Repair / Maintenance Of Ht Cable , Ht Joints And Other Connected Items At Domestic Area At Afs Phalodi-Taking Out Old Under Groundhtxlpe / Pvc Cable Of Any Size For Finding Out Fault From Trenches / Wall / Roof / Road / Pipe / Pole / Including Taking Out Ofpcc Cable Cover And Segregation / Staking Of Serviceable Cable Covers From Trenches Forreuse And Removing Broken Cable Covers From Site Complete All As Specified And As Directed By Engineer-In-Charge. ( Excavation, Earth Work Shall Be Measured And Paid For Separately Under Appropriate Item ) . 2 Re-Laying Only Old Serviceable ( Cable Obtainedfromitem Taking Out Old Cable Here-In-Before After Checking The Fault ) Under Ground Ht Xlpe / Pvc Cable 11000 Volt Grade Of Any Size In Trenches / Fixed To Wall / Pole / Roof / Laid In Floor Including Necessary Connections And Suitable Size Of Thimbling Complete All As Specified And As Directed By Engineer-In-Charge. 3 Supply And Layingxlpe Ht Cable Of Size 95 Sqmm, 3 Core, 11 Kv ‘E’ Heavy Duty With Xlpe Insulated Stranded Aluminium Conductor Served With An Inner Sheathening Of Pvc Tape Armoured With Galvanized Steel Strip Or Wire And Over All Pvc Sheathed Conforming To Is- 7098 ( Part-Ii ) With Latest Amendments Laid In Trenches / Fixed To Wall / Pole / Laid In Floor Including Necessary Connections And Suitable Size Of Thimbling Complete All As Specified And As Directed By Engineer-In-Charge. ( Excavation, Earth Work, Brick & Sand Cushioning Shall Be Measured And Paid For Separately Under Appropriate Item ) . 4 Excavation In Trenches, N.Exc 1.5M Wide & N.Exc 1.5M In Depth For Foundation & Getting Out In For Laying Of Cable Complete As Specified. 5 Removal Of Surplus Soil To A Distance Not Exceeding 50 Mtr Away And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete. 6 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 25 Cms Thick In Soils Complete All As Specified 7 Material And Labour For Dry Tibba Sand In Trenchescushioning To Under Ground Cable Spreading, Levelling Hand Punning Complete All As Specified And Directed.Note- Punned Down Thickness Will Be Measured For Payment Purpose. 8 Supply And Lay Un Reinforced Precast Concrete Cable Covers Class Hv, Type 1, Flat Of Size 300 X 180 X 40 Mm. Complete All As Specified And Directed. 9 Re-Laying Only Old Unbroken Pcc Cable Cover ( Cable Cover Obtainedfromitem Taking Out Old Cable Here-In-Before After Checking The Fault ) Of Any Sizecomplete All As Specified And As Directed By Engineer-In-Charge. 10 S&F In Replcement Of Drop Out Fuse Unit, Explusion Type For Out Door Air Break Gang Oprated Switch, Single Pole Mounted On And Including Insulators For 11 Kv Working Pressure Fixed To And Including Ms Channel With Nuts, Bolts And Washer Etc Synthetic Bounded Fuse Tube Complete With Line Capcity Suitable For Current Carrying Capacity Upto 100 Amps All As Directed Including Taking Down Old One All As Specified And As Directed. 11 Supply And Fixing In Replacement Of Insulator Pin Type Porcelain, Vitreous, White, Brown Or Green Including One Galvanized Mild Steel Spindle Two Gi Washers And One Nut Of Size 150 Mm Height 150Mm Dia Suitable For 11000 Volts Ht Grade Complete Incl Removing Of Old Unsv Items. 12 Supply And Fixing In Replacement Of Disc Type Insulator 145 Mm Height 255 Mm Dia Suitable For 11000 Volts Ht Grade Porcelain Vitreous White, Brown Or Green Including Galvanized Mild Steel Sectional Straps 38X5mm, Insulator Bolts Dia 20Mm, Washers And Nuts All As Specified Incl Removing Of Old Unsv Items. 13 S & F In Replacement Lightning Arresters Suitable For 11000 Volts, Expulsion Type Complete With All Fittings, Transmission Class, Dischange Capacity 65 Ka Complete All As Directed. 14 Supply And Stringing Acsr Conductor In Replacement Of ( Weasel / Ferret ) On Four Ploe Structure For Bus Bar Line Securing On Pole Complete Including Binding Wire, Jointing Sleeves Aluminium Tap And Pg Clamp Etc Of Any Size All As Specified And As Directed. ( Note :- ( A ) Rate Is Inclusive Of Jumper On Cutout Point / 2 Pole Structure / 4 Pole Structure Shall Be Provided With Pvc Insulated Sleeve. 15 M&L In Replacement For Cross Arms Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Aluminium Paint. 16 Supply & Lay Gi Tubinglight Grade80 Mm Dia Borein Protection Of Cable At Road Crossing / Hard Standing / Pole Protection Fixed With Clamps As Per Site Requirement Etc All As Specified Anddirected. 17 Cutting Of Road / Hardstanding Upto A Size Not Exceeding 20 Cms In Width And Not Exceeding 60 Cms In Depth For Laying Of Ht Ug Cable Protection Pipe Line Making Good The Disturbed Portion So As To Match Existing Finishing Or With Pcc 1:2:4 Type C1 Complete All As Specified. 18 Disconnecting The Electric Supply From The Existing Rmu / Vcb / Transformer / Ht Poles And Meggering The Ht Under Ground Cable For Its Ir Value And Ensuring The Servicebility By Ht Megger, Locating The Faults By Ht Fault Finder Instrument For Any Distance And Reconnect The Ht Cable. Note:- Joint Kit And Ht Ug Cable Shall Be Measured And Paid Separetly. 19 M&L For Ht Cable Route Indicator Made Out Of Ci Plat 100Mm Dia, 6Mm Thick & Fixed Over Flat Iron Of Size 60X6mm, 120 Cm In Length Embeded In Pcc 1:3:6 Type C1 Of Size 30X30x20cm Complete All As Specified And Directed By Engr-In-Charge 20 Material And Labour For Surface Excavation N Exceedind 15 Cm Deep Including Site Clearance In Soft / Loose Soil All As Sepcified And As Directed By Engr-In-Charge 21 Ht Feeder Pillar Box Factor Made Cubical Type Dust Proof, Out Door Type Both Side Opening Of Size 110 X 100 X 60 Cm Of Ms Sheet 3 Mm Thick Power Coated Machine Pressed Front Opening In Two Halves With Rubber Gasket / Bedding , Locking Arrangement With Sliding Bolt Including Aluminium Bus Bar Of Size 50 X 10 Mm And 80 Cm Long3 Strips Mounted On Ht Insulators Each Strip Should Be Munted Minimum Two Insulator And Nut Bolt Panel Shall Be Mounted On Angle Iron Frame And Legs Made From Angle Iron Of Size 50X 50 X 6 Mm And Legs 40 Cm Long Duly Spray Painted Internally And Externally With Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Grouted In Pcc 1:2:4 Type ‘B’ ( Using 20 Mm Graded Stone Aggregate Complete Incoming / Outgoing Cable Provision. 22 S &F Replacement Of Swith Air Break Gang Operated From Two Pole / Four Pole Structure And Supply & Fixing Switch Air Break Gang Operated, Triple Pole, Mechanically Operated, Mounted On Insulator And Steel Frame Withoperating Machanism Worked From Ground Level Using Heavy Duty Gi Pipe, For Current Rating 200 Amps, Outdoor Type ( Conforming To Is Specifications ) Ht 11 Kv, Triple Pole With Fixed Contacts Of Phosphorous Andbronze And A Set Of Drop Out Ht Fuse Assembly, Fuse Carrier Fitting, 12 Insulator Type Mounted On Ms Channel Operating Rod With Pad Lock Arrangement Complete All As Specified And As Directed By Engineer-In-Charge. 23 Repair To Operating Mechanism Of 11Kv Air Break Gang Operating Of Any Capacity With Necessary Oiling / Greasing To Moving Parts And To Set Right The Alignment Of Male / Female Contacts For Proper Working Complete All As Directed By Engineer-In-Charge.Note :- ( I ) .Male / Female Contacts If Replaced Shall Be Measured And Paid Separately Under Appropriate Item Of This Boq. ( Ii ) The T & P And Minor Repair I.E. Replaced The Nut / Bolts Etc. Will Be Arranged By The Contractor And The Cost Deemed To Be Included In The Quoted Rates. 24 Supply Only In Replacement Heavy Duty Male And Female ( Each Set Will Be Comprising With One Maleand One Female Contact ) Contact Of Brass Zinc Plated For Go Switches Of Current Rating Capacity 200 Amps Complete All As Directed By Engineer-In-Charge. 25 Material And Labour In Replacement Of Heat Shrinkable Straight Through Joint Suitable For Ht Xlpe Cable Of Size95 Sqmm 3 Core Armoured 11000 Volt Grade Heavy Duty Complete All As Speicified And Directed By Engineer-In-Charge 26 Material And Labour In Replacement Of Heat Shrinkable End Terminationjoint Outdoor Type Suitable For Ht Xlpe Cable Of Size95 Sqmm 3 Core Armoured 11000 Volt Grade Heavy Duty Complete All As Speicified And Directed By Engineer-In-Charge