. 20 Lineman/Fitter - 04 Nos. 21 Helper - 02 Nos. 22 Electricity Transmission Division, Muzaffarnagar 23 TG-II - 11 Nos. 24 Lineman/Fitter - 14 Nos. 25 Helper - 22 Nos. 26 Electricity Transmission Division, Shamli 27 TG-II - 11 Nos. 28 Lineman/Fitter - 12 Nos. 29 Helper - 21 Nos. 30 Electricity Transmission Division-I, Saharanpur 31 TG-II - 06 Nos. 32 Lineman/Fitter - 10 Nos. 33 Helper - 14 Nos. 34 Electricity Transmission Division-II, Saharanpur 35 TG-II - 06 Nos. 36 Lineman/Fitter - 06 Nos. 37 Helper - 12 Nos. 38 Regular cutting/ clearance of dense jungle and cutting of grass, shrubs and plants, including uprooting of all types of vegetation, bushes, etc. byscrapping of grass, bush wood & plants etc. above 2” over the ground level, weeding out the wild growth of roots, seeds etc. and collection of the foreign materials like kankar, pebbles, waste paper etc. along with uprooting of small wild trees by digging and taking out the complete root; in switchyard area, in the area between pale fencing & chain link fencing, area between pale/chain link fencing & security fencing & security wall including removal of all types of plants/creepers/shrubs on pale fencing and chain link fencing, area around control room/ committee room/ store sheds and open yard store area at the sub- station.After cutting, disposal of all the removed vegetation, rubbishand garbage etc. has to be done away from sub-station premises on Daily basis. Cutting/ uprooting of grass, shrubs, trees and creepers etc. has to be done on regular basis in such a way that height of grass is limited to less than 4” throughout the month in entire Switchyard. In case, any vegetation above the height of 4” from the ground is notattended within 04 days, the portion of that area shall be deemed to be incomplete for that month and shall not be measured.Following optional work may be allowed to be done by Contractor for controlling the wild Growth on no additional charges:Spraying of ‘Round Up/Glycel’ herbicide liquid and 39 Electricity 400 KV Sub-station Division, Muzaffarnagar 40 Total Area- 56500 Sq Meter. 41 Electricity Transmission Division, Muzaffarnagar 42 Total Area- 99465 Sq Meter. 43 Electricity Transmission Division, Shamli 44 Total Area- 114500 Sq Meter. 45 Electricity Transmission Division, Saharanpur 46 Total Area- 31000 Sq Meter. 47 Electricity Transmission Division-II, Saharanpur 48 Total Area- 56760 Sq Meter. 49 Maintenance of Lawn around Control Room Building Area & Flower Bed along main entrance road at 220 K.V. Sub Station Chinhat as per following detailed works with cost of men, materials, manure, pesticides and T&P etc. required to complete the job satisfactorily with the help of experienced gardener as per requirement / direction of Engineer Incharge : i)Maintenance of lawn grass including weeding out of all undersired growths, watering, trimming etc. using lawn movers or khurpi etc. has under in Col. (A) ii)Upkeep of flower bed approx. 1.0 meter wide by weeding out of all undersired growths, watering, trimming, tilling etc. time to time using khurpi etc. has under in Col. (B) iii) Upkeep of flower pots by wedding out of all undersired growths, watering, trimming, tilling etc. time to time using khurpi etc.Col. (C) 50 Electricity 400 KV Sub-station Division, Muzaffarnagar 51 Maintenance of Lawn Grass-2237 Sq Meter 52 Up Keeping of Flower Bed- 470 Sq Meter 53 Up Keeping of Flower Pot- 215 Nios. 54 Electricity TransmissionDivision, Muzaffarnagar 55 Maintenance of Lawn Grass-1967 Sq Meter 56 Up Keeping of Flower Bed- 517 Sq Meter 57 Up Keeping of Flower Pot- 352 Nos. 58 Electricity TransmissionDivision, Shamli 59 Maintenance of Lawn Grass-3200 Sq Meter 60 Up Keeping of Flower Bed- 365 Sq Meter 61 Up Keeping of Flower Pot- 365 Nos. 62 Electricity TransmissionDivision, Saharanpur 63 Maintenance of Lawn Grass-3299 Sq Meter 64 Up Keeping of Flower Bed- 520 Sq Meter 65 Up Keeping of Flower Pot- 520 Nos. 66 Electricity TransmissionDivision-II, Saharanpur 67 Maintenance of Lawn Grass-1130 Sq Meter 68 Up Keeping of Flower Bed- 220 Sq Meter 69 Up Keeping of Flower Pot- 220 Nos. 70 Following cleaning works are to be done at Transmsission Sub Stations - A) Daily Cleaning and Mopping of floors in Substation Control Room Building including following rooms: a)Control Room, b)Conference Room , c)Library, d)Pantry & Staff Room,e)T&C Room,f) Lobby Area,g)Battery Room, h) LT Room,i) Emulsifier Room , j) Compressor Room, k)Hydrant Room l) All Office Rooms etc.B) Daily Brooming at Roads inside and out side Switchyard. from switchyard, Parking area, Main entrance areaC) Toilet Cleaning - Daily cleaning of Toilets (Conference Room Washroom, Ladies Washroom, Common Washroom & Guards Washroom) with Phenyl / Harpic etc. (Common Washroom needs to be clean twice a day)D) Dusting & Cleaning with wet cloth & Phenyl/ DisinfectantLiquid along with cleaning and removing of dirt and spider web from Almirah, windows, doors, tables & chairs and ceiling and walls of all Office Rooms including Committee Room.In addition to the above work Collection of all type of garbage like Dry leaves, dirty clothes,plastic etc. from all over the campus area including cost of all men and material excluding Sundays. (One Job for each month) 71 Electricity 400 KV Sub-station Division, Muzaffarnagar 72 400 KV Sub-station Muzaffarnagar - 1 No. 73 Electricity Transmission Division Muzaffarnagar 74 220 KV - 03 Nos. 75 132 KV - 08 Nos. 76 Electricity Transmission Division Shamli 77 220 KV - 01 No. 78 132 KV - 10 Nos. 79 Electricity Transmission Division, Saharanpur 80 220 KV - 03 No. 81 132 KV - 04 Nos. 82 Electricity Transmission Division-II, Saharanpur 83 220 KV - 01 No. 84 132 KV - 05 Nos. 85 Work of maintenance/Refilling of different type fire extingusiher under the jurisdiction of Electricity Transmission Circle, Muzaffarnagar 86 Electricity 400 KV Sub-station Division, Muzaffarnagar 87 Mech. Foam 50 Ltr 88 Mech. Faom 9 Ltr 89 CO222KG 90 CO209KG 91 CO24.5KG 92 CO23KG 93 Electricity Transmission Division, Muzaffarnagar 94 Mech. Foam 50 Ltr 95 Mech. Faom 45 Ltr 96 Mech. Faom 9 Ltr 97 CO222KG 98 CO211KG 99 CO209KG 100 CO206KG 101 CO24.5KG 102 CO23KG 103 ABC Dry powder 5kg 104 Electricity Transmission Division, Shamli 105 Mech. Foam 50 Ltr 106 Mech. Faom 9 Ltr 107 CO222KG 108 CO211KG 109 CO209KG 110 CO206KG 111 CO24.5KG 112 CO23KG 113 ABC Dry powder 5kg 114 ABC Dry powder 10kg 115 Electricity Transmission Division, Saharanpur 116 Mech. Foam 50 Ltr 117 Mech. Faom 45 Ltr 118 Mech. Faom 9 Ltr 119 CO222KG 120 CO211KG 121 CO209KG 122 CO24.5KG 123 CO23KG 124 ABC Dry powder 5kg 125 ABC Dry powder 10kg 126 Electricity Transmission Division-II, Saharanpur 127 Mech. Foam 50 Ltr 128 Mech. Faom 9 Ltr 129 CO222KG 130 CO211KG 131 CO209KG 132 CO24.5KG 133 CO23KG 134 ABC Dry powder 5kg 135 ABC Dry powder 10kg 136 Regular Maintenance & Checkingof Emulsifier and Fire Hydrant Systems including Pre- summerMaintenanceatSubstationasperfollowingDetailwithallcostofMen,T&P, Consumables etc. For satisfactory completion of the work:Regular Maintenance & Operational Checking of Emulsifier & Hydrant Systems by carrying out following activities on a regular basis by providing skilled workman (01 No. for each SubStation)whoshallbereadilyavailableatalltimesandshallberesponsiblefor following works including additional manpower as needed: - 137 Electricity 400 KV Sub-station Division, Muzaffarnagar 138 Regular Maintenance & Operational Checking of EmulsifierSystem & Hydrant Systems(comprisingof electrical pump, diesel engine, jockey pump and associated pipelines and valves etc.) for T/Fs and Bus/Line Reactors as per standard practices:i.Dailycheckingofwaterleakagefrommainandauxiliarypipelines,valves,glands, sensorsandotherequipments.Anywaterleakageobservedshallbenotifiedtosite-in charge and attended within 24 hours.ii. Ensuring optimum level of water in water reservoir.iii. Ensuring priming of Main PumpJockey Pumpand Diesel Engineand ensuring proper level of water in priming tank at all times.iv. Observation of frequencyof operation of JockeyPumps and attending if any abnormalities are found.v. Ensuring smooth operation of Main Pumps, Diesel Engine, Jockey Pumps etc. ensuring their self-starting as per respective pressure-switch settings.vi. Regular maintenance of Diesel Engine Set including cleaning, checking and recording voltage and specificgravity of battery, attending any oil leakage, lubrication of all moving parts and checking and tightening of all terminal connections.vii.Weekly checking ofautomaticoperation ofEmulsifier Systemfor both electrical and dieselpumps.Healthinessofallautomationsystemsforsmoothoperationshallbe ensured.viii. Upkeep and maintenance of Battery Charger, and control panel of Diesel-Engine and refilling of diesel in diesel engine (Diesel to be provided by department).ix. Attending any breakdowns in- Control Panels, Indication Panels, Main Electrical Pump, Jockey Pump, headers, complete pipe line, Deluge Valves, piping ring-mains of transformers/reactorsandbattery sets-withallassociatedworkandreplacementofall kinds of valves, pressure switch, gaskets, pipes, quartz bulbs using spare to be provided by Department.Note: All the activities and works done shall be duly recorded by the workman in a register to be always kept at site. Failing to keep a record of any activity/work shall be deemed as non-completion of work for that month.(01 Job each for each S/S) 139 Onetimepre-summeroverhaulingandservicingofcompleteabovementionedemulsifier system andfirehydrant systems at Substation including following-i. Cleaning of all the pipelines, valves and water reservoir.ii. Replacement of all the gaskets and glands (to be provided by department) of all the valves and joints e.g. Foot Vales, Butter Fly Valves, Gate Valves.iii. Checking and replacement of all the defective valves, pressure switches, pressure gauges, electrical coils/switches/contactors, temperature sensors, spray nozzles. (All the items to be replaced shall be provided by the department).iv. Scrapping offofold paintand re-paintingofallthe pipelinesand connectingpipes from emulsifier room to each equipment (excluding ring-mains around transformers/ reactors) in theirrespectivecolours,byproperapplicationofone-coatofprimerandtwo-coatsofbest quality paint to be provided by the Agency.(01 Job each for each S/S) 140 Electricity Transmission Division, Muzaffarnagar 141 Regular Maintenance & Operational Checking of EmulsifierSystem & Hydrant Systems(comprisingof electrical pump, diesel engine, jockey pump and associated pipelines and valves etc.) for T/Fs and Bus/Line Reactors as per standard practices:i.Dailycheckingofwaterleakagefrommainandauxiliarypipelines,valves,glands, sensorsandotherequipments.Anywaterleakageobservedshallbenotifiedtosite-in charge and attended within 24 hours.ii. Ensuring optimum level of water in water reservoir.iii. Ensuring priming of Main PumpJockey Pumpand Diesel Engineand ensuring proper level of water in priming tank at all times.iv. Observation of frequencyof operation of JockeyPumps and attending if any abnormalities are found.v. Ensuring smooth operation of Main Pumps, Diesel Engine, Jockey Pumps etc. ensuring their self-starting as per respective pressure-switch settings.vi. Regular maintenance of Diesel Engine Set including cleaning, checking and recording voltage and specificgravity of battery, attending any oil leakage, lubrication of all moving parts and checking and tightening of all terminal connections.vii.Weekly checking ofautomaticoperation ofEmulsifier Systemfor both electrical and dieselpumps.Healthinessofallautomationsystemsforsmoothoperationshallbe ensured.viii. Upkeep and maintenance of Battery Charger, and control panel of Diesel-Engine and refilling of diesel in diesel engine (Diesel to be provided by department).ix. Attending any breakdowns in- Control Panels, Indication Panels, Main Electrical Pump, Jockey Pump, headers, complete pipe line, Deluge Valves, piping ring-mains of transformers/reactorsandbattery sets-withallassociatedworkandreplacementofall kinds of valves, pressure switch, gaskets, pipes, quartz bulbs using spare to be provided by Department.Note: All the activities and works done shall be duly recorded by the workman in a register to be always kept at site. Failing to keep a record of any activity/work shall be deemed as non-completion of work for that month.(01 Job each for each S/S) 142 Onetimepre-summeroverhaulingandservicingofcompleteabovementionedemulsifier system andfirehydrant systems at Substation including following-i. Cleaning of all the pipelines, valves and water reservoir.ii. Replacement of all the gaskets and glands (to be provided by department) of all the valves and joints e.g. Foot Vales, Butter Fly Valves, Gate Valves.iii. Checking and replacement of all the defective valves, pressure switches, pressure gauges, electrical coils/switches/contactors, temperature sensors, spray nozzles. (All the items to be replaced shall be provided by the department).iv. Scrapping offofold paintand re-paintingofallthe pipelinesand connectingpipes from emulsifier room to each equipment (excluding ring-mains around transformers/ reactors) in theirrespectivecolours,byproperapplicationofone-coatofprimerandtwo-coatsofbest quality paint to be provided by the Agency.(01 Job each for each S/S) 143 Electricity Transmission Division, Shamli 144 Regular Maintenance & Operational Checking of EmulsifierSystem & Hydrant Systems(comprisingof electrical pump, diesel engine, jockey pump and associated pipelines and valves etc.) for T/Fs and Bus/Line Reactors as per standard practices:i.Dailycheckingofwaterleakagefrommainandauxiliarypipelines,valves,glands, sensorsandotherequipments.Anywaterleakageobservedshallbenotifiedtosite-in charge and attended within 24 hours.ii. Ensuring optimum level of water in water reservoir.iii. Ensuring priming of Main PumpJockey Pumpand Diesel Engineand ensuring proper level of water in priming tank at all times.iv. Observation of frequencyof operation of JockeyPumps and attending if any abnormalities are found.v. Ensuring smooth operation of Main Pumps, Diesel Engine, Jockey Pumps etc. ensuring their self-starting as per respective pressure-switch settings.vi. Regular maintenance of Diesel Engine Set including cleaning, checking and recording voltage and specificgravity of battery, attending any oil leakage, lubrication of all moving parts and checking and tightening of all terminal connections.vii.Weekly checking ofautomaticoperation ofEmulsifier Systemfor both electrical and dieselpumps.Healthinessofallautomationsystemsforsmoothoperationshallbe ensured.viii. Upkeep and maintenance of Battery Charger, and control panel of Diesel-Engine and refilling of diesel in diesel engine (Diesel to be provided by department).ix. Attending any breakdowns in- Control Panels, Indication Panels, Main Electrical Pump, Jockey Pump, headers, complete pipe line, Deluge Valves, piping ring-mains of transformers/reactorsandbattery sets-withallassociatedworkandreplacementofall kinds of valves, pressure switch, gaskets, pipes, quartz bulbs using spare to be provided by Department.Note: All the activities and works done shall be duly recorded by the workman in a register to be always kept at site. Failing to keep a record of any activity/work shall be deemed as non-completion of work for that month.(01 Job each for each S/S) 145 Onetimepre-summeroverhaulingandservicingofcompleteabovementionedemulsifier system andfirehydrant systems at Substation including following-i. Cleaning of all the pipelines, valves and water reservoir.ii. Replacement of all the gaskets and glands (to be provided by department) of all the valves and joints e.g. Foot Vales, Butter Fly Valves, Gate Valves.iii. Checking and replacement of all the defective valves, pressure switches, pressure gauges, electrical coils/switches/contactors, temperature sensors, spray nozzles. (All the items to be replaced shall be provided by the department).iv. Scrapping offofold paintand re-paintingofallthe pipelinesand connectingpipes from emulsifier room to each equipment (excluding ring-mains around transformers/ reactors) in theirrespectivecolours,byproperapplicationofone-coatofprimerandtwo-coatsofbest quality paint to be provided by the Agency.(01 Job each for each S/S) 146 Electricity Transmission Division, Saharanpur 147 Regular Maintenance & Operational Checking of EmulsifierSystem & Hydrant Systems(comprisingof electrical pump, diesel engine, jockey pump and associated pipelines and valves etc.) for T/Fs and Bus/Line Reactors as per standard practices:i.Dailycheckingofwaterleakagefrommainandauxiliarypipelines,valves,glands, sensorsandotherequipments.Anywaterleakageobservedshallbenotifiedtosite-in charge and attended within 24 hours.ii. Ensuring optimum level of water in water reservoir.iii. Ensuring priming of Main PumpJockey Pumpand Diesel Engineand ensuring proper level of water in priming tank at all times.iv. Observation of frequencyof operation of JockeyPumps and attending if any abnormalities are found.v. Ensuring smooth operation of Main Pumps, Diesel Engine, Jockey Pumps etc. ensuring their self-starting as per respective pressure-switch settings.vi. Regular maintenance of Diesel Engine Set including cleaning, checking and recording voltage and specificgravity of battery, attending any oil leakage, lubrication of all moving parts and checking and tightening of all terminal connections.vii.Weekly checking ofautomaticoperation ofEmulsifier Systemfor both electrical and dieselpumps.Healthinessofallautomationsystemsforsmoothoperationshallbe ensured.viii. Upkeep and maintenance of Battery Charger, and control panel of Diesel-Engine and refilling of diesel in diesel engine (Diesel to be provided by department).ix. Attending any breakdowns in- Control Panels, Indication Panels, Main Electrical Pump, Jockey Pump, headers, complete pipe line, Deluge Valves, piping ring-mains of transformers/reactorsandbattery sets-withallassociatedworkandreplacementofall kinds of valves, pressure switch, gaskets, pipes, quartz bulbs using spare to be provided by Department.Note: All the activities and works done shall be duly recorded by the workman in a register to be always kept at site. Failing to keep a record of any activity/work shall be deemed as non-completion of work for that month.(01 Job each for each S/S) 148 Onetimepre-summeroverhaulingandservicingofcompleteabovementionedemulsifier system andfirehydrant systems at Substation including following-i. Cleaning of all the pipelines, valves and water reservoir.ii. Replacement of all the gaskets and glands (to be provided by department) of all the valves and joints e.g. Foot Vales, Butter Fly Valves, Gate Valves.iii. Checking and replacement of all the defective valves, pressure switches, pressure gauges, electrical coils/switches/contactors, temperature sensors, spray nozzles. (All the items to be replaced shall be provided by the department).iv. Scrapping offofold paintand re-paintingofallthe pipelinesand connectingpipes from emulsifier room to each equipment (excluding ring-mains around transformers/ reactors) in theirrespectivecolours,byproperapplicationofone-coatofprimerandtwo-coatsofbest quality paint to be provided by the Agency.(01 Job each for each S/S) 149 Electricity Transmission Division-II, Saharanpur 150 Regular Maintenance & Operational Checking of EmulsifierSystem & Hydrant Systems(comprisingof electrical pump, diesel engine, jockey pump and associated pipelines and valves etc.) for T/Fs and Bus/Line Reactors as per standard practices:i.Dailycheckingofwaterleakagefrommainandauxiliarypipelines,valves,glands, sensorsandotherequipments.Anywaterleakageobservedshallbenotifiedtosite-in charge and attended within 24 hours.ii. Ensuring optimum level of water in water reservoir.iii. Ensuring priming of Main PumpJockey Pumpand Diesel Engineand ensuring proper level of water in priming tank at all times.iv. Observation of frequencyof operation of JockeyPumps and attending if any abnormalities are found.v. Ensuring smooth operation of Main Pumps, Diesel Engine, Jockey Pumps etc. ensuring their self-starting as per respective pressure-switch settings.vi. Regular maintenance of Diesel Engine Set including cleaning, checking and recording voltage and specificgravity of battery, attending any oil leakage, lubrication of all moving parts and checking and tightening of all terminal connections.vii.Weekly checking ofautomaticoperation ofEmulsifier Systemfor both electrical and dieselpumps.Healthinessofallautomationsystemsforsmoothoperationshallbe ensured.viii. Upkeep and maintenance of Battery Charger, and control panel of Diesel-Engine and refilling of diesel in diesel engine (Diesel to be provided by department).ix. Attending any breakdowns in- Control Panels, Indication Panels, Main Electrical Pump, Jockey Pump, headers, complete pipe line, Deluge Valves, piping ring-mains of transformers/reactorsandbattery sets-withallassociatedworkandreplacementofall kinds of valves, pressure switch, gaskets, pipes, quartz bulbs using spare to be provided by Department.Note: All the activities and works done shall be duly recorded by the workman in a register to be always kept at site. Failing to keep a record of any activity/work shall be deemed as non-completion of work for that month.(01 Job each for each S/S) 151 Onetimepre-summeroverhaulingandservicingofcompleteabovementionedemulsifier system andfirehydrant systems at Substation including following-i. Cleaning of all the pipelines, valves and water reservoir.ii. Replacement of all the gaskets and glands (to be provided by department) of all the valves and joints e.g. Foot Vales, Butter Fly Valves, Gate Valves.iii. Checking and replacement of all the defective valves, pressure switches, pressure gauges, electrical coils/switches/contactors, temperature sensors, spray nozzles. (All the items to be replaced shall be provided by the department).iv. Scrapping offofold paintand re-paintingofallthe pipelinesand connectingpipes from emulsifier room to each equipment (excluding ring-mains around transformers/ reactors) in theirrespectivecolours,byproperapplicationofone-coatofprimerandtwo-coatsofbest quality paint to be provided by the Agency.