Bids Are Invited For Custom Bid For Services - Annual Rate Contract For Overhauling Maintenance And Testing Of 132Kv Switch Yard Equipments At Bongaigaon Refinery Total Quantity :, Bongaigaon-Assam

Boards / Undertakings / PSU has published Bids Are Invited For Custom Bid For Services - Annual Rate Contract For Overhauling Maintenance And Testing Of 132Kv Switch Yard Equipments At Bongaigaon Refinery Total Quantity :. Submission Date for this Tender is 06-07-2024. Electrification Work Tenders in Bongaigaon Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43523365
Corrigendum : Bids Are Invited For Custom Bid For Services - Annual Rate Contract For Overhauling Maintenance And Testing Of 132Kv Switch Yard Equipments At Bongaigaon Refinery Total Quantity :
Open Tender
Indian
Assam
Bongaigaon
06-07-2024

Tender Details

Bids Are Invited For Custom Bid For Services - Annual Rate Contract For Overhauling Maintenance And Testing Of 132Kv Switch Yard Equipments - The scope of work includes overhauling & testing of isolators/breakers & earth switches as per the SOR. Vendor to ensure complete overhauling and servicing for smooth manual & electrical operation of the isolators, breakers & earth switch with all interlocks. The scope mentioned is indicative only and vendor shall ensure complete overhauling of the equipments. 2. Contractors Scope of Work for Isolators & breakers: 2.1 Overhauling, Testing of 132KV SF6 Breakers As per scope mentioned in service long text of item 10. 2.2 Overhauling, Testing of 132KV Earth Switch Isolators and LA As per scope mentioned in service long text of item 20. 2.3 Overhauling, Testing of 132KV CT As per scope mentioned in service long text of item 30. 2.4 Overhauling, Testing of 132KV PT As per scope mentioned in service long text of item 40. At Bongaigaon Refinery - Repairing, servicing, overhauling, greasing, alignment checking, of 132 KV CGL and SIEMENS MAKE Load Break SF6 Isolator with following spares: a) Replacement of Taper Roller Bearing (1Set 4 nos per pole) b) Replacement of Brass split pin, brass washer, nylon washer c) Replacement of necessary hardware, Alen cap screw. Spring washer, Nut bolts. d) Replacement of Limit Switch (2 nos. per pole) e) Replacement of Top Collar & Bottom Collar Repairing, servicing, overhauling, checking of 132 KV Breaker including: a) Alignment & adjustment of the operating lever & mechanism if required b) Checking.replacement of contactors. BMR, switches at local panel if required c) Checking the control circuit of the breaker& ensuring all interlocks are in line d) Troubleshooting mechanical & local/remote electrical operation of the breaker along with supply of push buttons or switches if required e)Gas leak test and rectification, gas supply shall be under the scope of vendor. f)Pr. switch checking and supply and replacement. g)Replacement of pole assembly if reqired pole sully shall be under the scope of IOCL F)Checking of breaker contact resistance. hjlf required internal inspection breaker degassed contact inspection would be arrange by the contractor in supervision of OEM OEM charges shall be paid seperatly as per SOR 1)During servicing geasing is to done at Ratchet wheel,pawls, bevel geras closing latch assembly,cam, rollers on main shaft lever, trip latch, trip trigger soller lever rooler two phase lever berpins etc. )During servicing ailing is to be done closing spring guide, trip coil moving core, closing coil and plunger, tripping spring shaft. Following works to be carried out during servicing, overhauling: a) Complete repairing, servicing, greasing, olling of 132 KV isolator & earth switch. b) Alignment checking. c) Mechanism, Cam checking & replacement of necessary parts, d) Dismantling to ground rod and replacing if required. e) Bearing replacement of the electrical motor. f) Checking of interlock, trouble shooting & necessary rectification for smooth operation of the isolator & earth switch both mechanically and electrically ice. operation from local and remote. h) Cleaning of Isolators, de-scaling of power contacts, applying Silicon jelly, lubricating of all rotating hinged points/joints with multipurpose grease/ oil as required i) IR value checking of line before starting the job and completion of the job. j) Maintenance of local control panel, terminal tightness, supply & replacing any miscellaneous components if required k) Troubleshooting and rectification of mechanical operation problems) Troubleshooting and rectification of electrical operation problems in both Local and remote modes including interlock checking myCleaning of Support Insulators and check for cracks in insulators, if any n)Checking and Alignment of Earthing Blades & Operation of Earth Switch o)Contact Resistance Measurement-(In Micro Ohm) of Isolators & Earth Switch Servicing of Lighting Arrestors p)Checking of Leakage by Current Analyser after cleaning the porcelain surface. (THRC measurement) q)Cleaning of LA Insulators riinsulation Resistance Measurement s)Testing by Surge Monitor kit-Counter and meter tests a) Complete checking, cleaning, oil level checking oil leak arrest & filling of all if required. b) Primary injection of CT. c) Replacement of CT if required, JOCL shall provide the CT. d) Measuring & recording IR value of CT before & after maintenance. e) Aressting of Oil leakage, IOCL shall provide the oil fiTesting of CT sample oil. e)Checking of Eathing connections. f)Checking bellow position. g)Cleaning of porcelain isulator. h) Tightness of primary secondary wires a) Complete checking, cleaning, oil level checking arresting of oil & filing of oil if required. b) Primary injection of PT. c) Replacement of PT if required, IOCL shall provide the PT. d) Measuring & recording IR value of CT before & after maintenance. e) Aressting of Oil leakage, IOCL shall provide the oil fiTesting of PT sample oil. e)Checking of Eathing connections. f)Checking bellow position. g)Cleaning of porcelain isulator. h)Tightness of primary secondary wires Arrangement of OEM visit for SF6 breakers, CT, PT.Fooding, boarding and lodging, to and fro travel of engineer and any arrangement of special tools and tackles like SF6 leakage detection kit and filling kit shall be done by the agency. The job shall be done as per direction of the EIC. Charges for OT hours for Engineer The job to be executed as technical specification of the attached of Mis Power Grid Corporation of India Limited, Dosument no C/ENGG/SPEC/GTR(Rev. 14), point no 22.9 and the technical details of the RTV coating attached in the document (annexure-H). Bidder to execute one sample testing of the RTV coated insulator at at NABL accredited laboratory and provide the result to IOCL No Seperate charges shall be paid by 1OCL for the testing purpose. CARRYING OUT TAN DELTA TESTING OF CT PT OIL FILLED BUSHING TRAN LA ETC AS PER EIC INSTRUCTION KIT SHALL BE ARRANGED BY CONTRACTOR Supply of 11 kv antifog disc insulators along with 11 kV hardware fittings (B&S type) as per IS:731-1971, having creepage distance of atleast 432mm, electromechanical strength of 120kN. The socket portion confirming to IS: 2486 (part-ll) for 20mm and forged steel ball pin confirming to IS: 2486 (part- II) for 20mm. Test report of the insulator shall be provided to EIC by the agency. The insulator make and specification shall be approved by EIC. Supply of auxillary switches/contactors inclusive but not limited to the list below or its equivalent: Kaycee 15260, 6A, 440V,50Hz Kaycee 15160, 6A, 440V,50Hz Kaycee 25460, 6A, 440V,50Hz Каусане 252680, 6A, 440V,50Hz Kaycee 25460, ĐA, 440V,50Hz Yule PAK-GUS 44W Yule PAK-GUS 71W Siemens 3TA67 01-0A Aux, breaker switch SNO+5NC 14NO+14NC Supply of Siemens or EQ different Contactors 220V DC for CGL and SIEMENS make SF6 breakers. Supply of solenoid for trip and closing coil, Supply of bimetallic Relay including but not limited to: Siemens 3UA19 2, 0.8 to 1.2 A or its equivalent Siemens 3UA19 2, 3.5 to 5A or its equivalent antipumping relay 1NO+INC supply of ACSR Moose conductor of approved make and standard IS 398-5 (1992) as directed by EIC, VOLTAGE TRANSFORMER, 132KV/110V, OUTDOOR Outdoor, Oil cooled Single Phase, Single Pole, Dead Tank, OIP Insulated Earthed Type Voltage Transformer to 15:3156/1992 Ratio 132000//3/110/V3/110/V3/110/V3/110/V3 V V HSV: 145 KV insulation level 230 kV/550 kVp. (Ratio change by means of tap on secondary winding) Sec 1:50 VA, Class 0.2. Sec 2: 200 VA, Class 0.2. Sec3: 50 VA, Class 0.2 Sec4: 50 VA, Class 3P. VF: 1.2 Cont & 1.5 for 30 sec. Creepage Distance: 25 mm/kV HSV. Freq: 50 Hz Insulation Class: A This item should be identical to the existing VT in 132kV Switchyard having same dimensions, ratings Existing VT make is CGL. Material will not be accepted if there is any mismatch in ratings ordimensions with existing item. GA drawings, Factory best reports and data sheets are to be providedalong with the material delivery. HSV: 145 KV : 145/275/650 kVp Short Time Current Rating 31.5 kA/1 Sec. Creepage Distance: 25 mm/kV. Freq: 50 Hz Insulation Class: A Core:1 Accuracy class 0.2 CT.Ratio: 75-10-200/1, CT burden 30VA ISF <=5 Core1 2 Accuracy class SP CT Ratio: 75-10-200/1, CT burden 15 VA ALF 10 Core3: CT.Ratio: 75-10-200/1. Accuracy class PS Knee Point VOLTAGE 250-300-600V I exc mA 30@VK/2 Rct @75 °C(OHM) 1-1.5-3 Core:4 CT.Ratio: 75-10-200/1. Accuracy dass PS Knee Point VOLTAGE:250-300-600V I exc mA 30@ VK/2 Rct @75 °C(OHM) 1-1.5-3 This item should be identical to the existing 132kV CT in 132kV Switchyard in all dimensions, ratings and electrically. Material will not be accepted if there is any mismatch in ratings or dimensions with existing item. Existing CT make is CGL GA drawings, Factory test reports and data sheets are to be provided along with the material delivery. ERECTION OF PANEL/MOTOR/EQUIPMENT Erection, testing and commissioning of panel, motor and any other equipment on existing foundation including carriage from Stores to the site, unpacking, placing on foundation, levelling, fixing and fitting of all components, making necessary connections, phase checking, meggering as necessary all complete with labour and materials as per the direction of Engineer-in-charge. Small equipment requiring tractor trailer but not requiring crane/hydra etc. (beyond 100 kg) Equipment, Panels, motor etc. weighing above 500 kg and requiring hydra and tractor trolley etc but <3MT. Unit of measurement is to be considered as EACH (EA) in place of TONNE (TO) till the next revision of M&I SOR DISMANTLING OF POWER DISTRIBUTION EQUIPMENTS Dismantling of following power distribution equipments without any damage to it and returning it to our stores or reinstallation of same at a place within a lead of 3 KM (reinstallation charges not includes) all complete with labour and materials as per the direction of the EIC Small equipment requiring tractor trailer but not requiring crane/ hydra etc. (beyond 100 kg.), Equipment weighing above 500 kg and requiring hydra and tractor trolley etc. ERECTION OF ACSR CONDUCTOR Erection of ACSR conductor of following sizes diameter including binding etc. as required., 7/3.35 mm diameter and above PF ESI Reimbursement of PF & ESI shall be done as per government norms and as per actual on submission of documentary proof. Total Quantity :

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-06-2024 25-06-2024
2 26-06-2024 06-07-2024

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 45.30 Lakhs /-