Tender For Colonovideoscope, Mumbai-Maharashtra

Tata Memorial Center has published Tender For Colonovideoscope. Submission Date for this Tender is 05-06-2024. Medical Equipment Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43412898
Tender For Colonovideoscope
Single
Indian
Maharashtra
Mumbai
05-06-2024

Tender Details

Tender For Colonovideoscope; Model Name: CF-EZ1500DL Make: OLYMPUS Year of Introduction: Year of probable end of support: A Colonovideoscope-1Nos 1 Should have extended Depth of Field (EDOF) technology combines images captured in near view with those taken in far view to generate an image with a wider depth of field, assuring superior observation with continuous wide focus. 2 Should have high magnification up to 1.5 mm with the ease of Dual Focus. 3 Should have high magnification of 100x or better without reduction in field of view at this magnification. 4 Should be compatible with (TXI) Texture and Color Enhancement Imaging, (RDI) Red Dichromatic Imaging and NBI. 5 Should have responsive insertion technology inculcating high force transmission, passive bending and variable stiffness. 6 Should be compatible with Scope Guide – A technology providing real time colonoscope configuration. 7 Should have High-Definition image Quality. 9 Should have waterproof One-touch connector which is fully immersible in disinfectant solution. 10 Should have Auxiliary channel for water jet function 11 Should have Five remote control switches on control body. 12 Should have Pre-freeze function for sharper images 14 Compatible with leakage testing device with its air flow and pressure regulation through light source’s air pump. 15 Field of view should be 170 degree in normal focus & 160 degree or more in near focus 16 Direction of view should be forward viewing, 0 degree 17 Depth of field should be Normal- 3-100 mm, Near 1.5 - 5.5 mm 18 Distal end outer diameter should be 13.2 mm 19 Insertion tube outer diameter should be 12.8 mm 20 Angulation should be 180 degree for Up-Down and 160 degree for Right -Left 21 Instrument channel diameter should be 3.7mm 22 Minimum visible distance should be 4 mm (Normal) from the distal end 23 Total length should not be more than 1700 mm 24 Should be supplied with all the standard accessories such as channel cleaning brush, injection tube, air water channel cleaning adaptor , suction cleaning adaptor, biopsy valve, biopsy forceps, auxillary water tube, etc 25 Should be compatible with Processor CV1500 B Checklist Points : 1 Should perform yearly calibration/validation and preventive maintenance (2nos) during warranty & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, consumable spares,breakdown calls) Testing & measuring equipment used should be traceable to SI units through National/international standards (As per NABH norms). To submit SOPs for PMS at the time of installation/commissioning. 2 Please submit the technical data sheet along with the brochure as a tender document with reference to the quoted make & model. 3 Please specify list of consumables/consumable Spares (i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly such as annual maintenance kit etc.) if any. 4 Please specify pre installation requirements [electrical, HVAC. 5 Please specify footprint size & weight. 6 Demo of the quoted model, will be required if so desired by the user, after the opening of the technical bid within ten days and prior to opening of financial bid. This is for technical evaluation. 7 Predispatch inspection at factory will be required if desired by authorities. 8 Should be CE/FDA/BIS/ICMED approved 9 Please specify power consumption. 10 Unpacking and shifting the consignment to the installation site is to be included in the scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installtion site. Unloading site shall be Stores department, Main Building Basement,TMH. If needed ,bidder has to arrange for the laboures at no charge to TMH.(Before submitting the quotation,bidders may visist TMH to Know unloading and installation site. C Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. D Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email. E Warranty- 2 years F 2 years warranty & 8 years CMC should be inclusive of free repairs for all manufacturing defects & all accidental damages. This should include free labour cost and free spare replacement. G CMC- For 8 years after warranty. Include 4 preventive maintenance/ year and all breakdown visits. All bought out items used in system should also be included in the warranty & CMC. Warranty & CMC should include upgrades and update cost, No separate software licence fees will be payable. H Loaner should be provided during Warranty and CMC. I Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted. J Buyback offer to be given Make:Olympus Model: CF-H180AL

Key Value

Document Fees
Refer document
EMD
INR 88600.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail