}

Tender For Supply, Installation, Testing And Commissioning Of Dry Type Isolation Transformer, Surge Protection Panels And Allied Works For The Department Of Emmrc At Main Campus., Srinagar-Jammu And Kashmir

Boards / Undertakings / PSU has published Tender For Supply, Installation, Testing And Commissioning Of Dry Type Isolation Transformer, Surge Protection Panels And Allied Works For The Department Of Emmrc At Main Campus.. Submission Date for this Tender is 20-06-2024. Dry Cell Batteries Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43560455
Tender For Supply, Installation, Testing And Commissioning Of Dry Type Isolation Transformer, Surge Protection Panels And Allied Works For The Department Of Emmrc At Main Campus.
Open Tender
Indian
Jammu And Kashmir
Srinagar
20-06-2024

Tender Details

Supply, Installation, Testing And Commissioning Of Dry Type Isolation Transformer, Surge Protection Panels And Allied Works For The Department Of Emmrc At Main Campus. , Supply, Installation, Testing And Commissioning Ofsub Main Control L.T. Cubicle Type Totally Enclosedstandingtype (Stand Height Not Less Than 1Meter), Double Door, Dust, Damp And Vermin Prooflt. Danger Notice Plate, Connection Of Incoming And Outgoing Cables With Thimbles, Stove Enameled Painted And Having Following Incoming/ Outgoing Mccb , Meters, Indicators And Doublebus Bar Arrangements, Including Proper Cement Bottomingcomplete As Required. (Servo Input) A) 1No.320 Amp. 4Pole 36Kawith Built In Microprocessor Based Release Unit With Short Circuit, Over Currentprotection With Adjustable Setting & Adjustable Time Setting With Adjustable Setting As Per Standards With Terminals Suitable For Cable Connection On One Side And Bus Bar Connection On Other Side. Suitable To Receiveal./Cu. Armd Cables Size B) 1 Set 400Amp Busbar 4 Strip Heavy Duty Aluminum. C) 2 Set Surge Protection Device 1+2 Type Iimp 12.5Ka, Imax 50Ka . With Tp Mcb And Indicators. D) 0-500Volt Volt Meter . E) Phase Selector Switches. And Indicators The Contractor Will Have To Submit His Test Certificatesi.E (Hv Test 1.5Kv For 1 Minute ,Megger Test) Manufacturers Test Certificate Of Main Switchgears Panel Should Have Minimum Of 12 Months Of Warrenty Period Certificate And Free Service , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release Adjustable Type And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 200 A 4P 25 Ka Mccb (C/O Panel , Servo Supply) , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release Adjustable Type And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holesin Cubicle Panel, Making Connections, Etc. As Required. 160 A 4P 25 Ka Mccb (C/O Panel Direct Supply) , Supply, Installation, Testing And Commissioning Of Dry Type Isolation Transformer Totallly Enclosed 125 Kva, 415V/415V, 3Phase, Ratio 1:1, 50Hz Copper Wound, With Complete Body And System Construction As Per Standards. Of Automatc Electric Ltd / Bharti Egineers/ Electricfield Make , Supply, Installation, Testing And Commissioning Ofsub Main Control L.T. Cubicle Type Totally Enclosedwall Mounttype, Dust, Damp And Vermin Prooflt. Danger Notice Plate, Connection Of Incoming And Outgoing Cables With Thimbles, Stove Enameled Painted And Having Following Incoming/ Outgoing Mccb , Meters, Indicators And Doublebus Bar Arrangements Complete As Required. (Isolation Transformer Out) A) 1No.160 Amp. 4Pole 36Kawith Built In Microprocessor Based Release Unit With Short Circuit, Over Currentprotection With Adjustable Setting & Adjustable Time Setting With Adjustable Setting As Per Standards With Terminals Suitable For Cable Connection On One Side And Bus Bar Connection On Other Side. Suitable To Receiveal./Cu. Armd Cables Size B) 1 Set 250Amp Busbar 4 Strip Heavy Duty Aluminum. C) 1 No. 125 Amp. 4Pole 25Ka Mccbwith Built In Microprocessor Based Release Unit For Short Circuit, Over Currentprotection With Adjustable Setting & Adjustable Time Setting With Adjustable Setting As Per Standards With Terminals Suitable For Cable Connection On One Side And Bus Bar Connection On Other Side. Suitable To Receiveal./Cu. Armd Cables Size D) 2No. 100 Amp.4Pole 25Ka Mccbwith Built In Microprocessor Based Release Unit For Short Circuit, Over Currentprotection With Adjustable Setting & Adjustable Time Setting With Adjustable Setting As Per Standards With Terminals Suitable For Cable Connection On One Side And Bus Bar Connection On Other Side. Suitable To Receiveal./Cu. Armd Cables Size E)2No. 40 A , 10 Ka Curve Dp Rccb , 300Ma Ratting. F) 2 Set Surge Protection Device 1+2 Type Iimp 12.5Ka, Imax 50Ka . With Tp Mcb And Indicators. G) 0-500Volt Volt Meter . H) Phase Selector Switches. And Indicators I) Additional Space For 12 Mcbs The Contractor Will Have To Submit His Test Certificatesi.E (Hv Test 1.5Kv For 1 Minute ,Megger Test) Manufacturers Test Certificate Of Main Switchgears Panel Should Have Minimum Of 12 Months Of Warrenty Period Certificate And Free Service , Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc.As Required 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Supply, Installation, Testing And Commissioning Ofsub Main Control Lt Cubicle Type Totally Enclosedwall Mounttype, Dust, Damp And Vermin Proof M.V. Danger Notice Plate, Connection Of Incoming And Outgoing Cables With Thimbles, Stove Enameled Painted And Having Following Incoming/ Outgoing Mccb , Meters, Indicators And Doublebus Bar Arrangements Complete As Required. (Supply For Floor Panel) A) 1No. 160 Amp. 4Pole25ka Mccb Thermo Magnitic Adjustable. B) 1 Set 250Amp Busbar 4 Strip Heavy Duty Aluminum. C)3No. 125 A , 10 Ka Mccb 4 P.Thermo Magnitic Adjustable D) 0-500Volt Volt Meter E) Phase Selector Switches And Indicators F)1 Set Surge Protection Device 1+2 Type Iimp 12.5Ka, Imax 50Ka . With Tp Mcb And Indicators The Contractor Will Have To Submit His Test Certificatesi.E (Hv Test 1.5Kv For 1 Minute ,Megger Test) Manufacturers Test Certificate Of Main Switchgears Panel Should Have Minimum Of 12 Months Of Warrenty Period Certificate And Free Service , Supply, Laying ( Including All Fixing Arrangements) Of Isi Marked Aluminium Conductorxlpe Insulated Cable As Per Is 7098, Un Armoured, Served, Sheathed1100 Volts Grade. 150 Sqmm 3 1/2 Core , Supplying And Making End Terminationwith Brass Compression Glands Of Following Sizes Of 1.1. Kv Grade Multicore Aluminium Conductor Pvc Insulated And Pvc Sheathed , 3½ X 150 Sq. Mm (50Mm) , 3½ X 70 Sq. Mm (38Mm) , 2 X 16 Sq. Mm (22Mm) , Supply, Laying , Of Isi Marked Aluminium Conductorxlpe Insulated Cable As Per Is 7098, Armoured, Served, Sheathed1100 Volts Grade I/C Clamping As Required , 70 Sqmm 3.5 C (Tofloor Panles) , 16 Sqmm 2 C ( Ups Floor Board) , Wiring For Circuit (Raw Power)/ Submain Wiring Along With Earth Wire With The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed In Class Heavy Duty Pvc Conduit As Required . Note : Rates Of Suitable Pvc Conduitincluded In Above Description For The Follwing Items , 4 X 16 Sq.Mm + 2 X 16 Sq.Mm Earth Wire For Sub Main Wiring , 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earth Wire , 2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Cb/Rccb/Isolator) , 12 Way , Double Door , Supplying And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs (But Without Mcbs And Incomer ) As Required . 8 Way (4 + 24), Double Door , Supplying, Fixing, Testing And Commissioning Of Following Amperes Of Mccbswith Spreader Links 100 Amp 25Ka 4 Pole Auditorium) , Supplying And Fixing 6 A To 32 A Rating, 240/415 V, 10 Ka, “C”-Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Single Pole , Double Pole , Supplying And Fixing 40 - 63 A Rating, 240/415 V,“C”-Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. Double Pole , Supplying And Fixing Following Rating, Tpn, 415 V, Mcb 10Ka C Curve In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required 63 A , Supply Of Advance Maintenance Free Chemical Gel Earthing Of Dual Pipe Technology (Gi) Of 3 Mtrs Long 80 Mm Dia Of Outer Shell (Ms) With The 50 Mm Dia Of Inner Shell (Ms) Of 80-100 Microns Galvanized Chemrode Filled With Highly Conducting Metallic Compounds With The Permenant Sealings At Both The Ends With The Lead Terminal Of 50X10mm Size At The Top. The Electrode Shall Be Duly Tested And Certified By Cpri (Central Power Research Institute), Govt Of India For A Peak Short Circuit Withstanding Capacity Of 60 Ka. Including Supply/ Fixing Of Environment Friendly Rust Proof Heavy Duty Weather Proof Polyplastic Earth Pit Chamber. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , 25 Mm , Modifications And Set Righting (At Site) Of Existing Change Over Panel By Means Of Providing Of Solid Leads, Fixing Of Bus Bars , Changing Of Internal Connections Etc As Per Site Reqirements , Dismantaling Of Required Cables From Panels And Reconnectingof Same As Where Required As Per Site Requirements , Supply, Installation, Testing & Commissioning Of 5 Kva 1 Phase Inverter With 4X200ah 12Vtubuler Batteries Including Suitable Rack, Input/Output Leads/ Switch Sockets Etc. To Make The System Operational. Note: Item Should Have Minimum Of Two Years Warrenty And Free Service. , Providing And Fixingmodular Pvc Moduleboxwith 32 A Mcb And6 Pin 32 A Socket Outlet Combinetype Of Reputed Make/ As Per Approval (Inv I/P &O/P) , Supply, Installation, Testing & Commissioning Of Dp 63 A Power Scaners, Votage And Current Protections Single Phase Including Enclosure As Required. , Note. The Quoted Percentage (%Age) Should Preferably Be In Fractional Form In Order To Minimize Concurrence Of Similar Quoted Rates

Key Value

Document Fees
INR 600 /-
EMD
INR 30400.0 /-
Tender Value
INR 15.20 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail