Bids Are Invited For Custom Bid For Services - Procurement Of F&G System (Fire & Gas System)- F&G System For Rupkhelia Compressor Station, Project Shall Be Supplied As Per Scope Of Work, Specification, Control System Schematic, I/O List And Cables Sched, Duliajan-Assam

Department Of Industries And Commerce has published Bids Are Invited For Custom Bid For Services - Procurement Of F&G System (Fire & Gas System)- F&G System For Rupkhelia Compressor Station, Project Shall Be Supplied As Per Scope Of Work, Specification, Control System Schematic, I/O List And Cables Sched. Submission Date for this Tender is 13-07-2024. Safes Tenders in Duliajan Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43514019
Corrigendum : Bids Are Invited For Custom Bid For Services - Procurement Of F&G System (Fire & Gas System)- F&G System For Rupkhelia Compressor Station, Project Shall Be Supplied As Per Scope Of Work, Specification, Control System Schematic, I/O List And Cables Sched
Open Tender
Indian
Assam
Duliajan
13-07-2024

Tender Details

Bids Are Invited For Custom Bid For Services - PROCUREMENT OF F&G SYSTEM (fire & gas system)- F&G system for Rupkhelia Compressor Station, Project shall be supplied as per scope of work, specification, Control system schematic, I/O List and cables schedule attached with this requisition. F&G System supplied shall be complete in all respect for safe operational requirements and shall consists of the following: 1. Hardware –PLC Based F&G Panel SIL-3 rated shall consist of 24 Channel Gas Detection System. F&G Panel shall have provision for connecting Gas Detectors, MCP, Hooter, and beacon. F&G system shall have provision for programmable gas detector channel and relay card/ module to configure field devices. F&G system facilitate with serial or Modbus communication port to interface with station/ terminal RTU located at Rupkhelia – 01 no. PLC Based F&G Panel of 24 channel and this channel shall be universally configurable type for connecting all type Gas Detectors, MCP, Hooter & Beacon field devices. PLC Based F&G Panel shall be installed in Control Room. Necessary Graphics and displays (Alarms, Diagnostic, and Trends etc.) shall be developed in the New F&G system under the supervision of existing F&G contractor for this pipeline project. Also, necessary hardware and software required for integration & extension of the same shall be in vendor scope. I. F&G system shall interface with proposed new RTU at terminals through secure and redundant communication link; II. Testing – FAT / SAT, Installation, commissioning and training; III. Supply of erection & commissioning spares; 2. Point Type Gas Detectors – IR Type – for detection of Natural Gas in Process Area 3. Open Path Gas Detectors – UV/IR Type in Process Area 4. Beacon – Amber Colour – for visual indication of flammable gas leak alarm in process areas 5. Outdoor Hooter– Dual Tone Type for installation in Process 6. Manual Call Point for installation in Process Area 7. 1T x 1.5 Sq. mm, Fire resistant, Over all Screened 8. 8T x 1.5 Sq. mm, Fire resistant, Individual Screened and Over all Screened 9. 1P x 1.5 Sq. mm, Fire resistant, Over all Screened 10. 12P x 1.5 Sq. mm, Fire resistant, Individual Screened and Over all Screened 11. Analog F&G Junction Box, Explosion Proof Exd, Suitable for Hazardous Area Classification Zone I, Gas Gr IIA/IIB, T3. 12. Digital F&G Junction Box, Explosion Proof Exd, Suitable for Hazardous Area Classification Zone I, Gas Gr IIA/IIB, T3. 13. Explosion Proof Cable Glands, Plugs and erection hardware as required CONTROL BUILDING - 14. 2. Fire Alarm Control Panel (FACP): Design, detailed, engineering, supply, configuration, testing, installation, erection and commissioning of 8 loop, Addressable, Intelligent Fire Detection and Alarm Panel for automatic fire detection & communication of alarms for various types of detectors installed like multi sensor, loop isolators, manual call points, hooters, beacon etc. installed in respective control room with supporting multiple communication protocol. FACP shall be installed in suitable location inside control building Rupkhelia. 01 No. FACP Supply, laying of cables (all types required from Field devices to FACP and inside Control Room) inside Control room (Portacabin and control room) between detectors, MCP, hooter and FACP including glanding, termination, ferruling, dressing etc. at both ends. Supply & installation of cable trays (if necessary), supply of erection materials, cable ferrules, cable lugs, and cable tie etc. for successful commissioning of FACP. I. FACP shall interface with RTU & Fire Suppression System through secure and redundant communication link and hardwired; II. Supply of erection & commissioning spares; III. Testing – FAT / SAT, Installation, commissioning and training. 15. Addressable multi sensor (Smoke + Heat) – for installation in terminal control room (Portacabin and control room); 45 nos. 16. Indoor Hooter– Dual Tone Type for installation inside the control building and Portacabin; 02 nos. 17. Manual Call Point for installation inside the control building and Portacabin. 02 nos. 18. Beacon – Amber Colour – for visual indication of flammable gas leak alarm inside the control building and Portacabin 2nos. Total Quantity :

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-07-2024 13-07-2024
2 21-06-2024 28-06-2024
3 27-06-2024 05-07-2024

Key Value

Document Fees
Refer document
EMD
INR 250000.0 /-
Tender Value
Refer document