| 1 | Preventing maintenance /Servicing of both the indoor/outdoor units of Towertype A/C 4.0TR capacity of any make by cleaning of cooling and condenser coil of indoor & outdoor unit, cleaning filters removing internal dust by using vacuum cleaners, oiling, greasing wherever required, checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc in if necessary replacement of existingsize magnetic contactor, relay over load protector, relay, thermostat and internal wirringand service complete all as specified and directed.Note : (i) Fixing of spares parts such as Compressor, starting capacitor, running capacitor, fan motor, blower motor, copper tubes, PVC pipes etc. if found defective will be measured and paid separately as supply only.(ii) Charging of gas if required will be paid separately as supply only. |
| 2 | All as per item No. 1 above but for 1.5/2.0 TR capacity of spilt/window type AC. |
| 3 | Supply only fins and tube type air cooled condenser suitable for any make split type AC of cap of 1.5/ 2 TR complete all as specified and directed. |
| 4 | Supply only new fan motor for outside condenser unit of split AC of capacity 1.5/ 2 TR/ 54 Watt, 220 V or existing size and testing complete all as specified and directed.Make- American Universal/Khaitan / Usha or equivalent |
| 5 | Supply only blower fan motor of spilt type AC 1.5/2 Ton capacity and testing complete all as specified and directed.Make- American Universal/Khaitan / Usha/ LG/Blue star/Voltas/Hitachi or equivalent |
| 6 | Supply only double shaft of 1/5, 1/7 HP fan motor of window type AC 1.5/2 Ton capacity and testing complete all as specified and directed.Make- American Universal/Khaitan / Usha/ LG/Blue star/Voltas/Hitachi or equivalent |
| 7 | Supply only copper refrigerant pipe one run1/4/1/2 Inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as specified and directed.Note One Run of 1/4 inches dia pipe with insulation will be measured as one RM. |
| 8 | Supply only copper refrigerant pipe one run 5/8 inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as specified and directed.Note:- One Run of 5/8 inches dia pipe with insulation will be measured as one RM. |
| 9 | Supply only copper/brass valve1/4/1/2inches dia, inculding suitable size of pipe, with cap, dead nuts etc for fixing ofsuction line/delivery spilt type AC outdoor unit complete all as specified and directed. |
| 10 | Supply only copper/brass valve5/8 inches dia, inculding suitable size of pipe, with cap, dead nuts for fixing ofsuction line/delivery spilt type AC outdoor unit complete all as specified and directed. |
| 11 | Supply only PVC drain water pipe dia heavy duty transparent flexible for drainage water system of split AC complete with clamp fitting and drilling all as per ground requirement complete all as specified and directed. |
| 12 | Supply only complete indoor/out door PCB of spilt type AC/window type AC of Cap 1.5TR/2 TR with remote assembly with suitable battery for any type & make of Split/window AC complete all as specified and directed. |
| 13 | Supply only complete indoor /out dooor PCB of invertor type spilt type AC/window type AC of Cap 1.5TR/2 TR with remote assembly with suitable battery for any type & make of Split/window AC complete all as specified and directed. |
| 14 | Supply only running oil capacitor combined of Cap 50/6, 55/4, 60/4, suitable for 1.5 TR/2 TR split/ window AC at site and making connection using PVC insulated copper wire and thimbles complete all as specified and directed.Make-Tesla/Asian/ Keltron/Sarada/Unistar. |
| 15 | Supply only starting dry capacitor combined ofCap 80/100, 100/120 MFD suitable for 1.5 TR/2 TR split/ window AC at site and making connection using PVC insulated copper wire and thimbles complete all as specified and directed.Make-Tesla/Asian/ Keltron/Sarada/Unistar. |
| 16 | Supply only and taking out unserviceable compressor sealed unit of 1.5 TR capacity, reciprocating/Rotary from the spilt type AC (Make : LG/Blue star/Voltas/Hitachi etc.) single phase 230 volts and replacing the same with new compressor sealed unit fixing and vacuumization pressure testing leakage rectification and charging refrigerant gas and testing complete all as specified and directed.Note :- Compressor supplied shall be of same make as of existing make. |
| 17 | All as per item No. 16 above but for 2.0 TR capacity. |
| 18 | All as per item No. 16 above but for 1.5TR/2.0 TR capacity of Window type. |
| 19 | Supply only spilt type indoor unit complete of existing cap/make including removing and refixing the same place complete all as specified and directed. |
| 20 | Supply only in replacement of existing cap/make/type spilt type outdoor unit body complete including heating coil, Motor, compressor with Gas of existing cap/make complete all as specified and directed |
| 21 | Taking down 1.5/2.0 ton capacity split type AC complete with indoor unit, outdoor unit and refrigerant pipe and re-fixing the same in other room of same building or another building including testing and commissioning detailed as under :-(a) Cooling unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water including fixing of interconnection pipe all as directed. (b) Erection of condenser, compressor unit on outside of the building, fixed over suitable size of clamp/bracket.(Old clamp/bracket retrieved from demolition shall be reused in case old clamp/bracket found serviceable) (c) All civil work as plastering, cementing, whitewashing, filling of existing hole etc.required to be done as per site requirement at both the places(from where taken down and at place of re-fixing)NOTE:-(i) Charging / toping up gas if required will be measured & paid separately as supply only. (ii) Additional length of copper tubing if required will be measured & paid separately. |
| 22 | Taking down 1.5/2.0 ton capacity Window type AC complete and refixing the same in other room of same building or another building including testing and commissioning detailed as under :-(a)All required requisite work such as cutting/drilling/fixing shall be part of the Job in quoted rate.NOTE:- (i) Charging / toping up gas if required will be measured & paid separately as supply only. |
| 23 | S&F water proof ply wood 4 mm thick commercial type including cutting, drilling and making good the disturbed surface complete all as specified and directed. |
| 24 | Supply only metal clamp /bracket for outdoor unit of split type AC 1.5/2.0 ton capacity complete all as specified and directed. |
| 25 | S&F in repairs foam armor of size 5/8\" for copper refrigerant pipe of AC complete all as specified and directed. |
| 26 | S&F in repairs foam armor of size 1/4\" for copper refrigerant pipe of AC complete all as specified and directed. |
| 27 | Supply only complete Remote of spilt type AC/window type AC of Cap 1.5TR/2 TR with remote assembly with suitable battery for any type & make of Split/window AC complete all as specified and directed. |
| 28 | M&L for pressure testing of split type AC 1.5/2.0 Ton capacity and rectifying the leakage of refrigerant gas in the system, including vacuuming and charging only gas, replacing the capillary tube and copper liquid filterincluding testing and commissioning complete all as specified and directed.NOTE- Supply only gas will be measured & paid separately. |
| 29 | Preventing maintenance/Servicing of Refrigerator of any capacity and make by cleaning of cooling and condenser coil ofchecking of refrigerant pressure, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as specified and directed including if necessary replacement of minor spare parts i.e thermostate, relays , capactor, contractor etc.Note : (i) Fixing of spares parts such as Compressor, etc if found defective will be measured and paid separately as supply only.(ii) Charging of gas if required will be paid separately as supply only. |
| 30 | Taking out unserviceable compressor sealed unit of refrigerator(make-Whirlpool/Kelvinator/Genius Supreme/LG/Samsung etc) 165 to 210 litres capacity, single phase 230 volts and replacing the same with new compressor sealed unit Fixing & connecting the same including vacuumization, pressure testing leakage rectification and supply charging refrigerant gas and testing complete all as specified and directed. |
| 31 | M&L for taking out unserviceable compressor sealed unit of refrigerator(make-Whirlpool/Kelvinator/Genius Supreme/LG/Samsung etc) 280 to 330 litres capacity, single phase 230 volts and replacing the same with new compressor sealed unit Fixing & connecting the same including vacumization, pressure testing leakage rectification and supply charging refrigerant gas and testing complete all as specified and directed.Note for item No. 29 & 30:- Compressor supplied shall be of same make as of existing make. |
| 32 | Preventing maintenance/Servicing of Deep Freezer of anycapacity and make by cleaning of cooling and condenser coil ofchecking of refrigerant pressure, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed ncluding if necessary replacement of mior spare parts i.e thermostate, relays , capactor etc complete all as specified and directed. |
| 33 | Preventing maintenance/Servicing of Water cooler of anycapacity and make by cleaning of cooling and condenser coil ofchecking of refrigerant pressure, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as specified and directedincluding if necessary replacement of mior spare parts i.e thermostate, relays , capactormotor condenser coil etc .Note for(i) Fixing of spares parts such as Compressor, if found defection will be measured and paid separately as supply only.(ii) Charging of gas if required will be paid separately as supply only. |
| 34 | Taking out unserviceable compressor sealed unit of water cooler (Make-Shriram/ Usha/ Blue star) of capacity 40/80/150 liter capacity, single phase 230 volts, & replacing the same with new compressor sealed unit fixing & connecting the same including vacuumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete all as specified and directed.NOTE- Compressor supplied shall be of same make as of existing make. |
| 35 | Suuply onlygas charging the systemwith correct quantity ofR-32/R-22/R-410/R-407/R-134 gas for split/window type A/C of 1.5 TR/2 TR/3 TR/4 TRcapacity/Refrigerator/Deepfreezer/Water cooler and repairing the leakage in tube /lines by brazing and charging the unit with compressor oil charging replacing the capillary tube and copper liquid filter completeincluding fixing the same in position and testing and commissioning complete all as specified and directed.Note : contractor should be gas deposit the MES store with Gas cylinder. |
| 36 | Repair/Maintenance/Over all servicing of desert cooler including all fitting and fixtures, if required replacement of grass pad set of any size of desert cooler to cover the entire area (one desert cooler consist three grass pad), PVC pipe and distribution cap, with replacement of internal wiring of Cap CC X2.5 Sqmm copper cable, PVC connecting, existing size of clamp, nut bolts, including welding, grinding work etc including painting inner surface with one coat of black bituminous paint and outer surface of with grey/existing colour after preparation of the surface complete all as specified and directed .Note : (i) Fixing of spares parts such as Motor, grass, clamp, pump etc if found defection will be measured and paid sperately as supply only. |
| 37 | Supply only suitable size electric fan Exhaust fan motor 1400 rpm, 450 mm swip including Blade, single phase 230 volts for desert cooler/ ductable cooler complete all as specified and directed. Make- Crompton Greaves/Khaitan/Bajaj/Everst or equivalent |
| 38 | Supply only water lift pump (fully submersible) of existing size/capacity/makes for desert cooler complete all as specified and directed.Make- Murfi/Everst/Bunsal/Maxcool or equivalent. |
| 39 | Supply only wood wool pads complete all as specified and directed. |
| 40 | Servicing ofheavy duty plastic body ductableAir coolers (Which cools on the principle of water evaporation) having option of air discharge from the top or bottom 200 liters waterstorage capacity, Axial fan with 1.1 KW, 3 phase, 50Hz Ac motor and 10000 CFM air flow capable to cool 1000 Sqft area with standard height of 10 feet. All sides of cooling cabinet shall be provided with 100 mm thick paper based honeycombstructure cooling media including if necessary replacement of MS Clamp, PVC pipe, float valve, connecion pipe Capacitor, etc complete all as specified and directed. NOTE (i) Fixing of spares parts such as Motor, grass pad, capacitor, submersible pumps , canvas cloths, and internalwiring, clmapsetc if found defective will be measured and paid sperately as supply only. |
| 41 | Supply only PVC water pipe distribution and PVC pipe connection pieces for water distribution for Ductable/disert cooler incl. testing complete all as specified and directed. |
| 42 | Supply only heavy duty motor capacity Axial fan with 1.1 KW, 3 phase, 50Hz Ac for ductable Air coolersincluding testing and commissioning complete all as specified and directed. |
| 43 | Supply onlyheavy duty water lifting pump (fully submersible) of existing size/capacity/make ofAir Ductable Coolers) including testing and commissioning complete all as specified and directed. |
| 44 | Supply only canvas cotton duck canvas cloth with natural/existing color with existing size/color/make of ductable cooler including fixing arrangements such as nut bolts washers and clamp etc complete all as directed. |
| 45 | Supply only honey comb pad of 100mm size for suitable size of ductable air cooler complete all as directed. |
| 46 | Supply andfixisng of in replacement of 3 Phase starter of Cap 1 HP with single phase preventer and over load protector and 63 Amp MCB of suitable for Ductable cooler complete all as specified and directed |
| 47 | Disconnection and taking down the fan motor of Ductable cooler and refixing at the same location after rewinding by super enameled copper winding wire with existing size & guage with all insulation material including, varnishing & heating complete of the fan motor of desert cooler all as specified &directed. |
| 48 | S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 Sqmm nominal cross sectional area and one run of 6 Sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia \"medium grade\" PVC concealed conduits (ISI marked) and fittings complete all as specified and directed.NOTE:-(i) One unit length shall measured as two run of main wire and one run of conduit & earth wire.(ii) Cutting, chases and making good disturbed surface including Plastering, white washing etc. to match existing surface shall deemed to be included in quoted rates. |
| 49 | S&F in replacement sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth metal plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed. |
| 50 | Manpower To file the complaint on Customer care service Centre (LG/Hitachi/bluestar /Samsung/Lloyd /Daikin etc) of AC/Refrigerator/water Cooler for attending the unserviceable complaint for attending the complaints.If any itemsare unserviceable which is in under warranty its are replaced by Existing OEM and other items are paid by seperately.Commplaint slip will be recorded. |