(01 Job each for each S/S) 152 Maintenance and upkeepofDuctAir Conditioner system / Split-Window Air conditioners including repairing , Servicing & Overhauling along with all associated workrequired for satisfacotry round the clock running of AC Systemwith all cost of men , material,misc. consumables , T&P, cost of transportation for repairs as neededetc.including follwoing works as and when required(1 Job per month).a) Regular/Periodic Cleaning of filters , coolingcoils ,indoor / outdoor condensor fins including pressure cleaning by air/ water , brazing of coils, checking of copmpressor operation , replacementof fabric / polyfiber filter of indoor unit and general cleaning for satisfactory operation of the unitb) Topping up ofRefrigerant Gas.c) Complete filling of Refrigerant Gas after checking, attending leakage by necessary pre-testing , brazing , testing by pressuring with N2Gas including necessary dismantling and re-assemblingd) Replacement of Damaged Compressor by new one of same make. 153 Electricity 400 KV Sub-station Division, Muzaffarnagar 154 60 Ton- 02 Nos. (Duct Type) 155 Electricity Transmiision Division, Muzaffarnagar 156 5.5 Ton- 04 Nos. (Duct Type) 157 2 Ton- 44 Nos. (Split/Window Type) 158 1.5 Ton- 19 Nos. (Split/Window Type) 159 Electricity Transmiision Division, Shamli 160 5.5 Ton- 08 Nos. (Duct Type) 161 2 Ton- 51 Nos. (Split/Window Type) 162 Electricity Transmiision Division, Saharanpur 163 5.5 Ton- 2 Nos. (Duct Type) 164 3 Ton- 12 Nos. (Duct Type) 165 1.5 Ton- 41 Nos. (Split/Window Type) 166 Electricity Transmiision Division-II, Saharanpur 167 8.5 Ton- 2 Nos. (Duct Type) 168 5.5 Ton- 5 Nos. (Duct Type) 169 2 Ton- 14 Nos. (Split/Window Type) 170 Cleaning and maintenance of Cable Trenches in 400/220/132 KV Switchyard. The work includes lifting of Trench Covers (RCC/M.S Chequrred Plate type), removal of all the garbage, mud, sand and other foreign items toavoid blockages in monsoon season, washing of cable trenches with water jet, checking and repair of Cable Racks wherever necessary and placing and tightening all Control/Power Cables properly on the Cable Racks; as per cable trench specification of following sizes:- 171 Electricity 400 KV Sub-station Division, Muzaffarnagar 172 H-H type 300mm width, depth 0.30m to 0.50m approx. having 01 No. cable racks 173 Trench 1800mm width with 02 Nos. cable racks 174 Trench 1600mm width with 02 Nos. cable racks 175 Trench 1400mm width with 02 Nos. cable racks 176 Trench 1200mm width with 04 Nos. cable racks 177 Trench 1000mm width with 04 Nos. cable racks 178 Trench 910mm width with 04 Nos. cable racks 179 Trench 880mm width with 03 Nos. cable racks 180 Trench 870mm width with 04 Nos. cable racks 181 Trench 730mm width with 02 Nos. cable racks 182 Trench 640mm width with 02 Nos. cable racks 183 Trench 500mm width with 02 Nos. cable racks 184 Trench 450mm width with 01 No. cable racks 185 Trench 380mm width with 01 No. cable racks 186 Cleaning of chilling pits of ICTs and Reactors including removal of all the garbage, mud, sand and other foreign items toavoid blockages in monsoon season and washing of pits with water jet, as per following details: 187 Cleaning of chilling pit of 220 kv,160 MVA ICT 188 Cleaning of chilling pit of400 KV, 315 MVA ICT 189 Cleaning of chilling pit of400 KV, 500 MVA ICT 190 Cleaning of chilling pit of400 KV, 50 MVAR Reactor 191 Cleaning of chilling pit of400 KV, 63 MVAR Reactor 192 Electricity TransmissionDivision, Muzaffarnagar 193 X-X type 1800mm width, depth 1.5m to 2.5m approx. having 09 No. cable racks 194 B-Btype 1600mm width, depth 1m to 2.5m approx. having 05 No. cable racks 195 C-C type 1600mm width, depth 0.75m to 1.5m approx. having 03 No. cable racks 196 D-D type 1800mm width, depth 1.5m to 2.5m approx. having 03 No. cable racks 197 E-E type 750mm width, depth 0.75m to 1m approx. having 02 No. cable racks 198 F-F type 750mm width, depth 0.5m to 1m approx. having 01 No. cable racks 199 G-G Type 550mm width, depth 0.5m to 0.60m approx having 01 No. cable racks 200 H-H type 300mm width, depth 0.30m to 0.50m approx. having 01 No. cable racks 201 Cleaning of chilling pits of ICTs and Reactors including removal of all the garbage, mud, sand and other foreign items toavoid blockages in monsoon season and washing of pits with water jet, as per following details: 202 Cleaning of chilling pit of220 KV, 200 MVA ICT 203 Cleaning of chilling pit of 220 kv,160 MVA ICT 204 Electricity TransmissionDivision, Shamli 205 X-X type 1800mm width, depth 1.5m to 2.5m approx. having 09 No. cable racks 206 B-Btype 1600mm width, depth 1m to 2.5m approx. having 05 No. cable racks 207 C-C type 1600mm width, depth 0.75m to 1.5m approx. having 03 No. cable racks 208 E-E type 750mm width, depth 0.75m to 1m approx. having 02 No. cable racks 209 F-F type 750mm width, depth 0.5m to 1m approx. having 01 No. cable racks 210 G-G Type 550mm width, depth 0.5m to 0.60m approx having 01 No. cable racks 211 H-H type 300mm width, depth 0.30m to 0.50m approx. having 01 No. cable racks 212 Cleaning of chilling pits of ICTs and Reactors including removal of all the garbage, mud, sand and other foreign items toavoid blockages in monsoon season and washing of pits with water jet, as per following details: 213 Cleaning of chilling pit of220 KV, 200 MVA ICT 214 Electricity TransmissionDivision, Saharanpur 215 D-D type 1800mm width, depth 1.5m to 2.5m approx. having 03 No. cable racks 216 E-E type 750mm width, depth 0.75m to 1m approx. having 02 No. cable racks 217 F-F type 750mm width, depth 0.5m to 1m approx. having 01 No. cable racks 218 G-G Type 550mm width, depth 0.5m to 0.60m approx having 01 No. cable racks 219 H-H type 300mm width, depth 0.30m to 0.50m approx. having 01 No. cable racks 220 Cleaning of chilling pits of ICTs and Reactors including removal of all the garbage, mud, sand and other foreign items toavoid blockages in monsoon season and washing of pits with water jet, as per following details: 221 Cleaning of chilling pit of220 KV, 200 MVA ICT 222 Electricity TransmissionDivision-II, Saharanpur 223 C-C type 1600mm width, depth 0.75m to 1.5m approx. having 03 No. cable racks 224 E-E type 750mm width, depth 0.75m to 1m approx. having 02 No. cable racks 225 F-F type 750mm width, depth 0.5m to 1m approx. having 01 No. cable racks 226 G-G Type 550mm width, depth 0.5m to 0.60m approx having 01 No. cable racks 227 H-H type 300mm width, depth 0.30m to 0.50m approx. having 01 No. cable racks 228 200 mm width, depth 0.20m to 0.40m approx. having 01 No. cable RACKS. 229 Cleaning of chilling pits of ICTs and Reactors including removal of all the garbage, mud, sand and other foreign items toavoid blockages in monsoon season and washing of pits with water jet, as per following details: 230 Cleaning of chilling pit of220 KV, 200 MVA ICT 231 Cleaning of chilling pit of220 KV, 60 MVA ICT

Key Value

Document Fees
INR 2950 /-
EMD
INR 1920000.0 /-
Tender Value
INR 16.26 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail